DIAGNOSTIC ULTRASOUND SYSTEM

Product Data
No. MPDUS0212EAC

Prism Edition
INTRODUCTION
This system achieves high sensitivity and high quality by
using state-of-the-art digital technology in the T/R section,
which is the core of a diagnostic ultrasound system.
This system features advanced algorithms that run on cir-
cuits that incorporate the latest circuit technology, semicon-
ductor technology, and surface-mount technology.
This system is designed to support a full range of applica-
tions and can be used as a general purpose system or a spe- 2,1 a 2,9
cialized system, depending on the installed software.

Full-digital ultrasound beam transmission and


reception 4 5
This system employs full-digital transmission and reception
circuits. The high definition ultrasound beams and data pro-
cessing technology available with full-digital systems allow
high sensitivity and image quality to be achieved simultane-
ously.

Enhanced diagnostic capabilities


The spatial resolution, contrast resolution, and temporal res-
olution have been improved through new technologies,
resulting in enhanced diagnostic capabilities.

Transducers supporting a wide range of frequen-


cies
Echoes over a wide range of frequencies can be obtained
using a single transducer, allowing the optimal sensitivity
and quality to be achieved for each region examined. This
function permits a single transducer to be utilized for a wide
range of applications, greatly improving the throughput and
price-to-performance ratio.

Intelligent panel and software


The intelligent panel and software facilitate operation and
contribute to a higher throughput.

Upgradability 28,2 28,9,5


This system can be periodically upgraded to the latest ver- 28,3
sion. 31

Ergonomics Operability
The system employs a non-interlace high-definition monitor System operability is optimized for the overall clinical work-
with excellent view ability. This feature decreases operator flow in hospitals.
fatigue in long examinations.
The ergonomic design of the system ensures comfortable
and efficient examinations for operators, physicians, and
patients.
Prism Edition

SYSTEM MATRIX OF TUS-AI900/TUS-AI800/TUS-AI700


Unit Model name Remarks
23-inch wide LCD monitor, DVD/CD drive, Precision Imaging, D-THI, ApliPure+, Tissue Specific Optimization, Trapezoid Scan, Quick
TUS-AI900 Scan, Advanced Dynamic Flow (ADF), DICOM, Smart 3D, Software full keyboard, Vascularity Index, BEAM, Superb micro-vascular
Aplio i900 Imaging (SMI), Intelligent Dynamic Micro Slice, AppLocker® Security Management, Volume Matrix, Probe connector holder, and
electric lifting of the operation panel are included.

23-inch wide LCD monitor, DVD/CD drive, Precision Imaging, D-THI, ApliPure+, Tissue Specific Optimization, Trapezoid Scan, Quick
TUS-AI800 Scan, Advanced Dynamic Flow (ADF), DICOM, Smart 3D, Software full keyboard, Vascularity Index, BEAM, Superb micro-vascular
Main unit
Aplio i800 Imaging (SMI), Intelligent Dynamic Micro Slice, AppLocker® Security Management, Probe connector holder, and electric lifting of
the operation panel are included.

23-inch wide LCD monitor, DVD/CD drive, Precision Imaging, D-THI, ApliPure+, Tissue Specific Optimization, Trapezoid Scan, Quick
TUS-AI700
Aplio i700
Scan, Advanced Dynamic Flow (ADF), DICOM, Smart 3D, Software full keyboard, Vascularity Index, BEAM, Superb micro-vascular
Imaging (SMI), Intelligent Dynamic Micro Slice, AppLocker® Security Management, connector holder, and electric lifting of the
8
operation panel are included.

<Options for main unit>


Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health
USCW-AI900A, For cardiovascular examinations, add Continuous Doppler capability to sector and
CW kit Op. Op. Op. Op.
USCW-AI900A/EL pencil transducers.

USUR-AI900A Hardware and software kit to display reference signals (ECG waveforms etc.).
Reference Signal kit Software licence to display reference signals (ECG waveforms etc.). Op. Op. Op. Op.
USUR-AI900A/EL
*Only for limited region

For cardiovascular examinations (for regions other than the USA) :


UJUR-AI900A Op. Op. Op. Op.
ECG, Respiration, ECG gating, Heart rate
Reference signal cable
For cardiovascular examinations (for the USA and Canada) :
UJUR-AI901A Op. Op. Op. Op.
ECG, Respiration, ECG gating, Heart rate

Reference signal sensor unit UJUR-AI902A PCG and Pulse sensor Op. Op. Op. Op.
USSE-AI900A,
Stress Echo kit Adds the cardiac stress examination function to the system. Op. Op. Op. Op.
USSE-AI900A/EL

USWT-AI900A,
2D Wall Motion Tracking kit Adds the cardiac wall motion analysis function to the system. Op. Op. Op. Op.
USWT-AI900A/EL

USSD-AI900A,
SI-DI kit This kit adds new color mapping based on Diastolic phase Strain in 2D WMT mode. Op. Op. Op. Op.
USSD-AI900A/EL

USWT-AI901A,
3D Wall Motion Tracking kit Adds 3D cardiac wall motion analysis function to the system. Op.*3 Op.*3 Op.*3 Op.
USWT-AI901A/EL

3D Wall Motion Tracking USWT-AI902A,


Adds right ventricular (RV) Analysis with 3D WMT. USWT-AI901A is needed. Op.*3 Op.*3 Op.*3 Op.
Advance kit USWT-AI902A/EL

2D Wall Motion Tracking USWT-AI904A, This kit enables cardiac wall motion analysis function for fetal heart using data from
Op. Op. Op. Op.
Fetal kit USWT-AI904A/EL a convex transducer. USWT-AI900A is required.

2D Wall Motion Tracking USWT-AI906A, Corresponds to analyze the entire four-chamber of LV, LA, RV and RA. USWT-AI900A
Op. Op. Op. Op.
Advanced kit USWT-AI906A/EL is required. (*9)

USQT-AI900A,
Quad Chamber Tracking kit Quad display for 3D Wall Motion Tracking results. Op.*3 Op.*3 Op.*3 Op.
USQT-AI900A/EL

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada. Op.: Option Std.: Standard
(*10) Only available in Europe with Cardiovascular model. NA: Not applicable

2
MPDUS0212EAC

Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health
USMA-AI900A, This software is used to analyze and evaluate the mitral valve in 3D images acquired
Mitral Valve Analysis kit Op.*4 Op.*4 Op.*4 Op.
USMA-AI900A/EL using the PEI-512VX.

This kit enables mitral valve analysis in 4D images acquired using the PEI-512VX
USMA-AI901A,
MVA 4D kit transducer. Op.*4 Op.*4 Op.*4 Op.
USMA-AI901/EL
*USMA-AI900A is required.

USVM-AI800A, This kit allows real-time 4D imaging using the PEI-512VX, PSI-50VX and
Volume Matrix kit Op. Op. Op. Std.
USVM-AI800A/EL PSI-30VX. It is included in the standard configuration of the TUS-AI900.

USVM-AI700A,
Volume Matrix 2 kit This kit enables real-time 3D imaging using PSI-40VX. Op. Op. Std. Std.
USVM-AI700A/EL

Luminance and Shadow USLM-AI901A,


Shadow Glass can be performed with Volume Matrix. Op.*3 Op.*3 Op.*3 Op.
Glass with Volume Matrix kit USLM-AI901A/EL

USAV-AI900A, This kit enables analysis of the Aortic Valve in 3D images acquired using the
AVA kit Op.*6 *10 NA NA Op.
USAV-AI900A/EL PEI-512VX.

Fetal Heart MPI USFH-AI600A, This kit enables Myocardial Performance Index (MPI). The MPI value can be
Op. Op. Op. Op.
Measurement kit USFH-AI600A /EL calculated from the time change curve in TDI.

USFP-AI900A, This kit enables the automatic generation of standard fetal heart views from a
Smart Fetal Heart kit Op.*7 Op.*7 Op.*7 Op.*7
USFP-AI900A/EL 4 chamber volume data set.

Pencil Connector unit UIPC-AI900A This unit is used to add connectors for pencil transducers. Op. Op. Op. Op.

TEE transducer hanger for the PET-609MA, PET-512MA, PET-512MC, PET-512MD,


M-TEE hanger kit UAEH-AI900A Op. Op. Op. Op.
PEI-512VX and PET-609MA.

TEE hanger kit UAEH-AI901A TEE hanger for the PET-508MA. Op. Op. Op. Op.

This kit consists of preset data suitable for CV examinations, a CV sticker, and a
CV kit UACV-AI900A Op. Op. Op. Op.
startup screen.

This kit is used to add the STC knob on the operating panel.
UIST-AI900A Op. Op. Op. Op.
Use in combination with UIUB-AI900 is not possible. For V5.1 or before.
STC kit
This kit is used to add the STC knob on the operating panel.
UIST-AI901A Op. Op. Op. Op.
Use in combination with UIUB-AI900 is not possible. For V6.0 or later.

The ultrasound scanning condition export function exports the scan conditions
Ultrasound scanning
USVL-AI900A, (currently selected image mode etc.) of the diagnostic ultrasound system to an
condition export function Op.*4 Op.*4 Op.*4 Op.
USVL-AI900A/EL external device.
Kit Applicable transducer: PET-512VX. (*9)

USHI-AI900A,
CHI kit Adds the Contrast Imaging function to the system. Op. Op. Op. Op.
USHI-AI900A/EL

USCQ-AI900A, Adds the Time Curve Analysis (TCA) function to the system. The USHI-AI900A is
CHI-Q kit Op. Op. Op. Op.
USCQ-AI900A/EL required.

USCQ-AI901A, Function for calculating characteristic value parameters by Fitting carve. The USCQ-
Fitting Curve kit Op. Op. Op. Op.
USCQ-AI901A/EL AI900A is required.

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada.
(*10) Only available in Europe with Cardiovascular model. Op.: Option Std.: Standard
NA: Not applicable

3
Prism Edition

Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health
USQC-AI800A,
Quad view for CHI kit This kit allows display of CHI in four-frame display. Op. Op. Std. Std.
USQC-AI800A/EL

USHI-AI901A,
High frame rate CHI kit This kit enables Contrast Harmonic Imaging with high frame rate. Op. Op. Op. Op.
USHI-AI901A/EL

This kit enables the visualization and analysis of the Direction/Velocity of bubbles
USVF-AI900A,
Contrast Vector Imaging kit by tracking individual contrast bubbles and displays such parameters with different Op. Op. Op. Op.
USVF-AI900A/EL
colors.

USMV-AI900A, This unit is required for using the 4D transducer or the motor-driven TEE transducer. Pre-
4D kit Op. Op. Op.
USMV-AI900A/EL Pre-installed in WHC model. installed

Image processing technology that makes 3D/4D images of fetuses and anatomical
USLM-AI900A, Pre-
Luminance kit structures appear more realistic. The USMV-AI900A or USVM-AI800A or Smart Sensor Op. Op. Op.
USLM-AI900A/EL installed
3D kit is needed. Pre-installed in WHC model.

This kit allows 3D display for displaying the internal walls of hollow organs and
USFT-AI900A,
Fly Thru. kit structures from endoluminal viewpoints as viewed using an endoscope. Op. Op. Op. Op.
USFT-AI900A/EL
USMV-AI900A or USVM-AI800A or Smart Sensor 3D kit is needed.

Both superficial and deep structures in a specific region can be observed


USSG-AI900A,
Shadow Glass kit simultaneously by superimposing them. Simultaneous display with a color 4D Op. Op. Op. Op.
USSG-AI900A/EL
image showing internal blood flow (CDI and SMI) is also possible.

Used for calculation of the volume by extracting the contours for regions with
Auto Volume Measurement USOB-AI900A, lower brightness in the 3D Volume image acquired in 4D mode. Enables volume
Op. Op. Op. Op.
kit USOB-AI900A/EL measurement, eg, antral follicle count. USMV-AI900A is required.
USMV-AI900A or USVM-AI800A or Smart Sensor 3D kit is needed.

USVS-AI900A,
4D ADF/SMI kit This kit enables imaging in ADF and SMI modes using abdominal VX transducer. Op. Op. Op. Op.
USVS-AI900A/EL

USVC-AI900A, This kit enables imaging in CHI mode using abdominal VX transducers.
4D CHI kit Op. Op. Op. Op.
USVC-AI900A/EL USHI-AI900A is required.

USPF-AI900A, This kit enables output of volume data for Smart 3D, Mecha4D, Smart Sensor 3D,
3D printer format export kit Op. Op. Op. Op.
USPF-AI900A/EL and Volume Matrix 3D to 3D printers.

USEL-AI901A, This kit enables Elastography (with FLR measurement) with linear and convex
14 Elastography-FLR kit
USEL-AI901A/EL transducers. (*1)
Op. Op. Op. Op.

USEL-AI900A,
Elastography kit The kit enables Elastography without FLR measurement. (*2) Op. Op. Op. Op.
USEL-AI900A/EL

USSW-AI900A, This kit allows tissue stiffness to be visualized by generating images that show shear
14 Shear Wave kit
USSW-AI900A/EL wave propagation.
Op. Op. Op. Op.

Upper limit and range are expanded from 200 kPa to 700 kPa to provide measure-
USSW-AI901A,
Shear Wave Hard kit ments of stiffer targets with the PLI-1205BX. Op. Op. Op. Op.
USSW-AI901A/EL
USSW-900A is required.

USQS-AI800A,
Quad view for SWE kit This kit allows display of shear wave images in four-frame display. Op. Op. Std. Std.
USQS-AI800A/EL

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada.
(*10) Only available in Europe with Cardiovascular model.
Op.: Option Std.: Standard
NA: Not applicable

4
MPDUS0212EAC

Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health

USDM-AI900A, This kit enables visualization of dispersion between frequencies for propagation
Dispersion Map for SWE kit NA NA Op. Op.
USDM-AI900A/EL speed for Shear Wave.

USFN-AI900A, CT/MRI/US volume data is loaded, and a CT/MRI/US planar image and an ultrasound
Smart Fusion kit Op. Op. Op. Op.
USFN-AI900A/EL image at the same position are displayed together. The UIFR-AI900A is required.

This kit allows display of a guideline in the image by simulating the pathway of the
USSN-AI900A,
Smart Navigation kit needle and the position of the needle tip based on positional information acquired Op. Op. Op. Op.
USSN-AI900A/EL
using the magnetic sensor.

This kit is used to generate the magnetic field for acquiring positional information
for transducers and needles in Smart Fusion, Smart Navigation, Smart Sensor 3D
Magnetic Generator kit UIFR-AI900A Op. Op. Op. Op.
and Smart Body Mark modes. Sensor securing adopters and magnetic sensors are
provided (one of each for the PVT-375BT, PVT-375SC, PVI-475BT and the PVI-475BX).

This magnetic sensor is added for performing Smart Fusion, Smart Navigation, and
Sensor kit for Fusion unit UIFR-A501A Op. Op. Op. Op.
Smart Sensor 3D using multiple transducers. The UIFR-AI900A is required.

Used for the Smart Fusion function. Performs automatic position matching between
USFN-AI901A,
Auto Registration kit the ultrasound volume data acquired in a previous exam and the real-time 2D Op. Op. Op. Op.
USFN-AI901A/EL
ultrasound image.

610-1228 CIVCO omniTRAX™ Active Patient Tracker.


Auto Track CT kit former UIOT-AI900A Op. Op. Op. Op.
610-1066 CIVCO General Purpose Electromagnetic Sensor.

610-1306 CIVCO omniTRAX MR Active Patient Tracker.


Auto Track MR kit former UIOT-AI901A Op. Op. Op. Op.
610-1066 CIVCO General Purpose Electromagnetic Sensor.

This pole cart allows the magnetic field generator included in the system main unit
Fusion Pole Cart UZWT-A500A Op. Op. Op. Op.
to be positioned independently.

UAFS-001A For PVT-382BT / PVT-482BT / PVI-482BX. (*5) Op. Op. Op. Op.

UAFS-002A For PVT-350BTP. (*5) Op. Op. Op. Op.

UAFS-003A For PVT-781VT. (*5) Op. Op. Op. Op.

UAFS-004A For PLT-1005BT. (*5) Op. Op. Op. Op.

UAFS-005A For PVL-715RST. (*5) Op. Op. Op. Op.


Mounting kit for fusion
UAFS-006A For PVT-781VTE. (*5) Op. Op. Op. Op.
sensor
UAFS-007A For PVI-475BX / PVI-475BT. (*5) Op. Op. Op. Op.

UAFS-008A For PLI-1205BX / PLI-2004BX / PLI-705BX / PLI-3003BX / PVI-574BX / PVT-574BT. (*5) Op. Op. Op. Op.

UAFS-009A For PSI-30BX / PSI-30VX / PSI-40VX / PSI-50VX / PST-28BT / PST-65BT. (*5) Op. Op. Op. Op.

UAFS-010A For PLT-1202BT / PLI-2002BT. (*5) Op. Op. Op. Op.

UAFS-011A For PVI-450BXP. (*5) Op. Op. Op. Op.

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada.
(*10) Only available in Europe with Cardiovascular model.
Op.: Option Std.: Standard
NA: Not applicable

5
Prism Edition

Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health
610-1059 CIVCO VirtuTRAX™ Instrument Navigator.
Smart Navigation Sensor kit former UISN-A500A Op. Op. Op. Op.
610-1066 CIVCO General Purpose Electromagnetic Sensor.

This kit enables that the information in the DICOM data from the digital
USMB-AI900A,
Breast Scan Guide kit Mammography MLO/CC images to be used to create an overlay position on the Op. Op. Op. Op.
USMB-AI900A/EL
Ultrasound body mark in reference mode.

USSB-AI900A, It automatically traces and displays the anatomical position of transducer mark
Smart Body Mark kit Op. Op. Op. Op.
USSB-AI900A/EL based on the transducer position using magnetic sensor. UIFR-AI900A is required.

This function is used to display high-precision Smart 3D images by detecting the


USSS-AI900A,
Smart Sensor 3D kit position of the transducer based on positional information acquired using the Op. Op. Op. Op.
USSS-AI900A/EL
magnetic sensor.

USMP-AI900A,
MicroPure kit This kit enables MicroPure, which supports visualization of small structures. Op. Op. Op. Op.
USMP-AI900A/EL

USPV-AI900A, B/W images can be obtained with a wider field of view by moving the transducer in
Panoramic View kit Op. Op. Op. Op.
USPV-AI900A/EL the lateral direction.

Multi-Reflection Canceller USRC-AI900A, This function is used to visualize images with fewer artifacts by cancelling multiple
Op. Op. Op. Op.
kit USRC-AI900A/EL reflections from the body.

USLP-AI900A
Liver Package kit Combination kit of USSW-AI900A, USDM-AI900A, and USAT-AI900A. NA NA Op. Op.
USLP-AI900A/EL

USLD-AI900A,
Doppler Luminance kit This kit allows display of the pseudo color doppler in three dimensions. Op. Op. Op. Op.
USLD-AI900A/EL

USGI-AI900A,
General Imaging kit This kit allows usage of General Imaging. NA. Op. NA NA
USGI-AI900A/EL

USAT-AI900A, This kit enables visualization of ultrasound frequency-dependent attenuation


Attenuation Imaging kit Op. Op. Op. Op.
USAT-AI900A/EL coefficient within tissue.

USSL-AI900A,
Slice thickness control kit This kit enables the slice thickness of the cross-sectional image to be changed. Op. Op. Op. Op.
USSL-AI900A/EL

USZS-AI900A,
Measurement Z score kit This kit enables Z-score analysis for the measurement results. Op. Op. Op. Op.
USZS-AI900A/EL

This kit consists of preset data suitable for OB examinations, an OB sticker, and a
OB kit UAOB-AI900A Op. NA Op. Op.
startup screen.

Limb Volume Measurement USTM-AI900A, This kit enables the calculation of Estimated Fetal Weight (EFW) from a Fetal thigh
Op. Op. Op. Op.
kit USTM-AI900A/EL volume data set acquired by mechanical 4D transducer. USMV-AI900A is required.

UZRI-AI900A Rack for mounting a B/W printer (For UP-D898MD/P95D) Op. Op. Op. Op.

UZRI-AI901A Rack for mounting a B/W printer (For UP-D711/AC or P95DW-DC) Op. Op. Op. Op.

Mounting kit for peripheral UZRI-AI902A Mounting kit for Color printer/DVD recorder. Compatible with UIFR-AI900A. Op. Op. Op. Op.
unit
Rack for mounting a B/W printer (For UP-D711/AC or P95DW-DC)
UZRI-AI903A Op. Op. Op. Op.
Compatible with UIFR-AI900A.

UZRI-AI904A Mounting rack for B/W printer or Color printer or DVD recorder. Op. Op. Op. Op.

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada.
(*10) Only available in Europe with Cardiovascular model. Op.: Option Std.: Standard
NA: Not applicable

6
MPDUS0212EAC

Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health

28,1Foot switch UZFS-004A Switch used for freezing, printing, and some other operations by foot. Op. Op. Op. Op.

35,2,2Gel warmer UZGW-008A This unit warms the ultrasound gel to a suitable temperature. Op. Op. Op. Op.

Transducer cable hanger kit UZMK-AI900A Long hanger on which the transducer cable is hooked. Op. Op. Op. Op.

A basket to store transducer connectors is added to the side of the system main
Transducer Holder kit UZBK-AI900A Op. Op. Op. Op.
unit. (one basket is provided in the standard configuration.)

This kit used to establish connection to the DICOM network via wireless LAN.
UIWL-A500A Complied with the Radio Law of Japan and applicable laws and regulations of USA, Op. Op. Op. Op.
Canada, EU member states, Iceland, Norway, Liechtenstein, and Switzerland.
Wireless LAN kit
This kit enables connection to the DICOM network via wireless LAN. (For Singapore,
UIWL-AI900A Op. Op. Op. Op.
Malaysia, Saudi Arabia, Russia, Australia, and Turkey.)

EV/ER Transducer Holder kit UZPH-AI900A This kit is used to add a dedicated holder for endocavitary transducers. Op. Op. Op. Op.

This kit is used to add a hardware full keyboard for entering the patient ID and
Keyboard kit UIKB-AI900A Op. Op. Op. Op.
comments.

This kit adds a tablet terminal that communicates with the system main unit via
wireless LAN to allow viewing and easy operation of the examination screen.
2nd Console kit UITB-AI900A Complied with the Radio Law of Japan and applicable laws and regulations of USA, Op. Op. Op. Op.
Canada, EU member states, Iceland, Norway, Liechtenstein, and Switzerland. UIWL-
A500A is included.

OLED Monitor UIOM-001A 21.6-inch wide OLED Monitor to replace 23-inch LCD Monitor with LED back light. Op. Op. Op. Op.

Function for setting up the patient database in the USB HDD in order to perform
DataBase for External HDD USDB-AI900A,
examinations. Op. Op. Op. Op.
kit USDB-AI900A/EL
*UZHI-AI900A is required.

Mounting kit for External Box with lock for installing the external HDD. HDD itself is not included.
UZHI-AI900A Op. Op. Op. Op.
HDD *USDB-AI900A is required.

ECG Cable Hanger kit UZMK-AI902A Hook used to hang the ECG cables on the front of the operating panel. Op. Op. Op. Op.

Kit for adding a USB port to the operating panel.


Panel USB Port kit UIUB-AI900A Op. Op. Op. Op.
Note that this kit cannot be installed if the UIST-AI900A is installed.

Pointing device, dial on track ball allows easier Gain adjustment without reaching
UZPT-001A out for another buttons. Applicalbe with the system which was shipped as V5.0 or Op. Op. Op. Op.
V5.1. For white panel.
Palm Controller kit
Pointing device, dial on track ball allows easier Gain adjustment without reaching
UZPT-002A out for another buttons. Applicalbe with the system which was shipped as V6.0 or Op. Op. Op. Op.
later. For black panel.

A battery kit to provide approximately 30 miniutes of operation without being con-


Battery unit UEBT-AI900A Op. Op. Op. Op.
nected to a power outlet.

USHE-AI900A,
Online Help kit Kit for displaying the operation manual on the viewing monitor. Op. Op. Op. Op.
USHE-AI900A/EL

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada.
(*10) Only available in Europe with Cardiovascular model.
Op.: Option Std.: Standard
NA: Not applicable

7
Prism Edition

Main unit

Unit Model name Remarks i700


i700 Women's i800 i900
Health

USPA-AI900A, A sequence of operations is registered, and each operation is executed by single


Protocol Assistant kit Op. Op. Op. Op.
USPA-AI900A/EL switch operation. Not necessary when USSE-AI900A is installed.

A demonstrating movie by Dr Inigo Iriate, Professor of Ultrasound of the Spanish


Society of Rehabilitation & Physical Medicine which tells the practical scanning tips
MSK Protocol Movie kit USPA-AI901A Op. Op. Op. Op.
of the anatomy and scanning of the shoulder provides examiners’ skill develop-
ment. USPA-AI900A or USSE-AI900A is required.

USDL-AI900A, This kit enables a combined reportfor the following liver applications:
Multi Parametric Report kit Op. Op. Op. Op.
USDL-AI900A/EL Shear Wave Elastography, Dispersion Imaging and Attenuation Imaging.

This kit provides a system label, and a startup screen suitable for dedicated Woman’s
Women's Healthcare kit UAWH-AI900A Op. NA Op. Op.
Healthcare systems.

Security Management kit USSM-AI900A This kit provides McAfee® software for security management of the system. Op. Op. Op. Op.

USRA-AI900A,
RADS kit This kit enables the Reporting and Data System. Op. Op. Op. Op.
USRA-AI900A/EL

USIO-AI900A,
IOTA kit This kit enables International Ovarian Tumor Analysis. (*8) Op. Op. Op. Op.
USIO-AI900A/EL

USNA-AI900A, This kit enables large capacity RAW data management with network attached stor-
Network Storage kit Op. Op. Op. Op.
USNA-AI900A/EL age (NAS) which is commercially vailable. (NAS itself is not included)

USTR-AI900A,
Tricefy Access kit This kit enables to access the Tricefy which is a cloud service for clinical images. Op. Op. Op. Op.
USTR-AI900A/EL

USUH-AI700A,
Ultra High Freq kit This kit enables use of 22-MHz, 24-MHz, 33-MHz transducers. Op. Op. Std. Std.
USUH-AI700A/EL

Newly designed (heavier) trackball to improved response to user and therefore


UZTB-AI900A Op. Op. Op. Op.
workflow. V5.1 or before.
Track Ball kit
Newly designed (heavier) trackball to improved response to user and therefore
UZTB-AI901A Op. Op. Op. Op.
workflow. For V6.0 or later.

UZKF-AI900A
(French)

UZKG-AI900A
(German)

UZKI-AI900A
(Italian)

UZKS-AI900A
(Spanish) This kit is intended for changing the key tops of the full keyboard to support specific
Local Language Key-Top kit Op. Op. Op. Op.
UZKD-AI900A languages. UIKB-AI900A is required.
(Danish)

UZKN-AI900A
(Norwegian)

UZKW-AI900A
(Scandinavian)

UZKR-AI900A
(Russian)

(*1) Not available in the USA.


(*2) Only available in the USA.
(*3) USVM-AI800A is required to use PSI-30VX, PSI-50VX and PEI-512VX on i800 and i700. (USVM-AI700A is required to use PSI-40VX on i700.)
(*4) USVM-AI800A is required to use PEI-512VX.
(*5) Magnetic Generator kit UIFR-AI900A is required separately.
(*6) USVM-AI800A is required.
(*7) USVM-AI800A or USMV-AI900A is required.
(*8) Only available in Europe.
(*9) Not available in the USA and Canada.
(*10) Only available in Europe with Cardiovascular model.
Op.: Option Std.: Standard
NA: Not applicable

8
MPDUS0212EAC

BLOCK CHART SYSTEMS


Main unit
TUS-AI900, TUS-AI800, TUS-AI700

Reference Signal kit


USUR-AI900A

Reference signal cable


UJUR-AI900A, UJUR-AI901A

Stress Echo kit


USSE-AI900A

Reference signal sensor unit


UJUR-AI902A

2D Wall Motion Tracking kit


USWT-AI900A

2D Wall Motion Tracking Advanced kit


USWT-AI906A

2D Wall Motion Tracking kit


USWT-AI900A

2D Wall Motion Tracking Fetal kit


USWT-AI904A

CW kit
USCW-AI900A

Pencil Connector unit


UIPC-AI900A

CV kit
UACV-AI900A

STC kit Panel USB Port kit


UIST-AI900A or UIST-AI901A UIUB-AI900A

Ultrasound scanning condition


export function kit
USVL-AI900A

ECG Cable Hanger kit


UZMK-AI902A

TEE Hanger
UAEH-AI900A, UAEH-AI901A

Foot Switch
UZFS-004A

A
9
Prism Edition

Volume Matrix Transducers Volume Matrix Transducers


for Cardiac for General
PSI-30VX, PSI-40VX (Cardiac Exam), Note:・USVM-AI800A is required to use PSI-30VX, PSI-40VX
PSI-50VX and PEI-512VX on i800 and i700.
PSI-50VX,PEI-512VX (USVM-AI700A is required to use PSI-40VX on i700.) Note: In case of i700, USVM-AI700A is required.
・Some options are not available depending on the transducer.

Smart Fetal Heart Kit


USFP-AI900A Fly Thru kit
*Not available in the USA and Canada.
Note: In case of i800 and i700, USVM-AI800A, is required. USFT-AI900A

Reference Signal kit


USUR-AI900A

Luminance & Shadow Glass


Reference Signal cable
with Volume Matrix kit
UJUR-AI900A
USLM-AI901A
UJUR-AI901A

3D Wall Motion Tracking kit


USWT-AI901A
4D CHI kit
USVC-AI900A Note: USHI-AI900A is required.
3D Wall Motion Tracking
Advance kit
USWT-AI902A

4D ADF / SMI kit


Quad chamber Tracking kit USVS-AI900A
USQT-AI900A

Auto Volume Measurement


Mitral Valve Analysis kit
USOB-AI900A
USMA-AI900A
Note: In case of i800 and i700, USVM-AI800A, is required.

MVA 4D kit
USMA-AI901A 3D printer format export kit
USPF-AI900A
Note: In case of i800 and i700, USVM-AI800A, is required.

AVA kit
USAV-AI900A
Shadow Glass kit
USSG-AI900A

Luminance & Shadow Glass


with Volume Matrix kit
USLM-AI901A
Note: In case of i800 and i700, USVM-AI800A, is required.

4D CHI kit
USVC-AI900A Note: USHI-AI900A is required.

4D ADF / SMI kit


USVS-AI900A

10
MPDUS0212EAC

B C

CHI kit MicroPure kit


USHI-AI900A USMP-AI900A

CHI-Q kit Panoramic View kit


USCQ-AI900A USPV-AI900A
Fitting Curve kit
Multi-reflection
USCQ-AI901A Canceller kit
USRC-AI900A
Quad View for CHI kit
USQC-AI800A *Standard on i900 and i800.
Fetal Heart MPI
Measurement kit
High frame rate CHI kit
USFH-AI600A
USHI-AI901A

Contrast Vector Imaging kit Liver Package


USVF-AI900A USLP-AI900A

4D kit Doppler Luminance kit


USMV-AI900A * Pre-installed in WHC model USLD-AI900A
Luminance kit
USLM-AI900A * Pre-installed in WHC model Attenuation Imaging kit
*In case of USLP-AI900A is installed,
USAT-AI900A this kit is not necessary.
Shadow Glass kit
USSG-AI900A
Slice thickness control kit
Fly Thru. kit USSL-AI900A
USFT-AI900A

Auto Volume Measurement Z score kit


Measurement kit USZS-AI900A
USOB-AI900A

Limb Volume OB kit


Measurement kit
UAOB-AI900A
USTM-AI900A

3D printer format export kit Women’s Healthcare kit


USPF-AI900A UAWH-AI900A

Smart Fetal Heart kit


USFP-AI900A Multi Parametric Report kit
USDL-AI900A
Elastography-FLR kit Elastography kit
USEL-AI901A USEL-AI900A Ultra High Frequency
USUH-AI700A *Standard on i900 and i800.
Shear wave kit
*In case of USLP-AI900A is installed,
USSW-AI900A this kit is not necessary.
Track Ball kit
Shear wave Hard kit
UZTB-AI900A or UZTB-AI901A
USSW-AI901A

Quad view for SWE kit Mounting kit Mounting kit Mounting kit Mounting kit
USQS-AI800A *Standard on i900 and i800. for a B/W printer for a B/W printer for Peripherals for Peripherals
(except UP-D711MD, (only for UP-D711 (for video recorder, (for B/W recorder,
*In case of USLP-AI900A is
P95D-DC) MD/AC, P95D-DC) color printer etc.) color printer etc.)
Dispersion Map for SWE kit installed, this kit is not UZRI-AI900A UZRI-AI901A, UZRI-AI903A UZRI-AI902A UZRI-AI904A
USDM-AI900A necessary.
*Not available on i700.

C D

11
Prism Edition

Wireless LAN kit Wireless LAN kit


UIWL-A500A UIWL-AI900A

2nd Console kit


UITB-AI900A

OLED Monitor
UIOM-001A

Gel warmer
UZGW-008A

Transducer cable hanger kit


UZMK-AI900A

EV/ER Transducer Holder kit


UZPH-AI900A

Transducer Holder kit


UZBK-AI900A

Keyboard kit
UIKB-AI900A

Protocol Assistant kit


USPA-AI900A

MSK Protocol Movie kit


USPA-AI901A

DataBase for External HDD kit


USDB-AI900A

Mounting kit for External HDD kit


UZHI-AI900A

Online Help kit


USHE-AI900A

Battery unit
UEBT-AI900A

Security management kit


USSM-AI900A

Palm Controller kit


UZPT-001A or UZPT-002A

12
MPDUS0212EAC

Breast Scan Guide kit


USMB-AI900A

RADS kit
USRA-AI900A

IOTA kit
USIO-AI900A
*Only available in Europe

Magnetic Generator kit


UIFR-AI900A

Fusion Pole Cart


UZWT-A500A

Mounting kit for fusion sensor


UAFS-001A, UAFS-002A, UAFS-003A, UAFS-004A, UAFS-005A, UAFS-006A
UAFS-007A, UAFS-008A, UAFS-009A, UAFS-010A, UAFS-011A

Sensor kit for Fusion unit


UIFR-A501A

Smart Body Mark kit


USSB-AI900A

Smart Fusion kit Smart Sensor 3D kit


Note: USFN-AI900A and USSS-AI900A
USFN-AI900A can be installed simultaneously. USSS-AI900A

Auto Registration kit Luminance kit


USFN-AI901A USLM-AI900A

omniTRAX Shadow Glass kit


610-1228 USSG-AI900A

General Purpose
Electromagnetic Sensor Fly Thru. kit
610-1066 USFT-AI900A

omniTRAX MR Auto Volume Measurement


610-1306 USOB-AI900A

General Purpose
Electromagnetic Sensor 3D printer format export kit
610-1066 USPF-AI900A

Smart Navigation kit


USSN-AI900A

Virtu TRAX
610-1059

General Purpose
Electromagnetic Sensor
610-1066

Network Storage kit


USNA-AI900A

Tricefy Access kit


USTR-AI900A

13
Prism Edition

TRANSDUCER OPTIONS/OPERATION MODES 26,2


Displayed range
Freq. Precision Slice
Model name Label of frequency 2D ApliPure Thickness MicroPure *1 BEAM M CDI Power
(MHz) Imaging
(MHz)
PSI-30BX i6SX1 3.0 1.5~6.0      
PSI-30VX i6SVX1 3.0 1.8~5.2     
PSI-40VX i6SVX2 4.0 1.8~6.0     
PSI-50VX i7SVX2 5.0 2.2~6.0     
PSI-70BT i10S4 7.0 3.5~9.0     
PST-25BT 5S1 2.5 1.7~4.7     
PST-28BT 6S1 3.0 1.5~6.0     
PST-30BT 5S2 3.0 1.7~5.2     
PST-50BT 6S3 5.0 3.0~8.2     
PST-65BT 12S4 7.0 3.5~12.0     
PVI-482BX i8MCX1 4.0 1.8~6.0       
PVI-475BT i8C1 4.0 1.8~6.4      
PVI-475BX i8CX1 4.0 1.8~6.4       
PVI-450BXP i8CXP1 4.0 1.8~6.2       
PVI-574BX i10CX1 5.0 2.0~9.5       
PVT-350BTP 6CP1 3.5 2.0~4.5      
PVT-375BT 6C1 3.5 1.5~6.0      
PVT-375SC 6Cs1 3.5 1.5~6.0      
PVT-382BT 6MC1 3.5 2.0~5.0      
PVT-482BT 8MC1 4.0 1.8~6.0      
PVT-574BT 10C1 5.0 2.0~9.5      
PVT-674BT 10C3 6.0 3.5~9.7      
PVT-675MVL 9CV2 6.0 2.5~7.0      
PVT-675MVS 9CV2 6.0 2.5~7.5      
PVT-681MVL 11CV3 6.0 3.6~11.0      
PVT-712BT 11MC4 7.0 4.3~11.0      
PVT-745BTF 11CI4 7.0 3.0~10.0      
PVT-745BTH 11CI4 7.0 3.0~10.0      
PVT-745BTV 11CI4 7.0 3.2~10.0      
PVT-770RT 10C5 7.0 4.7~10.0      
PVT-781VT 11C3 7.0 3.6~11.0      
PVT-781VTE 11C3 7.0 3.6~11.0      
Convex 7.5 4.5~9.0      
PVL-715RST 11CL4
Linear 7.5 4.5~9.0      
PLI-705BX i11LX3 7.0 3.5~11.5        
PLI-605BX i9LX2 6.0 2.8 - 9.0        
PLI-1205BX i18LX5 12.0 4.0~18.3         
PLI-2002BT i22LH8 20.0 8.8~22.0      
PLI-2004BX i24LX8 20.0 8.8~24.0        
PLI-3003BX i33LX9 30.0 10.0~33.0      
PLT-308BTP 6LP3 3.75 2.0~5.5      
PLT-704SBT 11L4 7.5 4.0~10.5       
PLT-705BT 11L3 7.0 3.0~8.5       
PLT-705BTF 11LI4 7.0 3.8~8.4      
PLT-705BTH 11LI4 7.0 3.8~8.4      
PLT-1005BT 14L5 10.0 3.8~14.0        
PLT-1202BT 17LH7 12.0 4.5~17.0      
PLT-1204BT 18L7 12.0 4.5~18.1        
PEI-512VX i6SVX2 5.0 1.8~6.6    
PET-508MA 7S3 5.0 2.5~7.0    
PET-609MA 8S3 6.0 3.6~8.0    
PET-512MA 8S2 5.0 3.0~6.5    
PET-512MC *5 8SM2 5.0 3.0~6.5    
PET-512MD *5 8SM2 5.0 3.0~8.5    
PET-805LA 12LI4 8.0 3.5~9.0      
PC-20M P2 2.0 2.0
PC-50M P5 5.0 5.0

*1: Optional software is required. *7: Optional software USVM-AI700A is required.


*2: Depends on the preset. *8: Optional software USUH-AI700A is required.
*3: Not available in the USA. *9: Optional unit UIPC-AI900A is required.
*4: Not available in the USA and Canada. *10: Optional software USCW-AI900A is required.
*5: Optional software USMV-AI900A is required. *11: Optional software USWT-AI904A is required.
*6: Optional software USVM-AI800A is required. *12: Using Single Crystal technology.

14
MPDUS0212EAC

TRANSDUCER OPTIONS/OPERATION MODES 26,3


Elasto- SMI/ Shear CHI*1 Volume
Model name TDI ATI*1 PWD CWD*10 4D*1
graphy*1 ADF wave*1 2D SMI ADF MFI VRI color*1
PSI-30BX      
PSI-30VX        
PSI-40VX         
PSI-50VX      
PSI-70BT      
PST-25BT    
PST-28BT      
PST-30BT      
PST-50BT    
PST-65BT    
PVI-482BX      
PVI-475BT           
PVI-475BX           
PVI-450BXP      
PVI-574BX        
PVT-350BTP      
PVT-375BT          
PVT-375SC          
PVT-382BT      
PVT-482BT      
PVT-574BT        
PVT-674BT      
PVT-675MVL    
PVT-675MVS    
PVT-681MVL        
PVT-712BT  
PVT-745BTF    
PVT-745BTH    
PVT-745BTV  
PVT-770RT  
PVT-781VT       
PVT-781VTE       
Convex     
PVL-715RST
Linear  
PLI-705BX      
PLI-605BX      
PLI-1205BX         
PLI-2002BT    *3 *3 *3
PLI-2004BX    *3 *3 *3
PLI-3003BX  
PLT-308BTP  
PLT-704SBT     
PLT-705BT     
PLT-705BTF   *3 *3
PLT-705BTH   *3 *3
PLT-1005BT         
PLT-1202BT    *3 *3
PLT-1204BT      
PEI-512VX     
PET-508MA   
PET-609MA   
PET-512MA   
PET-512MC *5   
PET-512MD *5   
PET-805LA     *4 
PC-20M 
PC-50M 

*1: Optional software is required. *7: Optional software USVM-AI700A is required.


*2: Depends on the preset. *8: Optional software USUH-AI700A is required.
*3: Not available in the USA. *9: Optional unit UIPC-AI900A is required.
*4: Not available in the USA and Canada. *10: Optional software USCW-AI900A is required.
*5: Optional software USMV-AI900A is required. *11: Optional software USWT-AI904A is required.
*6: Optional software USVM-AI800A is required. *12: Using Single Crystal technology.

15
Prism Edition

TRANSDUCER OPTIONS/OPERATION MODES


STIC Smart Sensor Smart 2D*1 3D Main unit *1 Applicable
Model name STIC*5 Fusion*1 CVI Remarks
Color*5 3D 3D*1 Navigation*1 WMT WMT*1 i700 i800 i900 Version
PSI-30BX       *12
PSI-30VX    *6 *6  *12
PSI-40VX    *7   V2.0 and later *12
PSI-50VX    *6 *6  V2.0 and later *12
PSI-70BT    
PST-25BT    
PST-28BT       V3.0 and later *12
PST-30BT    
PST-50BT    
PST-65BT     V4.0 and later
PVI-482BX        V4.0 and later
PVI-475BT     *11    *12
PVI-475BX     *11     *12
PVI-450BXP        V4.0 and later *4
PVI-574BX     *11    V3.0 and later *12
PVT-350BTP        *4
PVT-375BT        
PVT-375SC         *12
PVT-382BT       
PVT-482BT        V2.0 and later *12
PVT-574BT     *11    V3.0 and later *12
PVT-674BT  *11   
PVT-675MVL *2 *2 *11    *5
PVT-675MVS *2 *2 *11    V2.0 and later *5
PVT-681MVL    *5
PVT-712BT    
PVT-745BTF    
PVT-745BTH    
PVT-745BTV    
PVT-770RT    V3.0 and later
PVT-781VT       
PVT-781VTE       
Convex      
PVL-715RST
Linear      
PLI-705BX        V2.0 and later
PLI-605BX    V6.0 and later
PLI-1205BX        
PLI-2002BT    *8   V2.0 and later *8
PLI-2004BX     *8   *8
PLI-3003BX    *8   V3.1 and later *8
PLT-308BTP     *4
PLT-704SBT    
PLT-705BT    
PLT-705BTF     V1.8 and later
PLT-705BTH     V1.8 and later
PLT-1005BT        
PLT-1202BT       V2.0 and later
PLT-1204BT    
PEI-512VX *4 *6 *6  *12
PET-508MA *4   
PET-609MA     V4.0 and later *4
PET-512MA     V1.8 and later *4
PET-512MC *4    V1.8 and later *5
PET-512MD *4    *5
PET-805LA   
PC-20M    *9, *10
PC-50M    *9, *10

*1: Optional software is required. *7: Optional software USVM-AI700A is required.


*2: Depends on the preset. *8: Optional software USUH-AI700A is required.
*3: Not available in the USA. *9: Optional unit UIPC-AI900A is required.
*4: Not available in the USA and Canada. *10: Optional software USCW-AI900A is required.
*5: Optional software USMV-AI900A is required. *11: Optional software USWT-AI904A is required.
*6: Optional software USVM-AI800A is required. *12: Using Single Crystal technology.

16
MPDUS0212EAC

SPECIFICATIONS • Line density


– The line density differs depending on the transducer
System
used.
• Scan methods: Linear scan (some transducers
– The line density can be changed.
can perform oblique scanning)
• Ultrasound Frame Rate
Sector scan
3 – The ultrasound frame rate can be adjusted by using the
Convex scan
following in combination.
Trapezoid scan
· Line density
Curved vector scan
· Parallel signal processing
• Monitor:
• Scan Angle and Scan Width
– High-definition 23-inch Wide LCD monitor with LED 28,6
– Adjustment of the field width (scan width, scan angle) is
backlight 28,6,2 possible.
· Resolution: 1920 × 1080 (Full HD)
– Adjustment of beam steering (scanning position) is
· Viewing angle: 178 degrees
possible.
· Contrast ratio: typ. 1000: 1
– Adjustment of linear beam steering is possible.
· Response time (ms): typ. 14
• PAN/EXPAND
· Luminance (cd/m2): typ. 300
Real-time PAN/EXPAND
· Conformance Standard: DICOM Part 14
– Scale enlargement/reduction using the encoder is
– 4K 21.6-inch Wide OLED monitor possible. 28,5,1
· Resolution: 3840 × 2160 – Movement to the desired section using the trackball is
· Viewing angle: 178 degrees *CR≧10 possible.
· Contrast ratio: typ. 1000000: 1 – The transmission focus is optimized in steps above.
· Response time (μs): typ. 40 (30 + 10) – The specified range of an image can be magnified.
*Black-> White-> Black (Spot Zoom) 19,1
· Luminance (cd/m2): typ. 200 (7500 K) • Transmission Focus
typ. 145 (13000 K) Transmission conditions: A maximum of 8 steps
· Conformance Standard: DICOM Part 14 • Transmission Frequency
• Presets Multi frequency: 3 frequencies can be selected
– System preset: 1 type from 13 types.
• GAIN
Compatible Peripheral Devices – The display brightness for 2D can be changed.
• Black-and-white digital printer (Also available when the image is frozen)
– UP-D711MD: AC (100 V to 240 V, SONY) – The display brightness for 2D and M can be changed
– UP-D898MD: AC (100 V to 240 V, SONY) simultaneously.
35,3 – P95DW or P95DE: AC (100 V to 240 V, MITSUBISHI) • STC
9,3
* Not available in CE marking region.
– Software STC 28,7,1
• Color digital printer · Depth direction from the body surface: 8-step slide
– UP-D25MD: AC (100 V to 240 V, SONY) controls (common for 2D and M)
– CP30DW: AC (120 V, 220V to 240 V, MITSUBISHI) · Lateral direction in the image: 6-step slide controls
* Not available in CE marking region.
(common for 2D and M)
• DVD video recorder
– Hardware STC (UIST-AI900A is required.)
– HVO-550MD/FHD: AC (100 V to 240 V, NTSC/PAL, SONY)
8-step slide controls (common for 2D and M) 17
• USB flash drive
• Acoustic Output
• External HDD
Adjustment is possible to 100%.
• Barcode reader
• Adjusting the 2D Image Quality
– Dynamic range (also available when the image is frozen)
2D mode (B mode) 9,1 – Time-smoothing (persistence)
• Viewing Depth
– Gamma (also available when the image is frozen)
The viewing depth depends on the transducer used.
– Auto gain control
– Convex
– Frame rate
· Maximum depth: 50 cm 6
– ApliPure
– Linear
– Precision
· Maximum depth: 14 cm – Reverberation (USRC-AI900A is required.)
– Sector
· Maximum depth: 28 cm

17
Prism Edition

• 2D Map M mode 9,2


– The grayscale pattern can be changed and virtual color • M Transmission Frequency
setting for the 2D image is possible. 18 Multi frequency: 5 types (at maximum)
– Settings can also be changed when the image is • M Sweep Speed
frozen. The Sweep Speed can be changed in M mode.
• 2D Quick Scan • M Gain
The gain and STC can be adjusted automatically. M gain can be corrected for 2D gain.
• THI (Tissue Harmonic Imaging) 11 • M Image Processing Parameters
THI signal processing methods – M dynamic range (can be changed even after the image
– Pulse subtraction method has been frozen).
– Filtering method – M auto gain control
– Differential method – M gamma (can be changed even after the image has
• Display Orientation 19,2 19,3 been frozen).
– Top/bottom reversal is possible. • M Map
– Left/right reversal is possible. M image virtual color setting is possible. The setting can be
• Image Size changed even after the image has been frozen.
The displayed image size can be switched between • THI (Tissue Harmonic Imaging)
small and large. 2D mode and THI mode are linked, and M images can be
• ApliPure displayed in THI mode.
– ApliPure – Pulse subtraction method
This function reduces ultrasound wave interference with- – Filtering method
in tissues, which appear as speckle patterns or speckle 12 – Differential method
noise on 2D images. • M Mark
– ApliPure+ – The M cursor can be displayed on 2D or C images.
This function can display the boundaries between – The M cursor displayed position can be adjusted.
tissues more clearly and reduce speckle noise and acous-
• Flex-M
tic shadows.
Any desired plane can be set on the 2D-mode image and
• MicroPure (USMP-AI900A is required.)
the M-mode image for the set plane can be reconstructed.
– Small structures can be extracted by performing
filtering for 2D-mode images.
Doppler (Spectrum Doppler) 9,5
– Visualization of very small calcifications and other
• Doppler Mode
extremely small lesions can be improved.
– PWD (pulsed-wave Doppler)
• Precision Imaging
– HPRF PWD (can be switched to HPRF mode) 9,8,5
– Precision+
– CWD (continuous-wave Doppler) 9,8,6
· Structures in 2D-mode images can be displayed more
(USCW-AI900A is required.)
clearly and the background can be displayed more
– Pencil CWD (pencil-type transducer)
smoothly.
(UIPC-AI900A and USCW-AI900A are required.)
· Saturation in high-intensity regions of tissue structures
is reduced, allowing the tissue structures to be dis- • Doppler Pulse Repetition Frequency (PRF)
played in a more natural manner. – PWD: 0.3 kHz to 52.1 kHz
• TSO (Tissue Specific Optimization) – CWD: 1.4 kHz to 52.1 kHz
– Reception focus compensation can be performed. • Doppler Scan
– Automatic reception focus compensation can be – 2D/D simultaneous scan
performed. (Auto TSO) – D only scan
• BEAM (Biopsy Enhancement Auto Mode) • Doppler Sampling Volume
– Display of the needle can be enhanced in the image. The Doppler range gate width can be changed. (Minimum
– The enhancement level can be adjusted. 0.3 mm)
• Slice Thickness Control (USSL-AI900A is required.) • Doppler Sampling Shift
The ultrasound beam slice width can be adjusted. 0 cm to the maximum depth
• Doppler Luminance (USLD-AI900A is required.) • Doppler Cursor Mode
Doppler Luminance is a function for displaying 3D images Operation for the 2D live image is possible with the
created from 2D color images acquired in Color modes Doppler sampling volume displayed in it.
(CDI/Power/ADF/SMI). • Doppler Filter
The Doppler filter cutoff can be changed.
• Doppler Gain
The display brightness for Doppler can be changed.
18
MPDUS0212EAC

• Doppler Quick Scan – Power Angio mode


The Doppler scale and baseline shift can be adjusted auto- – TDI mode
matically. – TwinView
• Doppler Frequency Analysis and Image Processing Simultaneous dual-screen display with 2D mode is avail-
– Method: FFT able.
– No. of data items: 255 (maximum) – SMI (Superb Micro vascular Imaging) mode
• Indication of Doppler Spectrum Direction · Clutter suppressed
Reverse display of the velocity spectrum is possible. · Blood flow enhanced
• Doppler Baseline Shift (Zero Shift) – ADF (Dynamic Flow) mode 10
– The velocity baseline of Doppler images can be shifted. · Direction display
9,8,2
– The baseline shift setting can also be adjusted when • C Map
images that were frozen are displayed. 9,8,3 – C map can be selected for each color Doppler mode.
• Doppler Audio – Changes can also be made when the image is frozen.
Stereo output (blood flow toward and away from the • C Scale (Switching the Velocity Range)
transducer) The velocity range can be changed.
• Doppler Map • C Time-Smoothing (Persistence)
The brightness conversion table and the virtual color for The result of temporal correlation processing between the
Doppler images can be set. previous image and current image can be displayed.
• Display of Doppler Scale • C Baseline (Zero Shift)
2 types (velocity, Doppler shift frequency) – The velocity baseline of color Doppler images can be
• Doppler Focus shifted.
Automatically follows the sample position. – The baseline shift setting can also be adjusted when
• Doppler Angle Mark images that were frozen or images in the image memory
This mark is displayed for measuring the angle between are displayed.
the direction of the velocity and the direction of the ultra- • Reverse C Display
sound beam. – Coloring is reversed.
• Doppler Oblique Scan (PWD Steering) – Changes can also be made when the image is frozen.
– Oblique scans are possible using a specific linear trans- • Black and White/Color Balance
ducer. – By comparing the color Doppler images and B/W imag-
– Auto Invert function es, color weighting to B/W can be set.
• Doppler Multifrequency 9,8,1 – Changes can also be made when the image is frozen.
The PWD transmission frequency can be changed. • C Gain
• Doppler Sweep Speed The display brightness of color Doppler images can be
The Sweep Speed can be changed in Doppler mode. changed.
• Doppler Display Dynamic Range • C Multifrequency
The display dynamic range of the Doppler image can be The transmission frequency for color Doppler image acqui-
changed. sition can be changed.
• Doppler Auto Trace (measurement performed after • C Line density
freezing the image) The color Doppler image line density can be changed.
Measurement of peak velocity and mean velocity is • C ROI (Region of Interest)
possible by automatic velocity tracing. Position, size, and steering adjustment is possible for color
The following Doppler waveform trace is possible. Doppler ROIs.
– Trace style: Waveform Peak, Mean, Peak+ • C Transmit Focus
Mean Automatically follows the color Doppler ROI position.
– Trace area specified: Forward, Reverse, Full, Auto • C Filter
– Measurement item: Max, Min, Mean, PI, RI, etc. Color Doppler low-cut filter can be changed.
• Variance Curve
Color Doppler 9,6 The display of the color variance component can be
Color Doppler Mode adjusted.
• Display mode • Color Quick Scan
– CDI mode The following operations are possible when a linear trans-
· Flow velocity ducer is used.
· Flow velocity/variance · The position of a color ROI and angle of color steering
· Power 9,8,4 are adjusted automatically.

19
Prism Edition

· When PWD sampling volume is displayed, the Doppler – Phonocardiogram (PCG) (UJUR-AI902A is required.)
gate position, Doppler steering angle, and Doppler · PCG microphone: Acceleration type
angle are adjusted automatically. · Filter: Switching is possible.
• Slice Thickness Control (USSL-AI900A is required.) – Pulse (UJUR-AI902A is required.)
The ultrasound beam slice thickness can be adjusted. Pulse transducer: Air conduction type
– Respiration
Color Doppler M mode (MDF Mode) Impedance method using the reference signal cable
• Display mode • Heart Rate
– MCDI mode The heart mark blinks in synchronization with the heart
· Velocity display beat detected by the ECG.
· Velocity/variance display The heart rate is displayed.
· Power display • Reference Signal Sweep Speed
– M-TDI mode This changes the reference signal sweep speed.
• M Color Doppler Map (CDI MAP)
Color Doppler map can be selected for each mode. Other Diagnostic Function
• M Color Doppler Velocity Range Selection (C Scale) • CHI (Contrast Harmonic Imaging) (USHI-AI900A is required.)
The velocity range can be selected. The second-harmonic wave signals from the microbubbles
• M Color Doppler Baseline (C Baseline) in the contrast medium can be effectively visualized.
– The zero-velocity line on the M Color Doppler image can – The following image modes can be selected.
be shifted. · PS (Pulse Subtraction) -Low, PS-Low2
– The baseline shift setting can also be adjusted when · VRI (Vascular Recognition Imaging)
images that were frozen are displayed or when the · Fundamental
image in the image memory is played back. · CHI ADF
• Color Reverse Display · SMI (Superb Micro Vascular Imaging)
– The colors can be reversed. – The following functions can be selected.
– Changes can also be made when the image is frozen. · 2D TwinView
• Black and White/Color Balance · Micro Flow Imaging (MFI)
– Color weighting for B/W images can be set by compar- · Image Stabilizer
ing the M Color Doppler images and B/W images. · MI Constant function
– Changes can also be made when the image is frozen. · Quad display (USQC-AI800A is required for i700.)
• Color Gain • Parametric MFI
The display brightness of the M Color Doppler image can – Temporal information can be displayed as a color map
be changed. superimposed on images acquired by 2D mode (without
• M Color Doppler Multi-Frequency CHI starting up), ADF/SMI mode, and CHI mode (contrast
Doppler transmission frequency can be selected in M image for the period from the start of contrast medium
Color Doppler image acquisition. injection to the time when the contrast medium reaches
• M Color Doppler Filter the target region).
M Color Doppler low-cut filter can be changed. – The following functions are available.
· Micro Flow Imaging (MFI)
Reference Signals · Image Stabilizer
(USUR-AI900A and UJUR-AI900A, or USUR-AI900A and UJUR- • CVI (Contrast Vector Imaging)
AI901A are required.) (USVF-AI900A is required.)
• Type – This function allows color mapping of the flow of ultra-
– Electrocardiogram (ECG) sound contrast medium (bubbles) within the tissues for
· Lead I is the standard connection. contrast images acquired in CHI mode.
· External input is possible. – Color mapping for the following items is available.
· DC IN · Arrival time: Speed display (mm/s)
The connected device must comply with IEC 60601-1. · Direction: Direction display (deg)
· Top/bottom inversion is possible. · Arrival Time: Arrival time from the start posi-
· Lead switching tion for analysis (sec)
· Pacemaker – Measurement function for velocity and direction
· INST

20
MPDUS0212EAC

• 4D Magic Cut
Three-dimensional image data (volume data) can be gen- 4D ADF/SMI (USVS-AI900A is required.)
erated and displayed by using image data acquired for 4D CHI (USVC-AI900A and USHI-AI900A are required.)
three-dimensional image reconstruction. 4D Biopsy
– Mechanical 4D (USMV-AI900A is required.) FlyThru (USFT-AI900A is required.)
· The following functions can be used. Luminance (USLM-AI901A is required.)
Volume Color Shadow Glass (USLM-AI901A is required.)
Multi View Omni View
Volume View Smart Fetal Heart (USFP-AI900A is required.)
VolPure STL export (USPF-AI900A is required.)
Magic Cut · The following measurements can be performed.
STIC/STIC Color MPR
4D CHI (USHI-AI900A is required.) Multi Auto Volume Measurement (USOB-AI900A is
4D Biopsy required.) [ Table 2 ]
Fly Thru (USFT-AI900A is required.) – Cardiac 4D
Luminance (USLM-AI900A is required.) USVM-AI800A is required to use PSI-30VX, PSI-50VX and
Shadow Glass (USSG-AI900A is required.) PEI-512VX on i800 and i700.
OmniView (USVM-AI700A is required to use PSI-40VX on i700.)
Auto flexible cut line · The following functions can be used.
STL export (USPF-AI900A is required.) Multi plane
· The following measurements can be performed. Volume (including ECG synchronous scan)
MPR Volume Color (including ECG synchronous scan)
Multi Auto Volume measurement (USOB-AI900A is Shadow Glass (USLM-AI901A is required.)
required.) [ Table 1 ] Luminance
– General 4D (USVM-AI700A is required for i700.) Smart Fetal Heart (USFP-AI900A is required.)
· The following functions can be used. STL export (USPF-AI900A is required.)
Volume Color · The following measurements can be performed.
Multi View MPR [ Table 3 ]
Volume View

[ Table 1 ]
Single 4D STIC Volume 4D Fly Shadow Max sweep
Transducer name 4D Live STIC Luminance*1
Sweep CHI*1 Color Color Biopsy Thru*1 Glass*1 range (deg)

PVT-675MVL   *2 *2     90


2 2
PVT-675MVS   * *     90

PVT-681MVL         150

[ Table 2 ]
4D Volume 4D Fly Shadow 4D Mitral Valve Aortic Valve
Transducer name 4D Live Luminance*1
CHI*1 Color Biopsy Thru*1 Glass*1 SMI*1 Analysis*1 Analysis

PSI-40VX        

[ Table 3 ]
4D Volume 4D Fly Shadow 4D Mitral Valve
Transducer name 4D Live Luminance*1
CHI*1 Color Biopsy Thru*1 Glass*1 SMI*1 Analysis*1

PSI-30VX      

PSI-50VX     

PEI-512VX     

*1: Optional software is required.


*2: Depends on the preset.

21
Prism Edition

• Stress Echo (USUR-AI900A and UJUR-AI900A, or USUR- · Multivolume display (Quad display)
AI900A and UJUR-AI901A are required.) · 3D body mark display (Quad display)
Exercise and pharmacological stress echo examinations · Auto Registration (USFN-AI901A is required.)
can be performed. · Auto Track (UIOT-AI900A or UIOT-AI901A is required.)
– Data acquisition mode – The following measurements can be performed.
This mode is intended for selecting and creating protocols. · Basic measurement
– Review mode · Cardiac measurement (for ultrasound live image)
This mode provides playback function/data output func- • Protocol Assistant (USPA-AI900A is required.)
tion/Wall Motion Scoring (WMS) function. A series of operations (a protocol) that has been created
• Panoramic View (USPV-AI900A is required.) 13 for the intended examination can be executed automatically.
– A continuous image can be acquired by moving the Protocols can be created and edited.
transducer horizontally on the body surface. • Shear wave (USSW-AI900A is required.)
– Measurement using Panoramic View can be performed. Images representing the speed of propagation of tissue
• Elastography (USEL-AI901A or USEL-AI900A is required.) displacement (shear wave speed) can be visualized (shear
– Tissue stiffness can be visualized based on the changes wave scan) by locally displacing tissues by transmitting a
in velocity resulting from physical compression and burst wave with high acoustic pressure.
decompression of the target region. – The following Shear wave display modes are available.
– FLR measurement can be performed to calculate the · Speed: shear wave speed display (m/s)
strain within the set ROI. (Not available in the USA.) · Elasticity: elasticity display (kPa)
• VI (Vascularity Index) · Propagation: propagation display
The number of pixels in the Power/ SMI image and within · Dispersion: Frequency dispersion display
the ROI, the area of the Power/ SMI image and of the ROI, (USDM-AI900A is required.)
and the ratio of the number of pixels in the Power/ SMI – Quad display is possible. (USQS-AI800A is required for
image to the number of pixels within the ROI can be dis- i700.)
played for an image acquired in Power/ SMI mode. – ECG Sync Acquisition function can be used.
Available on all linear transducers and all convex transduc- – Shear wave measurement can be performed.
ers. – ATI (Attenuation Imaging)
• Histogram (USAT-AI900A is required.)
The number of pixels, average gradation, standard devia- The ultrasound wave attenuation can be displayed in
tion, and brightness distribution inside the ROI in the color parametric and measured.
image acquired with 2D mode are displayed. • Smart Navigation (USSN-AI900A etc. are required.)
• Fusion (Smart Fusion) (USFN-AI900A etc. are required.) A needle navigation line can be superimposed on the
Synchronization of ultrasound scanning with CT/MRI ultrasound image based on the positional relationship
image display adjusted according to the examination posi- between the magnetic sensor attached to the transducer
tion determined using a magnetic sensor attached to the and the magnetic sensor attached to the puncture needle.
transducer can be performed. • Smart Sensor 3D (USSS-AI900A, UIFR-AI900A, and UIFR-
Prostate biopsy report is available. AI501A are required.)
– The following video modes can be selected. Generation of 3D images can be performed based on the
· 2D mode (B mode) positional information obtained using the magnetic sensor
· Color Doppler attached to the transducer.
· PWD (pulsed-wave Doppler) – The following functions can be used.
· CWD (continuous-wave Doppler) · Volume Color
(USCW-Al900A is required.) · Multi View
· CHI (Contrast Harmonic Imaging) · Volume View
· Elastography (USEL-AI901A or USEL-AI900A is required.) · Magic Cut
– The following image data can be referred to. · CHI (USHI-AI900A is required.)
· CT · Fly Thru (USFT-AI900A is required.)
· MR · Luminance (USLM-AI900A is required.)
· PET · Shadow Glass (USSG-AI900A is required.)
· 3D US (USSS-AI900A is required.) · Shear Wave (USSW-AI900A is required.)
– The following functions can be used. · OmniView
· Blend display · ECG Sync Construction
· Segment display · STL export (USPF-AI900A is required.)
· Multiplane display (Triple display)
22
MPDUS0212EAC

– The following measurements can be performed. Display-Related Features


· MPR • Display Method
· Multi Auto Volume Measurement – Images on the main unit: 60 Hz non-interlaced display
(USOB-AI900A is required.) – Images from external
• Smart 3D 15 playback devices: 60 Hz non-interlaced display
3D image can be generated from the 2D image and any • Monitor Display/ Character Display
input volume shape. – ID area
– The following functions can be used. · Patient ID
· Volume Color · Patient name
· Multi View · Hospital name
· Volume View · Date: Selected from among the for-
· Magic Cut mats shown below.
· Omni View YYYY/MM/DD
· CHI (USHI-AI900A is required.) MM/DD/YYYY
· Shear Wave (USSW-AI900A is required.) DD/MM/YYYY
· STL export (USPF-AI900A is required.) YYYY: Western calendar year
• Reference MM: Month
The ultrasound images of the current examination and the DD: Day
previously acquired image of the patient can be displayed · Time: Selected from among the for-
simultaneously. mats shown below.
– The following video modes can be selected. hh:mm:ss: AM (PM)
· 2D mode (B mode) hh:mm:ss: 24-hour representation
· Color Doppler hh: Hour
– The following image data can be referred to. mm: Minute
· US image (still image) ss: Second
· Raw data acquired using · VIDEO mark, VCR counter
TUS-AI900/ TUS-AI800/ TUS-AI700 · Age
· CT · Sex
· MR · Heart rate display (heart-shaped mark/heart rate)
· MG · Name of the Imaging Preset
· PET · Name of the operator
– The following function is available. · Gestational age
Breast scan guide (USMB-AI900A is required.) – Acoustic power display area
– The following measurement can be performed. · Acoustic power value (%)
Basic measurement · TI value
• Smart Area Indication (OB) – Auto data
The Smart Area Indication (OB) function is used in obstet- · Frame rate
rics to detect fetal measurement regions based on signals · Acoustic power index = MI indication
in images. · Transducer frequency
– The following measurements are available. · Depth
· BPD · Dynamic range
· HC 23,1 · GAIN
· AC · CDI filter
· FL · PRF
– The following transducer supports Smart Area Indication · Doppler filter
(OB). · Doppler angle
· PVI-475BX · Doppler gate size
• Smart Body Mark – Thumbnail area
(USSB-AI900A and UIFR-AI900A are required) · Image data acquired during the current examination is
Smart Body Mark is a function to display positional infor- displayed.
mation of the transducer on the screen using a magnetic · Information from a previous examination of the patient
sensor attached to the transducer. currently being examined is displayed.
– Information message display area
An operation guide and other messages are displayed.
23
Prism Edition
28,5,2
– Status area Supported Screen Input by software Input by hardware
The following system statuses can be displayed. language display keyboard keyboard*
· Battery capacity
· DVD/CD write status English   
· Network use status  
English (UK) 
· PACS use status (same as"English") (same as"English")
· Used space on HDD
German   
· Saving dynamic/ still image
· DICOM printer status/ peripheral device status French   
· USB flash drive status display Italian   
– Multifunction display area
Assignment statuses for trackball and surrounding Spanish   
switches and dials Danish   
• Annotation
Dutch   
– Manual input using the keyboard is possible.
– Auto annotation (previously specified text) is possible. Norwegian   
• Pictograms Swedish   
Body icons and transducer mark
• Biopsy Guide Mark Finnish   
Biopsy guide mark display is possible. Portuguese   
• Touch Panel (TCS: Touch Command Screen)
28,7 Icelandic   
– 12.1-inch LCD monitor: SXGA (1280 × 800)
– The touch panel tilt angle can be changed by 15°. Russian   
• Language
Japanese   
The following languages are supported for the display of
some screens and keyboard entry. Chinese   
: Applicable : Not applicable
*: UIKB-AI900A is required.

Measurement Functions
Basic Measurement Functions
• 2D-mode measurements
– Distance
· Distance
· Trace Length
· Mean-IMT 23,3
– Area
– Angle
· Angle
· Joint
– Volume
– Stenosis ratio
· %Stenosis (Distance)
· %Stenosis (Area)
• 4D-mode measurements (USMV-AI900A is required.)
– Distance
· Distance
· Trace Length
· Mean-IMT
– Area
– Angle
· Angle
· Joint

24
MPDUS0212EAC

– Volume · Fetal heart MPI measurement (USFH-AI600A is


· Volume required.)
· Auto Volume Measurement (USOB-AI900A is required.) · Limb volume measurement (USTM-AI900A and USMV-
– Stenosis ratio AI900A are required.)
· %Stenosis (Distance) · Anatomy
· %Stenosis (Area) · User chart registration
– Shear Wave measurement · Z score analysis (USZS-AI900A is required.)
• M-mode measurements – Vascular measurement
– Slope · CCA (Common Carotid Artery) measurement
– Distance · ECA (External Carotid Artery) measurement
– Time · ICA (Internal Carotid Artery) measurement
– Heart rate · Vert A (Vertebral Artery) measurement
• PW/CW Doppler measurements · Subclav A (Subclavian Artery) measurement
– Velocity · Auto-IMT measurement
– Acceleration · IMT-C10 measurement
– Time – User-registered measurements registration function. 24,1
– Heart rate 23,3 · Measurement items and calculation items based on 24,2
– PI the measured values
– RI · Layout setting on the Worksheet screen
– S/D · Switch layout setting of the touch panel
– Flow volume · Measurement package DICOM code registration
– Doppler trace
Advanced Measurement Functions
Application Measurement Functions 24,3 • 2D wall motion tracking (USWT-AI900A is required.)
• Cardiac measurements Wall motion can be analyzed by semi-automatically
– 2D-mode measurements extracting the left ventricular myocardium from the image
· LV (left ventricular function) measurements data acquired by the system and displaying it for the eval-
· LA (left atrial volume) measurements uation of myocardial motion.
· AV (aortic valve) measurements – Wall motion tracking in 2D dynamic images
· MV (mitral valve) measurements – Wall motion information display
· PV (pulmonary valve) measurements – Polar map display
· LV MASS measurements – Local/whole myocardial wall motion parameter curve
· Auto EF measurements display
· MPI measurements (USFH-AI600A is required.) – Parameter setting display of various parameters
– M-mode measurements – Visualization of change rate for end-diastolic strain
· LV (left ventricular function) measurements (USSD-AI900A is required.)
· AV (aortic valve) measurements – Analytical data output to a file
· MV (mitral valve) measurements – RV analysis (USWT-AI902A is required.)
– Doppler measurements – Fetus mode (USWT-AI904A is required.)
· Trans-Aortic valve flow measurement • 3D Wall Motion Tracking (USWT-AI901A is required.)
· Trans-Mitral valve flow measurement Wall motion can be analyzed by semi-automatically
· Trans-Pulmonary vein flow measurement extracting the myocardium from the image data acquired
· Trans-Tricuspid valve flow measurement by the system and displaying it for the evaluation of myo-
· Trans-Pulmonary valve flow measurement cardial motion.
· Coronary measurements – Wall motion tracking in 3D dynamic images
· PISA measurements – Wall motion information display
– OB (obstetrics) measurements – Functional Imaging object display
· The data for determining fetal growth based on the – Local/whole myocardial wall motion parameter curve
measured fetal size is displayed. display
· The list of measured data or a graph of the measured – Parameter setting display of various parameters
value development (fetal growth conditions) is displayed. – Analytical data output to a file
· Week function (gestational age) – RV analysis (USWT-AI902A is required.)
· Measurement data saving is possible. – Simultaneous display of multiple analysis results (USQT-
· Auto NT measurement AI900A is required.)

25
Prism Edition

• TCA (Time Curve Analysis) (USHI-AI900A and USCQ-AI900A • RADS (Reporting And Data Systems)
are required.) (USRA-AI900A is required)
Quantitative analysis can be performed using a graph – BI-RADS™ (Breast Imaging Reporting And Data Systems)
showing the changes in intensity over time of images – TI-RADS™ (Thyroid Imaging Reporting And Data Systems)
acquired in CHI mode. – LI-RADS™ (Liver Imaging Reporting And Data Systems)
– Generation of a graph from the changes in intensity over • IOTA (International Ovarian Tumor Analysis)
time (USIO-AI900A is required)
– Motion Tracking function This function provides standardization for ovarian cancer
– Function for calculating characteristic value parameters characterization according to ADNEX (risk calculation algo-
by Curve Fitting (USCQ-AI901A is required.) rithm model) through workflow.
– Analytical data output to a file
• MVA (Mitral Valve Analysis) (USMA-AI900A is required.) Cine Memory (large-capacity image memory) 21.1.1
The mitral valve in the 3D image data acquired using the • Memory Capacity
ultrasound diagnostic system is extracted semi-automati- 960 MB 22
cally, and then it is displayed as a model so that the shape • Record/Playback Mode
of the mitral valve can be easily evaluated and analyzed to – Loop playback is possible.
display the parameters. – Frame advance playback is possible.
– Extraction of the mitral valve in the 3D image – Cine playback is possible in Doppler or M mode.
– Display of the model – Live images can be recorded. (Clips, Auto Store)
– Display of the parameters
– Extraction from mitral valve for multiple frames Video Recording
(USMA-AI901A is required.) The following DVD remote control operations are possible:
• AVA (Aortic Valve Analysis) (USAV-AI900A is required) Record, stop, play, fast-forward, rewind, forward search,
The aortic valve in the 3D image data acquired using the reverse search, and freeze (pause).
ultrasound diagnostic system is extracted semi-automati-
cally and the dimension of aortic valve complex is assessed Recording Function
with 3D model. • Printers (option)
– Black-and-white printer: USB connection
Measurement of Stored Image Data – Color printer: USB connection
The following measurements can be performed for the • Video Recording Units (Option)
DICOM data (DICOM, with raw data, and without raw data) – DVD Video
stored in HDD. • Electronic Filing
• Basic measurement – Hard disk drive
• Application measurement · Built-in HDD (SATA)
· External HDD (USB3.0)
* UZHI-AI900A and USDB-AI900A are required.
Report Function
• Worksheet functions The HDDs should meet the following specifications:
– The measurement and calculation items can be dis- Capacity: 500 GB to 6 TB
played for each application measurement. Speed: 7200 rpm or higher
– Data editing is possible (except for some items). Interface: USB 3.0 (bus power)
– Display of the following values can be set to ON or OFF. External dimension: 117 (W) × 81 (D) × 22.5 (H) mm
Mean value, latest value, maximum value, minimum value or less
– Trend graphs can be displayed (OB measurement work- Format: The following Windows® formats
sheet). (read/write compatible)
– Multi Parametric Report, which allows organization of · NTFS
results acquired using multiple abdominal measurement · FAT32 (up to 2 TB)
applications in a worksheet, can be displayed. (USDL- Other: Single partition
AI900A is required.) – DVD/CD drive
– Analysis results of RADS used during an examination can – USB flash drive
be displayed on the Worksheet. (USRA-AI900A is required.) – Network: DICOM connection
• Report function (On Board Report)
– Reports can be created on the system.
– The created reports can be printed.
– The created reports can be output as PDF files.
– The report template can be edited.
– Comment entry is possible.
26
MPDUS0212EAC

• Network Attached Storage (NAS) DICOM Function 30


(USNA-AI900A is required.) • DICOM data type
Only NAS that satisfies the following specifications can be – US Image (still image)
used: – US Multi Frame (dynamic image)
– Protocol: SMB2.0 or later – SC Image (storage in a separate file)
– LAN port: 1000BASE-T or higher – Enhanced US Volume (Volume data image)
– Capacity: 12 TB or less – Structured Report (measurement result information)
• Server connection
Security Function – Storage (Server/Media)
• Security Control – MWM (Modality Worklist Management)
This system supports a function for recording the user's – MPPS (Modality Performed Procedure Step)
authorization and access log in order to protect personal • Storage function
information. – Storage Commitment
– User authentication – Query/retrieve
– Audit Log • Standard conformity check function
– De-identification (live image/ stored image) – Verification (export/import)
• Antivirus (USSM-AI900A is required.) • Print function
Whitelist-based antivirus software is employed. The soft- – DICOM Print
ware permits only executable files registered in the
whitelist to be executed, preventing execution of malware. Signal I/O
• Transducer Connectors
Maintenance Function – Transducer connectors: 4 28,9
• Remote Maintenance (Option) – Pencil transducer
33 This function makes it possible to remotely control the connector: 1
above systems for maintenance.
(UIPC-AI900A is required.)
• Operation Status
• VCR Input/Output Signals
The system operation status can be checked by a service
– S-VHS output
engineer.
– S-VHS input
– Audio output: L, R
Image Format to Export
– Audio input: L, R
• Still: BMP/ JPEG
– DVI signals for TCS
• Movie: WMV9/ H.264
• External Video Output Signals
– Composite Video
Network
• Ethernet: 10BASE-T/ 100BASE-TX/ Gigabit – S-Video
Ethernet – HDMI
• Network client system • Internal USB
– 2.0 for printer: 2 ch
Wireless Network – 2.0 for panel: 1 ch
(UIWL-A500A or UIWL-AI900A is required.) • External USB
Wireless network connection is possible with this function. 28,10 5 USB ports (2 on the rear of the main unit, 2 on the front
• Standard of the main unit (support of USB 3.0), and 1 on the monitor
– IEEE 802.11 b/g/n 2.4 GHz (UIWL-A500A, UIWL-AI900A) side)
– IEEE 802.11 a/n/ac 5 GHz (UIWL-A500A) • Ethernet
• Security 10BASE-T/100BASE-TX/Gigabit Ethernet: 1 ch
– WPA2-PSK [AES] • SATA
– WPA2-Enterprise [AES] (conformed) – For connecting the
• Frequency built-in HDD: supporting 1 HDD
– 2.4 GHz to 2.5 GHz CCK/OFDM modulation (UIWL-A500A, – For connecting the
UIWL-AI900A) built-in SSD: supporting 1 SSD
– 5 GHz OFDM, 802.11 n MCS0-7, 802.11 ac MCS0-9 code 29 – For DVD drive: 1 ch
system (UIWL-A500A) • Footswitch (UZFS-004A is required.)
3-switch footswitch

27
Prism Edition

• 2nd Console (UITB-AI900A is required.) • According to the mode of operation:


Basic operation of the system can be performed on a tab- CONTINUOUS OPERATION
let terminal while referring to the image in real time. • Sterilization method
• Battery Mode (UEBT-AI900A is required.) – System main unit: Not suitable for sterilization.
The system can be operated in battery mode if the power – Transducers: Sterilization methods are speci-
supply from the outlet is interrupted due to fied in the relevant operation
power failure etc. manuals.

Operating Conditions Conformance Standards


Power Supply Requirements • Canada: Ed3.1
• Line voltage – General: CAN/CSA-C22.2 No. 60601-1: 14
– Japan 100 VAC ± 10% – Collateral: IEC 60601-1-2: 2014
32 – USA, Canada 120 VAC ± 10% CAN/CSA-C22.2 No. 60601-1-6A: 11
– Europe 220 to 240 VAC ± 10% – Particular: IEC 60601-2-37: 2007 + A1 2015
– Other 1 110 to 120 VAC ± 10% • EU and other regions requiring compliance with European
– Other 2 220 to 240 VAC ± 10% Directive 93/42/EEC and subsequent amendments
• Line frequency 50/60 Hz ± 1 Hz – General: EN 60601-1: 2006 + A1: 2013
• Power capacity – Collateral: EN 60601-1-2: 2015
– Japan 1500 VA – Particular: EN 60601-2-37: 2008 + A1: 2015
– USA, Canada 1440 VA • USA: Ed3.1
– Europe 1500 VA – General: AAMI ES 60601-1: 2005
– Other 1 1500 VA + C1: 2009 + A2: 2010 + A1: 2012
– Other 2 1500 VA – Collateral: IEC 60601-1-2: 2014
IEC 60601-1-6: 2010 + A1: 2013
Environmental Conditions – Particular: IEC 60601-2-37: 2007 + A1: 2015
• Operating conditions • Other regions requiring compliance with IEC 60601-1 Ed. 2
– Ambient temperature: 10°C to 35°C (20°C to 35°C when – General: IEC 60601-1: 1988 + A1: 1991 + A2: 1995
a 4D transducer is used) – Collateral: IEC 60601-1-1: 2000
– Relative humidity: 35% to 80% (no condensation) IEC 60601-1-2: 2001 + A1: 2004
– Atmospheric pressure: 700 hPa to 1060 hPa IEC 60601-1-4: 1996 + A1: 1999
• Storage conditions – Particular: IEC 60601-2-37: 2001 + A1: 2004 + A2: 2005
– Ambient temperature: -10°C to 50°C • Other regions requiring compliance with IEC 60601-1 Ed. 3
– Relative humidity: 30% to 90% (no condensation) – General: IEC 60601-1: 2005
– Atmospheric pressure: 700 hPa to 1060 hPa – Collateral: IEC 60601-1-2: 2007
– Particular: IEC 60601-2-37: 2007
Safety Classification • Other regions requiring compliance with IEC 60601-1 Ed. 3.1
• According to the type of protection against electric shock: – General: IEC 60601-1: 2005 + A1: 2012
CLASS I or Internally Powered Equipment – Collateral: IEC 60601-1-2: 2007
• According to the degree of protection against electric – Particular: IEC 60601-2-37: 2007 + A1: 2015
shock: * The above standards are applicable to the ultrasound system at the
EQUIPMENT WITH TYPE-BF APPLIED PARTS (Transducer, time of purchase.
ECG electrodes, PCG, Pulse) These standards continue to remain applicable even if the system
configuration is changed as a result of using options in combina-
• According to the degree of protection against harmful
tion.
ingress of water: The standards for the ultrasound system are also applicable to
IPX0 (enclosed EQUIPMENT without protection against transducers.
ingress of water)
However, the footswitch is IPX8 and the transducers are
IPX7 (excluding the connector part).
• According to the degree of safety of application in the
presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR
or WITH OXYGEN OR NITROUS OXIDE:
EQUIPMENT not suitable for use in the presence of a
FLAMMABLE ANESTHETIC MIXTURE WITH AIR or WITH
OXYGEN OR NITROUS OXIDE
28
MPDUS0212EAC

DIMENSIONS, MASS, AND POWER CONSUMPTION


External dimensions Mass
mm (in) Power consumption
Unit Model name kg (lb) (approx.)
Width Height Depth (approx.)
1177 (46.3) 969 (38.1) 570 VA
TUS-AI900/ AI800/ AI700 631*1 (24.8) to to to to 115 (253.5)
1757 (69.2) 1069 (42.1) 27 VA*2
Main unit Height adjusted model of
TUS-AI900/ AI800/ AI700 1237 (48.7) 969 (38.1) 570 VA
631*1 (24.8) to to to to 115 (253.5)
(Available only in USA, Europe 1817 (71.5) 1069 (42.1) 27 VA*2
and Australia)

287.7 (11.3)
Sony HVO-550MD/FHD (including
DVD video recorder 212 (8.4) 105.5 (4.2) 3.2 (7.1) 43.2 W
[NTSC/PAL]
the projection
section)
Sony UP-D711MD/AC 140 (5.5) 70 (2.8) 125 (4.0) 1.0 (2.2) 72 VA (printing)

Sony UP-D898MD 154 (6.1) 88 (3.5) 240 (9.4) 2.6 (5.7) 190 VA (printing)
B/W digital printer
Mitsubishi P95DW 154 (6.1) 84.5 (3.3) 130 (5.1) 2.6 (5.7) 190 VA (printing)

Mitsubishi P95DW-DC 154 (6.1) 84.5 (3.3) 130 (5.1) 1.6 (3.5) 68 VA (printing)

Mitsubishi CP30DW 212 (8.3) 125 (4.9) 425 (16.7) 7.3 (16.1) 180 VA (printing)
Color digital printer
Sony UP-D25MD 212 (8.3) 98 (3.9) 398 (15.7) 5.5 (12.1) 240 VA (printing)

*1: 580 mm in length when the provided transducer connector holder is removed.
*2: In Standby mode with internal battery UEBT-AI900A.

29
Prism Edition

MASS
Model name Name of component Mass [kg] (lb) Model name Name of component Mass [kg] (lb)
System main unit USVS-AI900A 4D ADF/SMI kit 0.1 (0.2)
TUS-AI900 Aplio900 110 (242.5) USVC-AI900A 4D CHI kit 0.1 (0.2)
TUS-AI800 Aplio800 110 (242.5) USPF-AI900A 3D printer format export kit 0.1 (0.2)
TUS-AI700 Aplio700 110 (242.5) USEL-AI901A Elastography-FLR kit 0.1 (0.2)
Options/Accessories for main unit USEL-AI900A Elastography kit 0.1 (0.2)
USCW-AI900A CW kit 0.1 (0.2) USSW-AI900A Shear Wave kit 0.1 (0.2)
USUR-AI900A Reference Signal kit 0.1 (0.2) USSW-AI901A Shear wave Hard kit 0.1 (0.2)
UJUR-AI900A Reference signal cable 0.3 (0.7) USQS-AI800A 0.1(0.2) 0.1 (0.2)
UJUR-AI901A Reference signal cable 0.1 (0.2) USDM-AI900A Dispersion Map for SWE kit 0.1 (0.2)
UJUR-AI902A Reference signal sensor unit 0.4 (0.9) USFN-AI900A Smart Fusion kit 0.1 (0.2)
USSE-AI900A Stress Echo kit 0.1 (0.2) USSN-AI900A Smart Navigation kit 0.1 (0.2)
USWT-AI900A 2D Wall Motion Tracking kit 0.1 (0.2) UIFR-AI900A Magnetic Generator kit 15.0 (33.0)
USWT-AI904A 2D Wall Motion Tracking Fetal kit 0.1 (0.2) UIFR-A501A Sensor kit for Fusion unit 0.1 (0.2)
USWT-AI906A 2D Wall Motion Tracking kit 0.1 (0.2) USFN-AI901A Auto Registration kit 0.1 (0.2)
USSD-AI900A SI-DI kit 0.1 (0.2) UZWT-A500A Fusion Pole Cart 26 (57.3)
USWT-AI901A 3D Wall Motion Tracking kit 0.1 (0.2) UAFS-001A Mounting kit for fusion sensor 0.1 (0.2)
USWT-AI902A 3D Wall Motion Tracking Advance kit 0.1 (0.2) UAFS-002A Mounting kit for fusion sensor 0.1 (0.2)
USQT-AI900A Quad Chamber Tracking kit 0.1 (0.2) UAFS-003A Mounting kit for fusion sensor 0.1 (0.2)
USMA-AI900A Mitral Valve Analysis kit 0.1 (0.2) UAFS-004A Mounting kit for fusion sensor 0.1 (0.2)
USMA-AI901A MVA 4D kit 0.1 (0.2) UAFS-005A Mounting kit for fusion sensor 0.1 (0.2)
USVM-AI800A Volume Matrix kit 0.1 (0.2) UAFS-006A Mounting kit for fusion sensor 0.1 (0.2)
USVM-AI700A Volume Matrix 2 kit 0.1 (0.2) UAFS-007A Mounting kit for fusion sensor 0.1 (0.2)
Luminance and Shadow Glass with UAFS-008A Mounting kit for fusion sensor 0.1 (0.2)
USLM-AI901A 0.1 (0.2)
Volume Matrix kit UAFS-009A Mounting kit for fusion sensor 0.1 (0.2)
USAV-AI900A AVA kit 0.1 (0.2) UAFS-010A Mounting kit for fusion sensor 0.1 (0.2)
USFH-AI600A Fetal Heart MPI Measurement kit 0.1 (0.2) UAFS-011A Mounting kit for fusion sensor 0.1 (0.2)
USFP-AI900A Smart Fetal Heart kit 0.1 (0.2) USMB-AI900A Breast Scan Guide kit 1.0 (2.2)
UIPC-AI900A Pencil Connector unit 0.2 (0.4) USSB-AI900A Smart Body Mark kit 1.0 (2.2)
UAEH-AI900A M-TEE hanger kit 1.5 (3.3) USSS-AI900A Smart Sensor 3D kit 0.1 (0.2)
UAEH-AI901A TEE hanger kit 1.2 (2.6) USMP-AI900A MicroPure kit 0.1 (0.2)
UACV-AI900A CV kit 1.0 (2.2) USPV-AI900A Panoramic View kit 0.1 (0.2)
UIST-AI900A STC kit 0.1 (0.2) USRC-AI900A Multi-reflection Canceller kit 0.1 (0.2)
UIST-AI901A STC kit 0.1(0.2) USLP-Al900A Liver Package kit 0.1 (0.2)
Ultrasound scanning condition USLD-AI900A Doppler Luminance kit 0.1 (0.2)
USVL-AI900A 0.1 (0.2)
export function Kit
USGI-AI900A General Imaging kit 0.1 (0.2)
USHI-AI900A CHI kit 0.1 (0.2)
USAT-AI900A Attenuation Imaging kit 0.1 (0.2)
USCQ-AI900A CHI-Q kit 0.1 (0.2)
USSL-AI900A Slice thickness control kit 0.1 (0.2)
USCQ-AI901A Fitting Curve kit 0.1 (0.2)
USZS-AI900A Measurement Z score kit 0.1 (0.2)
USQC-AI800A Quad view for CHI kit 0.1 (0.2)
UAOB-Al900A OB kit 0.1 (0.2)
USHI-AI901A High frame rate CHI kit 0.1 (0.2)
USTM-Al900A Limb Volume Measurement kit 0.1 (0.2)
USVF-AI900A Contrast Vector Imaging kit 0.1 (0.2)
UZRI-AI900A Mounting kit for peripheral unit 1.1 (2.4)
USMV-AI900A 4D kit 0.1 (0.2)
UZRI-AI901A Mounting kit for peripheral unit 0.6 (1.3)
USLM-AI900A Luminance kit 0.1 (0.2)
UZRI-AI902A Mounting kit for peripheral unit 3.1 (6.8)
USFT-AI900A Fly Thru. kit 0.1 (0.2)
UZRI-Al903A Mounting kit for peripheral unit 0.6 (1.3)
USSG-AI900A Shadow Glass kit 0.1 (0.2)
UZRI-Al904A Mounting kit for peripheral unit 4.6 (10.1)
USOB-AI900A Auto Volume Measurement kit 0.1 (0.2)
30
MPDUS0212EAC

Model name Name of component Mass [kg] (lb) Model name Name of component Mass [kg] (lb)
UZFS-004A Footswitch 0.6 (1.3) PSI-30VX Phased array transducer 0.8 (1.8)
UZGW-008A Gel warmer 1.0 (2.2) PSI-40VX Phased array transducer 0.85 (1.9)
UZMK-AI900A Transducer cable hanger kit 0.9 (2.0) PSI-50VX Phased array transducer 0.75 (1.7)
UZBK-AI900A Transducer Holder kit 0.3 (0.7) PSI-70BT Phased array transducer 0.65 (1.4)
UIWL-A500A Wireless LAN kit 0.5 (1.1) PST-25BT Phased array transducer 0.8 (1.8)
UIWL-AI900A Wireless LAN kit 0.5 (1.1) PST-28BT Phased array transducer 0.67 (1.5)
UZPH-AI900A EV/ER Transducer Holder kit 1.6 (3.5) PST-30BT Phased array transducer 0.8 (1.8)
UIKB-AI900A Keyboard kit 1.1 (2.4) PST-50BT Phased array transducer 0.8 (1.8)
UITB-AI900A 2nd Console kit 1.1 (2.4) PST-65BT Phased array transducer 0.73 (1.61)
UIOM-001A OLED Monitor 4.1 (9.0) PVI-482BX Convex array transducer 0.7 (1.5)
USDB-AI900A DataBase for External HDD kit 0.1 (0.2) PVI-475BT Convex array transducer 0.75 (1.7)
UZHI-AI900A Mounting kit for External HDD kit 1.0 (2.2) PVI-450BXP Convex array transducer 0.8 (1.76)
UZMK-AI902A ECG Cable Hanger kit 0.1 (0.2) PVI-475BX Convex array transducer 0.8 (1.8)
UIUB-AI900A Panel USB Port kit 0.1 (0.2) PVI-574BX Convex array transducer 0.75 (1.7)
UZPT-001A Palm Controller kit 0.2 (0.4) PVT-350BTP Convex array biopsy transducer 0.95 (2.1)
UZPT-002A Palm Controller kit 0.2(0.4) PVT-375BT Convex array transducer 0.95 (2.1)
UEBT-AI900A Battery unit 13 (28.7) PVT-375SC Convex array transducer 0.95 (2.1)
USHE-AI900A Online Help kit 0.1 (0.2) PVT-382BT Convex array transducer 0.8 (1.8)
USPA-AI900A Protocol Assistant kit 0.1 (0.2) PVT-482BT Convex array transducer 0.75 (1.7)
USPA-AI901A MSK Protocol Movie kit 0.1(0.2) PVT-574BT Convex array transducer 0.75 (1.7)
USDL-AI900A Multi Parametric Report kit 0.1 (0.2) PVT-674BT Convex array transducer 0.9 (2.0)
UAWH-AI900A Woman Helthcare kit 0.1 (0.2) PVT-675MVL Convex array transducer 1.1 (2.4)
USSM-AI900A Security Management kit 0.1 (0.2) PVT-675MVS Convex array transducer 1.05 (2.3)
USRA-AI900A RADS kit 0.1 (0.2) PVT-681MVL Endocavitary transducer 1.15 (2.5)
USIO-AI900A IOTA kit 0.1 (0.2) PVT-712BT Convex array transducer 0.8 (1.8)
USUH-AI700A Ultra High Freq kit 0.1 (0.2) PVT-745BTF Convex array transducer 0.8 (1.8)
UZTB-Al900A Track Ball kit 0.2 (0.4) PVT-745BTH Convex array transducer 0.8 (1.8)
UZTB-AI901A Track Ball kit 0.2(0.4) PVT-745BTV Convex array transducer 0.78 (1.7)
UZKF-AI900A Local Language Key-Top kit 0.5 (1.1) PVT-770RT Endocavitary transducer 2.0 (4.4)
UZKG-AI900A Local Language Key-Top kit 0.5 (1.1) PVT-781VT Endocavitary transducer 0.97 (2.1)
UZKI-AI900A Local Language Key-Top kit 0.5 (1.1) PVT-781VTE Endocavitary transducer 0.97 (2.1)
UZKS-AI900A Local Language Key-Top kit 0.5 (1.1) PVL-715RST Endocavitary transducer 1.04 (2.3)
UZKD-AI900A Local Language Key-Top kit 0.5 (1.1) PLI-705BX Linear array transducer 0.83 (1.8)
UZKN-AI900A Local Language Key-Top kit 0.5 (1.1) PLI-605BX Linear array transducer 0.83(1.8)
UZKW-AI900A Local Language Key-Top kit 0.5 (1.1) PLI-1205BX Linear array transducer 0.78 (1.7)
UZKR-AI900A Local Language Key-Top kit 0.5 (1.1) PLI-2002BT Linear array transducer 0.75 (1.7)
HVO-550MD/ PLI-2004BX Linear array transducer 0.78 (1.7)
DVD video recorder 3.2 (7.1)
FHD PLI-3003BX Linear array transducer 0.81 (1.8)
UP-D711MD/AC B/W printer 1.0 (2.2) PLT-308BTP Linear array biopsy transducer 0.8 (1.8)
UP-D898MD B/W printer 2.6 (5.7) PLT-704SBT Linear array transducer 0.9 (2.0)
P95DW B/W printer 2.6 (5.7) PLT-705BT Linear array transducer 0.85 (1.9)
P95DW-DC B/W printer 1.6 (3.5) PLT-705BTF Linear array transducer 0.78 (1.7)
CP30DW Color printer 7.3 (16.1) PLT-705BTH Linear array transducer 0.78 (1.7)
UP-D25MD Color printer 5.5 (12.1) PLT-1005BT Linear array transducer 0.85 (1.9)
Transducers PLT-1202BT Linear array transducer 0.75 (1.7)
PSI-30BX Phased array transducer 0.67 (1.5) PLT-1204BT Linear array transducer 0.85 (1.9)

31
MPDUS0212EAC
Prism Edition

Model name Name of component Mass [kg] (lb)


PEI-512VX Multi-plane transesophageal transducer 1.6 (3.5)
PET-508MA Multi-plane transesophageal transducer 1.2 (2.6)
PET-609MA Multi-plane transesophageal transducer 1.3 (2.87)
PET-512MA Multi-plane transesophageal transducer 1.32 (2.9)
PET-512MC Multi-plane transesophageal transducer 1.6 (3.5)
PET-512MD Multi-plane transesophageal transducer 1.5 (3.3)
PET-805LA Linear array transducer 1.17 (2.6)
PC-20M CW Doppler pencil transducer 0.085 (0.2)
PC-50M CW Doppler pencil transducer 0.08 (0.2)

1385, Shimoishigami, Otawara-shi, Tochigi 324-8550, Japan

https://global.medical.canon
©Canon Medical Systems Corporation 2020-2021. All rights reserved.
Design and specifications are subject to change without notice.
Model number: TUS-AI900/AI800/AI700 MPDUS0212EAC V6.0 2021-05 CMSC/Produced in Japan

Canon Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485.
Canon Medical Systems Corporation meets the Environmental Management System standard ISO 14001.

Aplio, Dynamic Flow, ApliPure, MicroPure, Pulse Subtraction, VolPure, TwinView and Made for Life are trademarks of Canon Medical Sys-
tems Corporation.
Windows and AppLocker are registered trademarks of Microsoft Corporation in the United States and / or other countries.
McAfee is a registered trademark of McAfee Associates, Inc.
omniTRAX and VirtuTRAX are trademarks of CIVCO Medical Solutions.
BI-RADS, TI-RADS and LI-RADS are trademarks of the American College of Radiology.
This document may include trademarks or registered trademarks of their respective owners.

The contents of this document are limited to standard specifications.


Please consult with your regulatory department for local approved product specifications and usage.
TRANSDUCERS
For Ultrasound Systems
iBeam Forming iBeam Slicing Volume Matrix for Radiology Volume Matrix for Cardiology
Multi-Sync Pulser intelligent Dynamic Micro-Slice Real time 3D transducer Matrix array 3D TEE (Transesophageal) transducer
Able to drive simultaneously pure waveforms with high precision creating a
fine beam focus in the depth direction.
( iDMS ) Provides high speed and precise volume imaging, and
is compatible with SMI, CEUS, Biopsy and full range of
Matrix array
Creates a thin slice beam with continuous focus from near sensors and adapters Acquires high resolution volume data in a short time, with high
Multi-Beam Receiver field to far field by controlling the main and side elements resolution, high volume rate and multi-plane display.
separately.
Enable to receive multiple simultaneous signals at high speed across a wide
signal area, resulting in improved lateral and temporal resolution combined
Trans-thoracic real time 3D transducer
with higher frame rates. Provides wide area of real time 3D images and 3D color Doppler
images.
Multi-Harmonic Compounding
Merges signals from individual beams with overlapping data from adjacent
beams, virtually transforming each of them into thin, straight homogeneous
beams, creating higher spatial resolution, contrast resolution and less
artifacts.

Volume Matrix

Volume Matrix

intelligent
DMS

2 3
V 4.0 V 4.0 V 4.0 V 4.0

PST- 25BT 2 27,7 PVT - 375BT PVT - 482BT PVT - 712BT 27,6

*
PSI-40VX PLT-1202BT
Sector

Sector

Convex

Convex

Convex

Linear
1 2.5 1.7~4.7 Volume 1 4.0 1.8~6.0 1 3.5 1.5~6.0 1 4.0 1.8~6.0 1 7.0 4.3~11.0 1 12.0 4.5~17.0

2 Approx. 90° - Matrix 2 Approx. 120° - 2 Approx. 70° Approx. 50mm 2 Approx. 80° Approx. 20mm 2 Approx. 100° Approx. 15mm 2 Approx. 25.6mm -
Cardiac (adult heart), Neonatal head, abdominal, Small parts (superficial), MSK,
3 3 3D Abdominal, fetal, pediatric 3 Abdominal, fetal, pediatric 3 Abdominal, pediatric, fetal 3 3
Transcranial Doppler pediatric intraoperative
4 680-106 680-086 610-608 4 680-156 680-157 610-1500/1502 4 680-105 680-085 610-608 4 - - 610-1500/1502 4 680-127 680-126 610-608 4 - - -
5 - 5 - 5 - 5 - 5 - 5 -
6 - 6 UAFS-009A 6 Included with UIFR-AI900A 6 UAFS-001A 6 - 6 UAFS-010A
7 - Single Crystal 7 - 7 - Single Crystal 7 - 7 - 7 -

5S1 i6SVX2 6C1 8MC1 11MC4 17LH7

PST- 28BT PST- 50BT 2


PLT- 704SBT 27,5 PLT- 1204BT

*
PVT-375SC PVI-482BX

Linear
1 3.0 1.5~6.0 1 5.0 3.0~8.2 1 3.5 1.5~6.0 intelligent 1 4.0 1.8~6.0 1 7.5 4.0~10.5 1 12.0 4.5~18.0

2 Approx. 120° - 2 Approx. 90° - 2 Approx. 70° Approx. 50mm DMS 2 Approx. 80° Approx. 20mm 2 Approx. 38mm - 2 Approx. 38mm -
Cardiac (adult heart), Cardiac Peripheral vascular (carotid, Small parts
3 3 3 Abdominal, fetal, pediatric 3 Abdominal, fetal, pediatric 3
Transcranial Doppler (pediatric, neonatal heart) lower leg), small parts, MSK 3 (superficial, breast), MSK,
peripheral vascular
4 - - - 4 - - - 4 680-105 680-085 610-608 4 - - 610-1500/1502 4 680-107 680-087 610-608
680-102 680-088 610-608
5 - 5 - 5 - 5 - 5 -
4 610-1231
6 UAFS-009A 6 - 6 Included with UIFR-AI900A 6 UAFS-001A 6 - 680-123 680-122
610-1235
Single Crystal 7 - 7 - Single Crystal 7 - Single Crystal 7 - 7 - 5 -

6S1 6S3 6Cs1 i8MCX1 11L4 18L7 6 -

7 UACK-004A

PST- 30BT PSI - 50VX 2


PVT - 382BT PVT - 574BT PLT- 705BT PLI- 1205BX 2 27,3
*

*
1 3.0 1.7~5.2 Volume 1 5.0 2.2~6.0 1 3.5 2.0~5.0 1 5.0 2.0~9.5 1 7.0 3.0~8.5 intelligent 1 12.0 4.0~18.2
2 Approx. 90° - Matrix 2 Approx. 90° - 2 Approx. 80° Approx. 20mm 2 Approx. 65° Approx. 40mm 2 Approx. 45mm - DMS 2 Approx. 46mm -
Cardiac (adult heart), 3D Cardiac Peripheral vascular (lower leg, Small parts (breast), MSK,
3 3 3 Abdominal, pediatric, fetal 3 Abdominal, fetal, pediatric 3 3
Transcranial Doppler (pediatric, neonatal heart) carotid), small parts, MSK peripheral vascular
4 680-106 680-086 610-608 4 - - - 4 680-111 680-110 680-112 4 680-168 680-169 610-1500 4 680-129 680-128 610-608 680-139 680-138 610-608
5 - 5 - 5 UAGV-027A 5 - 5 - 680-149 680-148 610-1500
4
6 - 6 UAFS-009A 6 UAFS-001A 6 UAFS-008A 6 - 610-1017
680-132 680-133 610-1018
7 - Single Crystal 7 7 - Single Crystal 7 - 7 - 610-1019

5S2 i7SVX2 6MC1 10C1 11L3 i18LX5 5 -

6 UAFS-008A

7 UACK-004A
PSI- 30BX 2
PVI - 475BT 2
PLI- 705BX 2
*

*
PST-65BT PVI-574BX
2
PLI- 2002BT

*
intelligent 1 3.0 1.5~6.0 1 7.0 3.5~12.0 1 4.0 1.8~6.4 intelligent 1 5.0 2.0~9.5 intelligent 1 7.0 3.5~11.5
DMS 2 Approx. 120° - 2 Approx. 120° - 2 Approx. 70° Approx. 50mm DMS 2 Approx. 65° Approx. 40mm DMS 2 Approx. 46mm - 1 20.0 8.8~22.0
Cardiac (adult heart), 3 Abdominal, fetal, pediatric Peripheral vascular (lower leg, 2 Approx. 25.6mm -
3 3 Cardiac (pediatric heart) 3 Abdominal, fetal, pediatric 3
Transcranial Doppler carotid), small parts, MSK
680-145 680-144 610-608 Small parts (superficial), MSK,
4 - - - 4 - - - 4 4 680-166 680-167 610-1500 680-150 680-151 610-1500 3
intraoperative
680-155 680-154 610-1500
5 - 5 - 5 - 4 610-1017 4 - - -
5 - 680-164 680-165 610-1018
6 UAFS-009A 6 - 6 UAFS-008A 610-1019 5 -
UAFS-007A
Single Crystal 7 - 7 - Single Crystal 6 Single Crystal 7 - 5 -
(included with UIFR-AI900A) 6 UAFS-010A

i6SX1 12S4 i8C1 7 - i10CX1 i11LX3 6 UAFS-008A 7 -


7 - i22LH8
27.1 27,4
PSI- 30VX 2
PSI - 70BT PVI - 475BX 2
PVT - 674BT PLT- 1005BT
*

Volume 1 3.0 1.8~5.2 1 7.0 3.5~9.0 intelligent 1 4.0 1.8~6.4 1 6.0 3.5~9.7 1 10.0 3.8~14.0 1 Frequency (MHz) Displayed range of freq. (MHz)

Matrix 2 Approx. 120° - 2 Approx. 90° - DMS 2 Approx. 70° Approx. 50mm 2 Approx. 65° Approx. 40mm 2 Approx. 58mm - 2 Field of view / angle Curvature

3 3D Cardiac (adult heart) 3 Cardiac (neonatal heart) 3 Abdominal, fetal, pediatric 3 Abdominal, fetal, pediatric Small parts (breast), MSK, 3 Indication for use
3
peripheral vascular 1

*
680-143 680-142 610-608 4 Starter Ki t Bracket Needle guide
4 680-156 680-157 610-1500/1502 4 - - - 4 4 - - -
680-109 680-090 610-608
680-153 680-152 610-1500 5 Reusable biopsy adapter
5 - 5 - 5 UAGV-028A 4
5 - 610-1231 6 Fusion adapter
680-125 680-124
6 UAFS-009A 6 - 6 - 610-1235
UAFS-007A 7 Water bag / Sono coupler
Single Crystal 7 - 7 - Single Crystal 6 7 - 5 -
(included with UIFR-AI900A)
1 Includes the bracket and the sterile procedure kit.

* *
i6SVX1 i10S4 i8CX1 7 - 10C3 14L5 6 UAFS-004A 2 Not compatible with Aplio i600

7 Water bag UAWB-022A

4 5
V 4.0 V 4.0 V 4.0 V 4.0

PLI- 2004BX 2
PVL- 715RST PVT- 745BTV PET - 805LA
*
Linear

Endorectal

Intraoperative

Laparoscopic
intelligent 1 20.0 8.8~24.0 1 7.5 4.5~9.0 1 7.0 3.2~10.0 1 8.0 3.5~9.0
DMS 2 Approx. 41mm - Approx. 170° 2 Approx. 40° Approx. 45mm 2 Approx. 45mm -
2 Approx. 10mm
Approx. 56mm
Intraoperative, abdominal,
3 Small parts (superficial), MSK 3 3 Laparoscopic
3 Prostate, bladder small parts
680-137 680-136 610-608 4 - - - 4 - - -
4 - - -
680-147 680-146 610-1500 5 UAGV-029A 5 -
4 UAGL-001AHA
5
610-1017 UAGL-002AHA 6 - 6 -
680-134 680-135 610-1018
610-1019 6 UAFS-005A 7 - 7 -

i24LX8 5 - 11CL4 7 - 11CI4 12LI4


6 UAFS-008A
7 UACK-004A
PVT- 770RT PVT- 745BTF PET - 508MA PEI - 512VX 2
PVT- 681MVL

*
Transesophagus

Transesophagus

Mechanical 4D
1 7.0 4.7~10.0 1 7.0 3.0~10.0 1 5.0 2.5~7.0 Volume 1 5.0 1.8~6.0 1 6.0 3.6~11.0

2 Approx. 170° Approx. 10mm 2 Approx. 40° Approx. 45mm 2 Approx. 90° - Matrix 2 Approx. 90° - 2 Approx. 180° Approx. 10mm
2
PLI- 3003BX
*

Intraoperative, abdominal, Cardiac pediatric Transvaginal uterus, ovary,


3 Prostate, bladder 3 3 3 Cardiac (Motor drive 3D TEE) 3
small parts (Manual TEE) prostate
intelligent 1 30.0 10.0~33.0
4 - 680-093 680-092 4 - - - 4 - - - 4 - - - 4 - - 680-131
DMS 2 Approx. 31mm -
5 UAGV-023A 5 - 5 - 5 - 5 -
3 Small parts (superficial), MSK
6 - 6 - 6 - 6 - 6 -
4 - 7 - 7 - 7 - Single Crystal 7 - 7 -
5 - 10C5 11CI4 7S3 i6SVX2 11CV3
6 UAFS-008A
7 -
3
PC - 20M

*
PET-609MA

Pencil
PLT- 308BTP 3
PVT - 745BTH PET - 512MA 3
*

*
i33LX9
Biopsy

1 6.0 3.6~7.5 1 2.0 -


1 3.75 2.0~5.5 1 7.0 3.0~10.0 1 5.0 3.0~6.5
2 Approx. 90° - 2 - -
2 Approx. 85mm - 2 Approx. 40° Approx. 45mm 2 Approx. 90° -
3 Abdominal puncture Intraoperative, abdominal, 3 Cardiac pediatric (Manual TEE) 3 Cardiac, CW only
3 3 Cardiac (Manual TEE)
small parts
27,2 4 - - - 4 - - - 4 - - -
PVT- 781VT 4 - - - 4 - - -
Endocavity

UAGL-004AHA 5 - 5 -
5 5 UAGV-034A 5 -
1 7.0 3.6~11.0 (included with transducer)
6 - 6 -
6 - 6 - 6 -
2 Approx. 180° Approx. 10mm
7 - 7 -
7 - 7 - 7 -
3 Transvaginal uterus, ovary 8S3 P2
6LP3 11CI4 8S2
4 - - 680-121
5 UAGV-035A
PVT- 675MVL PC - 50M

Mechanical 4D
6 UAFS-003A
PVT- 350BTP 3
PLT - 705BTF PET- 512MC
*

7 - 1 6.0 2.5~7.0 1 5.0 -


1 3.5 2.0~4.5 1 7.0 3.8~8.4 1 5.0 3.0~6.5
2 Approx. 66° Approx. 50mm 2 - -
11C3 2 Approx. 70° Approx. 50mm 2 Approx. 46mm - 2 Approx. 90° -
Cardiac, CW only,
3 Fetal, abdominal 3
3 Abdominal puncture Intraoperative, abdominal, peripheral vascular
3 3 Cardiac (Motor drive TEE)
small parts
4 - - - 4 - - - 4 - - -
4 - - - 4 - - -
UAGV-030A 5 - 5 -
5 5 UAGV020A 5 -
(included with transducer)
6 - 6 -
6 UAFS-002A 6 - 6 -
7 - 7 -
7 - 7 - 7 -
9CV2 P5
PVT- 781VTE 6CP1 11LI4 8SM2
1 7.0 3.6~11.0
3
PLT - 705BTH PET - 512MD
*

2 Approx. 180° Approx. 10mm PVI-450BXP PVT-675MVS


Transvaginal uterus, ovary intelligent 1 4.0 1.8~6.2 1 7.0 3.8~8.4 1 5.0 3.0~8.5 1 6.0 2.5~7.5 1 Frequency (MHz) Displayed range of freq. (MHz)
3 (longer insertion length than DMS 2 Approx. 70° Approx. 50mm 2 Approx. 46mm - 2 Approx. 90° - 2 Approx. 70° Approx. 48mm 2 Field of view / angle Curvature
PVT-781VT)
3 Abdominal puncture Intraoperative, abdominal, 3 Indication for use
4 - - 680-121 3 3 Cardiac (Motor drive TEE) 3 Fetal, abdominal
small parts
1

*
4 - - - 4 Starter Ki t Bracket Needle guide
5 UAGV-035A 4 - - - 4 - - - 4 - - -
5 - 5 Reusable biopsy adapter
6 UA FS -006A 5 UAGV020A 5 - 5 -
6 UAFS-011A 6 Fusion adapter
11C3 7 - 6 - 6 - 6 -
7 - 7 Water bag / Sono coupler
Single Crystal 7 - 7 - 7 -
1 Includes the bracket and the sterile procedure kit.

* * *
i8CXP1 11LI4 8SM2 9CV2 2
3
Not compatible with Aplio i600
Not available in the USA and Canada

6 7
Tender Specs

Caution: This is only for tender purpose. Please don't disclose this information for any other purpose.

Category Item i900/i800/i700 V5.1

System Height [mm] (Panel height up) 1,177-1,757 (1,237-1,817)


Dimension Width [mm] 580
Depth [mm] 969-1,069
Weight Weight [kg] 115Kg (116Kg if pannel Upped)
Power consumption 1,500VA
Power capacity 570VA
Power
Max value for peripherals 190VA for B/W printer
Stand-by mode 27VA
Stand-by Yes
battery Battery pack Yes (30min)
Length of standby mode with battery 5H
Cold boot up 60 sec
Start-up time
Boot up from standby Approx. 35 sec
CPU Type
Aplio i900/800/700 Intel Core i7-8700 3.2 GHz

CPU RAMCPU memory 16 GB


Hard Disk capacity
(It is not the capacity for image
storage)
Aplio i900/800/700 256GB (SSD) + 1TB (HDD)

Hard disk size for image saving


Aplio i900/800/700 SSD (256GB)/HDD (769GB)/External HDD (6TB) 28,8

DSC size 960 MB


Cine loop / Max Cine Loop 960 MB / 10,000 frames
Doppler 213 sec
Storage M 30 sec
B 180 sec
USB 3.0/2.0
CD-R speed x24(Front loading)
DVD+R speed x8 (Front loading)
DVD RW x6, x8
DVD recorder with digital interface Yes
Monitor Monitor type LCD/OLED(Opt)
Size (inch) 23"/21.6"(Opt)
Display matrix 1,920 x 1,080 / 3,840 x 2,160
Viewing angle 178 /178
Contrast ratio typ. 1000:1 / 1000000: 1
Response speed (ms) 14 / typ. 40 (30 + 10) *Black-> White-> Black

Luminance (cd/m2) typ. 300 / typ. 200 (7500 K), typ. 145 (13000 K)

Other specs IPS


Articulating arm Yes 28,6,1
Adjustable height Yes 28,6,1
Monitor swivel +/- 360 degrees and more 28,6,1
Screen tilt angle up/down +20/-90 degrees 28,6,1
Operation Panel Size / resolution of TCS 12.1" / 1,280 x 800
TCS tilt angle +15º
Panel swivel ±40º
Panel back and forth Yes
Panel height-Max (Panel height up) 991 (1,051)
Panel height-Min (Panel height up) 630 (690)
# of transducer 4
Transducer connector
# of Pencil transducer 1
Wheel Double wheelCenter lock
Fan noise level 38.35 dB
Number of bit of the A/D converter 14 bit
Maximum simultenous
transmission focal 8
points
Zoom steps 32
Category Item i900/i800/i700 V5.1

Common Dual image / TwinView Yes


Display format
Quad View Yes
Programable workflows Protocol Assistant/w Graphical icon
Work flow
Wireless second console Yes (Opt)
Imagin Preset Numbers Factory Preset 24
User Preset freeley 40
Sub Preset 8 for each user preset
Examination Type numbers 4
Measurement Preset numvers 10 for each Examination type
Application preset numbers 40
System preset numbers 1
Oblique and trapezoid scan angle for linear transducers
Oblique 2004BX B=±10 deg, CDI=±10 deg
1205BX B=±10 deg, CDI=±30 deg
1204BT B=±10 deg, CDI=±20 deg
1005BT B=±10 deg, CDI=±20 deg
705BT B=±10 deg, CDI=±30 deg
704SBT B=±10 deg, CDI=±30 deg

WideView 2004BX B=±20 deg, CDI=±18 deg


1205BX B=±10 deg, CDI=±8 deg
1204BT B=±20 deg, CDI=±18 deg
1005BT B=±10 deg, CDI=±8 deg
705BT B=±20 deg, CDI=±18 deg
704SBT B=±30 deg, CDI=±28 deg

Actual PRF range PWD 0.3 - 39.7 kHz (PST-50BT)


CWD 1.4 - 52.1 kHz (PST-50BT)
CDI 0.1 - 27.6 kHz (PLI-1205BX)
0.1 - 27.6 kHz (PLI-1204BT)
(i600 does not support PLI-1205BX)
<Max. Frame rate>
B 2089 fps (@PST-50BT/other) 9,4
Color 448 fps (@PST-50BT/other)
Power 437 fps (@PST-50BT/other)
ADF 204 fps (@PST-50BT/other)
SMI 60 fps
TDI 1351 fps (@PST-50BT/other)
Max display depth 50 cm
B-mode B-mode gain range 60 - 100 dB
STC gain range +/- 30 dB
Maximum length of Panoramic View approx. 180cm 13,1
Image grey levels 256 shades of grey
Minimum scan angle 10 degrees (PST-25BT)
Max. scan line number Convex over 350 lines @ PVT-781VTE
Sector over 350 lines @ PSI-70BT
Linear over 500 lines @ PLI-2004BX
over 350 lines @ PLT-1204BT

(i600 does not support PLI-2004BX)


Max. zoom factor approx. 27.1 times

Maximum velocity range in color mode ±191.3 cm/s (with PVT-375BT)

Color Color map Velocity 15 types


Velocity-Variance 15 types

Color display gradation Velocity +/- 128 steps


Power +/- 128 steps
Turburance 128 steps

Color velocity range for each transducer


PVI-475BT Lowest Velocity 1.1cm/s
Highest Velocity 191.3 cm/s

PVI-475BX Lowest Velocity 1.1 cm/s


Highest Velocity 191.3 cm/s

PLI-1205BX Lowest Velocity 0.6 cm/s


Highest Velocity 239.1 cm/s

PLT-1204BT Lowest Velocity 0.5 cm/s


Category Item i900/i800/i700 V5.1

Highest Velocity 177.1 cm/s

PLI-2004BX Lowest Velocity 0.3 cm/s


Highest Velocity 119.6 cm/s

PLI-3003BX Lowest Velocity 0.2 cm/s


Highest Velocity 104.6 cm/s

PLI-30VX Lowest Velocity 8.7 cm/s


Highest Velocity 82.9 cm/s

(i600 does not support PLI-2004BX, 475BX, 1205BX, 30VX)


CDI gain range 0 - 40 dB, 0.5 dB step

M/D M/D mode sweep speed 2.381 - 19.05 sec / full screen, 8 steps (NTSC)
2.381 - 19.05 sec / full screen, 8 steps (PAL)

Minimum detectable velocity for PWD/CWD


PWD/CWD PWD 0.01 cm/s (PLI-3003BX)
0.02 cm/s (PLI-2004BX)
0.03 cm/s (PLT-1204BT)
CWD 2.3 cm/s (PSI-70BT)

(i600 does not support PLI-2004BX)


Maximum detectable velocity for PWD/CWD PWD: 1746 cm/s (PST-28BT)
CWD: 2205.7cm/s (PST-28BT)

In Duplex mode 2038cm/s (PVT-375BT)

1018.5cm/s (PLT-705BT)

In Triplex mode 2038cm/s (PVT-375BT)


1018.5cm/s (PLT-705BT)

667.0cm/s (PLT-1204BT)
342.8.0cm/s (PLI-2004BX)
(i600 does not support PLI-2004BX)
Sample gate size for PWD 0.3-20 mm, 15 steps

Doppler filter PW 2 - 9921 Hz (PST-50BT)


CW 153 - 13021 Hz (PST-50BT)
Doppler gain range PWD; 0 - 50 dB, 1 dB step
CWD; 0 - 50 dB, 1 dB step

SMI velocity range for each transducer


PVI-475BT
Lowest Velocity 0.2 cm/s
Highest Velocity 10.0 cm/s

PVI-475BX
Lowest Velocity 0.2 cm/s
Highest Velocity 10.0 cm/s

PLI-1205BX
Lowest Velocity 0.3 cm/s
Highest Velocity 11.2 cm/s

PLT-1204BT
Lowest Velocity 0.3 cm/s
Highest Velocity 9.3 cm/s

PLI-2004BX
Lowest Velocity 0.1 cm/s
Highest Velocity 4.3 cm/s

PLI-3003X
Lowest Velocity 0.1 cm/s
Highest Velocity 10.6 cm/s

(i600 does not support PLI-2004BX, 475BX, 1205BX)


Category Item i900/i800/i700 V5.1

Maximum volume rate of 4D transducers PVT-675MVL: 35 vps


4D (volume/sec) PVT-681MVL: 42 vps
PSI-30VX : 160 vps
PEI-512VX :103 vps
(i600 does not support PSI-30VX)
Sweep range of 4D transducers PVT-675MVL: min. 10 deg - max: 90 deg
PVT-681MVL: min. 10 deg - max: 150 deg
PSI-30VX : min. 60 deg - max: 120 deg
(i600 does not support PSI-30VX)
Configuration Ratio of Packing Material for CMSE
Other Aplio i900 25.0Kg (wood: 40%, paper: 59%, other: 1%)
Aplio i800 25.0Kg (wood: 40%, paper: 59%, other: 1%)
Aplio i700 25.0Kg (wood: 40%, paper: 59%, other: 1%)
Aplio i600 25.0Kg (wood: 40%, paper: 59%, other: 1%)
*Material is categorized by wood, paper, metal, plastic and other.

Product Recycling Ratio Aplio i900 68,0%


Aplio i800 68,0%
Aplio i700 68,0%
Aplio i600 72,7%
*Plastic is not included in the above recycling ratio.
WideView Feature: WideView with i-Beam

Benefit: A longer length of a vessel can be


observed in one plane.
Enables wide, deep and homogeneous depicting
with high image quality
35 º 35 º
Enables wider range of liver scanning, scanning
both kidneys, long tract such as blood vessels and
gastro-intestine and measuring bladder or spleen
in one view.

PVl-475BX

Internal Use Only 1


UPS
POWERTECH
UPS EN LÍNEA

POWERTECH
TX9
El sistema de potencia ininterrumpida (UPS)
Powertech TX9 1kVA / 1.5K kVA / 2kVA / 3kVA modelo TX9 de Powertech, es un sistema altamente
confiable, con tecnología de doble conversión
en línea, que garantiza una onda senoidal pura,
ideal para equipo de misión crítica (redes,
telecomunicaciones, servidores, y aplicaciones
industriales), con certificación UL Listed / UL 1778.

Factor de potencia de salida de


0.9
El modelo TX9 es un UPS de alta densidad, con un
factor de potencia de salida de 0.9, que permite
mayor rendimiento y más eficiencia, perfecto para
aplicaciones críticas.

Modo convertidor de frecuencia


50/60HZ
La salida del UPS se configura a 50 ó 60HZ, para
alimentar los equipos sensitivos.
Pantalla LCD amigable con el
usuario
La pantalla LCD situada en el panel frontal ofrece
navegación simple y puede girar para una posición
vertical u horizontal, según desee el usuario.

Powertech TX9 6kVA / 10kVA


Tecnología DSP para modelos de Apagado de emergencia (EPO)
6KVA o más Esta característica permite el apagado del equipo en
El controlador DSP proporciona una solución caso de un incendio u otra emergencia.
mejorada de alto desempeño.
Diseño ideal para rack o torre
Diseño de baterías Hot-swappable El UPS TX9 puede instalarse como una torre sobre
bases, o en un soporte de rack de 19 pulgadas.
para modelos de 1 a 3KVA

Este diseño posibilita el cambio de baterías del UPS,


sin necesidad de interrumpir la operación del
equipo protegido.

19” r----------------in Programmable Outlets (P1) Floor-standing Tower


connect to non-critical devices

Manejo programable de las salidas Paralelo redundante N+X para


El usuario puede, fácilmente, controlar segmentos
de la salida; esto permite que durante un fallo
modelos de 6 y 10KVA
El modelo Powertech TX9 puede configurarse en
eléctrico se extienda el tiempo de respaldo en
paralelo con un máximo de 3 unidades; así se
baterías para los equipos más críticos, al apagar
aumenta en potencia, seguridad y disponibilidad.
otros dispositivos.

3
UPS EN LÍNEA

POWERTECH TX9 INFORMACIÓN DE BATERÍAS


Capacidad 1 kVA 1.5 kVA 2 kVA 3 kVA

Tipo de Batería 12 V/9Ah 12 V/9Ah 12 V/9Ah 12 V/9Ah

Número de batería 4 pcs 6 pcs 8 pcs 12 pcs

Dimensión
(DxWxH) 380 x 438 x88 480 x 438 x88 600 x 438 x88

Peso (Kg) 20.6 29.1 31.1 43.3

ESPECIFICACIONES TÉCNICAS
POWERTECH TX9
T X9 1 kVA TX9 1.5 kVA TX9 2 kVA TX9 3 kVA
Fases Monofásico con tierra (fase, neutro, tierra)

VA 1000 1500 2000 3000


Capacidad
W 900 1350 1800 2700
A 7.5 11.25 15 22.5

ENTRADA
Voltaje 80VAC / 70VAC / 60VAC / 55VAC ± 5%
transferencia baja 5% (basado en el porcentaje de carga)100%-80% / 80%-70% / 70%-60% / 60%-0)
Voltaje de regreso 85VAC / 75VAC / 65VAC / 60VAC ± 5%
bajo 5% (basado en el porcentaje de carga) 100%-80% / 80%-70% / 70%-60% / 60%-0)
Rango de voltaje
Voltaje de 150 VAC ± 5%
transferencia alto
Voltaje de regreso
alto 140 VAC ± 5%

Rango de frecuencia 40 Hz-70Hz

Factor de potencia 0.99@Voltaje Nominal (100% de Carga)

SALIDA
Voltaje de salida 110/115/120/127 VAC
Regulación de voltaje AC (Modo Batería) (±1)%

Rango de frecuencia (Rango sincronizado) 47-53 Hz o 57-63 Hz

Rango de frecuencia (Modo Batería) 50Hz ±0.2 Hz

Relación de corriente de cresta 5:1 (Max)

Distorsión armónica 2% THD (Carga lineal) 8% THD (Carga no-lineal)


T X9 1 kVA TX9 1.5 kVA TX9 2 kVA TX9 3 kVA

Modo en línea a Cero


Tiempo de modo en batería
transferencia De inversor a
modo "Bypass" 4 ms (Estimado)

Forma de onda (Modo en batería) Pura sinusoidal

EFICIENCIA
Modo AC 86% típico, 88% a pico 88% típico, 90% a pico

Modo Emergencia 83% típico, 88% a pico 85% típico, 88% a pico

BATERÍA
Tipo de batería / Autonomía 12V/9AH / 10 min aprox

Cantidad 2 3 4 6

Tiempo de respaldo aproximado 10 min 10 min 10 min 10 min

Corriente de carga (Max) 1.0 A 1.0 A 1.0 A 1.0 A

Voltaje de carga 27.4 VDC ± 1% 41.1 VDC ± 1% 54.7 VDC ± 1% 82.1 VDC ± 1%

INDICADORES
Pantalla LCD Nivel de carga, nivel de falla o alarma

ALARMA
Modo batería Emite sonido cada 4 segundos

Nivel bajo de batería Emite sonido cada segundo

Sobrecarga Emite sonido dos veces cada por segundo

Falla Emite sonido contínuo

CARACTERÍSTICAS FÍSICAS
Dimensiones DxWxH (mm) 380 x 438 x 88 (2U) 480 x 438 x 88 (2U) 380 x 438 x 88 (2U) 600 x 438 x 88 (2U)

Conectores entrada Nema 5-15P Nema 5-15P Nema 5-20P L5- 30P

Conectores salida Nema 5-15R Nema 5-15R Nema 5-15R L5-30R / Nema 5-15R
Número de
Receptáculos 8 protegidos por UPS y contra sobretensiones

Amperaje/Tipo 15 A/polarizado 15 A/polarizado 20 A/polarizado 30 A/polarizado

Peso Neto (Kgs) 12.9 17.6 20.6 28

CONDICIONES AMBIENTALES
Humedad 20-90 %RH @ 0-40°C (Sin condensación)

Nivel de ruido Menos de 50dBA @ 1 metro

GESTIÓN
Smart RS - 232/USB Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and Mac

Tarjeta SNMP opcional Monitoreo por tarjeta SNPM y buscador "web"

5
Powertech TX 1 kVA a 230VAC

9
Powertech TX9 6-10KVA a 230VAC

7
11

You might also like