0% found this document useful (0 votes)
12 views

Instrumentation and Process Addendum

Uploaded by

shubham
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views

Instrumentation and Process Addendum

Uploaded by

shubham
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Addendum

Sl. File & Clause no. To be read as


No.
Instrumentation
1 30 Vol 3B Sec 4 5 Instt Specs Cl No. 1.3.2 Compressibility factor of gas – 0.99
Compressibility factor of gas – 0.98

2 30 Vol 3B Sec 4 5 Instt Specs Cl No. 5.3


Maximum Pressure drop across the filter-
Maximum Pressure drop across the filter-0.1
0.2 KSC
KSC
3 30 Vol 3B Sec 4 5 Instt Specs Cl No 5.2.6 The Gas Chromatograph shall distinguish the
The Gas Chromatograph shall distinguish the following components of natural gas: C1, C2,
following components of natural gas: C1, C2, C3, iC4, nC4, iC5, nC5, C6+, CO2, N2, H2S,He
C3, iC4, nC4, iC5, nC5, C6+, CO2, N2, H2S, & H2.
A)
4 30 Vol 3B Sec 4 5 Instt Specs Cl No 5.2.6 The Gas Chromatograph shall calculate
The Gas Chromatograph shall calculate Heating Value, Specific Gravity, Calorific
Heating Value, Specific Gravity, Calorific Value and Wobbe Index per GPA 2145/ 2172
Value and Wobbe Index per GPA 2145/ 2172 for gas at standard conditions of 1.0332
for gas at standard conditions of 1.0332 kg/cm2 abs and 15.56 oC. The calculated Kcal
kg/cm2 abs and 15.56 oC. The calculated values shall have an accuracy of 0.1%,
Kcal values shall have an accuracy of 0.1%, exclusive of calibration standard accuracy.
exclusive of calibration standard accuracy. Repeatability shall be ±0.5 Kcal per 1000 Kcal
Repeatability shall be ±0.5 Kcal per 1000 (0.05%).
Kcal (0.05%). B) Input / out of Gas chromatograph shall also
have provision of calorific value and
compressibility factor.

Process
5 03 Vol 2 Sec 2 1 Surface Facilities SOW Cl C) All place in the Process Scope of Work,
no 2.1.1 “Effluent Water” shall be read as “Produced
Process Scope of Work Water”