EN - HYC - XX - MAN - OCPP Error Codes Software Version 2.2.x
EN - HYC - XX - MAN - OCPP Error Codes Software Version 2.2.x
DATE
9/9/2024
errorCode ocppName
0 No Error
1 PLC Error
2 SLAC Error
3 SLAC interrupted
4 Link Error
5 Link Error
6 SDP Error
7 SDP Error
8 TCP Error
9 TCP Error
10 TCP Error
11 TCP Error
12 TCP Error
13 TCP Error
14 V2G Error
15 Lock Fault
16 Lock Fault
17 Lock Fault
18 Isolation Fault
19 Stack Error
20 Cable Error
23 Authorization Timeout
24 Isolation Fault
25 Isolation Fault
26 Isolation Fault
27 Isolation Fault
28 Isolation Fault
29 Isolation Fault
30 Cooler Error
31 Cooler Error
32 Cooler Error
33 Cooler Error
34 Cooler Error
36 Cooler Error
39 Surge Arrester Error
40 ISO Selftest Cable Plugged
41 Meter Pairing Error
42 Meter Eichlog full
43 Meter communication Error
44 Meter fatal Error
45 Meter full charging Error
46 Meter no pairing Error
47 Meter latest start charge refused
Error
50 EV Error voltage present
51 EV Error other
52 EV Wrong voltage requested
53 EV Wrong CP state
54 EV Wrong precharge voltage
55 EV No current flow
60 Cable communication Error
61 Cable leakage Error
62 Cable temphigh Error
63 Cable tempDelta Error
64 Cable tempSensorDc Error
65 Cable tempSensorHousing Error
66 Cable HW fault Error
67 Cable critical lever Error
70 CHAdeMo timeout 1 Error
71 CHAdeMo timeout 3 Error
170 Serial_Port_Open
171 Serial_Port_Configure
172 Serial_Port_Rs485
173 Serial_Port_Poll_Error
174 Serial_Port_Unexpected_Poll_Even
t
175 Serial_Port_Timeout
176 Serial_Port_Write_Error
177 Serial_Port_Read_Error
180 DzgMeteringBus_Timeout
190 DzgProtocol_Fewer_Bytes_Than_M
inimum
191 DzgProtocol_Fewer_Bytes_Than_F
rame_Element_Length
192 DzgProtocol_Trailing_Bytes_Detect
ed
193 DzgProtocol_Checksum_Mismatch
194 DzgProtocol_Request_Response_
Mismatch
195 DzgProtocol_Payload_Error
196 Authorization_Failed
197 Sequence_Error
198 EmergencyStopCP_Unplug
199 EmergencyStopCP_CPError
200 EmergencyStopCP_BeforeCharging
Loop
201 EmergencyStopCP_DuringCharging
Loop
202 EmergencyStopCP_AfterChargingL
oop
203 EmergencyStopCP_Other
204 EmergencyStopPP_ContinuityLoss
207 EmergencyStopCP_WrongTeardow
nOrderOnUserStop
208 EmergencyStopCP_PrematureUnpl
ugAfterChargingLoop
220 SLAC_Timeout_ParamReq_AfterPl
ugin
221 SLAC_Timeout_ParamReq_AfterEv
Restart
222 SLAC_Timeout_ParamReq_AfterEv
seRestart
223 SLAC_Timeout_ParamReq_Other
224 SLAC_Timeout_StartAttnCharInd
225 SLAC_Timeout_AttnCharRsp
226 SLAC_Timeout_ValidateReq
227 SLAC_Timeout_MatchReq
228 SLAC_Error_Other
1000 Door Closed
1001 Door Opened
1002 Emergency StopButton Disengaged
hyperlogName
NoError
PLC_Error
DEPRECATED__SLAC_Timeout
SLAC_Interrupted
Link_Timeout
Link_Interrupted
SDP_Timeout
SDP_Interrupted
TCP_AcceptError
TCP_EmptyPacket
TCP_Error
TCP_POLLERR
TCP_POLLHUP
TCP_POLLRDHUP
V2G_Error
Lock_Fault
Lock_OpenLoad
Lock_Overcurrent
ISO_Fault
Stack_Error
Cable_Error_unknown
Authorization_Timeout
ISO_Fault_Check
ISO_Fault_Charging
Discharge_Slow
Output_Voltage_Low
ISO_Warning_Check
ISO_Warning_Charging
Cooler_Error_Level
Cooler_Error_Communication
Cooler_Error_Fan1
Cooler_Error_Fan2
Cooler_Error_Temp_Sensor
Cooler_Error_Level_Sensor
Surge_Arrester_Error
ISO_Selftest_Cable_Plugged
Meter_Error_Pairing
Meter_Error_Eichlog_Full
Meter_Error_Communication
Meter_Error_Fatal
Meter_Error_Charging_Full
Meter_Error_No_Pairing_Executed
Meter_Error_Latest_Start_Charge_Refused
EV_Error_VoltagePresent
EV_Error_Other
EV_Error_WrongVoltageReq
EV_Error_WrongCPState
EV_Error_WrongVoltagePrecharge
EV_Error_NoCurrentFlow
Cable_Error_Communication
Cable_Error_Leakage
Cable_Error_TempHigh
Cable_Error_TempDelta
Cable_Error_TempSensorDc
Cable_Error_TempSensorHousing
Cable_Error_HW_Fault
Cable_Error_CriticalLevel
CHAdeMO_Error_Timeout1
CHAdeMO_Error_Timeout3
CHAdeMO_Error_Timeout5
CHAdeMO_Error_Timeout6
CHAdeMO_Error_Timeout9
CHAdeMO_Error_Timeout11
CHAdeMO_Error_Timeout14
CHAdeMO_Error_Timeout15
CHAdeMO_Error_Timeout_CAN
CHAdeMO_Error_VehicleNormalStop
CHAdeMO_Error_VehicleFaultFlags_Voltage
CHAdeMO_Error_VehicleFaultFlags_Current
CHAdeMO_Error_VehicleFaultFlags_Temperature
CHAdeMO_Error_VehicleFaultFlags_ChargingSystem
CHAdeMO_Error_VehicleFaultFlags_ShiftPosition
GBT_Error_WrongProtocolVersion
GBT_Error_BRM_Timeout
GBT_Error_BCP_Timeout
GBT_Error_BRO_00_Timeout
GBT_Error_BRO_AA_Timeout
GBT_Error_BCS_Timeout
GBT_Error_BCL_Timeout
GBT_Error_BSM_Timeout
Stack_Error_Duplicate
Stack_Allocation_Timeout
Output_Disabled_IsoFault
Output_Disabled_IsoFaultPersistent
Output_Disabled_IsoWarningCount
Output_Relay_Plus_Welded
Output_Relay_Minus_Welded
Partitioning_Relay_Welded
Serial_Port_Open
Serial_Port_Configure
Serial_Port_Rs485
Serial_Port_Poll_Error
Serial_Port_Unexpected_Poll_Event
Serial_Port_Timeout
Serial_Port_Write_Error
Serial_Port_Read_Error
DzgMeteringBus_Timeout
DzgProtocol_Fewer_Bytes_Than_Minimum
DzgProtocol_Fewer_Bytes_Than_Frame_Element_Length
DzgProtocol_Trailing_Bytes_Detected
DzgProtocol_Checksum_Mismatch
DzgProtocol_Request_Response_Mismatch
DzgProtocol_Payload_Error
Authorization_Failed
Sequence_Error
EmergencyStopCP_Unplug
EmergencyStopCP_CPError
EmergencyStopCP_BeforeChargingLoop
EmergencyStopCP_DuringChargingLoop
EmergencyStopCP_AfterChargingLoop
EmergencyStopCP_Other
EmergencyStopPP_ContinuityLoss
EmergencyStopCP_WrongTeardownOrderOnUserStop
EmergencyStopCP_PrematureUnplugAfterChargingLoop
SLAC_Timeout_ParamReq_AfterPlugin
SLAC_Timeout_ParamReq_AfterEvRestart
SLAC_Timeout_ParamReq_AfterEvseRestart
SLAC_Timeout_ParamReq_Other
SLAC_Timeout_StartAttnCharInd
SLAC_Timeout_AttnCharRsp
SLAC_Timeout_ValidateReq
SLAC_Timeout_MatchReq
SLAC_Error_Other
Door Closed
Door Opened
Emergency StopButton Disengaged
Alpitronic GmbH | Srl. Bozner-Boden-Mitterweg 33 | Via di Mezzo ai Piani 33. I-39100 Bozen | Bolzano
descriptionDetailed
No error.
Communication failure with powerline modem of CCS connector, Powerline modem does
not respond or communication gets interrupted
Timeout while waiting for SLAC match
Connection interrupted while waiting for SLAC match,Cable disconnect has been
detected. Loose connection / Charge cable may not be plugged in correctly
Timeout while waiting for GPhy LINK after SLAC match
Connection interrupted while waiting for GPhy LINK after SLAC match, Loose connection
/ Charge cable may not be plugged in correctly
Timeout waiting for SECCDiscover request from EV
Cable disconnect detected while waiting for SECCDiscover request, Loose connection /
Charge cable may not be plugged in correctly
TCP socket to EV failed
TCP socket to EV failed
TCP socket to EV failed
POLLERR flag active while reading TCP socket. Usually indicating a Reset-flag (RST -
0x04) sent by the EV. Reset, indicates a harsh shutdown. Usually to be used in case of
errors
POLLHUP flag active. Connection terminated by local low-level socket handling. Usually
due to an internal socket handling error
POLLRDHUP flag active. Usually indicating a Finish-flag (FIN - 0x01) sent by the EV.
Finish indicates a intended termination of the socket, connection in a good case
scenario. However, FIN is often used instead of RST, even in error scenarios
V2G Sequence error, The received V2G message is not allowed during the current state
A lock fault was reported by the EV (CCS: Field: EVError, CHAdeMO: control signal on
cable, monitored and mapped on a CAN signal by CTRL_IO). Charge cable may not be
plugged in correctly / Failure of the locking actuator
Locking circuit detected no current flow. Locking actuator not connected properly to
CTRL_IO board (KF3) / Failure of the locking actuator
Locking circuit detected a high current flow, exceeding the permitted limits. Charge cable
may not be plugged in correctly / Failure of the locking actuator
The RCD device reported an error, Residual current device (RCD) tripped
Power general stack error was diagnosed. Log files have to be analyzed for further
details, At least one Powerstack is in Fault-state. Check individual errors - if available
Cable cooling unit error, Cable not properly connected to CTRL_IO board (KF3) / Cable
damaged
The customer did not authenticate in time
An isolation fault was detected during isolation check
An isolation fault was detected during an ongoing power transfer
Overall timeout of 20s for CH_SUB_03 (insulation/latch check) and the subsequent
output voltage descent was exceeded
Output voltage too low to perform isolation check
An isolation warning was detected during isolation check, Isolation resistance dropped
below warning threshold
An isolation warning was detected during an ongoing power transfer, Isolation resistance
dropped below warning threshold
Cable cooling unit: coolant level low
Communication with cable cooling unit failed
Cable cooling unit: Fan 1 defect
Cable cooling unit: Fan 2 defect
Cable cooling unit: temperature sensor failed
Cable cooling unit: coolant level sensor failed
Surge arrester device indicated a fault state
A connector was re-plugged into the EV during an ongoing isolation self test
Pairing with meter failed
Meter log is full
Communication with meter failed. In case of TYPE 2: RCD Tripped
Meter reported fatal error
Meter charge log full
Meter is not paired with SECC
Error while trying to start a metering session
Voltage > 60 V Measuresd at charging connector before charging session has been
initialized
The EV has communicated an error
The EV requested an abnormal (out of bounds) target voltage
The EV requested power delivery, but it´s CP state is not C or D
The EV requested an abnormal (out of bounds) target voltage
No current flow to EV
CAN timeout for cable-related message
Leakage of cooling liquid detected
Any of the measured temperature is too high
Temperature delta between DC+ and DC- too high
Summarized temperature status
Housing temperature status
Cable Good signal reported (non-critical) error, not covered by the errors above
Cable Good signal reported critical error
Timeout of 120s expired while waiting for vehicle CAN communication being initiated by
the EV
Timeout of 8s expired while waiting for activation of both redundant enable charging
signals by the EV
EV contactors weren't closed within 4s after activating switch d2 (charge sequence
signal 2)
Precharge and closing of charging station output contactors wasn't completed within 4s
after closing of EV contactors
EV failed to reset the Vehicle charge permission(opto coupler j) within 4s after the
transmission of an active chargingstop control-flag
EV contactor welding detection not completed within 10s
After completion of the welding detection and deactivation of j1 and j2, an unenergized
state wasn't detected within 4s(CHAdeMO version < v1.1 → 6s)
The EV didn't stop transmitting its CAN messages within 2.5s (3s for CHAdeMO version
< v1.1>)
Either of the CAN messages expected from the vehicle wasn't received in time (timeout:
400ms), while monitoring routine (CH_SUB_06) was active
Vehicle set the Normal stop request beforecharging-flag (CAN message 102)
over voltage-flag / under voltage-flag was set by EV (CAN message 0x102), indicating,
that measured battery voltage exceeded / fell below the upper / lower voltage limit
(defined by EV). Furthermore, this error can indicate an unacceptable deviation between
measured battery voltage (EV measurement) and reported output present current
(charging station measurement).
High battery temperature-flag was set by EV (CAN message 0x102). This flag is set,
when the battery temperature exceeded a predefined temperature limit.
The EV detected either a vehicle error or a charging station error
DZG protocol error - Error constructing frame from bytes: fewer bytes in frame than
claimed by frame element length
DZG protocol error - Error constructing frame from bytes: trailing bytes detected
DZG protocol error - Error constructing frame from bytes: checksum mismatch
DZG protocol error - Received structurally mismatching frame in read attempt loop
Emergency stop triggered due to premature unplugging during the charging loop
EV didn't initiate SLAC (by sending CM_SLAC_PARM.REQ) after cable was plugged in
solveActions
Reconnect vehicle
Soft reset
Hard reset vehicle
Reconnect
Move EV vehicle
Reconnect
Move EV
Hard reset vehicle
Reconnect
Move EV vehicle
Reconnect
Move EV
Hard reset vehicle
Reconnect
Move EV vehicle
Reconnect
Move EV
Hard reset vehicle
Reconnect
Move EV vehicle
Reconnect
Move EV vehicle
Reconnect
Move EV vehicle
Reconnect
Move EV
Hard reset
Fault analysis through alpitronic
Reconnect vehicle
Move EV
Hard reset vehicle
Reconnect
Move EV
Hard reset
Fault analysis through alpitronic
Reconnect vehicle
Move EV
Hard reset vehicle / Resend connector unlock command via Backend
Reconnect
Soft reset
Hard reset
Fault analysis through alpitronic
Reconnect vehicle / Resend connector unlock command via Backend
Soft reset
Hard reset vehicle / Resend connector unlock command via Backend
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Reconnect vehicle
Hard reset
Try
Harddifferent
reset vehicle
Fault analysis through alpitronic
Technician on site
Reconnect vehicle
Reconnect vehicle
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Hard
No reset action required
further
Reconnect vehicle
Soft reset on site
Technician
Reconnect vehicle
Soft reset on site
Technician
Technician on site
Technician on site
Reconnect vehicle
Soft reset
Hard reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset
Hard reset
Fault analysis
Technician on through
site alpitronic
Reconnect vehicle
Reconnect vehicle
Fault analysis
Reconnect through alpitronic
vehicle
Fault analysis through alpitronic
Reconnect vehicle
Fault analysis through alpitronic
Reconnect vehicle
Soft reset
Hard reset
Reconnect vehicle
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset
Fault analysis through alpitronic
Technician on site
Reconnect vehicle
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset
Hard reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft reset vehicle
Reconnect
Soft
Faultreset
analysis through alpitronic
Technician on site
Error
Equipment Down
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Critical Warning
Critical Warning
Error
Info
Error
Error
Error
Error
Critical Warning
Critical Warning
Critical Warning
Critical Warning
Critical Warning
Critical Warning
Critical Warning
Critical Warning
Error
Error
Error
Equipment Down
Error
Equipment Down
Equipment Down
Equipment Down
Error
Error
Error
Error
Error
Error
Error
Error
Equipment Down
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Equipment Down
Equipment Down
Equipment Down
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error