XKseries User v1.0 EN
XKseries User v1.0 EN
X Series / XV Series
K Series / KV Series
USER
MANUAL
www.amcelettronica.com
Index
INSTALLATION
• The installation must be performed to a professional standard by specialist personnel, respecting the
national plant engineering regulations
• The cables used for wiring, power supply and earthing must have adequate cross sections and be
IEC 60332-1-2 or IEC 60332-2-2 compliant
• The backup battery used must comply with the IEC 60896-21/2 and have a V0 fireproof casing
COMPLIANCE
AMC Elettronica declares that its alarm control panels comply with the requirements and provisions established
by directive 1999/5/CE and with the standards EN50131-1, EN50131-3, EN50131-6, EN50136-1, EN50136-2
(PSTN line , GSM, GPRS, LAN modules ATS3/SP3).
IMQ certification - Grade 2 - Class 2 security systems.
To ensure compliance with these standards, the control panels must be programmed as indicated in the specific
tables in the technical manual.
TECHNICAL VOCABULARY
Technical terms are sometimes used in this manual:
INPUT / ZONE = alarm device / detector
OUTPUT = device managed by the control panel that does not generate an alarm (e.g. light, irrigation, etc.)
MANUFACTURER
AMC ELETTRONICA
via Pascoli, 359 Loc. Mirovano
22040 Alzate Brianza (CO) Italy
[email protected]
www.amcelettronica.com
WARRANTY
AMC Elettronica reserves the right to repair or replace the defective product within the established limit of 24
months. Any use other than that indicated in this manual will invalidate the warranty.
The installation must be performed to a professional standard by specialist personnel.
ARM/DISARM AREAS/GROUPS
With the system disarmed enter the personal code (default 111111). TOTAL
The screen that will appear after entering the code is that of arming (see
12345678
fig.1). After 3 seconds activation will start automatically with counting of Fig.1
the output time. During the 3 seconds before the start of the output time it
will be possible to change the AREAS to be activated, using the G keys or
the numerical ones. Fig. 2 shows an example of AREA 1 activation. The line 0=TOT 1-8=AREA
above highlights the possible selections while the line below indicates the 1-------
Fig.2
AREA(S) selected. Fig. 3 shows the activation of 2 AREAS (1 and 2) which
correspond to a GROUP (STAY).
STAY
Note: the selection of partials is step-by-step, so pressing several 12------
times the number relating to the partial turns it on and off. Fig.3
Disarming of the system takes place via a valid USER CODE.
Note: when the EN 50131 option is activated it is not possible to arming the control panel when the following
anomalies are signalled: main power failure, low battery, tamper, tamper line, peripheral tamper, no gsm signal,
interconnection error between devices, inactivity (no awakening) radio devices.
ZONE BYPASS
There are 2 different ways to bypass zones: EXCLUSION and INHIBITION.
EXCLUSION (P) = Permanently; the zone will remain bypassed until it is re-included.
To re-include it, it will be necessary to use the specific menu.
INHIBITION (T) = Temporarily; the zone will remain bypassed only for arming of the system in progress.
After disarming the system, the zone will be automatically re-included.
Keypad display NO BYPASS ( - ) = Zone not bypassed, zone ready
NO BYPASS ( )= Zone not bypassed, zone NOT ready
X-XV Series / K-KV Series user manual v1.0 4 System management from display keypad
Bypass with zones not ready: during the arming procedure, the keypad shows the message “zones not
ready”, and proposes selecting 1 = include, 2 = inhibit, 3 = verify. When 3 is selected, the bypass menu is
highlighted (see figure).
Pressing X repeatedly allows selecting [01] ZONE 01
P or T (permanent or temporary exclusion) PT - - - - - - - - - - - - - - - - -
Bypass with system ready (all zones on standby): during the arming procedure, after having selected the
partitions, press the X key and then ENTER, to enter the bypass menu. The exclusion procedure is the same as
that described above.
When the system is armed with bypassed zones, FORCED arm occurs and in the event log it will be possible to
see which zones have been bypassed and in what way (P or T).
EVENTS MENU
The system can save 1000 events, with a rotation update system. Once the recording of 1000 events is reached,
the oldest event is automatically deleted to free up space for new events. By entering the EVENTS menu it is
possible to read all the events, grouped by type.
SYSTEM INFORMATION
The control panel has a quick menu for some general information about the system. With the control panel
disarmed, each time the "X" key is pressed, the display shows the following information in this order:
• new events menu • IP board and Internet connection status
• PSTN status • GPRS board and Internet connection status
• GSM status • Cloud connection status
• battery status • firmware version
• main power status • hardware version
X-XV Series / K-KV Series user manual v1.0 5 System management from display keypad
ENABLING INSTALLER ACCESS
Access to the programming menu by the installer must be enabled via the personal user code. Entering the user
menu, under the item ENABLE INSTALLER ACCESS it is possible to select 1 to enable or 0 to disable the installer
to access the programming menu.
ENABLE TELEMANAGEMENT
TELEMANAGEMENT Enabled 1
To delete, use the same procedure, but entering the DELETE KEYS menu. Once the user to be deleted has been
selected, press ENTER to confirm the deletion.
X-XV Series / K-KV Series user manual v1.0 6 System management from display keypad
ACTIVATION OF PROGRAMMED OUTPUTS
In this menu it is possible to ACTIVATE / DEACTIVATE previously duly
programmed OUTPUTS. Enter the menu, position on the desired output (right/
left arrows) and use the UP/DOWN arrows to activate/deactivate. ACTIVATE
The figure displays what is shown in the Menu. The outputs that can be OUTPUTS
managed are only those with 0 = deactivated and 1 = activated.
The outputs with "dash" cannot be activated because they are programmed [05] OUTPUT 05
with other functions. 0---0-------------
Once in the activation menu, use the horizontal arrow keys to switch from
[05] OUTPUT 05
one output to the other and the vertical arrows to activate or deactivate
(UP arrow = activate, DOWN arrow = deactivate) 0---1-------------
SHORTCUT KEY
The system is equipped with shortcut keys with which to perform activations (in the programming phase they must
be set by the installer).
SILENT PANIC: activated by pressing simultaneously for 2 seconds the keys G2 and G3
PANIC WITH SIREN: activated by pressing simultaneously for 2 seconds the keys G1 and G4
If there are no particular programmings, the system siren is activated.
COMMANDS ACTIVATION: holding down the corresponding number key for 2 seconds will activate the
desired command and the operation will appear on the keypad display (by commands it is meant for example
turning on lights, turning on heating etc.)
TIMER MENU
The control panel is equipped with a timer system, to arm/disarm the system automatically, to enable/disable
outputs, to enable/disable users (time slots).
Before the system is armed automatically, the user has one minute to stop the operation by entering his code.
During this minute the keypad will emit a warning beep.
In autoarming mode, the control panel will only activate if:
• all the detectors are ready
• no anomaly
The user can stop all timed operations as follows:
• enter the user menu
• go to the TIMER menu
• press enter to modify the parameter: (0 = timers disabled, 1 = timers enabled)
X-XV Series / K-KV Series user manual v1.0 7 System management from display keypad
TEST MENU
The control panel is equipped with a test tool to be able to verify the correct operation of the system, however
AMC recommends always using a professional installer to perform the test.
In the figure it is possible to view the screens to perform the siren test. Having entered the menu, use the ENTER key to activate and
deactivate the siren test.
The zones test is performed by counting down the breached zones; in the example in the figure there would still be 34 zones to be
tested. Each time an zone is unbalanced, the system decreases the counter and activates the keypad buzzer. It is possible to interrupt
the test at any time by pressing ENTER. This system is used to test all the zones without the aid of personnel, only one person is needed.
Interrupting the test lists any zones that are missing from the test.
ZONES TEST
Tot:34 V-stop
The outputs test involves selecting the desired output and activating it for 5 seconds. The figure shows the test screens. Use the ENTER
key to activate the output.
The test for voice calls will be carried out on the eighth number in the directory. The call to send the ADEMCO protocols will be made to
the first telephone number in the Contact ID list. The communicated event is the Life Test. The call is activated by pressing ENTER, wait
for the test to finish.
TEST TEST
call PSTN/GSM Contact ID PSTN/GSM
TEST TEST
Contact ID GPRS/LAN Ademco 4+2 PSTN/GSM
X-XV Series / K-KV Series user manual v1.0 8 System management from display keypad
SYSTEM MANAGEMENT VIA SMS
ARM/DISARM THE CONTROL PANEL VIA SMS
The control panel can also be armed or disarmed by sending an SMS message as follows:
LOCK=ON SYSTEM RELEASE COMMAND (to allow the installer to perform remote operations)
LOCK=OFF SYSTEM LOCK COMMAND (to inhibit the installer from remote operations)
OUT.x=1 OUTPUT ACTIVATION COMMAND (“x” corresponds to the output number)
OUT.x=0 OUTPUT DEACTIVATION COMMAND (“x” corresponds to the output number)
OUT.x? OUTPUT STATUS REQUEST (“x” corresponds to the output number)
IN.x? INPUT STATUS REQUEST (“x” corresponds to the input number)
Example:
UPWD:111111 OUT.3=1 (output 3 activation command)
X-XV Series / K-KV Series user manual v1.0 9 System management via SMS
SYSTEM MANAGEMENT VIA VOICE GUIDANCE
Only for X-XV Series
The control panel is able to provide information and guide the user through a voice-guided menu.
To access the voice menu it is necessary to contact the control panel by telephone:
1- Enter the telephone number of the control panel (the control panel will answer after a number of rings set by
the installer during programming) and follow the voice instructions.
2- Type in the personal code to access the main menu to act on the areas, to act on the remote commands and
to ascertain the status of the zones.
2.1- The voice communicates the status of the system (armed/disarmed). By pressing key 9, the total is armed/
disarmed. Subsequently, the voice communicates the status of all the other areas and it will be possible to arm/
disarm the individual areas by typing in the number corresponding to the area.
2.2- The voice communicates the name of the output and the status (activated/deactivated). Type in the number
of the output suggested by the guidance voice to change the status of the output.
2.3- The voice communicates if there are any open zones (not ready)
The control panel can send audio and SMS messages relating to system alarms and anomalies (they must be
programmed by the installer).
Messages can be sent to 1/8 telephone numbers.
The user who receives the voice message can interrupt the queue of calls to subsequent numbers in the following
ways:
• using a reset code (programmed by the installer)
• using the # symbol (it must be enabled by the installer)
If during receiving of a voice message the # is dialed, the guidance voice will ask for the personal user code and
it will be possible to enter the voice-guided menu.
X-XV Series / K-KV Series user manual v1.0 10 System management via voice guidance
SYSTEM MANAGEMENT FROM GRAPHIC KEYPAD
UNIKA is a touchscreen keypad with 5-inch screen and a thin ABS cover. Equipped with an intuitive graphic
interface it is easy to use. With just a few taps on the coloured icons it is possible to manage all the system
functions.
Fig. 1 Home
Date and time
display Arm / disarm Info task bar
Temperature
display
Reading of
events memory
Silent panic
Proximity key
Panic with siren
reading area
Calendar settings
Microphone
Recording / listening to
voice memos
Voice reminder Command SD card slot
signal badge activation
GREEN = Working
RED = Not working
GREY = Not enabled
X-XV Series / K-KV Series user manual v1.0 11 System management from graphic keypad
DATE AND TIME SETTING
Tapping the CALENDAR icon on the home page, it is possible to set the date and time of the control panel.
KEYPAD SETTINGS
By tapping the KEYPAD SETTINGS icon on the home page and entering your code, the following screen will
appear from which it is possible to set certain keypad parameters.
UNIKA has a screen saver system which can be configured to highlight a photographic sequence. To configure
the presentation it is necessary to have a micro SD memory and the “SLIDESHOW” software. To prepare the
photo file, open the software and upload the desired photos. The software generates a file that must be copied
to the SD memory. Insert the SD card in the appropriate slot provided in the UNIKA keypad, holding the card
with the contacts facing the front.
With the “+” and “-” keys it is possible to modify the waiting time (in minutes and seconds) before the screen
saver starts. Once the set time has elapsed without the keypad being used, the sequence of stored photos will
start.
X-XV Series / K-KV Series user manual v1.0 12 System management from graphic keypad
If the internal RFID has been previously enabled by the installer it is possible to program the proximity key. By
tapping the TAG key, an animation will appear prompting the action of bringing the proximity key close to the
reading area. Successful programming will be signalled by an acoustic signal and a green icon. Tapping on the
bin icon, all the proximity keys linked to the user code with which the user is logged in will be deleted.
VOICE MESSAGE
Tapping the RECORDING / LISTENING TO VOICE MEMOS icon on the home will display a screen from which it is
possible to record a reminder message.
Message
listening volume
When there is a new stored message, the icon with the red signal will appear. Select the icon to listen to the
message.
X-XV Series / K-KV Series user manual v1.0 13 System management from graphic keypad
ARM/DISARM CONTROL PANEL
During the programming phase, it is possible to activate the system without requiring any code (quick arm). This
possibility must be set by the installer.
WHITE = Working
ORANGE = Not ready
GREY= Not enabled
Tapping on a group will arm the control panel. To activate the individual areas, it will be necessary to tap on one
of the area icons and a new screen will appear with the possibility of choosing the activation. Once the selection
has been made, confirm with the enter key.
X-XV Series / K-KV Series user manual v1.0 14 System management from graphic keypad
ACTIVATION OF PROGRAMMED OUTPUTS
Tapping on the COMMAND ACTIVATION icon, the list of activated (yellow) and deactivated (white) commands
will appear on the home page. Tapping the relative key activates/deactivates the command.
It is possible, during the system programming phase, to create commands under a specific code. If there are
commands of this type, the window will show on the left the icon of a keypad through which it will be possible
to enter the code to view all the associated commands.
X-XV Series / K-KV Series user manual v1.0 15 System management from graphic keypad
READ EVENTS MEMORY
Tapping the READ EVENTS MEMORY icon on the home page prompts the typing in of your code. The list of all
the events of the control panel will appear.
Holding down the READ EVENTS MEMORY icon on the home page for 2 seconds prompts the typing in of your
code and icons will appear representing event type groups.
X-XV Series / K-KV Series user manual v1.0 16 System management from graphic keypad
SYSTEM MANAGEMENT VIA APP
AMCPlus
REGISTERING THE APP
1.1 Download the App and proceed with registration 1.2 Fill in all the required fields. Set a password
by tapping the appropriate “Sign Up” key. and press the “Sign Up” key.
1.4 Enter the code and 1.5 An e-mail 1.6 Now the App is registered and it is possible to log
press the “Sign Up” key. confirming registration in with the previously set credentials, entering them and
will be sent. tapping the “Sign In” key.
X-XV Series / K-KV Series user manual v1.0 17 System management via App
PAIRING THE CONTROL PANEL
2.1 Click on the key “+” 2.2 Fill in all the
to add the control panels. required fields: The required fields 2 - 3 - 4 in this
section must correspond to those
entered during the programming phase
by the installer.
They are found on page 21.
It is possible to delete or
modify the characteristics of
the control panels inserted
by pressing and holding the
icons of the control panels
themselves.
3.1 To access the system management, click on the control panel icon and then enter the personal code
(default 111111 - only editable from the keypad).
The control panel icon will have
different types of colour depending
on the status:
GREY: everything ok
YELLOW: problem (low battery,
no power supply, etc.)
RED: alarm
X-XV Series / K-KV Series user manual v1.0 18 System management via App
3.2 Use the appropriate 3.3 Clicking on the arrow accesses the sections where it is possible to
key to arm the system in arm/disarm the GROUPS and the AREAS, to exclude/include the ZONES
total way. and activate/deactivate the OUTPUTS.
3.4 Use the
appropriate key to
arm the individual
Group.
By clicking on the
3.5 Clicking on the arrow 3.6 Clicking on the arrow it triangular icon it
The GROUPS and AREAS it is possible to access is possible to access the is possible to view
icons take on different the Areas belonging to Zones and Outputs belonging the anomalies.
colours depending on the relevant Group. to the relevant Area.
the status:
disarmed
armed
system
in alarm
open zone
or anomalies
The icons of the ZONES and OUTPUTS take on different colours depending on the status:
zone zone zone output
excluded ready in alarm deactivated
zone zone output
included not ready activated
X-XV Series / K-KV Series user manual v1.0 19 System management via App
3.7 Clicking on the individual GROUPS, AREAS, ZONES, OUTPUTS
accesses a screen on which to assign an image (allow access to
the camera).
Clicking on the appropriate
button it is possible to view
the icons of the GROUPS,
AREAS, ZONES, OUTPUTS
on the map and act directly
from this screen.
VIDEO VERIFICATION
video
zone
4.1 Clicking on the REC icon it is possible to 4.2 From the NOTIFICATIONS 4.3 By clicking on the
activate a video recording and subsequently section, by clicking on any appropriate key it is
receive it on the App. When the video is video notification, it is possible possible to download
available, a PUSH will be sent (average receiving to access the list of available the video in the photo
time 1 minute). videos. gallery of the phone.
X-XV Series / K-KV Series user manual v1.0 20 System management via App
OTHER FUNCTIONS
NOTIFICATIONS menu
Through this menu it is possible
to receive the following default
notifications: alarms and anomalies
INSTALLER SPACE
X-XV Series / K-KV Series user manual v1.0 21 System management via App
NOTES
AMC Elettronica
Via Pascoli, 359 - 22040 Alzate Brianza (CO) Italy
[email protected] - www.amcelettronica.com
Due to the continuous improvement of its products, AMC reserves the right to modify or replace technical specifications and
information contained in this manual without prior notice.