An-Najah National University ‫جامعة النجاح الوطنية‬

Faculty of Engineering and


‫كلية الهندسةوتكنولوجيا‬
Information Technology
‫المعلومات‬

Building Engineering Department


Structural Design of Buildings II(10611416)
Design Project

Instructor Name
:Student Names
Academic Year:2020/2021
...................................………………… - 1
Semester: Second
……………………………………………-2
Credit Hours: 1
……………………………………………-3
---------------------------- :Date
……………………………………………-4
……………………………………………-5

..……………………………… :Section
Total Mark: 100
Weight: 25

Question Grade Required Time


Question Points ILO’s % ILO’s
(minutes)
Q1 100 i, ii, iii, iv

Student Grade

Good Luck

1
Project Data:

 Nine story building.


 Floorheight=3.3m
 Steel,fy=420MPa
 The superimposed dead load on the concrete slab is 4.5kN/m2.
The external walls weight, superimposed dead load, the live load and f’care given in the

table below.
 Column dimensions are 0.1X and 0.1Y.

Requirements:
The following tasks shall be performed:
1. If one way ribbed slab system is used,manually draw the bending moment diagram and the
shear force diagram of the slab and an interior main beam. Dropped beams are used.
Compare the results with those obtained from a three dimensional computer model of one
story of the building. Compute the required reinforcement in the beam and slab based on SAP
results
2. If two-way solid slabwith dropped beams is used, manually draw the bending moment
diagram of an interior frame, the column strip, the middle strip and the beam in that
frame.Compare you answers with those obtained from a three dimensional computer of one
story of the building.Compute the required reinforcement in the beam and slab based on SAP
results.
3. If a voided slab with hidden beams is used, manually draw the bending moment diagram of
an interior frame, the column strip, the middle strip and the beam in that frame. Compare you
answers with those obtained from a three dimensional computer of one story of the
building.Compute the required reinforcement in the beam and slab based on SAP results.
4. Use AutoCAD to draw complete structural details for the selected slabs and beams in
the selected frame of the three systems.
5. For the voided slab with hidden beams, design:
a) The isolated footing as given in the following table assuming allowable bearing capacity of
soil = 450 kN/m2
b) A mat footing. Assume allowable bearing capacity of soil = 180 kN/m2.

Grou X Y Isolated footing SID LL Walls weight


f’c
p (m) (m) column (kN/m2) (kN/m2) (kN/m)
1 9 9 A1 5 24 5.5 16
2 9 9.5 G1 3.5 28 3 20
3 9 10 F3 4 28 4.5 18
4 9 10.5 B3 3 24 6 14
5 9 11 C5 3 32 5.5 18
6 9.5 9.5 A4 5 24 5.5 22
7 9.5 10 E2 4.5 32 6 14
8 9.5 10.5 D1 3 24 3.5 18
9 9.5 11 D7 5 28 5 16
10 10 9.5 G5 3 28 4 16
11 10 10 A6 4 32 3 22

2
12 10 10.5 E4 3.5 32 3.5 20
13 10 11 A2 4 24 6 12
14 10.5 9.5 F1 4 28 3.5 20
15 10.5 10 F4 4.5 28 3 12
16 10.5 10.5 G3 4.5 24 5 22
17 10.5 11 C7 3.5 28 4 14
18 11 11 B1 4.5 32 4 12

Report Specifications

- Font:Arial Size:11
- Linespacing:1.5lines
- Pagelayout:normal:1”top,1”bottom,1.25”leftand1.25”right

The project shall be submitted to the coordinatorno later than Thursday 3/12/2020