NET24N
NET24N
NET24N
Index
1 Warnings Summary EN-1 6 Standard Programming EN-11
2 Product Description EN-3 7 Advanced Programming EN-15
3 Technical data EN-3 8 Messages shown on the Display EN-18
4 Configurations EN-4 9 Installation Test EN-19
5 Electrical Connections EN-5 10 Product Disposal EN-19
1 WARNINGS SUMMARY
WARNING! IMPORTANT SAFETY INSTRUCTIONS. CAREFULLY READ AND FOLLOW ALL WARNINGS AND INSTRUC-
TIONS THAT ACCOMPANY THE PRODUCT SINCE INCORRECT INSTALLATION COULD CAUSE HARM TO PEOPLE, ANIMALS
OR THINGS. WARNINGS AND INSTRUCTIONS PROVIDE IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION,
USE AND MAINTENANCE. KEEP THE INSTRUCTIONS TOGETHER THE TECHNICAL DOCUMENTATION AND FOR FUTURE
REFERENCE.
WARNING The device may be used by children of less than 8 years of age, people with
reduced physical, mental or sensory impairment, or generally anyone without experience
or, in any case, the required experience provided the device is used under surveillance or
that users have received proper training on safe use of the device and are aware of the
dangers related to its use.
WARNING Do not allow children to play with the device, the fixed commands or the ra-
dio controls of the system.
WARNING Product use in abnormal conditions not foreseen by the manufacturer may
generate hazardous situations; meet the conditions indicated in these instructions.
WARNING DEA System reminds all users that the selection, positioning and installa-
tion of all materials and devices which make up the complete automation system, must
comply with the European Directives 2006/42/CE (Machinery Directive), 2014/53/UE
(RED Directive). In order to ensure a suitable level of safety, besides complying with local
regulations, it is advisable to comply also with the above mentioned Directives in all extra
European countries.
WARNING Under no circumstances use the device in an explosive atmosphere or in
areas that may be corrosive or could damage product parts. Check that the temperatures
at the installation site are suitable and comply with the temperatures declared on the
product label.
WARNING When working with the “dead man” switch, make sure that there are no pe-
ople in the area where the automatism is being used.
WARNING Check that there is a switch or an omni polar magneto-thermal circuit bre-
aker that enables complete disconnection in case of over voltage category III conditions
installed upstream from the power system.
EN-1
WARNING To ensure an appropriate level of electrical safety always keep the 230V
power supply cables apart (minimum 4mm in the open or 1 mm through insulation) from
low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal
boards.
WARNING If the power cable is damaged, it must be replaced by the manufacturer or
its technical assistance service or, in any case, by a person with similar qualifications to
prevent any risk.
WARNING All installation, maintenance, cleaning or repair operations on any part of
the system must be performed exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical standards and regulations
in force in the nation of installation.
Cleaning and maintenance destined to be performed by the user must not be performed
by unsupervised children.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assem-
bly can create risk to people, animals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System and scrupulously follow all
assembly instructions.
WARNING Changing the closing intensity could lead to dangerous situations. Therefore,
qualified personnel should only perform increases to the closing force. After adjustment,
compliance with regulatory limits values should be detected with a force impact-mea-
suring instrument. The sensitivity of the obstacle detection may be adjusted gradually
to the door (see programming instructions). The anti-crushing device operation must be
checked after each manual adjustment. Manual modification of the force can only be
done by qualified personnel by performing the measurement test according to EN 12445.
Modifications to the force adjustment must be documented in the machine manual.
WARNING The compliance of the internal sensing obstacles device to requirements
of EN12453 is guaranteed only if used in conjunction with motors fitted with encoders.
WARNING Any external security devices used for compliance with the limits of impact
forces must be conform to standard EN12978.
WARNING In compliance with EU Directive 2012/19/EU on waste electrical and elec-
tronic equipment (WEEE), this electrical product should not be treated as municipal
mixed waste. Please dispose of the product and bring it to the collection for an appropri-
ate local municipal recycling.
EVERYTHING THAT IS NOT EXPRESSLY PROVIDED FOR IN THE INSTALLATION MANUAL IS NOT ALLOWED. CORRECT OP-
ERATOR OPERATION IS ONLY ENSUED WHEN THE REPORTED DATA IS RESPECTED. THE COMPANY DOES NOT RESPOND
FOR DAMAGE CAUSED BY FAILURE TO COMPLY WITH THE INSTRUCTIONS CONTAINED IN THIS MANUAL. WITHOUT AF-
FECTING THE ESSENTIAL FEATURES OF THE PRODUCT, THE COMPANY RESERVES THE RIGHT TO MAKE ANY CHANGES
DEEMED APPROPRIATE AND AT ANY TIME IN ORDER TO TECHNICALLY, STRUCTURALLY AND COMMERCIALLY IMPROVE
THE PRODUCT WITHOUT BEING REQUIRED TO UPDATE THIS DOCUMENT.
EN-2
2 PRODUCT DESCRIPTION
NET24N is a universal control panel for DEA System 1 or 2 24V operators automations with or without encoder.
The main feature of this control board is its ease of configuration of inputs and outputs according to any needs thus ensuring adaptability
to any type of automation. It is therefore easy to set up and exclude all unnecessary functions.
3 TECHNICAL DATA
TYPE 00 TYPE 01 TYPE 02 TYPE 03
ANGOLO
Livi 902/24
Livi 905/24
Livi 6/24N
Livi 9/24N
Ghost 100/200 STOP
GEKO
PASS
REV
LOOK - MAC - STING
LIVI 500/502
550PL 4÷5 m ≥6m
Power supply (V) 230 V ~ ±10% (50/60 Hz)
80 VA 250 VA 120 VA 150 VA 150 VA 250 VA*
Rated power transformer (VA)
(230/22V) (230/22V) (230/22V) (230/22V) (230/22V) (230/22V)
Fuse F1 (A) (transformer) 1A 2A 3,15A*
2x 2x 2x
Batteries
12V 1,3A 12V 1,3A 12V 4A
1x 5A 1x 10A 2x 5A 2x 5A 2x 7A*
Outputs 24V motors (maxi- Warning: The above values are calculated by taking the maximum power supplied by the respective processors.
mum output current) (A) In absolute terms, the maximum current for each output should not exceed 10A when using a single motor and
7A when using 2 motors.
Auxiliaries power supply output
24 V
Stabilized power supply output for (24V_AUX + 24V_ST = max 200mA)
safety devices
“Warning” output +24 V max 15 W
Electric lock output 24V max 5W or max 1 art. 110
Flashing light output 24 V max 15W
Operating temperature range (°C) -20÷50 °C
Receiver frequency 433,92 MHz
Transmitters type of coding HCS fix-code - HCS rolling code - Dip-switch - DART
Max remote controllers managed 100
Livi N - Rev Geko Look - Mac - Sting Livi 500 - Livi 502 - Angolo Ghost 100 - Ghost 200
EN-3
4 CONFIGURATION OF THE CONTROL PANEL
The universal control unit NET24N can be used for the management of the following types ( ) of closures motorized by DEA Sy-
stem: swing and sliding gates, overhead doors and barriers.
In order to ensure maximum adaptability to each of closure, the control board provides an initial procedure, performed only at the
first turn, for the optimal configuration of inputs, outputs and parameters (see diagram ). Once configured, the control panel will operate
in the mode “dedicated” to the of selected closing. After performing the initial configuration it is sufficient to execute the standard
programming for the installation on which it is operating.
All settings remain in memory even in the case of subsequent flare-ups (see diagram ).
If necessary the of configured closing can be later adjusted following diagram .
Following ignitions
If you have already saved a configuration, pro-
ceed as follows:
EN-4
5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H07RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING To connect the encoder to the control panel, use only a dedicated cable ≥ 3x0.25mm2.
14 (-)
“Boost” output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock
14-15
power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (ifP062=5)
15 (+)
or temporized output (if P062>5).
“Advanced Programming”.
20 - IN_5 (FCA 1) (PHOTO 2) (NONE) (NONE)
Input 5
Refer to Chapter
21 - Com N.C. N.C. N.O. N.O.
required rate.
22 - IN_4 ( PHOTO 1) (PHOTO 1) (STOP) (NONE)
Input 4
23 - Com N.C. N.C. N.C. N.O.
EN-5
Basic scheme NET24N
NET-NODE / MEMONET
NET-EXP
J5 J9
DISPLAY
DISPLAY
ENC_M1 ENC_M2
32
33
29 COM
28 IN_1
1
27 COM
2
26 IN_2
3
25 COM
4
24 IN_3
5
23 COM
6
22 IN_4
21 COM
20 IN_5
Serial N° 19 COM
000X XXXXXX
18 IN_6
7 8 9 10 11 12 13 14 15 16 17
EN-6
Wiring diagram for TYPE 00 (sliding gate)
F
230V~ 50Hz ±10%
N
230V 22V
CON 1
FLASH
2 x 0,5 mm2
PHOTO 1
2 x 0,5 mm2
J5 J9 TX RX
B A B A
COM
N.C.
N.O.
32
33
7 8 9 10 11
7 8 9 10 11 12 13 14 15 16 17
24V 15W
RED
BLUE
OPEN GATE WARNING LIGHT
2 x 1 mm2
2 x 0,5 mm2
EN-7
EN-8
TRANSFORMER
F1 230V/22V
Wiring diagram for TYPE 01 (swing gate)
POWER SUPPLY
F
230V~ 50Hz ±10% INTERNAL WIRING SET BY THE FACTORY
N
230V 22V
AURA N
EXTERNAL WIRING SET BY THE INSTALLER
CON 1 max 15W
ENCODER WIRING ONLY IF PRESENT
2 x 0,5 mm2
J5 J9 TX RX TX RX
B A B A
COM
N.C.
N.O.
COM
N.C.
N.O.
ENC ENC
M1 M2
2 x 0,5 mm2 2 x 0,5 mm2
32
33
BROWN BROWN
3 x 0,22 mm2
GREEN GREEN
WHITE WHITE
WHITE
GREEN
BROWN
N.C.
19 COM 2 x 0,5 mm2
18 IN_6
STOP (Only if needed)
7 8 9 10 11 12 13 14 15 16 17
WHITE
GREEN
BROWN
RED
RED
art.110
BLUE
BLUE
24V 15w
ELECTRIC-LOCK
2 x 1 mm2
OPEN GATE WARNING LIGHT
FLASH
A A position = operators with encoder To terminal 32/33 for normal connection
(remind to set P029=0) To terminal 1/2 for controlled safety devices (P071)
B B position = operators without encoder
(remind to set P029=1)
24V
RG58
COURTESY LIGHT
PHOTO 1
2 x 0,5 mm2
J5 J9 TX RX
B A B A
COM
N.C.
N.O.
RED
31 30
BLUE
WHITE
GREEN
BROWN
ENC ENC
M1 M2 2 x 0,5 mm2
32
33
RED
BLUE
GREEN
BROWN
WHITE
N.O.
29 COM 2 x 0,5 mm2
BROWN BROWN 28 IN_1
START
1
GREEN GREEN 27 COM 2 x 0,5 mm2
2
3 x 0,22 mm2 WHITE WHITE 26 IN_2
3 F2 N.C.
25 COM 2 x 0,5 mm2
4
24 IN_3
SAFETY (Only if needed)
5 N.C.
23 COM 2 x 0,5 mm2
6 STOP
22 IN_4
2 x 0,5 mm2
21 COM
20 IN_5
7 8 9 10 11 12 13 14 15 16 17
RED
RED
BLUE
BLUE
2 x 1 mm2
24V
COURTESY LIGHT
2 x 0,5 mm2
EN-9
EN-10
Wiring diagram for TYPE 03 (barrier)
INTERNAL WIRING SET BY THE FACTORY
TRANSFORMER
F1 230V/22V EXTERNAL WIRING SET BY THE INSTALLER
POWER SUPPLY
F
230V~ 50Hz ±10%
N
230V 22V
CON 1
2 x 0,5 mm2
PHOTO 1
2 x 0,5 mm2
J5 J9 TX RX
B A B A
COM
N.O.
N.C.
32
33
21 COM
20 IN_5
19 COM
18 IN_6
7 8 9 10 11 12 13 14 15 16 17
FLASH
RED
BLUE
24V 15W
OPEN GATE WARNING LIGHT
ELECTRO-MAGNET
2 x 1 mm2
2 x 0,5 mm2
2
2 x 0,5 mm
6 STANDARD PROGRAMMING
1 Power Supply
When turned on, “ ”, “ ” (or the current firmware version) “ ”, “ ” (or the selected Type) appear on the display in
sequence followed by the closed gate symbol “- - - - ”.
* If the control panel has already been programmed and the power fails or is switched off - once power is returned and a START command
is given, the position reset procedure is performed (see “rESP” in the table “WORKING STATUS MESSAGES” on page EN-18.
EN-11
3 Selection type of operators ! IMPORTANT !
1. Scroll down the parameters with and keys until you visua-
lise P028;
2. Access the parameter by pressing the key;
3. Acting on and keys, set:
Type 00 Type 01 Type 02 Type 03
• 005 5/24 • 000 Geko • 003 Livi 902/24 - • 003 Pass
• 006 8/24 • 001 Look - Mac 905/24 • 004 Stop
• 007 Rev - Sting
• 002 Ghost
• 003 Livi 500
- 502 - 550PL -
Angolo
Warning: If you are using non DEA System operators, set the parame-
ter on the closer value for family type and performances (refer to table
on page EN-3).
4. Confirm your choice by pressing the key (display returns again
to P028).
1. Scroll down the parameters with and keys until you visua-
lise P029;
2. Access the parameter by pressing the key;
3. Acting on and keys, set:
- d000=for operators with encoder;
- d001=for operators without encoder;
4. Confirm your choice by pressing the key (display returns again
to P029).
EN-12
7 How to adjust the limit switche
1. Scroll down the parameters untill you visualize P001;
2. confirm by pressing the key;
3. by pressing (OPEN) and (CLOSE), move the
leaf in the opening position and adjust the limit
switch cam so that it pushes the microswitch in that
point;
Repeat adjusting the closing limit switch.
4. Confirm by pressing the key (display shows again
P001).
WARNING If the Operator 2 is present, repeat the previous settings using P002.
WARNING (only Type 01 and Type 03) Once you have executed the learning stroke, operate a complete cycle (opening/closing) and then
check the manual release to make sure it is working properly. If it’s to “hard” increase the value of P057 of 1 or more.
9 Transmitters learning
9.1 Transmitters coding selection
1. Scroll down the parameters with and keys until you visualise
P027;
2. Confirm by pressing on the key;
3. Select the type of transmitter by scrolling and keys:
- d000=fix rolling-code (suggested);
- d001=complete rolling-code;
- d002=dip-switch;
- d003=DART;
4. Confirm by pressing on the key (display shows again P027).
Warning: If you need to vary the type of encoding, and only if other remo-
tes with different encoding are memorized, you need to erase memory
(P004) AFTER you have set the new encoding.
EN-13
9.2 Learning
1. Scroll down the parameters with and
keys until you visualise P005;
2. Confirm by pressing on the key;
3. When the symbol “ ” appears, press on
any key of the transmitter you want to memo-
rize;
4. The display visualizes the number of the trans-
mitter just memorized and then “ ”;
5. Memorize all necessary transmitters repeat-
ing this procedure from step 3;
6. Wait 10 seconds before quitting the memori-
zation mode, display shows now “- - - - “.
For the complete list of the “Operating Parameters” See the table
on page. EN-22.
11 Programming complete
WARNING At the end of the programming procedure, use the buttons and until the appearance of the symbol “- - - - ”, the operator
is now ready again for new manoeuvres.
To perform any “Advanced Programming” operations (cancellation of the remotes, configuration inputs, etc. ..), see on page EN-15.
EN-14
7 ADVANCED PROGRAMMING
Here are some added programming procedures relating to remotes memory management and advanced configuration of the control
inputs.
EN-15
3 Locking-Unlocking access to programming
By using a “dip-switch” remote (regardless of the type of remotes already memorized) it’s possible to lock-unlock access to the program-
ming of the control panel to avoid tampering. The remote setting is the locking-unlocking code verified by the control board.
WARNING Programming lock/unlock can also be set via Smartphone using the DEAinstaller APP. In this case, an installer code is set
(other than zero) that can only be unlocked via APP.
3.2 Unlocking access to programming
1. Scroll through the parameters with the buttons
and until the display shows P008;
2. Access the parameter by pressing the button ;
3. The display shows alternately the writing
to indicate that the control board
is waiting for the transmission of the unlocking
code;
4. Within 10 sec. press the CH1 of the “TX Master”,
the display shows before returning
to the list of parameters;
5. Access to programming is unlocked.
EN-16
4 Downloading/uploading data memory
4.1 Downloading data to an external memory unit (DOWNLOAD)
1. Scroll down the parameters with and keys until you visualize P011;
2. Press the key, the display visualizes the word “ ” flashing;
3. Press the again and continue pressing it for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the key as soon as the word “ ” stops flashing;
All the control panel configurations (TYPE, parameters, remotes, operators stroke, etc..) are saved in the external memory unit;
Warning: If there is any data in the external memory, during the memory download they will be overwritten.
5. At the end of the operation display returns to P011.
WARNING If you are not connected to any external storage units or if the connecting cable is disconnected during the data transfer
operation, the display will visualize , then the control unit is entirely reset and the display shows the word “TYPE” flashing.
Refer to the instruction of the external memory card to restore the operation of the control panel.
5 Inputs configuration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can configure each input for the
operation desired (eg START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the and to see that corresponding
to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confirm by pressing on the key to get access to the parameter (eg.
P018);
3. Scroll down with the and , keys to set the value corresponding to
the desired operation (refer to table “Input Configuration parameters” on
page EN-20);
4. Confirm by pressing on the key (display shows again P018).
5. Execute the new connection to the input just reconfigured.
6 Programming complete
WARNING At the end of the programming procedure, use the buttons and until the appearance of the symbol “- - - - ”, the operator
is now ready again for new manoeuvres.
EN-17
8 MESSAGES SHOWN ON THE DISPLAY
WORKING STATUS MESSAGES
Mess. Description
Gate is closed
Gate is opened
Opening under way
While in step-by-step mode, the control board awaits further instructions after a start command
Stop input intervened or an obstacle is detected with limited inversion duration (P055 > 0 or P056 > 0)
Board in BOOT-MODE: Indicates that the firmware is corrupted or updating. To restore the firmware, use the DEAinstaller APP and make sure
NET-NODE is corrected to the correct port.
Warning: When updating the firmware, all data in the board memory (settings and radio commands) are lost. Make sure you have backed
up the memory to be restore data after the update.
Reset current position: The control unit has just been turned on after a power failure, or the gate has exceeded the maximum number (80)
of inversions allowed without ever getting to the closing stroke, or the maximum number (15) of consecutive operations allowed of the anti-
crushing device.
Once the control unit has been reset and open command given the gate will start moving at slow speed, until it reaches end of travel.
ERROR MESSAGES
Mess. Description Possible solutions
- Make sure there are no specific frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
Error position: The reset position procedure is not suc-
- Verify that the operation is completed successfully, manually helping the run, if ne-
cessful. The control panel is awaiting commands.
cessary;
- Adjust power and speed settings if necessary.
Board programming attempted when a NET-NODE Turn off power, disconnect the NET-NODE from the communication port and turn back
device is connected. on;
External photocells and/or safety devices are activated
- Make sure that all safety devices and/or photocells installed are working properly.
or out of order.
Possible fault/overheating in the control unit’s power Turn off power for several minutes and turn back on. Give a start command: if the
circuit. message is repeated, replace the control unit.
Time-out operators run: The engine/s exceeded the - Give a start pulse to start the position reset procedure;
maximum operating time (4min) without ever stopping. - Ensure that this operation is successful.
Time-out obstacle detection: With anti-crushing sensor
- Make sure there are no specific frictions and / or obstacles during the run;
disabled, was still detected the presence of an obsta-
- Give a start pulse to initiate a position reset procedure;
cle that prevents movement of the leaf for a period of
- Verify that the operation is completed successfully.
10 seconds more.
- Make sure that operators and encoders connections are well done.
Operators mouvement not detected. - Check that jumpers J5 and J9 are well positioned as shown on the electric wiring.
- If this error appears again, replace the control panel.
- Check that the connecting cable of the external memory card is connected properly.
- If you are performing a data transfer operation (DOWNLOAD / UPLOAD), make sure
No/interrupted communication with remote memory
that it is not interrupted (eg by unplugging the card before the end of the operation).
board (also NET-EXP or NET-NODE).
Please note: the interruption of an UPLOAD, also involves a total RESET of the control
unit.
Possible fault/overheating in the control unit’s power Turn off power for several minutes and turn back on. Give a start command: if the
circuit. message is repeated, replace the control unit.
Check the wiring of the encoder and the motor. Shut the power supply off and on again.
Give a start command: if the message is repeated, perform the following checks.
Possible malfunction in the control unit’s power circuit - Enter P003 and move the door using the + and - buttons.
or in the encoder circuit. - If the door moves at maximum speed and the display shows Err7, replace the motor’s
encoder card.
- If the motor still remains stationary, replace the control unit.
Sensitive regulation parameters were edited via
DEAinstaller APP without running motor stroke learning Run motor stroke learning (P003) first to be able to run any other operation.
at the end of the operation.
NET-NODE connected to the incorrect communication Connect NET-NODE to the correct port according to that indicated in the control unit
port. diagram.
EN-18
9 INSTALLATION TEST
The testing operation is essential in order to verify the correct installation of the system. DEA System wants to summarize the proper
testing of all the automation in 4 easy steps:
● Make sure that you comply strictly as described in paragraph 2 “WARNINGS SUMMARY”;
● Test the opening and closing making sure that the movement of the leaf match as expected. We suggest in this regard to perform va-
rious tests to assess the smoothness of the gate and defects in assembly or adjustment;
● Ensure that all safety devices connected work properly;
● Perform the measurement of impact forces in accordance with the standard 12445 to find the setting that ensures compliance with
the limits set by the standard EN12453.
10 PRODUCT DISPOSAL
WARNING In compliance with EU Directive 2012/19/EU on waste electrical and electronic equipment (WEEE), this electrical prod-
uct should not be treated as municipal mixed waste. Please dispose of the product and bring it to the collection for an appropriate
local municipal recycling.
EN-19
PAR. PROCEDURE
Positioning of operator 1
Positioning of operator 2
Memorization of the motors’ stroke
Deletion of transmitters
PROGRAMMING PROCEDURES
Transmitters memorizing
Search and deletion of a transmitter
Restoring the operating parameters
Lock access to programming
How to learn connected DE@NET devices (unused at the moment)
Restoring the “I/O” configurations (input/output)
Downloading data on the external memory unit
Uploading data from an external memory unit
Visualisation of inputs and operations-counter status
Unused parameter
Unused parameter
EN-20
SETTABLE VALUES
DEFAULT VALUES
(for different standards of installation)
SETTABLE VALUES
TYPE TYPE TYPE TYPE
00 01 02 03
• 000: IN3 type=free contact
• 001: IN3 type=constant resistance 8K2
EN-21
Allocation of CHANNEL 1 of remotes
INPUTS CONFIGURATION
Operator n.1 force adjustment while closing (if = 100% obstacle detection deactivated)
TYPE 00 - 01 - 03 ONLY: Operator n.2 force adjustment while opening (if = 100% obstacle detection
deactivated)
TYPE 02 ONLY: Secondary force adjustment in closing: adjusts the motor’s force during the last part of the
closing movement defined by P058
Operator n.2 force adjustment while closing (if = 100% obstacle detection deactivated)
Automatic closing times adjustment (if = 0 automatic closing deactivated)
Pedestrian automatic closing time adjustment (se = 0 pedestrian automatic closing deactivated)
Pedestrian stroke duration adjustment
Pre-flashing time adjustment
Adjustment of phase displacement time while opening
Adjustment of phase displacement time while closing
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of
automatic opening and closing
EN-22
TYPE TYPE TYPE TYPE
00 01 02 03
• 000: NONE (unused parameter)
CH1
• 001: START (start)
• 002: PEDESTRIAN (pedestrian)
• 003: OPEN (separated open) CH2
• 004: CLOSED (separated close)
• 005: Unused
• 006: Unused CH3
• 007: ELOCK-IN (electric-lock activation. See P062)
• 008: AUX_IN (with NET_EXP only)
CH4
• 009: STOP
• 000: HCS fix-code • 002: Dip-switch
• 001: HCS rolling-code • 003: DART
• 000: GEKO • 005: LIVI 5/24
• 001: LOOK - MAC - STING • 006: LIVI 8/24
• 002: GHOST 100/200 • 007: REV
• 003: 500 - 502 - 902 - PASS - 550PL -
ANGOLO
• 004: 502MT/24 - 902R/24 - STOP
15%tot…...........................100%tot
0%tot...................................100%tot
15%tot…...........................100%tot
0sec...................................255sec
0sec...................................255sec
5%tot…...........................100%tot
0sec…….10sec
0sec……………30sec
0sec……………30sec
• 000: disabled
• 001: activated only upon opening
• 002: activated on automatic opening and closing
EN-23
Ram blow function: if=0 “Ram blow” function deactivated; if=1 it pushes the motors closed for one second
before each opening movement, so as to ease the releasing of any electric lock; if>1 it execute a periodic
pushing stroke so as to maintain the wings under pressure on the closing strokes. If closing limit switches
are installed, it performs this function only if they are not activated, i.g. when there’s a pressure decrease
on the stroke.
“Reversal” mode selection (during the manoeuvre a command impulse reverse the mouvement) or “step by
step” (during the manoeuvre a command impulse stops the mouvement). A next impulse restart the operator
to the opposite direction.
PHOTO input functioning: If=0: photocell enabled while closing and starting when the gate is
PHOTO 1 stopped; if=1 photocells are always enabled; if=2 photocells are enabled while closing only.
When enabled, its activation provokes: the inversion (while closing), the stop (while opening)
and prevent the starting (when gate is closed).
If = 3-4-5, the operation is identical to values 0-1-2 but with the” close immediately “function
PHOTO 2 enabled: in any case, when opening and / or pausing time, removing a any obstacle the gate
will end the opening maneuver before closing it automatically after a 2 second fixed delay.
Operation mode selection of the warning light output:
If = 0 “warning light” (output always ON when the gate is open, OFF after a closing operation),
If = 1 “flashing warning light” (slow intermittent output during opening and fast while closing, always ON at
gate opened, always OFF at the end of a closing operation only),
If> 1 “courtesy light” (output ON during each movement, OFF when the motor stops, after the setting delay)
OPERATING PARAMETERS
Searches for end of stroke while opening too: when activated, operators stop only at their arrival et the end
of stroke, also while opening.
Warning: During the emergency operation (rESP), the motor executes the first maneuver while opening. In
addition, if any limit switches, the parameter is forced to 1.
“soft start” function: motors accelerate gradually until they reach the set speed, avoiding sudden departures
ONLY TYPE 02: If=3 the opening slow space (P035) also becomes the space within which the port moves at
slow speed (P031) and close start.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the opening.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the closing.
Facilitation manual release: If≠0, after ending the closing or opening maneuver, the engine reverses for
a brief time to release the pressure on it, and thus facilitate the manual release. The set value shows the
length of the inversion. If=0 function disabled
TYPE 00 - 01 - 03 ONLY: Adjustment of the opening stroke margin: it adjusts the duration of the last part of
the stroke during which an obstacle is interpreted as a stroke, blocking the motor without performing the
inversion.
For motors with encoders, the set value indicates the number of revolutions of the rotor; while for motors
without encoder, the value is expressed in% of the maximum stroke.
Warning: for motors without encoder, if P035 (duration slow-down while opening) is >10%, it forces the
stroke detection margin so that it’s the same than the slow-down.
TYPE 02 ONLY: Duration adjustment for the secondary force in closing: adjusts the duration of the last part
of the closing movement, in which the force is managed separately with P039. The value is expressed in
number of revolutions of the rotor.
EN-24
TYPE TYPE TYPE TYPE
00 01 02 03
0...................................255
EN-25
TYPE 00 - 01 - 03 ONLY: Adjustment of the closing stroke margin: it adjusts the duration of the last part of
the stroke during which an obstacle is interpreted as a stroke, blocking the motor without performing the
inversion.
For motors with encoders, the set value indicates the number of revolutions of the rotor; while for motors
without encoder, the value is expressed in% of the maximum stroke.
TYPE 02 ONLY: Adjustment of the stop-margin in closing: adjusts the duration of the last part of the closing
movement, in which an obstacle is seen as a stop, causing the motor to stop without reversal on the obstacle.
The value is expressed in number of revolutions of the rotor.
TYPE 00 - 01 - 03 ONLY: Operators force adjustment at stroke arrival - If=0, setting off (the force value on the
stroke is calculated automatically) - If≠0 (operators with encoder) it indicates the force value (expressed in%
of the max value) set in the last length.
TYPE 02 ONLY: Force adjustment in the stop margin in closing, its duration is set through P059.
“Energy saving” mode: If=1 after 10sec of inactivity, the control panel turns the 24V outputs and the display
off that will be turned on at first command received (use recommended battery-powered and / or solar
panel).
Warning: when “Energy saving” is enabled, SAS function is not available.
Warning: when “Energy saving” is enabled, only the stabilized output 24V_ST must be used to power
accessories.
Electric-lock output operating: If=0 “boost” output for electric-lock art.110 power supply, If=1 24V output
controlled by the ELOCK_IN input as pulsed mode,If=2 24V output controlled by the ELOCK_IN input as
OPERATING PARAMETERS
step-by-step mode, If=3 electro-brake output for not self-locking operators, If=4 24V output for electric-lock
power supply via an external relay, If=5 24V output for electro-magnets power supply for barriers, If>5 24V
output controlled by the ELOCK_IN input as temporized mode (the set value indicates the switch-off delay in
seconds).
Warning: To adjust the activation/deactivation times in the 000 | 004 | 005 modes, use parameter P064.
Run direction inversion: If=1 automatically reverses the outputs open/close of the operators, avoiding having
to manual change the wiring when installing the operator in an inverted position.
Warning: Changing this parameter you need to change the parameters for the opening and closing limit
switches.
Electric lock duration adjustment
If P062=000|004, adjust the activation time of the LOCK output;
If P062=005, adjust the deactivation time of the LOCK output;
Maintenance Operations-counter: if = 0 reset the counter and disables the intervention request , if>
0 indicates the number of operations (x 500) to be made before the control panel executes a 4 second
additional pre-flash to indicate the need of maintenance.
i.g.: If P065 = 050, operations number = 50x500 = 25000 operations
Warning: Before you set a new value of the counter-manoeuvres maintenance, the same must be reset by
setting P065= 0 and only later P065 = “new value”.
Selection of operating flashing light output: If=0 intermittent flashing light output;
If=1 Fixed flashing light output (for flashing lights with intermittent interior circuits).
Operation of the SFT input: if = 0 safety edge always enabled, if = 1 safety edge enabled only
SAFETY 1 while closing, if = 2 safety edge enabled only while closing and before any movement, if = 3
safety edge enabled only when opening, if = 4 safety edge enabled only while opening and
before any movement; as for the obstacle detection with internal anti-crushing sensor, also the
activation of the inputs SFT1 and SFT2 causes the complete or partial reversal as set by P055
SAFETY 2 (duration of inversion on obstacles while opening, and P056 (duration of reversal on obstacle
while closing)
EN-26
TYPE TYPE TYPE TYPE
00 01 02 03
1...................................255
0%tot…...........................100%tot
0%tot…...........................100%tot
0sec……………..10sec
EN-27
Delay on limit switch detection: the operation is stopped after 1,5 sec from limit switch detection. When
during this delay a stop is detected, the operator is suddenly stopped
Safeties self-test: if = 0 24V output with autotest disabled; if = 1 24V output for safeties with self-test
(it turn the output off and check the contact opening before each maneuver).
Attention: In order to work in self-test mode, all devices must be connected to the stabilized output 24V_ST
(1-2), and be wired and aligned before the motor stroke learning (P003).
Activation of SAS function (with NET_EXP only): SAS output is connected to an input STOP / SAS INPUT of a
second control panel, causing the operation “trap man” (disabling the opening of the second door as long as
the first is not completely closed).
If this parameter is enabled after a reset, it performs an automatic RESP during which the SAS output is not
OPERATING PARAMETERS
activated. If limit switches are present and they are crushed after a reset, the RESP is not executed.
Warning: if both doors are manually unlocked and moved from the closed position creates the interlock
condition. You will then need to manually close at least one of the two doors.
Forced “Hold to Run”: if this function is enabled, all inputs configured as OPEN and CLOSE change
automatically also to OPEN UP and CLOSE UP (hold-to-run commands) if activated and kept active in case a
safety contact (photocell and/or safety edge) is triggered. This function thus allows to control the automation
even in case the safety devices are faulty. If the input is no longer maintained active, the automation returns
to automatic operation.
When using safety edges configured as SAFETY 1 or SAFETY 2, this function is not compatible with the values
001 and 003 of parameters P067 and P068.
For security reasons, we recommend that you DO NOT use this function in case there are any clocks/timers
connected to the inputs configured as OPEN or CLOSE.
Unused parameter
Unused parameter
Unused parameter
Unused parameter
Configuration parameters dedicated to the expansion card NET_EXP (for a detailed description of the
parameters, refer to the instruction manual).
EN-28
TYPE TYPE TYPE TYPE
00 01 02 03
• 000: “limit switch delay disabled
• 001: “limit switch delay enabled
• 000: “acceleration deactivated (it runs an acceleration of
minimum durability, almost imperceptible)
• 00X: “adjusts the acceleration durability at 1,5 sec (X*6 ms)
EN-29
EN-30
Eseguire il fissaggio alla parete usando opportuni tasselli
per viti Ø5 (non fornite); Fix the box on the wall with appro-
priate bushings to anchor screws Ø5 (not included); Le fixer
au mur en utilisant des douilles à expansion pour vis adéqua-
tes Ø5 (pas incluses); Die Wandbefestigung vornehmen,
verwenden Sie geeignete Dübel für Ø5 Schrauben (nicht im
Lieferumfang); Efectuar la fijación a la pared utilizando ade-
cuados tacos para tornillos de Ø5 (no incluidos); Executar a
fixação a parede usando apropriadas rolhas para parafusos
Ø5 (não fornecidas); Zamocować do ściany,
przy pomocy odpowiednich kołków do śrub Ø5
(nie na wyposażeniu); Выполнить крепление к
стене с помощью соответствующих дюбелей
для болтов Ø 5 (не входят в комплект).
VISTA DA “A”
VIEW FROM “A”
VUE DE “A”
ANSICHT “A”
VISTA DESDE “A”
VISTA DE “A”
WIDOK Z “A”
ВИД ИЗ “A”
59 59
VISTA DA “A” Fori da eseguire sul fondo della scatola con seghe a tazza Ø37 per
l’inserimento dei fermatubi; VIEW FROM “A” Holes to be drilled on the bottom of
the box with a hole saw Ø37 to introduce tube fastening; VUE DE “A” Trous à percer
au fond du boîtier avec une scie-cloche Ø37 afin d’introduire des bloque tube; AN-
SICHT “A” Mit einem 37mm Kronenbohrer die Rohrdurchführungen vohrnemen;
VISTA DESDE “A” Agujeros que deben hacerse en la base de la caja con sierras
cilíndricas de Ø37 para la introducción de los paratubo; VISTA DE “A” Furos pra
executar no fundo da caixa com serra a xícara Ø37 para inserimento dos fixação
do tubo; WIDOK Z “A” Otwory do wykonania na dnie skrzynki z wiertłami Ø37 dla
włożenia zacisku; ВИД ИЗ “A” Отверстия для выполнения в нижнем основании
ящика с помощью кольцевой пилы Ø37 для установки фиксаторов.
I-2
NET24N/C
32
33
29
28
1
27
2
26 ENC M2
3
25
4
24
5
23
6
22
21
20
19
18
MOT 1 MOT 2
ENC M1
MOT 1 (GND)
MOT 2 (GND)
7 8 9 10 11 12 13 14 15 16 17
L N
I-3
EUDeclarationofConformity(DoC)
Companyname: DEASYSTEMS.p.A.
Postaladdress: ViaDellaTecnica,6
PostcodeandCity: 36013PioveneRocchette(VI)ͲITALY
Telephonenumber: +390445550789
EͲMailaddress: [email protected]
declarethattheDoCisissuedunderoursoleresponsibilityandbelongstothefollowingproduct:
Apparatusmodel/Product: NET24NͲNET24N/C
Type: Universalcontrolpanelfor24Voperators
Batch: Seethelabelonthebackoftheusermanual
TheobjectofthedeclarationdescribedaboveisinconformitywiththerelevantUnionharmonisationlegislation:
Directive2014/53/UE(REDDirective)
Directive2011/65/EU(RoHS)
Thefollowingharmonisedstandardsandtechnicalspecificationshavebeenapplied:
Title: Dateofstandard/specification
EN61000Ͳ6Ͳ2 2005+EC:2005
EN61000Ͳ6Ͳ3 2007+A1:2011+EC:2012
ETSIEN301489Ͳ1 2019v2.2.3
ETSIEN301489Ͳ3 2019v2.1.1
EN60335Ͳ1 2012+EC:2014+A11:2014+A13:2017
ETSIEN300220Ͳ1 2018v3.2.1
ETSIEN300220Ͳ2 2018v3.2.1
EN50581 2012
Additionalinformation
Signedforandonbehalfof:
PioveneRocchette(VI) TizianoLievore
00
01/14/2019 (Administrator)
BATCH