Installation Data Sheet

Series: 1:1 Belt Drive AS.3 SFC


Document No.: TI-DATA-2014-SFC 18S 22S
Version: 1.4
Revision Date: 09/11/15
Model SFC 18S SFC 22S
Rated Pressure [psig] 110 125 145 160 190 217 110 125 145 160 190 217
I. COOLING DATA
Cooling System Available [Std., Opt.] A/C A/C
Standard Ambient Temp. Range [°F] 40 - 115 40 - 115
VENTILATION OF COMPRESSOR ROOM
Air Inlet Opening [sq. ft.] (A/C) Z 6.5 7.5
Solution A (forced ventilation with exhaust fan) as shown in service manual
Cooling Fan Capacity [CFM] (A/C) 2,354 2,943
Solution B (exhaust air used for space heating) as shown in service manual
Internal Cooling Fan Capacity [CFM] (A/C) 1,940 2,530
Max. Additional Pressure Drop for Ducts [inch Water Column], (A/C) 1/4 1/6
Exhaust Air Opening Reference Dimensions See drawing for actual dimensions. The actual individual duct dimension will vary for every
installation based on actual length, number and type of bends, accessories etc.
25 1/2 x 20 25 1/2 x 20
(L x W) [in]

Recommended machine placement


Model shown for reference only and dimensions inches
Actual Duct size may vary with installation
L Left side clearance = 8

A A Exhaust Fan________ R Right side clearance = 40

B Exhaust Air Duct F Front clearance = 40

Z Inlet Air Opening BK Back clearance = 40

H Height clearance = 140

AIR COOLED DATA


Internal Cooling Fan Capacity [CFM] 1,940 2,530
Approach Temp. [°F] Reference conditions: 14.5 psia, 30% relative humidity and 68°F inlet air temperature. 12.6 10.8 9 14.4 12.6 10.8
Typical Heat Rejected [BTU / HR] 78,200 93,600
Fan Motor [HP], oilcooler/aircooler 0.74 0.74

Confidential
Copyright 2015, Kaeser Compressors, Inc. Specifications are subject to change without notice. 1 of 2
Installation Data Sheet
Series: 1:1 Belt Drive AS.3 SFC
Document No.: TI-DATA-2014-SFC 18S 22S
Version: 1.4
Revision Date: 09/11/15
Model SFC 18S SFC 22S
Rated Pressure [psig] 110 125 145 160 190 217 110 125 145 160 190 217
Electrical data may vary in accordance with motor manufacturer's specifications. Motors are EISA
II. ELECTRICAL DATA compliant.

Drive Motor
Motor HP 25 30
NEMA Nominal Efficiency % 91.7% 91.7%
Service Factor 1.24 1.22
Enclosure Type TEFC/IP 55 TEFC/IP 55
Insulation Class F F
Standard Voltage 460V/3ph/60Hz 460V/3ph/60Hz
Full Load Amps [FLA] @ 460V/3ph/60 Hz/YD 29.5 33.5
FAN MOTOR (A/C)
Enclosure Type TEFC/IP 55 TEFC/IP 55
Insulation Class F F
Fan Motor [HP], oilcooler | aircooler 0.74 0.74
Nominal Efficiency %, oilcooler | aircooler 76.5% 76.5%
Full Load Amps [FLA] @ 460V/3ph/60 Hz/YD, oilcooler 1.62 1.62
TOTAL PACKAGE DATA (A/C)
Do NOT operate package on any unsymmetrical power supply. Also do NOT operate package on power supplies like, for example, a three-phase star three-phase star
three-phase (open) delta or three-phase start with non-grounded neutral. The machine requires a symmetrical three-phase power (wye); 4-wire; (wye); 3-wire;
supply transformer with a WYE configuration output as shown on the right. In a symmetrical three-phase supply the phase angles and grounded neutral grounded neutral
voltages are all the same. Other power supplies are not suitable.
Continuous Duty (Hours per day) 24 24
Control Cabinet Class [NEMA] 12 12
Short Circuit Current Rating (SCCR) [kA] @ 460V/3ph/60 Hz/YD 50 50
Package Full Load Amps @ 460V/3ph/60 Hz/YD (A/C) 45 45
Recommended Disconnect Fuse Size [Amps] @ Dual-element time-delay fuse; based on 2011 NEC 240.6, 430.52, and Tables 430.52, 430.148,and
430.150.4.
70 70
460V/3ph/60Hz/YD (A/C)
Based on 2011 NEC 110.14(C), 220.3, 310.15, Table 310.16, 430.6, 430.22, 430.24 and Tables
Recommended Disconnect Wire Size [AWG/kcmil] @ 430.148 and 430.150. Use multi-strand copper core wire. Size calculated based on 40 oC ambient
3 AWG per phase and ground 3 AWG per phase and ground
460V/3ph/60Hz/YD (A/C) temperature, with 60°C insulation rated wire if package FLA x 1.25 is less than 100A or 75°C
temperature rated wire for 100A and larger.

INSTALLATION and MAINTENANCE DATA


A/C with Super Soundproofing [dB(A)] SOUND PRESSURE LEVEL [Measured in dB(A) according to ISO 2151 using ISO 9614-2] 70 72
A/C Air Discharge [inches NPT] 1 1/4 1 1/4
Power Input Conduit Opening(s) [inches] 2 1/4 2 1/4
Condensate Drain Connection [NPT] N/A N/A
Width [inches] 31 1/2 31 1/2
Depth [inches] 43 1/2 43 1/2
Height [inches] 60 1/4 60 1/4
Floor Space [sq. ft.] 9.6 9.6
Weight (A/C)[lb] 1,169 1,213
Weight may vary based on airend selected.
Estimated Shipping Weight [lb] CF CF
COMPRESSOR FLUID DATA
Fluid Capacity (A/C) [gal] 2.9 2.9
Flow Rate [gal/min] 9 9
Standard Fluid Type Sigma M-460 Sigma M-460
MAINTENANCE PARTS
Air Inlet Filter 6.4163.0
Filter Mat (optional) 5.6143.0
Filter Mat for Control Cabinet 6.3572.0
Fluid Filter 6.3463.0
Fluid Separator Kit 6.3789.0
Maintenance Kit for Optional 5-year warranty ANAKASK3SFC
Maintenance Kit for Optional 5-year warranty, with food-grade lubricant ANAKASK3SFCS

Confidential
Copyright 2015, Kaeser Compressors, Inc. Specifications are subject to change without notice. 2 of 2