PAMAS-OLS50P-Medicion Particula OnLine
PAMAS-OLS50P-Medicion Particula OnLine
Monitoring Facility Systems in Aviation Industry Particle measurement in eight size channels
REV 04/2019
I n t h e w o r l d o f pa r t I c l e s pa m a s c o u n t s
PAMAS OLS50P
Long-term contamination analysis
and fluid condition monitoring
The PAMAS OLS50P online PAMAS POV software
Technical Data
particle counter controls the The measuring operation can be
cleanliness of operating liquids started and stopped with the Particle counter:
(e.g. hydraulic or lubricating oil) PAMAS POV software (PAMAS Particle measurement in
and of water (e.g. rinsing water Online Visualization). The measur- eight size channels
in parts cleaning systems). ing results are displayed on charts Pressure range:
and schedules and can 0 - 6 bar
The compact online particle coun- be printed and exported.
Data transmission:
ter PAMAS OLS50P has been PAMAS OLS50P in stainless steel shell RS 485 interface
developed to be installed in to analogue 4-20 mA interface.
almost every system and offers Particle sensor Parallel data transmission
a variety of interfaces for both The instrument is equipped with for four size channels or
analogue and digital data transfer. the light extinction sensor serial data transmission for
All types of light extinction sen- PAMAS HCB-LD-50/50 with a all eight size channels.
sors of the PAMAS HCB-LD series nominal flow rate of 10 or 25 ml/ Volumetric sensor:
can be integrated in the PAMAS min per minute and a maximum PAMAS HCB-LD-50/50
OLS50P. If required, the sensor particle concentration of 24.000 Calibration range:
can be built of resistant mate- particles per ml at a coincidence Cumulative and differential counts 4-70 µm(c) according
rial so that it can be used for the rate of 7.8%. Particle sensors reported in numerical tables or in to ISO 11171
analysis of all types of liquids and with a higher flow rate and a illustrative graphs 1-200 µm according
critical fluids, from water down to higher maximum concentration The software simultaneously to ISO 21501
strong acid. are available on request. controls several sample points. Maximum
particle concentration:
Calibration PAMAS PCT software 24,000 p/ml at a coincidence
The integrated wear resistant
rate of 7.8%.
ceramic piston pump guarantees The Automatic Particle Counter The PAMAS PCT software (PAMAS
a constant flow rate of 10 or is calibrated according to Interna- Component Test) enables online PAMAS SLS-25/25
25 ml/min at a pressure range tional Calibration Standards. cleanliness tests of manufactured Calibration range:
from 0 to 6 bar. components in machinery engi- 1,5-25 µm(c) according
Software neering applications (test rigs). to ISO 11171
With its eight different size chan- The PAMAS OLS50P online 0,5-20 µm according
nels, the particle counter PAMAS particle counter can be operated The particulate contamination is to ISO 21501
OLS50P counts particles in eight with two optional software pro- reported numerically or shown on Maximum particle
grammes: a graph via single measurement concentration:
size classes.
13,000 P/ml at a coincidence
Registered trademarks are properties of their individual owners. All specifications are subject to change without notice.
PAMAS POV software results or via arithmetic means
rate of 7.8%
(PAMAS Online Visualization) of successive measurements. The
PAMAS OLS50P for PAMAS PCT software PAMAS PCT software automati- Size:
Phosphate-Ester: (PAMAS Component Test) cally stores measuring data and 330 x 230 x 120 mm
For Phosphate-Ester based parameter.
hydraulic liquids (e.g. aviation With the help of the software, Case protection:
hydraulic fluids), the PAMAS the measuring results are report- IP 64
OLS50P is manufactured with a ed according to common cleanli-
special stainless steel shell that ness standards (e.g. ISO 4406 or
protects the housing from cor- SAE AS 4059). The measuring
rosive liquids. parameters may be programmed
individually according to operator
needs.
PAMAS HEAD OFFICE Dieselstraße 10, D-71277 Rutesheim, Phone: +49 7152 99 63 0, Fax: +49 7152 99 63-32, Email: [email protected]
PAMAS USA 1408 South Denver Avenue, Tulsa, OK 74119 USA, Phone: +1 918 743 6762, Fax: +1 918 743 6917, Email: [email protected]
PAMAS BENELUX Mechelen Campus, Schaliënhoevedreef 20T, B-2800 Mechelen, Phone: +32 15 28 20 10, Mobile: +32 477 42 48 62, Email: [email protected]
PAMAS FRANCE Route du Tailleur 210/136, F-40170 Saint-Julien-en-Born, Mobile +33 6 25 33 20 41, Email: [email protected]
PAMAS LATIN AMERICA Curitiba-Paraná, Brazil, Phone/Fax: +55 41 3022 5445, Mobile: +55 41 999 72 21 73, Email: [email protected]
PAMAS INDIA No. 203, I floor, Oxford House, #15 Rustam Bagh Main Road, Bangalore 560017, India, Phone: +91 80 41 15 00 39, Email: [email protected]
PAMAS HISPANIA Calle Zubilleta No. 13 1°B, ES-48991 Algorta, Mobile: +34 67 75 39 699, Email: [email protected]
PAMAS UK Sci-Tech Daresbury, Keckwick Lane, Daresbury, Cheshire WA4 4FS, Mobile: +44 79 17 71 33 66, Email: [email protected]