Project K
Project K
Automation Portal
Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant
Network 1:
%M0.2
%M0.0 "started"
"Start" SR
S Q
%M0.1
"Stop"
R1
Network 2:
%DB2
"counter_step"
CTU
"step1".Q Int
N CU Q
%M0.7 CV ...
"step1_finished"
"step2".Q
N
%M1.4
"Step2_Finished"
"step3".Q
N R
%M2.1 3 PV
"step3_Finished"
Network 3:
%DB1
"step1"
%M0.3
%M0.2 TP "Step1_East_
"counter_step".CV Time "step1".ET Green"
"started"
== <
Int IN Q Time
T#20S PT ET ...
0 T#15S
%M0.4
"Step1_West_
Red"
%M0.5
"Step1_North_
Red"
%M0.6
"step1_East_
"step1".ET "step1".ET Yellow"
> <
Time Time
T#15S T#20S
Network 4:
Totally Integrated
Automation Portal
%DB3
"step2"
%M1.0
%M0.2 TP "Step2_West_
"counter_step".CV Time "step2".ET Green"
"started"
== <
Int IN Q Time
1 T#20S PT ET ... T#15S
%M1.2
"Step2_North_
Red"
%M1.1
"Step2_East_Red"
%M1.3
"Step2_West_
"step2".ET "step2".ET Yellow"
> <
Time Time
T#15S T#20S
Network 5:
%DB4
"step3"
%M1.5
%M0.2 TP "step3_North_
"counter_step".CV Time "step3".ET Green"
"started"
== <
Int IN Q Time
2 T#20S PT ET ... T#15S
%M1.6
"step3_East_Red"
%M1.7
"step3_West_Red"
%M2.0
"step3_North_
"step3".ET "step3".ET Yellow"
> <
Time Time
T#15S T#20S
Network 6: East
%M0.3
"Step1_East_ %M2.2
Green" "East_Green"
%M1.1 %M2.4
"Step2_East_Red" "East_Red"
%M1.6
"step3_East_Red"
%M0.6
"step1_East_ %M2.3
Yellow" "East_Yellow"
Network 7: West
%M1.0
"Step2_West_ %M3.1
Green" "West_Green"
%M0.4
"Step1_West_ %M3.0
Red" "West_Red"
%M1.7
"step3_West_Red"
%M1.3
"Step2_West_ %M3.2
Yellow" "West_Yellow"
Totally Integrated
Automation Portal
Network 8: North
%M1.5
"step3_North_ %M2.7
Green" "North_Green"
%M1.2
"Step2_North_ %M2.5
Red" "North_Red"
%M0.5
"Step1_North_
Red"
%M2.0
"step3_North_ %M2.6
Yellow" "North_Yellow"