6150v-6160v-install
6150v-6160v-install
6150v-6160v-install
• When used with the ADEMCO VISTA-15P/VISTA- • If functions other than panics are assigned
to the programmable function keys,
20P control panels, address 16 must be assigned to
programmed panics must be initiated by
the first keypad. Additional keypads must be pressing the programmed key pair.
assigned to address 17 – 23. Refer to Setting The
Keypad Options. FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
• Keypad keys are continuously backlit for convenience.
symbols (i.e., fire, police, personal emergency, etc.) is
• Permanent display backlighting is an option on some provided. These labels can be placed on or next to the keys
controls (refer to the control panel’s instructions for to identify each key's function for the end user (as
details). determined by the capability and programming of the
• Voice Chime should only be enabled when used with control panel; refer to the installation and setup guide for
control panels that support the "chime by zone" mode the control panel).
(e.g., VISTA-15P/VISTA-20P). This mode must be
enabled at the control panel. Refer to the control panel's
installation and setup guide for information on how to
program the chime mode. A
• Use only zone descriptors supported by this ARMED 1 2 3
B OFF
RECORD
AWAY
VOLUME
STAY
PLAY
keypad. If using zone descriptors not supported READY 4 MAX 5 TEST 6 BYPASS SIDE
by this keypad, you must turn voice status and VIEW
MESSAGE 7 INSTANT 8 CODE 9 CHIME
6160V-001-V1
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
The keypads have the following display features: the keypad's bottom edge and pulling the case apart.)
WWW.DIYALARMFORUM.COM
SETTING THE KEYPAD OPTIONS "ADDITIONAL CON" (alpha keypad) or "A" (fixed
The procedures that follow are used to set the keypad keypad) is displayed along with the selected mode "1" or
address, voice chime mode, and additional voice keypad "0".
mode. Note: Setting Voice Chime mode off does not effect the
Setting The Keypad Address voice status or alarm annunciation.
When used with the VISTA-15P/VISTA-20P Setting The Additional Console Mode
control panels, address 16 must be assigned to The Additional Console mode must be set for all voice
the first Keypad. Additional Keypads must be keypads being used.
set at 17 - 23 and must be enabled additionally
in control programming (fields *190 - *196). 8. Set the voice keypad Additional Console mode as
follows:
The keypad can either be set for an address of 00-30 or for
a. On the Primary voice keypad, press [0] to set the
non-addressable mode (31). The default keypad address is
Additional Console mode to NO.
31. For valid address settings for your keypad, refer to the
b. On any secondary voice keypads, press [1] to set
control panel's Installation & Setup Guide.
Additional Console mode to YES.
Note:
9. Press [✱] to save the mode.
• If unable to enter the address mode, power down,
power up, and try again. VIEWING THE KEYPAD ADDRESS
• If 10 seconds pass with no key entry, the keypad Press and hold down the [1] key and [3] key at the same
automatically exits the address mode. You must time for about 3 seconds. The current address is displayed.
power down, power up, and start the address mode No key entry is allowed. Press any key to exit or wait 10
again. seconds to exit the viewing mode.
• The keypad will not enter the address mode if the SPECIFICATIONS
control panel is in programming mode. Physical:
1. Apply power to the keypad. 6150V: 4-7/8"H x 6-1/4"W x 1"D
2. Within 60 seconds of applying power to the keypad, press 6160V: 5-5/16"H x 7-3/8"W x 1-3/16"D
and hold down the [1] key and [3] key at the same time
Displays:
for 3 seconds. The current keypad address will be
displayed. 6150V: Fixed-Word LCD (backlit)
3. Press "00". 6160V: 2 x 16 Alpha-Numeric Super twist LCD
(backlit)
The current address is cleared.
Sounder: Speaker
4. Enter desired keypad address.
Electrical:
5. Press [✱] to save the displayed address and enter the
Voice Chime mode. "VOICE CHIME" (alpha keypad) or Voltage: +12VDC
"C" (fixed keypad) is displayed along with the selected Current:
mode "1" or "0". 6150V: 160mA (ARMED LED lit, LCD backlight
Setting The Voice Chime Mode and sounder on) reduces to 60mA when
6. Press [1] to set the Voice Chime mode on or press [0] to panel is operating in standby mode
set the Voice Chime mode off. (backlight off).
7. Press [✱] to save the displayed Voice Chime mode and 6160V: 190mA (ARMED LED lit, LCD backlight
enter the Additional Console voice keypad mode. and sounder on) reduces to 60mA when
panel is operating in standby mode
(backlight off).
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR
WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
www.honeywell.com/security
¬.9l WWW.DIYALARMFORUM.COM