Flat Slab Design (by Direct Design Method) - COLUMN STRIP

GRID - A TO E
Material : Load :
Concrete Grade M 25 Slab thickness 250 mm
Reinforcement Grade Fe 500 Thickness of Drop 0 mm
Floor Finish Load 3 kN/m2
Span: Total Dead Load 9.25 kN/m2
End Span 7.2 m Live Load 5 kN/m2
Middle Span 6.4 m
Effective Cover: 25 mm
Column size, Length 0.3 m
Width 0.9 m Eff Depth of Slab 225 mm

Clear Span, Ln 6.9 m Stiffness Calculations

Column strip 1.6 m Column Height, H1 4.45 m


Middle strip 3.2 m H2 4.45 m

DL/LL 1.850 OK Clear Height, 4.20 m


4.20 m
Total Design Load 14.25 kN/m2 Effective Height, 3.57 m
Design Load, W 629.3 kN 3.57 m
αc = Kc/Ks 6.970
Absolute Moment, M0 814.1 kNm 1+1/αc 1.14

Moments in End Span Moments in Interior Span

Interior Negative Design Moment 539.40 kNm Negative Design Moment 529.19 kNm
Interior Positive Design Moment 313.55 kNm Positive Design Moment 284.95 kNm
Exterior Negative Design Moment 462.79 kNm

Column Strip Design Middle Strip Design

At Exterior Support of End Span At Middle of End Span


Negative Moment 462.79 Posiative Moment 125.42
Reinforcement Required 1750.83 mm2/m Reinforcement Required 416.03 mm2/m
Provide Dia c/c Provide Dia c/c
Alth 10 200 Alth 10 200
Ext 20 200 Ext 0 180
Reinforcement Provided 1963.50 mm2/m Reinforcement Provided 392.70 mm2/m
633.33 OK 150.49 NOT OK
At Middle of End Span At First Interior Support
Posiative Moment 21.95 Negative Moment 134.85
Reinforcement Required 70.56 mm2/m Reinforcement Required 448.66 mm2/m
Provide Dia c/c Provide Dia c/c
Alth 10 200 Alth 10 200
Ext 12 200 Ext 0 180
Reinforcement Provided 958.19 mm2/m Reinforcement Provided 392.70 mm2/m
25.52 OK 162.29 NOT OK
At First Interior Support At Middle of Interior Span
Negative Moment 67.42 Posiative Moment 113.98
Reinforcement Required 219.67 mm2/m Reinforcement Required 376.71 mm2/m
Provide Dia c/c Provide Dia c/c
Alth 10 200 Alth 10 200
Ext 16 200 Ext 0 180
Reinforcement Provided 1398.01 mm2/m Reinforcement Provided 392.70 mm2/m
79.46 OK 136.27 OK
At Middle of Interior Span At Other Interior Support
Posiative Moment 7.12 Negative Moment 132.30
Reinforcement Required 22.80 mm2/m Reinforcement Required 439.81 mm2/m
Provide Dia c/c Provide Dia c/c
Alth 10 200 Alth 10 200
Ext 0 180 Ext 0 180
Reinforcement Provided 392.70 mm2/m Reinforcement Provided 392.70 mm2/m
8.25 OK 159.09 NOT OK
At Other Interior Support Minimum Reinforcement 270 mm2/m
Negative Moment 52.92 Provide Dia c/c
Reinforcement Required 73.32 mm2/m Alth 10 200 at Top
Provide Dia c/c Reinforcement Provided 392.70 mm2/m
Alth 12 150 OK
Ext 12 150 Alth 10 200 at Bottom
Reinforcement Provided 1507.96 mm2/m Reinforcement Provided 392.70 mm2/m
26.52 OK 142.05 OK