OPERATION MANUAL

INDUSTRIAL ROLLER SHUTTER MOTORS

‘MOSEL’ Series Industrial Motors utilizes most advanced production techniques combined with the latest
technologies available to provide reliability with diverse functionality. They are simple to install and are
proven to be ideal accessories to a wide variety of applications.

‘MOSEL’ Series Industrial Motors can be installed to both Left and Right sides of openings and can be
equipped for direct-wiring and remote-control operations when power is disconnected or temporarily
unavailable therefore making them ideal for installations in areas subject to frequent power cuts.

I. Work Environment and Conditions


1、Working temperature: -40℃ to 60℃
2、Relative working humidity: 90% at 25℃
3、Short-term working:
a、 Continual Single-Phase operation should not exceed 7 minutes
b、 Continual Three-phase operation should not exceed 10 minutes
II. Main Specifications and Technical Parameters for Standard and ‘F’Type
Set load Set load Max
Max external Weight of
Power
Model Lifting force Output torque Output turn lifting diameter Chain No. host motor
(w)
(kg.f) N.m Speed r/min height (m) of (kg)
Door (m)
220V 50Hz
SEL-300-1p 250 300 168 4.8 6 0.42 08B 11.8
SEL-500-1p 370 500 343 4.8 6 0.48 10A 12.8
SEL-600-1p 370 600 412 4.8 6 0.48 10A 12.8
SEL-800-1p 460 800 647 4.6 7 0.54 10A 12.8
SEL-1000-1p 460 1000 809 4.1 6 0.54 10A 13.8
380V 50/60Hz
SEL-300-3p 180 300 168 4.8 6 0.42 08B 11.8
SEL-500-3p 250 500 343 4.8 6 0.48 10A 12.8
SEL-600-3p 250 600 412 4.8 6 0.54 10A 12.8
SEL-800-3p 460 800 647 4.6 7 0.54 10A 12.8
SEL-1000-3p 460 1000 809 4.1 6 0.54 10A 13.8
SEL-1300-3p 600 1300 1401 5.6 9 0.54 12A 22
SEL-1500-3p 600 1500 1671 5.6 12 0.54 12A 22
SEL-2000-3p 750 2000 2450 3.6 12 0.65 16A 29

Note: ‘F’ =Fire Safety Models

Product Characteristics
● Simple pleasing design of structure
1
● Good drive/size ratio
● Selected elements ensure safe working and reliability
● Low noise
● Small oscillation
● Lightweight
● Safety Device in of chain-break

III. Installation & Testing


1、 The ‘MOSEL’ Series Motors are produced for standard mounting to the right of the opening (viewed form inside). If
you wish to install to the left side, it is necessary to loosen the bolts on the brake-shell. This will allow you to turn the shell
180º and then re-tighten the bolts
Note: The white and green lines of the switches should change positions.

2、The support board of the chain-wheel can be installed horizontally, according to the specific situation-as shown in Fig.3-
or it can be fixed within a range of 0-45 degrees. When the support board is not installed horizontally the brake-shell must
be turned so that the loop-type hand-pull chain can lie vertically in a normal manner.
Note: Special attention must be given to the joint of the shell-body and the top cover of the motor. When you are certain that
there is no gap then tighten the bolts (diagonally). If a gap exists, and is allowed, the braking efficiency could be affected.

● The roller shutter door motors should be installed exactly horizontally.


● The roller axle of the shutter should door should be homocentric and horizontal
● The roller shutter should be free of any obstructions.
● The vertical hanging length of the chain must be adjusted within 3-6mm-adjustment should be made before hanging
the shutter onto the roller axis.
● It is strictly forbidden to pull on the motor down lead.
● External power cord should be minimum 1mm diameter.
● Special attention should be given to protecting the motor from humidity and rain, to prevent short-circuiting.

The phase order must not be violated for three-phase motors. When the rise-up becomes downside the motors must be
immediately stopped for readjustment of the phase order .If an interim power source is used for testing, attention should be
given to connect in correct sequence when normal power source is introduced.

The correct operation approach is that when the rise-up button on the White line is pressed, the motor should turn anti-
clockwise, allowing the position limiting device to function-see Fig .1 for derails. Otherwise the shutter door would be out
of control and will be damaged.

The motor must be satisfactorily earthed to prevent potential injury from shocks .The earthing connection bolts should be
fixed to the chain wheel support board OR electric appliance control box.
Position Limiting Diagram

Fig.1 When the motor is to be fixed on the left when the motor is to be fixed on the right

2
Serial
1 2 3 4 5 6
Number

Position Joggling Locking Gearing Position limiting Position limiting


Name
limiting gear switch bolt wire screw nut slide piece

Drum Installation Diagram


Fig.2

Note: Right side install, Dl Shutter Door Motor Model


Code NO. D1 D2 D3 L C Axle
<500 30 4″ 35 4 206
500 35 4″/5″ 35 4 207
600 35 5″ 35 4 207
Values 800 36 6″ 35 4 207
1000 40 6″ 35 5 208
1300/1500 40 8″ 35 6~10 308
2000 60 10″ 40 8~10 1212

Support Plate Install Diagram


3
A Model Common Model
Fig.3

Note:300kg—500kg central distance m=270mm


600kg central distance m=270mm Code No. H F K M Ф
800kg—1000kg 500 200 93 320 156
800kg central distance m=320mm 1300kg 520 200 80 347 186
1500kg 550 250 90 364 186
B Model 300kg central distance m=272mm 2000kg 650 250 96 454 186
500kg central distance m=272mm

MOSEL Series 220V Electric Wiring Diagram

4
Symbol Name Size & Model Quantity

KH Heat Protector JOK—SF—1 1

1SB、2SB、3SB Switch 2 open, 1 close 1

Top and bottom


SL1、SL2、SL3 JWL—1—11 2—4
Buttons

1K—4K Small relay JQX—13F 4

C Capacitor 16-30μf 450VAC 1

U Rectifier 1

YC Magnet coil 1

Single—phase
M ~220V 1
Motor

(300kg——1000kg)

MOSEL Series 380V Electric Wiring Diagram

Symbol Name Size & Model Quantity

KH Heat Protector JOK—SF—1 1

1SB、2SB、3SB Switch 2 open, 1 close 1

Top and bottom


SL1、SL2 JWL—1—11 2—4
Buttons

1K—4K Small relay JQX—13F 4

U Rectifier 1

YC Magnet coil 1

Single—phase
M ~380V 1
Motor

(300kg——1000kg)

MOSEL Series 380V Electric Wiring Diagram

Symbol Name Size & Model Quantity

KH Heat Protector JOK—SF—1 1

1SB、2SB、3SB Switch 2 open, 1 close 1

Top and bottom


SL1、SL2 JWL—1—11 2—4
Buttons

1KM、2KM Small relay CJXZ—6.3/0.1 2

U Rectifier 1

YC Magnet coil 1

Single—phase
M ~380V 1
Motor

(1300kg——2000kg)

Ⅳ.Usage
5
Press“UP”or “down” buttons .If there is no reaction—press the “stop” button to avoid potential damage to the motor.
Check to see if there is any blockage under the shutter door before closing it. Passage under the shutter is forbidden during
the process of starting or closing the door.
When closing the shutter, with the power off, lightly pull on the shutter door loop for slide—down at even controlled speed.
Relax the pull on the on the pulling loop when the door is almost closed and then pull again to close it completely.
Motors for fire shutter doors are equipped with separate control boxes—specially qualified personnel should undertake
regular and preventative maintenance and inspection.

☆The above is right-side installation-see Connection diagram; change the position of white and green lines in left-side
installation
Remote Controller and Shutter door Motor (Switch) Connection

☆See Connection diagram for right-side installation; change the position of white and green lines for left-side installation
☆Uncover the pipe at the middle of the button line, -Cut off yellow line to uncover lead line, and connect them separately
6
V. Trouble shooting
Problem Analysis Solution
No stop at upper and bottom Incorrect connection of phases, and the
Cut off power, check, adjust and change
positions position fails

Circuit contact fails,over low voltage ‹185v, Polish contact or change relay, adjust
Up only, or down only
Electromagnetic iron weak in attraction force voltage button contact, change magnet
6
coil
Button contact fails, position limiting switch Adjust and change joggling switch and
No reaction
contract fails, circuit cut off relay
Relay contact fused, joggling switch out of Repair or change joggling switch and
Non-stop Operation
control relay
Non-operation, only noise Machine blocked, voltage too low Remove block, adjust voltage

VI. Type Selection Formula


Output torque T
Total weight of shutter door G------------------------------- = Motor type –total lifted weight Kg
Radius of rolling axle R×9.8
G=door material/m2×length ×width (see attachment for details)
Material Kg ×m2
Aluminum alloy 5-6
Mesh door 12
Powder coated steel 8-14
Stainless steel 10-18
Fire prevention door 25-36

Single-phase shutter door motor has obvious fluctuations of voltage, and therefore attention should be paid to voltage in
type in type selection.

VII. Shutter Door Axle


When the door is more than 5m in width, with more than 3 mm thickness and self-weight is above 350kg, 5 seamless pipe
with more than 3mm thickness and zinc plated must be used to prevent pipe axle from bending which would lead to
overload and a short life of motor, and even directly damage teeth of motor’s gear.

VII. Motor Accessories:


1.Chain wheel support , 2.big chain wheel (including axle connect ); 3.roller chain ; 4.drum core axles; 5.axle
and axle support ; 6.gearing board ;7.support board ×2;
8.button/switch; 9.3 meters of button/switch line; 10.stainless steel switch box (equipped with night lock).

IX. Warranty Period

One year from the day of shipment; parts are offered at preferential prices.

X. Options

1.Wireless remote controller


2.UPS electricity storage device AT (220)
3.Fire prevention electric control system (A.C models); LTFV –temperature sensing metal blow controller;
4.Stainless steel switch.

You might also like