Data Domain and DDVE: How to Upgrade the Data Domain Operating System
Summary: The Data Domain Operating System (DDOS) can be upgraded by following these instructions.
Article Content
Instructions
This article was created to assist Dell EMC customers with upgrading their Data Domain.
This is only for DDOS and DDVE upgrades. This is not valid for a DDHA upgrade.
For DDHA upgrades visit DataDomain: OS Upgrade Guide for High Availability (HA) systems
For DDVE deployed in the Cloud (Azure, GCP and AWS), the DDOS .rpm file required to upgrade the code is the same that is used for
the hardware models. It can be downloaded from Support for DD OS.
If this Data Domain is part of an IDPA, it should be upgraded within the IDPA upgrade and it can NOT be upgraded separately.
You must check the compatibility between your Data Domain required version and other integrations in your environment. Check the
compatibility guide using the E-Lab Interoperability Navigator.
Check the simple code matrix in the notes section in this document to determine how many steps are needed. There should be at least
24 hours between each upgrade step, unless upgrading from 6.2.x to 7.0.x, then no cooling period is required.
You can find the upgrade path from the release notes of the version that you are upgrading. Reference PowerProtect and Data Domain
core documents for a list of Data Domain documents.
To check whether MDU is needed, reference Data Domain: DDOS 7.x Minimum Disruptive Upgrade (MDU) and DDOS 7.2 Compatibility.
🛈 Note:
LTS releases:
General Availability releases have completed Data Domain Internal QA Testing and are available for installation in production environments.
Long-Term-Support releases have unique characteristics different from the latest feature releases.
Are targeted for customers who adopt a standard version across their data centers and remain at that version for a year or more.
Are made available every year at the same time.
Are proactively maintained and updated through Maintenance Releases on a regular cadence.
Are declared as LTS at the time of release with no vetting period.
Have an offering of 36 months of software issue remediation and root cause analysis.
Replace the Target Code concept.
https://www.dell.com/support/kbdoc/en-us/article/lkbprint?ArticleNumber=000021710&AccessLevel=40&Lang=en 1/4
26/6/24, 2:44 p.m. Data Domain and DDVE: How to Upgrade the Data Domain Operating System | Dell US
5. Confirm that the Data Domain is not DDHA. Do NOT proceed if this is a DDHA as it has a different upgrade procedure.
a. ha status
6. Check the current code version installed (check the matrix to confirm if this is a single step or multistep upgrade).
a. system show version
7. Check for alerts and determine if the alert can be cleared or needs an action to be taken. Check the DD Error Message Catalog. If you
are unsure or if there are hardware issues, do NOT proceed. Engage the DellEMC support team.
a. alerts show current
8. Check the file system status and confirm that it states filesystem is enabled and running.
a. filesys status
9. Check the space and confirm that the post-comp partition has at least 10% free space.
a. df
🛈 Note: If you have Archive Tier/Extended Retention, you cannot upgrade to DD 7.x version as archive tier is no longer supported in DD 7.x version and
causes the upgrade to fail.
10. Check if the cleaning process is running. If yes, stop it before proceeding.
a. filesys clean status
b. filesys clean stop
11. Check if cloud tier is enabled. If yes, stop any data movement before proceeding.
a. data-movement status
b. data-movement stop all
c. cloud clean status
d. cloud clean stop
12. Check the replication configuration. Check the CTX column. If you ever see it showing 0, it means its Collection Replication (Mirroring),
this is rare, but when you have this type of replication it means both servers must be upgraded simultaneously.
a. replication show config
13. Check if any replication jobs are running or initializing. If initialization is in progress, it must be stopped before proceeding with the
upgrade. Sometimes it can take a long time to stop replication initialization. If replication is not running, we can proceed with the
upgrade normally.
a. replication show stats
b. To stop replication, reference Data Domain: Replication initialization is in progress and upgrade cannot proceed.
14. Check for disk reconstruction or failed disks. Ensure that there are no Failed (F), Reconstructing (R), Copy (C) or Absent Disks (A).
https://www.dell.com/support/kbdoc/en-us/article/lkbprint?ArticleNumber=000021710&AccessLevel=40&Lang=en 2/4
26/6/24, 2:44 p.m. Data Domain and DDVE: How to Upgrade the Data Domain Operating System | Dell US
Process 4: Upgrade
1. When the host is back online, relogin to the Putty session.
2. Run the pre-check steps 7, 8 and 9 to confirm that the system is state is healthy after the reboot.
3. List the content of /ddr/var/releases/
4. Start the upgrade pre-check. Do NOT run the upgrade if issues are detected.
a. system upgrade precheck <filename.rpm>
5. Start the upgrade.
a. system upgrade start <filename.rpm>
6. The server reboots automatically. You can monitor the system by pinging the IP address by using Command Prompt.
🛈 Note: If you see "Maximum days between change" is set to a small value (for example, 90), change it to a higher value (for example, 99999):
b. user password aging set <ddboost username> max-days-between-change 99999
🛈 Note: If the Dell/EMC Remote Proactive team is assisting you with your DDOS upgrade, reference Data Domain: FAQs for Remote Proactive Data
Domain Upgrades.
Additional Information
https://www.dell.com/support/kbdoc/en-us/article/lkbprint?ArticleNumber=000021710&AccessLevel=40&Lang=en 3/4
26/6/24, 2:44 p.m. Data Domain and DDVE: How to Upgrade the Data Domain Operating System | Dell US
Partner Notes
Videos
Article Properties
Affected Product
Data Domain, DD OS
Version
14
Article Type
How To
https://www.dell.com/support/kbdoc/en-us/article/lkbprint?ArticleNumber=000021710&AccessLevel=40&Lang=en 4/4