ADEMCO 6150V & 6160V


Voice Remote Keypads
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION Function Equivalent Key Pairs
The ADEMCO 6150V and ADEMCO 6160V are addressable Keys
A [1] and [*]
remote keypads designed for use with ADEMCO control
B [*] and [#]
panels and provide the following features:
C [3] and [#]
• Backlit Display • Voice Chime D NONE
• Programmable Function • Voice Status
Keys • Message Center • Function keys must be held down for at
• Built-in Sounder least 2 seconds to activate the programmed
Notes: function.

• When used with the ADEMCO VISTA-15P/VISTA- • If functions other than panics are assigned
to the programmable function keys,
20P control panels, address 16 must be assigned to
programmed panics must be initiated by
the first keypad. Additional keypads must be pressing the programmed key pair.
assigned to address 17 – 23. Refer to Setting The
Keypad Options. FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
• Keypad keys are continuously backlit for convenience.
symbols (i.e., fire, police, personal emergency, etc.) is
• Permanent display backlighting is an option on some provided. These labels can be placed on or next to the keys
controls (refer to the control panel’s instructions for to identify each key's function for the end user (as
details). determined by the capability and programming of the
• Voice Chime should only be enabled when used with control panel; refer to the installation and setup guide for
control panels that support the "chime by zone" mode the control panel).
(e.g., VISTA-15P/VISTA-20P). This mode must be
enabled at the control panel. Refer to the control panel's
installation and setup guide for information on how to
program the chime mode. A
• Use only zone descriptors supported by this ARMED 1 2 3
B OFF

RECORD
AWAY

VOLUME
STAY

PLAY
keypad. If using zone descriptors not supported READY 4 MAX 5 TEST 6 BYPASS SIDE
by this keypad, you must turn voice status and VIEW
MESSAGE 7 INSTANT 8 CODE 9 CHIME

voice chime off. Table 1 is a list of applicable zone


C MIC READY 0 #
descriptors and index entries. Refer to the control STATUS VOICE FUNCTION

panel’s installation and setup guide for information D


about how to program zone descriptors.
KEYPAD DISPLAYS AND LEDS

6160V-001-V1
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
The keypads have the following display features: the keypad's bottom edge and pulling the case apart.)

Model Fixed 2-Line 2-Digit Custom WIRING AND INSTALLATION


Word Alpha Zone Zone Keypads can be surface mounted using drywall anchors or
Display Display Identifier Descriptors
to a single- or double-gang electrical box.
6150V X X
1. Remove the case back by pushing up the two "snaps"
6160V X X along the keypad’s bottom edge and pulling the case
The following table identifies the keypad’s LEDs and apart. See diagram above.
associated functions: 2. Route wiring from the control panel through the
LED Function opening in the case back.
ARMED Lights red when the system is armed in any mode. 3. Mount the case back to a wall or electrical box.
READY Lights green when the system is "ready" to be 4. Wire directly from the keypad’s terminal block to
armed. the terminal block on the control board. (See Wiring
MESSAGE Flashes red when message waiting or lights red Table that follows.)
(steady) when in record mode. Wiring Table (All Keypads)
PROGRAMMABLE FUNCTION KEYS Keypad Control Panel Wire Color
°G Data In Green
The keypad's programmable function keys [A, B, C] are
– – Aux Pwr (GND) Black
normally used for keypad panic functions, but they can be
programmed for other special functions instead. If they are + + Aux. Pwr Red
programmed for other special functions, the associated ±Y Data Out Yellow
keypad key pairs still provide the respective panic alarm (if 5. Re-attach the keypad to the case back.
programmed). Refer to the control panel’s Installation & 6. Remove clear protective film from LEDs (6160V
Setup Guide for details. only).

WWW.DIYALARMFORUM.COM
SETTING THE KEYPAD OPTIONS "ADDITIONAL CON" (alpha keypad) or "A" (fixed
The procedures that follow are used to set the keypad keypad) is displayed along with the selected mode "1" or
address, voice chime mode, and additional voice keypad "0".
mode. Note: Setting Voice Chime mode off does not effect the
Setting The Keypad Address voice status or alarm annunciation.
When used with the VISTA-15P/VISTA-20P Setting The Additional Console Mode
control panels, address 16 must be assigned to The Additional Console mode must be set for all voice
the first Keypad. Additional Keypads must be keypads being used.
set at 17 - 23 and must be enabled additionally
in control programming (fields *190 - *196). 8. Set the voice keypad Additional Console mode as
follows:
The keypad can either be set for an address of 00-30 or for
a. On the Primary voice keypad, press [0] to set the
non-addressable mode (31). The default keypad address is
Additional Console mode to NO.
31. For valid address settings for your keypad, refer to the
b. On any secondary voice keypads, press [1] to set
control panel's Installation & Setup Guide.
Additional Console mode to YES.
Note:
9. Press [✱] to save the mode.
• If unable to enter the address mode, power down,
power up, and try again. VIEWING THE KEYPAD ADDRESS
• If 10 seconds pass with no key entry, the keypad Press and hold down the [1] key and [3] key at the same
automatically exits the address mode. You must time for about 3 seconds. The current address is displayed.
power down, power up, and start the address mode No key entry is allowed. Press any key to exit or wait 10
again. seconds to exit the viewing mode.
• The keypad will not enter the address mode if the SPECIFICATIONS
control panel is in programming mode. Physical:
1. Apply power to the keypad. 6150V: 4-7/8"H x 6-1/4"W x 1"D
2. Within 60 seconds of applying power to the keypad, press 6160V: 5-5/16"H x 7-3/8"W x 1-3/16"D
and hold down the [1] key and [3] key at the same time
Displays:
for 3 seconds. The current keypad address will be
displayed. 6150V: Fixed-Word LCD (backlit)
3. Press "00". 6160V: 2 x 16 Alpha-Numeric Super twist LCD
(backlit)
The current address is cleared.
Sounder: Speaker
4. Enter desired keypad address.
Electrical:
5. Press [✱] to save the displayed address and enter the
Voice Chime mode. "VOICE CHIME" (alpha keypad) or Voltage: +12VDC
"C" (fixed keypad) is displayed along with the selected Current:
mode "1" or "0". 6150V: 160mA (ARMED LED lit, LCD backlight
Setting The Voice Chime Mode and sounder on) reduces to 60mA when
6. Press [1] to set the Voice Chime mode on or press [0] to panel is operating in standby mode
set the Voice Chime mode off. (backlight off).
7. Press [✱] to save the displayed Voice Chime mode and 6160V: 190mA (ARMED LED lit, LCD backlight
enter the Additional Console voice keypad mode. and sounder on) reduces to 60mA when
panel is operating in standby mode
(backlight off).

TABLE 1. ZONE DESCRIPTORS AND INDEX ENTRIES


ALARM 002 DOOR 057 KITCHEN 105 PATIO 146 UPSTAIRS 207
ATTIC 009 EMERGENCY 067 LAUNDRY 106 POLICE 151 UTILITY 208
BABY 012 EXIT 071 LIBRARY 109 POOL 152 WINDOW 217
BACK 013 FIRE 079 LIVING 113 ROOM 162 YARD 223
BASEMENT 016 FLOOR 080 MAIN 122 SHED 168 ZONE 225
BATHROOM 017 FRONT 085 MASTER 123 SHOP 170 1ST 228
BEDROOM 019 GARAGE 089 MEDICAL 125 SIDE 173 2ND 230
CLOSED 040 GUN 094 MOTION 131 SLIDING 175 3RD 232
DEN 050 HALL 095 OFFICE 136 SMOKE 176
DETECTOR 052 HOUSE 099 OPEN 138 STORAGE 185
DINING 053 INSIDE 101 PANIC 144 SUPERVISED 190

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR