Data sheet 3RV1011-1BA10

Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.4...2 A
N-release 26 A Screw terminal Standard switching capacity

product brand name SIRIUS


product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss [W] for rated value of the current
● at AC in hot operating state 7.25 W
● at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at AC rated 690 V
value
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation in
networks with grounded star point
● between main and auxiliary circuit 400 V
● between main and auxiliary circuit 400 V
mechanical service life (switching cycles)
● of the main contacts typical 100 000
● of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
type of protection according to ATEX directive Ex II (2) GD
2014/34/EU
certificate of suitability according to ATEX directive DMT 02 ATEX F 001
2014/34/EU
reference code acc. to IEC 81346-2 Q
Substance Prohibitance (Date) 01.01.2013 00:00:00
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -20 ... +60 °C
● during storage -50 ... +80 °C
● during transport -50 ... +80 °C
temperature compensation -20 ... +60 °C
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable current response value current of the 1.4 ... 2 A
current-dependent overload release

3RV10111BA10 Subject to change without notice


9.20.2021
Page 1/6 © Copyright Siemens
operating voltage
● rated value 690 V
● at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operational current rated value 2A
operational current at AC-3 at 400 V rated value 2A
operating power at AC-3
● at 230 V rated value 0.37 kW
● at 400 V rated value 0.75 kW
● at 500 V rated value 0.75 kW
● at 690 V rated value 1.1 kW
operating frequency at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
● ground fault detection No
● phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
breaking capacity operating short-circuit current (Ics)
at AC
● at 240 V rated value 100 kA
● at 400 V rated value 100 kA
● at 500 V rated value 100 kA
● at 690 V rated value 2 kA
breaking capacity maximum short-circuit current (Icu)
● at AC at 240 V rated value 100 kA
● at AC at 400 V rated value 100 kA
● at AC at 500 V rated value 10 kA
● at AC at 690 V rated value 2 kA
response value current of instantaneous short-circuit trip 26 A
unit
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value 2A
● at 600 V rated value 2A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 230 V rated value 0.125 hp
● for 3-phase AC motor
— at 460/480 V rated value 0.75 hp
— at 575/600 V rated value 1 hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
● at 240 V none required
● at 400 V gL/gG 35 A
● at 500 V gL/gG 25 A
● at 690 V gL/gG 25 A
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 90 mm
width 45 mm
depth 75 mm
required spacing

3RV10111BA10 Subject to change without notice


9.20.2021
Page 2/6 © Copyright Siemens
● for grounded parts at 400 V
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for live parts at 400 V
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for grounded parts at 500 V
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for live parts at 500 V
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for grounded parts at 690 V
— downwards 20 mm
— upwards 20 mm
— backwards 0 mm
— at the side 9 mm
— forwards 0 mm
● for live parts at 690 V
— downwards 20 mm
— upwards 20 mm
— backwards 0 mm
— at the side 9 mm
— forwards 0 mm
Connections/ Terminals
product component removable terminal for auxiliary and No
control circuit
type of electrical connection
● for main current circuit screw-type terminals
arrangement of electrical connectors for main current Top and bottom
circuit
type of connectable conductor cross-sections
● for main contacts
— solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (1 ... 4 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²)
tightening torque
● for main contacts with screw-type terminals 0.8 ... 1.2 N·m
● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m
size of the screwdriver tip Pozidriv 2
design of the thread of the connection screw
● for main contacts M3
Safety related data
B10 value
● with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
● with low demand rate acc. to SN 31920 50 %
● with high demand rate acc. to SN 31920 50 %
failure rate [FIT]
● with low demand rate acc. to SN 31920 50 FIT
protection class IP on the front acc. to IEC 60529 IP20
touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front
display version for switching status Rocker switch
Certificates/ approvals

3RV10111BA10 Subject to change without notice


9.20.2021
Page 3/6 © Copyright Siemens
General Product Approval For use in hazardous locations

Declaration of Conformity Test Certificates Marine / Shipping

UK Declaration of Type Test Certific- Special Test Certific-


Conformity ates/Test Report ate

Marine / Shipping other

Miscellaneous Confirmation

other Railway

Special Test Certific-


ate

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1011-1BA10
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1011-1BA10
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RV1011-1BA10
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1011-1BA10&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RV1011-1BA10/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV1011-1BA10&objecttype=14&gridview=view1

3RV10111BA10 Subject to change without notice


9.20.2021
Page 4/6 © Copyright Siemens
3RV10111BA10 Subject to change without notice
9.20.2021
Page 5/6 © Copyright Siemens
last modified: 2/5/2021

3RV10111BA10 Subject to change without notice


9.20.2021
Page 6/6 © Copyright Siemens

You might also like