Quotation for 20 MWp Solar Plant Works at BPCL,Uttarpradesh

BOQ of ITC Platform


S.NO. Discription UNIT QUANTITY RATE PER CUM AMOUNT

EARTH WORK IN EXCAVATION BY MECHANICAL


MEANS (HYDRAULIC EXCAVATOR / MANUAL
1 CUM 35 210 7350
MEANS) below 2500 MM IN DEPTH, INCLUDING
DISPOSAL OF EXCAVATED EARTH and Layout
marking by Total station.(soft soil strata)

EARTH WORK IN EXCAVATION BY MECHANICAL


MEANS (HYDRAULIC EXCAVATOR / MANUAL
2 CUM 30 400 12000
MEANS) below 2500 MM IN DEPTH, INCLUDING
DISPOSAL OF EXCAVATED EARTH and Layout
marking by Total station.(Hard rock strata)

Backfilling around foundation in


plinths etc. to proper grade and level
with selected materials within a lead of
100 meter from available excavated
soil including re- excavating loose
3 thickness, watering and ramming in CUM 27 130 3510
layers of 20 cm thickness to 95
% standard proctor maximum dry
density, compacted with mechanized
compaction machine, dressing etc.
complete including transportation.
(Payment shall be made for solid
measure of the consolidated filling
only)

ORDINARY CEMENT MIX PCC (M-10) WITH


GRADED STONE CHIPS (20 MM NOMINAL SIZE )
4 CUM 2.5 4800 12000
EXCLUDING SHUTTERING AND REINFORCEMENT,
IF ANY, IN GROUND FLOOR, BELOW FOOTINGS
ETC. AS PER RELEVANT CODES
CONTROLLED CEMENT CONCRETE (M25) WITH
WELL GRADED STONE CHIPS (20MM NOMINAL
SIZE) EXCLUDING SHUTTERING AND
REINFORCEMENT WITH COMPLETE DESIGN OF
CONCRETE AS PER IS:456 2009 AND RELEVANT
PUBLICATIONS, SUBMISSION OF JOB MIX
FORMULA
AFTER PRELIMINARY MIX DESIGN AFTER TESTING
5 CUM 17 6100 103700
OF CONCRETE CUBES AS PER DIRECTION OF
ENGINEER IN CHARGE. CONSUMPTION OF
CEMENT
WILL NOT BE LESS THAN 300 KG OF CEMENT
WITH SUPER PLASTICIZER PER CUBIC METER OF
CONCRETE BUT ACTUAL CONSUMPTION WILL BE
DETERMINED ON THE BASIS OF PRELIMINARY
TEST AND JOB MIX FORMULA. IN
GROUND FLOOR & FOUNDATION (USING
CONCRETE MIXTURE

REINFORCEMENT OF RCC WORK INCLUDING


INITIAL STRENGTHENING OF TMT BAR WITH
CORROSION INHIBITORS, CORROSION RESISTANT
6 STEEL(CRS) RE-BARS, FUSION BONDED EPOXY KG 885 95 84075
COATED (FBEC) RE-BARS OR ZINC COASTED RE-
BARS, REMOVAL OF LOOSE RUST, CUTTING TO
CORRECT SHAPE, PLACING IN PROPER POSITION
AS PER STRUCTURAL DETAILS
(FE-500)
SUPPLYING, FIXING AND REMOVING
FORMWORK AS PER APPROVED
DRAWINGS AT ALL ELEVATIONS
INCLUDING LABOUR, MATERIAL,
SCAFFOLDING, STRUTTING, PROPPING,
APPLYING SHUTTERING OIL, PROVIDING
POCKETS, DRIP MOULDS IF REQUIRED
7 COMPLETE ETC. AS PER SQM 170 700 119000
SPECIFICATIONS AND AS DIRECTED BY
ENGINEER FOR THE FOLLOWING. ALL
CENTERING AND SHUTTERING
MATERIALS USED SHALL BE OF STEEL
ONLY. (SHUTTERING SURFACES
COMING IN CONTACT WITH CONCRETE
ONLY SHALL BE MEASURED FOR
PAYMENT)
STANDARD NON MODULAR 230 THICK BRICK
WORK WITH 1ST CLASS BRICK HAVING
8 CUM 4 6500 24800
MINIMUM STRENGTH 10.5 N/MM2 SET IN
CEMENT, SAND,motar
18 MM THICK PLASTER WITH CEMENT, SAND
9 SQM 5 430 2150
MORTAR (1:6)
10 EXTERNAL WALL: EXTERIOR EMULSION PAINT SQM 70 318 22260
11 40 MM DOWNSIZE GRAVEL FILLING SQM 0 3000 0
14 75*75*6Edge angle for cutout kg 400 150 60000
Fdn Bolt for Inverter control room ; 16mm HDG
16 bolt with500mm lenth for detail specification see kg 19 160 3040
attached approved drawing
Shalitex Board, for detail specification see
18 NOS 2 1300 2600
attached approved drawing
100SQ *8mm thick MS insert plate welded with
19 kg 50 160 8000
100mm lugs 25*5mm for Handrail fixing.
32 NB MS Pipe for Handrail supply fixing with
22 proper welding 2 coat Primer paint and 2 Coat kg 400 170 68000
Paint .
Rail for IDT Foundation(Top 74.6mm and bottom
23 kg 75 185 13875
155.5mm and hight 161.8) fixing , welding in IDT
wall with angle and base plate
Total 546360
Note: Quantity will be change as per client approved drawing and on site situation
Project Name: 71MWp BPCL GM Project Shankargarh Prayagraj U.P.
Bill of Quantities for 132kv switch yard civil work
Project Description: Construction of 132 kV bay equipment foundation, Transformers foundation and ICR
Foundation
including excavation, concrete works, reinforcement, and chain link fencing etc.
S.NO. Discription UNIT QUANTITY RATE PER CUM AMOUNT Remark
EARTH WORK IN EXCAVATION BY MECHANICAL MEANS
(HYDRAULIC EXCAVATOR / MANUAL MEANS) below 2500
1 MM IN DEPTH, INCLUDING DISPOSAL OF EXCAVATED CUM 120 210 25200
EARTH and Layout marking by Total station.( soft soil
strata)

Backfilling around foundation in plinths etc. to


proper grade and level with selected materials
within a lead of 100 meter from available
excavated soil including re-excavating loose
2 thickness, watering and ramming in layers of CUM 80 130 10400
20 cm thickness to 95 % standard proctor
maximum dry density, compacted with
mechanized compaction machine, dressing
etc. complete including transportation.
(Payment shall be made for solid measure of
the consolidated filling only)

ORDINARY CEMENT MIX PCC (M-10) WITH GRADED


3 STONE CHIPS (20 MM NOMINAL SIZE ) EXCLUDING CUM 72 4800 345600
SHUTTERING AND REINFORCEMENT, IF ANY, IN GROUND
FLOOR, BELOW FOOTINGS ETC. AS PER RELEVANT CODES
CONTROLLED CEMENT CONCRETE (M25) WITH WELL
GRADED STONE CHIPS (20MM NOMINAL SIZE)
EXCLUDING SHUTTERING AND
REINFORCEMENT WITH COMPLETE DESIGN OF CONCRETE
AS PER IS:456 2009 AND RELEVANT PUBLICATIONS,
SUBMISSION OF JOB MIX FORMULA
AFTER PRELIMINARY MIX DESIGN AFTER TESTING OF
CONCRETE CUBES AS PER DIRECTION OF ENGINEER IN
4 CUM 100 6100 610000
CHARGE. CONSUMPTION OF CEMENT
WILL NOT BE LESS THAN 300 KG OF CEMENT WITH SUPER
PLASTICIZER PER CUBIC METER OF CONCRETE BUT
ACTUAL CONSUMPTION WILL BE
DETERMINED ON THE BASIS OF PRELIMINARY TEST AND
JOB MIX FORMULA. IN
GROUND FLOOR & FOUNDATION (USING CONCRETE
MIXTURE
REINFORCEMENT OF RCC WORK INCLUDING INITIAL
STRENGTHENING OF TMT BAR WITH CORROSION
INHIBITORS, CORROSION RESISTANT
STEEL(CRS) RE-BARS, FUSION BONDED EPOXY COATED
5 (FBEC) RE-BARS OR ZINC COASTED RE-BARS, REMOVAL OF KG 10200 95 969000
LOOSE RUST, CUTTING TO
CORRECT SHAPE, PLACING IN PROPER POSITION AS PER
STRUCTURAL DETAILS
(FE-500)
SUPPLYING, FIXING AND REMOVING
FORMWORK AS PER APPROVED DRAWINGS AT
ALL ELEVATIONS INCLUDING LABOUR,
MATERIAL, SCAFFOLDING, STRUTTING,
PROPPING, APPLYING SHUTTERING OIL,
PROVIDING POCKETS, DRIP MOULDS IF
REQUIRED COMPLETE ETC. AS PER
6 SQM 384 700 268800
SPECIFICATIONS AND AS DIRECTED BY
ENGINEER FOR THE FOLLOWING. ALL
CENTERING AND SHUTTERING MATERIALS
USED SHALL BE OF STEEL ONLY.
(SHUTTERING SURFACES COMING IN
CONTACT WITH CONCRETE ONLY SHALL BE
MEASURED FOR
PAYMENT)
STANDARD NON MODULAR 230 THICK BRICK WORK WITH
1ST CLASS BRICK HAVING
7 CUM 20 6500 130000
MINIMUM STRENGTH 10.5 N/MM2 SET IN CEMENT,
SAND,motar
18 MM THICK PLASTER WITH CEMENT, SAND MORTAR
8 SQM 50 430 21500
(1:6)
9 EXTERNAL WALL: EXTERIOR EMULSION PAINT P&A SQM 70 318 22260
Supplying and laying in the switch yard
machine crushed aggregate of 40 mm size
10 uniformly graded including spreading , laying Cum 84 3000 252000
to correct level & slope as per specifications,
drawings and as directed by the
ENGINEER.
11 P&F-Perforated MS Grating Cover 150mm dia. SQM 1 1000 1000
12 P&F- 50*50*6 angle inserted in RCC kg 200 100 20000
13 P&F -16 dia Rungs 6 Nos equally placed kg 10 110 1100
P&F-Fdn Bolt for Inverter control room ; 16mm HDG bolt
14 with600mm lenth for detail specification see attached kg 150 160 24000
approved drawing
P&F-250SQ *12mm thick MS insert plate welded with
15 kg 200 160 32000
100mm lugs 25*5mm for Handrail fixing.
P&F-200 dia CI Pipe, for detail specification see attached
16 MTR 3 4500 13500
approved drawing
Chain link fencing with toe wall ( upto 300mm OGL and
100mm UGL ) and 2 access door. MS columns of fencing
17 Meter 360 5500 1980000
(ISA50*50*6mm) with 1.7meter hight and 2.5mm thik MS
painted net mesh
Rail for IDT Foundation(Top 74.6mm and bottom
18 155.5mm and hight 161.8) fixing , welding in IDT wall with kg 75 185 13875
angle and base plate
Total 4488235

Note : The final quantities of the required materials will be determined upon the completion of detailed
engineering. Additionally, items may be added or modified in accordance with government regulations. The
quantities mentioned above are estimates and should be verified on-site.
All materials and workmanship should comply with the relevant IS codes and project specifications. Scope of
delivery of civil materials are in vendor scope.