800-03612 1/09 Rev.

ADEMCO 6460S/6460W
6460S/6460W
REMOTE KEYPAD
INSTALLATION AND SETUP GUIDE

GENERAL INFORMATION WIRING AND INSTALLATION


The ADEMCO 6460S (silver) and 6460W (white) are The keypads can be surface mounted directly to a drywall,
addressable Remote Keypads designed for use with or to a single- or double-gang electrical box.
Honeywell's ADEMCO series control panels. Addresses are 1. Push the two case release snaps at the bottom of the
set via the keypad keys. keypad with the blade of a medium screwdriver (this will
The keys on the keypad are continuously backlit for push in the release snap), then pull that side of the case
convenience. back away. Refer to Figure 1 for location of the case back
NOTE: If supported, the ADEMCO 6460S and 6460W release snaps.
keypads are supervised by control panel. Supervision must 2. Route wiring from the control panel through the opening
be enabled for commercial fire installations. in the case back.
3. Mount the case back to a wall or electrical box.
KEYPAD DISPLAYS AND LEDS 4. Wire directly from the keypad’s terminal block to the
The ADEMCO 6460S and 6460W keypads have the terminal block on the control panel. (See Wiring Table
following display features: below).
• 2-line Alpha Display
• Custom Zone Descriptors NOTE: No more than one wire per terminal may be
• Built-in Speaker Sounder connected. If daisy-chained configuration is required,
• Dedicated Function Keys pig-tail wires together so that only one wire is
terminated under the screw. Use 16-24 AWG wire only!
• Backlit Display (permanent display backlighting is
an option on some controls; see the control's Wiring Table
instructions for details). Keypad Control Panel Wire Color
▲G Data In Green
The following table shows the LEDs and their functions:
– – Aux Pwr (GND) Black
LED Function + + Aux. Pwr Red
Red Lights when the system is armed in any mode ▼Y Data Out Yellow
Green Lights when the system is "ready" to be armed. See the control panel’s Installation and Setup Guide for
more complete details.
5. Reattach the keypad to its case back.
SPECIAL FUNCTION KEYS A B C D
The keypads also feature function keys. These keys may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.

Function keys must be held down for at least 2


seconds to activate an alarm; key pairs are activated
immediately. ARMED

READY
1
OFF
2 ABC
AWAY
3 DEF
STAY

4 GH I 5 JKL 6 MNO
MAX TEST BYPASS

7PQRS 8 TUV 9 WXYZ


INS TAN T CODE CH I ME

Function Keys * END


R EADY
0 # NUM

A or [1] and [✻]


B or [✻] and [#] NOTE:
TO REMOVE CASE BACK
PUSH IN THE TWO RELEASE
C or [3] and [#] SNAPS LOCATED ALONG THE
BOTTOM OF THE KEYPAD
D AND LIFT UP.
RELEASE
SNAPS
6460S-001-V1

Figure 1. Removing the Case Back

WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
SETTING THE KEYPAD ADDRESS FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
The keypad can either be set for an address of 00-30, or to symbols (i.e., fire, police, personal emergency, etc.) is
the non-addressable mode (31). The keypad's default provided. These labels can be placed on or next to the keys
address is 31. to identify each key's function for the end user (as
To change the keypad's address, do the following: determined by the control panel's capability and
1. Enter address mode: Power up the keypad. Within 60 programming; see the control's instructions).
seconds of power-up, press and hold down the [1] and [3]
keys at the same time for 3 seconds. (If unable to enter
OPERATING THE KEYPAD
address mode, power up and try again.)
For operating instructions, see the User Guide for the
The current keypad address will be displayed, and the
control panel used with this keypad.
cursor will be under the "tens" digit. If 10 seconds have
passed with no key entry, the keypad automatically exits SPECIFICATIONS
address mode. You must power down, power up and Physical: 5-9/16"H x 6-3/4"W x 1"D
start address mode again.
NOTE: The keypad will not enter address mode if the
Displays: 2 x 16 alpha-numeric supertwist LCD,
panel to which it is connected is in programming mode.
backlit.
2. Set the current address to "00": Press [0] to clear the
current "tens" digit. The cursor will move to the "ones"
digit position. Press [0] to clear the current "ones" digit. Sounder: Speaker.
The cursor will move back to the "tens" digit position.
Voltage: 12VDC (power-limited)
3. Enter the keypad's address: Enter the proper "tens" digit
of the keypad's address. The cursor will move to the
Current: 150mA in alarm (ARMED LED lit, LCD
"ones" digit position. Enter the proper "ones" digit of the
backlight and sounder on), reduces to 40mA
keypad's address. Note that address "31" sets the
when panel is operating in standby mode
keypad to non-addressable mode.
(backlight off).
4. Exit address mode:
Press [✻] to save the displayed address and exit address NFPA-72 Compliant.
mode.
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] and [3] keys at the same time
for about 3 seconds. The current address is displayed. No
key entry is allowed. Press any key to exit or wait 10
seconds to exit viewing mode.

REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY
INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.