SMART PRESSURE TRANSMITTER

APC-2000ALM
with MODBUS RTU protocol
ü Galvanic isolation of power supply and communication bus
ü Accuracy 0.075%
ü Aluminum or stainless steel housing with local display
ü Explosion proof certificate ATEX and IECEx

APC-2000ALM - Aluminum epoxy painted casing


APC-2000ALM/SS - Stainless steel casing 133
18 132 18 Rating plate

91.5
M20×1.5 packing gland
Æ5…10 cable
or 1/2 NPT F

40
Two holes (M6)
30.5

Lock preventing
the casing
rotation

SW27 SW27 SW27 SW27


8

2 8
8

70
19

15
320

G1/4’’ Æ12
Æ4 1/2’’NPT Æ25
Æ25

G1/2 type 1/2’’NPT M type GP type 1/2’’NPT F type GP type


G1/2", Æ4 hole 1/2’’NPT male + G1/2", Æ12 hole internal thread P type
M type internal thread G1/4’’ P type 1/2-14NPT 1/2"NPT M type
M20×1.5, Æ4 hole M20×1.5, Æ12 hole for HS version

SW41
SW27 SW27 SW27
12.5
3

16.2
20.5

20.5

O-ring
10

O-ring
10

15×2
26 × 2 Æ15
Æ30 Æ18
G1/2B
G1/2B
for P≤350bar for P>350bar

CG1 type CG1/2 type Version with direct or remote


G1" with flush diaphragm G1/2" with flush diaphragm diaphragm seal
Diaphragm seal data -
see chapter III

I/ 7
Application
Pressure transmitter APC-2000ALM is designed to measure pressure, vacuum and absolute pressure of gases, vapors and
liquids. The measuring element is a piezoresistive silicon sensor separated from the medium by an isolating diaphragm and
manometer liquid. The electrical signal from the sensor is converted into a digital value compatible with the Modbus RTU
protocol. The housing is made of high-pressure cast aluminum alloy or acid-resistant steel with IP66 protection.
The transmitter is equipped with a configurable liquid crystal display. The housing design allows the display to be rotated 90°,
180° and 270°, the housing can be rotated relative to the sensor in the range of 0 - 340°, and the cable insertion direction can be
selected. The display panel includes buttons for scaling the display and selecting the unit of pressure to be measured.

Installation
The transmitter can be mounted directly on the object. To measure the pressure of steam or other hot media, use a siphon or impulse
tube. The use of a pressure gauge valve in front of the transducer simplifies installation, and makes it possible to zero or replace the
transducer while the facility is in operation. A universal bracket (AL bracket) is provided for mounting the transmitter.

Operation modes of the transmitter


- Configuration - is used to set the transmitter's transmission parameters and network address, as well as to reset, calibrate and
restore the transmitter's factory settings. The transmitter is operated via a PC using an RS-485/USB converter and Modbus
Configurator software.
- Modbus RTU - the transmitter operates in a four-wire system with RS485 transmission with Modbus RTU protocol.
Measuring ranges
No Nominal measuring range Overpressure limit
. (FSO) (without hysteresis)***
1 0…1000 bar (0…100 MPa) 1200 bar (120 MPa)
2 0…600 bar (0…60 MPa) 1000 bar (100 MPa)
3 0…300 bar (0…30 MPa) 450 bar (45 MPa)
4 0…160 bar (0…16 MPa) 450 bar (45 MPa)
5 0...70 bar (0...7 MPa) 140 bar (14 MPa)
6 -1...70 bar (-0,1...7 MPa) 140 bar (14 MPa)
7 0...25 bar (0...2,5 MPa) 50 bar (5 MPa)
8 -1...25 bar (-0,1...2,5 MPa) 50 bar (5 MPa)
9 0...7 bar (0...0,7 MPa) 14 bar (1,4 MPa)
10 -1…7 bar (-100…700 kPa) 14 bar (1,4 MPa)
11 -1…1,5 bar (-100…150 kPa) 4 bar (400 kPa)
12 0...2 bar (0...200 kPa) 4 bar (400 kPa)
13 0...1 bar (0...100 kPa) 2 bar (200 kPa)
14 -0,5...0,5 bar (-50...50 kPa) 2 bar (200 kPa)
15 0...0,25 bar (0...25 kPa) 1 bar (100 kPa)
16 -100...100 mbar (-10...10 kPa) 1 bar (100 kPa)
17 -15...70 mbar (-1,5...7 kPa) 0,5 bar (50 kPa)
18 0...1,3 bar abs (0...130 kPa abs) 2 bar (200 kPa)
19 0...7 bar abs (0...0,7 MPa abs) 14 bar (1,4 MPa)
20 0...25 bar abs (0...2,5 MPa abs) 50 bar (5 MPa)
21 0...70 bar abs (0...7 MPa abs) 140 bar (14 MPa)
22 0...300 bar abs (0...30 MPa abs) 450 bar (45 MPa)

Technical data
Metrological parameters
Accuracy £ ±0,075% Electrical parameters
£ ±0,1% for range no. 18
Power supply 12...30 V DC
Long-term stability £ accuracy for 3 years
Current consumption < 80 mA
or £ 2 × accuracy for 5 years
Output MODBUS RTU
Thermal error < ±0,05% (FSO) / 10°C
(0,1% for ranges no. 16, 17, 18) Resolution 0,0007% of measuring range
max ±0,25% (FSO) in the whole compensation range
Transmission range 1200m
(0,4% for ranges no. 16, 17, 18)
Thermal compensation range -25...80°C Address space 1…247 devices address
Error due to supply voltage change 0,002% (FSO) / V Transmission speed 1200, 2400, 4800, 9600, 19200,
28800, 38400, 57600, 115200 bps
Materials Transmission parity check no parity, odd, even
Wetted parts and diaphragm 316Lss Transmission frame 11 bit (8N2, 8E1, 8O1)
Casing Aluminium or 316ss 10 bit (8N1)
Ingres protection IP66
Response time to inquiry 3...20 ms
Operating conditions Factory settings for transmission parameters:
Operating temperature range (ambient temp.) -40…85°C Transmission speed 9600 bps
Exd -40…75°C Parity check even
Address 1
Medium temperature range -40...120°C
over 120°C – measurement with use
an impulse line or diaphragm seal
CAUTION: the medium must not be allowed to freeze in the im-
pulse line or close to the process connection of the transmitter

I/ 8
Ordering procedure
Model Code Description
APC-2000 Smart pressure transmitter
Versions /ALM……………........………………………………..… With display, Modbus output
/SS………………………………………………... Stainless steel housing
/Exd………………………………………………. II 1/2G Ex ia/db IIC T5/T4 Ga/Gb
II 2D Ex ia tb IIIC T100°C Db
Certificates, options* I M2 Ex db ia I Mb (version with SS housing) Packing gland available on
Ex ia/db IIC T5/T4 Ga/Gb request
IECEx Ex ia tb IIIC T100°C Db
Ex db ia I Mb (version with SS housing)
/Tlen…………..............…….....………......……. For oxygen service (sensor filled with Fluorolube fluid), only G1/2” connection
* more than one option
is available
/-40…80°C….............…................................... Extended thermal compensation range -40 ÷ 80°C
/IP67……....….............….................................. Protection class IP67
/NACE……………………………………………. NACE MR-01-75 certificate (process connections: M, G1/2”, P, GP and 1/2”NPTM)
Range Min. set range
/0÷1000 bar......................................…. 0÷1000 bar (0÷100 MPa) 10 bar (1 MPa)
/0÷600 bar......................................…… 0÷600 bar (0÷60 MPa) 6 bar (600 kPa)
/0÷300 bar…......................................... 0÷300 bar (0÷30 MPa) 3 bar (300 kPa)
/0÷160 bar..................................…..….. 0÷160 bar (0÷16 MPa) 1,6 bar (160 kPa)
/0÷70 bar…........................................... 0÷70 bar (0÷7 MPa) 0,7 bar (70 kPa)
/-1÷70 bar….......................................... -1÷70 bar (-0,1÷7 MPa) 0,71 bar (71 kPa)
/0÷25 bar…...................................……. 0÷25 bar (0÷2,5 MPa) 0,25 bar (25 kPa)
/-1÷25 bar…..................................……. -1÷25 bar (-0,1÷2,5 MPa) 0,26 bar (26 kPa)
/0÷7 bar…...................................……… 0÷7 bar (0÷700 kPa) 0,07 bar (7 kPa)
/-1÷7 bar................................................ -1÷7 bar (-100÷700 kPa) 0,07 bar (7 kPa)
Nominal measuring range /-1÷1,5 bar............................................. -1÷1,5 bar (-100÷150 kPa) 120 mbar (12 kPa)
/0÷2 bar…….......................................... 0÷2 bar (0÷200 kPa) 100 mbar (10 kPa)
/0÷1 bar……...................................…… 0÷1 bar (0÷100 kPa) 50 mbar (5 kPa)
/-0,5÷0,5 bar.......................................... -0,5÷0,5 bar (-50÷50k Pa) 50 mbar (5 kPa)
/0÷0,25 bar…........................................ 0÷0,25 bar (0÷25 kPa) 25 mbar (2,5 kPa)
/-100÷100 mbar..................................... -100÷100 mbar (-10÷10 kPa) 20 mbar (2 kPa)
/-15÷70 mbar…..................................... -15÷70 mbar (-1,5÷7 kPa) 5 mbar (0,5 kPa)
/0÷1,3 bar ABS...................................... 0÷1,3 bar ABS (0÷130 kPa ABS) 0,1 bar ABS (10 kPa ABS)
/0÷7 bar ABS..................................…... 0÷7 bar ABS (0÷700 kPa ABS) 0,1 bar ABS (10 kPa ABS)
0,25 bar ABS
/0÷25 bar ABS....................................... 0÷25 bar ABS (0÷2,5 MPa ABS)
(25 kPa ABS)
/0÷70 bar ABS....................................... 0÷70 bar ABS (0÷7 MPa ABS) 0,7 bar ABS (70 kPa ABS)
/0÷300 bar ABS..................................... 0÷300 bar ABS (0÷30 MPa ABS) 0,3 bar ABS (30 kPa ABS)
/M…....................................... Thread M20x1,5 (male) with Æ4 hole, wetted parts SS316L
/G1/2….................................. Thread G1/2’’ (male) with Æ4 hole, wetted parts SS316L
/G1/2(Au)…........................... Thread G1/2’’ (male) with Æ4 hole, gold plated diaphragm (range no. 1, 2, 3, 4, 5)
/P…........................................ Thread M20x1,5 (male) with Æ12 hole, wetted parts SS316L Not available
/GP…..................................... Thread G1/2’’ (male) with Æ12 hole, wetted parts SS316L with range
/GP(Hastelloy)….................... Thread G1/2’’ (male) with Æ12 hole, wetted parts Hastelloy C 276 no. 1, 2
/CG1”…................................. Thread G1’’ with flush diaphragm, wetted parts SS316L
(Pressure limits: min. 0,1bar / max. 70bar)
Process connections /CG1”(Hastelloy)…………….. Thread G1’’ with flush diaphragm, wetted parts Hastelloy C 276
(Pressure limits: min. 0,1bar / max. 70bar)
/CG1/2”….............................. Thread G1/2’’ with flush diaphragm, wetted parts SS316L
(Pressure limits: min. 2,5bar)
/1/2”NPTM….......................... Thread 1/2’’NPT Male, G1/4” Female, wetted parts SS316L
(Pressure limits: 1/2”NPT Male max. 690bar, G1/4” Female max. 1000bar)
/1/2”NPTM(Hastelloy)............ Thread 1/2’’NPT Male, G1/4” Female, wetted parts Hastelloy C 276
(Only nominal range 0…300bar)
/1/2”NPTF….......................... Thread G1/2” or M20x1,5 with adapter to 1/2”NPT Female, wetted parts SS316L
(Pressure limits: max. 690bar)
/code of diaphragm seal……. Diaphragm seal (see chapter of diaphragm seals)
(without marking) Packing gland M20x1,5
Electrical connection
/US................................. Thread 1/2”NPT Female
/AL.................... Mounting bracket type AL for 2” pipe, material zinced steel
/AL(SS)............. Mounting bracket type AL for 2” pipe, material ss304
Accessories /AL(SS316)....... Mounting bracket type AL for 2” pipe, material ss316
/ST.................... Stainless Steel plate fixed to the housing
/MT................... Stainless Steel Tag plate mounted on wire