0% found this document useful (0 votes)
16 views12 pages

Acero Electrico

Uploaded by

Juan Blanco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views12 pages

Acero Electrico

Uploaded by

Juan Blanco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

NON-ORIENTED

ELECTRICAL
STEELS

Born from fire,


made to
endure
ACRONI, d.o.o.,
located in Jesenice, Slovenia, is a member
of SIJ - SLOVENIAN STEEL GROUP, D. D

Long years of experience in fields


of development and production have
enabled us to offer our customers
the majority of standard grades
of electrical steels being
produced in the world today.
Constant development, improvement
of processes and materials along
with the introduction of a quality
assurance system in accordance with
ISO 9001,
environmental management
systems in accordance with
ISO 14001
and occupational health and safety
management systems in
accordance with
OHSAS 18001,
are our guarantee for a
constant quality level.
steel
NON-ORIENTED FULLY-PROCESSED ELECTRICAL STEELS

Electrical steels have

special physical properties which

make them suitable for

application in the manufacture

of electric equipments and

appliances with rotating

magnetic fields. The utilisation

of fully processed steels is also

widespread for construction of

electrical static devices. Without

electrical steels the production,

transformation and utilisation

of electrical energy would not

be practical and would

prove uneconomic.
B O R N F R O M F I R E , M A D E T O E N D U R E

CO L D R O L L E D F U L LY- P R O C ESS E D E L ECT R I CA L ST E E L S

Cold rolled fully-processed electrical steels may be delivered without insulation or insulated on both sides
with insulation in order to achieve desired properties for various fields of application (higher surface
insulation resistance, improvement of punchability and corrosion resistance, annealing).

F U L LY- P R O C E S S E D E L E C T R I C A L S T E E L S - D I N A M O
( G U A R A N T E E D VA L U E S )

Grade Nominal Specific total loss 1), 4) Magnetic polarisation (min.) Stacking Density
thickness (max.) for field strength A/m 2),4) factor (assumed)
EN 10106 (mm)
at 1.5T at 1T 3 ) 2500 5000 10000 (min.) (kg/dm 3 )
(W/kg) (W/kg) (T) (T) (T)

M270-35A 2,7 1,10 1,49 1,60 1,70 7,65

M300-35A 0,35 3,0 1,20 1,49 1,60 1,70 0,95 7,65

M330-35A 3,3 1,30 1,49 1,60 1,70 7,65

M310-50A 3,1 1,25 1,49 1,60 1,70 7,65

M330-50A 3,3 1,35 1,49 1,60 1,70 7,65

M350-50A 3,5 1,50 1,50 1,60 1,70 7,65

M400-50A 4,0 1,70 1,53 1,63 1,73 7,70

M470-50A 0,50 4,7 2,00 1,54 1,64 1,74 0,97 7,70

M530-50A 5,3 2,30 1,56 1,65 1,75 7,70

M600-50A 6,0 2,60 1,57 1,66 1,76 7,75

M700-50A 7,0 3,00 1,60 1,69 1,77 7,80


M800-50A 8,0 3,60 1,60 1,70 1,78 7,80
M350-65A 3,5 1.50 1,49 1,60 1,70 7,60
M400-65A 4,0 1,70 1,52 1,62 1,72 7,65
M470-65A 4,7 2,00 1,53 1,63 1,73 7,65
M530-65A 0,65 5,3 2,30 1,54 1,64 1,74 0,97 7,70
M600-65A 6,0 2,60 1,56 1,66 1,76 7,75
M700-65A 7,0 3,00 1,57 1,67 1,76 7,75
M800-65A 8,0 3,60 1,60 1,70 1,78 7,80

1) In accordance with IEC 60404-8-4 and EN 10106, the values are specified and guaranteed for magnetic polarisation at 1.5 T unless otherwise agreed
2) In accordance with IEC 60404-8-4 and EN 10106, the values are specified and guaranteed for field strength at 2500 A/m, 5000 A/m and 10000 A/m unless
otherwise agreed
3) These are only informative values
4) Valid for testing in A. C. field in the 25 cm Epstein frame according to IEC 60404-2
B O R N F R O M F I R E , M A D E T O E N D U R E

FU L L Y - P R O C E S S E D H I G H P E R M E A B I L I T Y E L E C T R I C A L S T E E L S - P E R M A G F P
(G U A RA N TE E D VA L U E S)

ACRONI Nominal Specific total loss 2) Magnetic polarisation (min.)


Grade thickness (max.) for field strength A/m 2)
(mm)
PERMAG at 1.5T at 1T 1 ) 2500 5000 10000
(W/kg) (W/kg) (T) (T) (T)

M330-35A-HP 0,35 3,30 1,30 1,55 1,64 1,76

M400-50A-HP 4,00 1,70 1,61 1,70 1,81

M530-50A-HP 0,50 5,30 2,30 1,63 1,72 1,83

M600-50A-HP 6,00 2,60 1,64 1,73 1,84

M700-50A-HP 7,00 3,00 1,67 1,76 1,78

M470-65A-HP 4,70 2,00 1,58 1,67 1,79

M600-65A-HP 6,00 2,60 1,62 1,71 1,82


0,65
M700-65A-HP 7,00 3,00 1,65 1,73 1,84

M800-65A-HP 8,00 3,60 1,67 1,76 1,87

1) These are only informative values


2) Valid for testing in A. C. field in the 25 cm Epstein frame according to IEC 60404-2

I N S U L A T I O N CO A T I N G S O N F U L L Y- P R O C E S S E D E L E C T R I C A L S T E E L S

AISI Designation C-6 C-3 C-5


ASTM A976

TYPE OF INSULATION L1 L2 L3
(Acroni designation)

THERMAL CLASS H H H
(IEC 60085)

THICKNESS OF LAYER ON 1 to 6 0,5 to 3 0,5 to 1,5


EACH SIDE 1,5 to 3,0
(µm) (ISO 2178)

COMPOSITION ORGANIC WITH FILLERS ORGANIC WITHOUT FILLERS ORGANIC/INORGANIC


WITH FILLERS

SURFACE INSULATION 40 to 500 up to 15 5 to 70


RESISTANCE 1)
(Ohm cm 2) (ASTM A717)

HEAT RESISTANCE 180˚C 2) 180˚C 2) 180˚C 2) / 850˚C 3)

INFLUENCE ON FAVOURABLE VERY FAVOURABLE VERY FAVOURABLE


PUNCHABILITY

INFLUENCE ON CONDITIONAL CONDITIONAL GOOD


WELDABILITY

RESISTANCE TO MEDIUM 4)
GOOD GOOD GOOD

COLOUR 5)
LIGHT GREY TO DARK GREY YELLOW COLOURLESS TO GREEN
LIGHT GREY TO DARK GREY

1) Surface insulation resistance depends on coating thickness


2) In air long time (testing for 20000 hours at a given temperature in accordance with IEC 60085)
3) In protective gas atmosphere (as stress-relief annealing)
4) It relates to the resistance to the most of lubricants, refrigerating mediums and oils. The varnish producer tests the resistance to the specific medium
only after the customer’s requirement
5) Colour shades depend on the coating thickness and type of varnish applied
B O R N F R O M F I R E , M A D E T O E N D U R E

CO M PA R I S O N O F G RA D E D ES I G N AT I O N S

F U L LY- P R O C E S S E D E L E C T R I C A L S T E E L S

EN 10106 IEC JIS GOST*


(2007) 60404-8-4 AISI* C 2552 21 427
(1998) (2000) 0-75

M250-35A M250-35A 5 M 15 35A250 2411

M270-35A M270-35A 5 M 19 35A270 2412

M300-35A M300-35A 5 M 22 35A300 2411

M330-35A M330-35A 5 M 36 --- ---

M330-50A M330-50A 5 M 27 --- ---

M350-50A M350-50A 5 M 36 50A350 2411

M400-50A M400-50A 5 M 43 50A400 2312

M470-50A M470-50A 5 --- 50A470 2311

M530-50A M530-50A 5 M 45 --- 2212

M600-50A M600-50A 5 --- 50A600 2112

M700-50A M700-50A 5 M 47 50A700 ---

M800-50A M800-50A 5 --- 50A800 2111

M400-65A M400-65A 5 M 27 --- ---

M470-65A M470-65A 5 M 43 --- ---

M530-65A M530-65A 5 --- --- 2312

M600-65A M600-65A 5 M 45 --- 2212

M700-65A M700-65A 5 --- --- 2211

M800-65A M800-65A 5 --- 65A800 2112


B O R N F R O M F I R E , M A D E T O E N D U R E

GRADES OF NON-ORIENTED ELECTRICAL STEELS SUITABLE


FOR VARIOUS APPLICATIONS

M270-35A to M330-35A M470-50A to M600-50A M700-50A to M800-50A


APPLICATION M310-50A to M400-50A M470-65A to M600-65A M700-65A to M800-65A
M350-65A to M400-65A

Large rotating machines •


(2 and 4 poles)
ROTATING MACHINES

Large rotating machines •


(many poles)

Small generators • •
Medium rotating machines

Hermetic motors • • •

General duties A.C. electric • •


motors, domestic appliance
motors

Small D.C. intermittent • • •


motors, compressor motors

Audio transformers • • •

Saturable reactors and • •


magnetic amplifiers

Voltage regulator •
transformers, distribution
transformers
STATIC MACHINES

Power transformers •

Current transformers •

Welding transformers • • •

Fluorescent lamp ballasts • • •

Magnetic switches •

Pole pieces and relay cores •


B O R N F R O M F I R E , M A D E T O E N D U R E

GENERAL INFORMATION

STRIPS
Width of coil 30 do 1000 mm
Inside nominal diameter 508 mm (20")
Outside nominal diameter 1300 mm (max)

Dimensions and weights


Coil weight Outside diameter
(kg/mm of width) (mm)
Entire coil 6 to 8,6 1100 to 1300
1/2 coil 3 to 4,5 870 to 1000
1/3 coil 2 to 2,9 770 to 850

Tolerances
TOLERANCES ON NOMINAL WIDTH TOLERANCES ON NOMINAL THICKNESS

Nominal width “w“ Tolerance Nominal thickness Tolerance


(mm) (mm) (mm) (mm) %
w ≤ 150 0 to +0,2 0,35 ±0,03 ±8
150 < w ≤ 300 0 to +0,3 0,50 ±0,04 ±8
300 < w ≤ 600 0 to +0,5 0,65 ±0,04 ±6
600 < w ≤ 1000 0 to +1,0 1,00 ±0,06 ±6

SHEETS
Cut lengths 600 to 6000 mm
Cut length tolerances 0 do + 0,5%
Widths of sheets 420 do 1000 mm
Package weights 1000 do 2500 kg
Dimensional and geometrical tolerances are in accordance with standards EN 10106, EN 10341
B O R N F R O M F I R E , M A D E T O E N D U R E

OUTSIDE DIAMETER IN DEPENDENCE OF COIL WEIGHT

Strip width (mm)

25 50 100 200 300 400 500


1300

600 350
1200

700
1100 300
800

900
1000 250
Outside diameter (mm)

1000

Coil thickness (mm)


900 200

800 150

700 100

600 50

Density: 7,75 kg/dm 3


Inside diameter: 508 mm
500 0

400
0 500 1000 1500 2000 2500 3000 3500 4000 4500

Coil weight (kg)


Acroni d.o.o.
C. Borisa KidriËa 44
4270 Jesenice, Slovenija
Tel.: +386 4 584 10 00
Faks: +386 4 584 11 11
www.acroni.si

Publisher: ACRONI, d. o. o., Jesenice • Text: Acroni R&D • Production: RD BORGIS • AD/D: Matjaæ Lazar, XLMS • Photographs: P. Marinπek • Jesenice 2013
A C R O N I I S T H E L A R G E S T S L O V E N I A N S T E E L M A N U FA C T U R E R , W H I C H I N O R D E R
TO PRODUCE STEEL RECYCLES SCRAP IN AN ELECTRIC ARC FURNACE, CASTS IT ON
C O N T I N U O U S C A S T E R A N D R O L L S I T I N T O Q U A L I T Y F L AT- R O L L E D S T E E L P R O D U C T S .
T H E C O M PA N Y I S S P EC I A L I S E D FO R T H E P R O D U C T I O N O F F L AT S T E E L P R O D U C T S ,
E S P E C I A L LY S T A I N L E S S , S T R U C T U R A L , E L E C T R I C A L A N D S P E C I A L S T E E L S , T H A T
M E E T T H E D E M A N D I N G R E Q U I R E M E N T S O F G L O B A L S T E E L M A R K E T.

You might also like