ANEXO A - GRAFICAS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Amps X 10 TDF (Nom. kV=0,4, Plot Ref.

kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

500 500

300 300

TDF_Q5
TDF_Q5.3 Merlin Gerin
Merlin Gerin NS160-D
NS160-D Size = 160 Amps
100 100
Size = 160 Amps Thermal Trip = 100% (160 Amps)
Thermal Trip = 80% (128 Amps) Magnetic Trip = Fixed
Magnetic Trip = Fixed
50 50

30 30
TDF_Q5.1
Schneider Electric
TM50D
Size = 50 Amps
10 Thermal Trip = 100% (50 Amps) 10

Magnetic Trip = Fixed

5 5

Seconds
Seconds

3 3

TDF_Q5

1 1

,5 ,5
TDF

,3 ,3

TDF_Q5 - 3P
12,989kA @ 0,4kV
,1 (Sym) ,1
TDF_Q5.1 TDF_Q5.3
TDF_Q5.1 - 3P
12,989kA @ 0,4kV
,05 (Sym)
,05

,03 TDF_Q5.3 - 3P ,03


12,989kA @ 0,4kV
(Sym)

,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 10 TDF (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 28-11-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase
Amps X 100 Bus15 (Nom. kV=0,4, Plot Ref. kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

500 TG_Q0 500


Schneider Electric
300 TM250D 300
Size = 250 Amps
Thermal Trip = 100% (250 Amps)
Magnetic Trip = 10X (2500 Amps)

100 100

50 TG_Q0 50
AL_TTM - P
30 3 - 1/C 120 mm² 30
Copper XLPE
Tc = 90C
Plotted - 1 x 120 mm²
AL_TTA RED
10 10
CU 3-1/C 120 AL_TTA RED - P
10 m 3 - 1/C 120 mm²
Copper XLPE
5 5
Tc = 90C
Seconds

Seconds
Plotted - 1 x 120 mm²
3 3

TTA ATI
TTM_Q1
1 TAG: 1
Mitsubishi NF400-HEW
Sensor = 400 Plug = 400 Amps
,5
TTA ATI_Q0 Iu = 0,98 (392 Amps) ,5
TL = 100 Tl = TL
Isd = 6 (2400 Amps)
,3 ,3
Tsd = 0,06 (I^x)t = OUT
Ii WS1 = 16 (6400 Amps)

AL_TTM
CU 3-1/C 120
,1 ,1
7m TTM_Q1 - 3P
16,938kA @ 0,4kV
(Sym)
,05 ,05

,03 TTM_Q1 ,03

TG_Q0 - 3P
20,558kA @ 0,4kV
(Sym)
,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 100 Bus15 (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 28-11-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase
Amps X 10 TG AUX (Nom. kV=0,4, Plot Ref. kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

TG AUX_Q0.3
500 500
Merlin Gerin
NS250-D
300 Size = 250 Amps 300
Thermal Trip = 100% (250 Amps)
Magnetic Trip = 5X (1250 Amps)

TG AUX_Q0
100 Schneider Electric Micrologic 5.2 A/E (NSX) 100
Sensor = 250
Ir = 250 A (250 Amps)
50 tr = 16.0 50
Isd = 7 (1750 Amps)
30 tsd = 0 OFF (I^x)t = OUT 30
Ii = 12 (3000 Amps)

10 TG AUX_Q0 10

5 5
Seconds

Seconds
3 3
TG AUX

1 1

,5 ,5
TG AUX_Q0.3
,3 ,3

TG AUX_Q0 - 3P
12,989kA @ 0,4kV
(Sym)
,1 ,1
TG AUX_Q0.3 - 3P
12,989kA @ 0,4kV
(Sym)
,05 ,05

,03 ,03

,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 10 TG AUX (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 28-11-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase
Amps X 10 TDC (Nom. kV=0,4, Plot Ref. kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K
TDC_Q7
500
Merlin Gerin 500
NS160-D
Size = 160 Amps
300 300
Thermal Trip = 100% (160 Amps)
Magnetic Trip = Fixed

TDC_Q7
TDC_Q7.6
100 100
Schneider Electric
TM50D
Size = 50 Amps
50 50
Thermal Trip = 100% (50 Amps)
Magnetic Trip = Fixed
30 30
TDC TDC.1
TDC_Q7.6.1
Merlin Gerin
C60N/H/L - C curve (IEC)
10 Size = 32 Amps 10
Thermal Trip = Fixed
Magnetic Trip = Fixed
5 5
Seconds

Seconds

TDC_Q7.1 TDC_Q7.6 TDC_Q7.6.1


3 3

TDC_Q7.1
1 Merlin Gerin 1
C60N/H/L - C curve (IEC)
Size = 25 Amps
,5 Thermal Trip = Fixed ,5
Magnetic Trip = Fixed
,3 ,3

TDC_Q7 - 3P
12,989kA @ 0,4kV
(Sym)

,1 ,1
TDC_Q7.1 - 3P
12,989kA @ 0,4kV
(Sym)

,05 ,05
TDC_Q7.6 - 3P
12,989kA @ 0,4kV
,03 (Sym)
,03

TDC_Q7.6.1 - 3P
12,989kA @ 0,4kV
(Sym)

,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 10 TDC (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 28-11-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase
Amps X 10 TGAyF EMER (Nom. kV=0,4, Plot Ref. kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

500 500

300 300

TG AUX_Q0.3
100 Merlin Gerin 100
NS250-D
Size = 250 Amps
50
Thermal Trip = 100% (250 Amps) 50
Magnetic Trip = 5X (1250 Amps)

30 30
TG AUX_Q0.3
TGAyF EMER_Q3
Legrand
DPX3 160 TM
Size = 100 Amps
10 10
Thermal Trip = 80% (80 Amps)
Magnetic Trip = Fixed TGAyF EMER
5 5
TGAyF EMER_Q1
Seconds

Seconds

Merlin Gerin
3 3
NS160-D
Size = 160 Amps
TGAyF EMER_Q1 TGAyF EMER_Q2 TGAyF EMER_Q3 TGAyF EMER_Q4
Thermal Trip = 90% (144 Amps)
Magnetic Trip = Fixed
1 1

TGAyF EMER_Q2
Merlin Gerin
,5 ,5
NS100-D TG AUX_Q0.3 - 3P
Size = 63 Amps 12,989kA @ 0,4kV
(Sym)
,3 Thermal Trip = 100% (63 Amps) ,3
Magnetic Trip = Fixed TGAyF EMER_Q1 - 3P
12,989kA @ 0,4kV
(Sym)
TGAyF EMER_Q4
TGAyF EMER_Q2 - 3P
Schneider Electric
,1 12,989kA @ 0,4kV ,1
TM32D (Sym)
Size = 32 Amps
Thermal Trip = 70% (22,4 Amps) TGAyF EMER_Q3 - 3P
,05 12,989kA @ 0,4kV ,05
Magnetic Trip = Fixed (Sym)

,03 TGAyF EMER_Q4 - 3P ,03


12,989kA @ 0,4kV
(Sym)

,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 10 TGAyF EMER (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 28-11-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase
Amps X 10 TTM (Nom. kV=0,4, Plot Ref. kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

500 500
TTM_Q1
300 TAG: 300
Mitsubishi NF400-HEW
Sensor = 400 Plug = 400 Amps
Iu = 0,98 (392 Amps)
TL = 100 Tl = TL
Isd = 6 (2400 Amps)
100 100
Tsd = 0,06 (I^x)t = OUT
Ii WS1 = 16 (6400 Amps)

50 50

30 30

10 10

5 5

Seconds
Seconds

3 3

TTM_Q1
1 1
TTM_Q4
TAG:
,5 Mitsubishi NF400-HEW ,5
Sensor = 400 Plug = 250 Amps
Iu = 1 (250 Amps)
,3 ,3
TTM TL = 100 Tl = TL
Isd = 6 (1500 Amps)
Tsd = 0,06 (I^x)t = OUT
Ii WS1 = 10 (2500 Amps)

,1 ,1

TTM_Q4

,05 ,05

,03 ,03

TTM_Q4 - 3P TTM_Q1 - 3P
16,938kA @ 0,4kV 16,938kA @ 0,4kV
(Sym) (Sym)

,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 10 TTM (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 11-12-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase
Amps X 100 TG AUX (Nom. kV=0,4, Plot Ref. kV=0,4)
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

500 TTM_Q4 500


TTM_Q4
Mitsubishi NF400-HEW
300 300
Sensor = 400 Plug = 250 Amps
Iu = 1 (250 Amps)
TL = 100 Tl = TL
Isd = 6 (1500 Amps) AL TGAUX_TTM
Tsd = 0,06 (I^x)t = OUT CU 3-1/C 120
100 100
Ii WS1 = 10 (2500 Amps) 25 m

50 50

TG AUX_Q0
30 30

TG AUX
10 10

5 5
Seconds

Seconds
3 3

TG AUX_Q0
Schneider Electric Micrologic 5.2 A/E (NSX)
Sensor = 250
1 Ir = 250 A (250 Amps) 1
tr = 16.0
Isd = 7 (1750 Amps)
,5
tsd = 0 OFF (I^x)t = OUT ,5
Ii = 12 (3000 Amps)

,3 ,3

AL TGAUX_TTM - P
3 - 1/C 120 mm²
Copper XLPE
,1 Tc = 90C ,1
Plotted - 1 x 120 mm²

,05 ,05

,03 ,03
TG AUX_Q0 - 3P
TTM_Q4 - 3P

,01 ,01
,5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K

Amps X 100 TG AUX (Nom. kV=0,4, Plot Ref. kV=0,4) ETAP Star 21.0.1C

Project: Date: 28-11-2024


Location: SN: 0809449000
Contract: Rev: Base
Engineer: Fault: Phase