Modular DIN Rail Products

MCBO
DZ47LE Residual Current Operated
Circuit Breaker with over-current A
protection (Electronic)
1. General
1.1 Application
Personnel and fire protection
Cable and line protection against overload and short-circuits
1.2 General rules for choosing RCBO:
a.Rated residual operating current
I∆n ≤ 30 mA: additional protection in the case of direct
contact I∆n ≤300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class
AC class – Tripping is ensured for sinusoidal, alternating
currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits
against overloads and short-circuits; protection for resistive and
inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits
against overloads and short-circuits; protection for circuits which
supply loads with high inrush current at the circuit closing (LV/LV
transformers, breakdown lamps).
1.3 Detailed certificates information,please refer to Certificates
Table on P(A-138).

2. Technical Features
2.1 Curves
C curve D curve

t(s) t(s)
10000 10000
5000 5000
1Ir 1Ir
2000 2000
1000 1000
500 500
200 200
100 100
50 50
20 20
10 10
5 5
2 2
1 1
0.5 0.5
0.2 0.2
0.1 0.1
0.05 0.05
0.02 0.02
0.01 0.01
0.005 0.005
0.002 0.002
0.001 0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In

> >> A-42


Modular DIN Rail Products
MCBO
2.2

Standard IEC/EN 60898-1


Type (wave form of the earth leakage sensed) AC
Thermo-magnetic release characteristic C, D
Rated current In A 6, 10, 16, 20, 25, 32, 40, 50, 60
Rated voltage Ue V 230/400
Rated sensitivity I△n A 0.03, 0.1, 0.3

Electrical Rated residual making


A 500
features and breaking capacity I△m
Rated short-circuit capacity lcn A 4,500/6,000
Break time under I△n s ≤0.1
Rated frequency Hz 50/60

Rated impulse
V 4,000
withstand voltage (1.2/50)Uimp
Dielectric TEST voltage at ind. Freq. for 1min kV 2
Insulation voltage Ui 500
Pollution degree 2
Electrical life 2,000
Mechanical life 2,000
Mechanical Contact position indicator Yes
features
Protection degree IP20
Ambient temperature -5...+40 (Special application please refer to P72

(with daily average≤35℃) for temperature compensation correction)

Storage temperature ℃ -25...+70


Terminal connection type Cable/U-type busbar/Pin-type busbar

mm 2 25
Terminal size top/bottom for cable
AWG 18-3

mm 2 25
Installation Terminal size top/bottom for busbar
AWG 18-3

N*m 2
Tightening torque
In-Ibs. 18
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top

2.3 Temperature derating


Please refer to table below for temperature compensation correction.

Temperature -15℃ -5℃ 0℃ 10℃ 20℃ 30℃ 40℃ 55℃


Temperature compensation
coefficient 1.19 1.15 1.13 1.06 1.05 1.00 0.96 0.89

A-43 > >>


Modular DIN Rail Products
MCBO
3. Overall and Mounting Dimensions (mm)
In=6~32A
Overall and Mounting Dimensions
A

H
L L
42.5±0.31

45±0.31
35±0.50

94.5 -1.40

94.5 -1.40
0

0
B B

Number of poles L (mm) H (mm) B (mm)


0 0 0
1P+N 45 -0.62 74 -1.20 27 -0.52
0 0 0
2P 63 -0.74 77.8 -1.20 27 -0.52
0 0 0
3P 90 -1.40 77.8 -1.20 36 -0.62
0 0 0
3P+N 99 -1.40 77.8 -1.20 45 -1.00
0 0 0
4P 117 -1.40 77.8 -1.20 45 -1.00

In=40~60A
Overall and Mounting Dimensions

H
42.5±0.31 L L
45±0.31
35±0.50

94.5 -1.40

94.5 -1.40
0

B
B

Number of poles L (mm) H (mm) B (mm)


0 0 0
1P+N 54 -0.74 74 -1.20 36 -0.62
0 0 0
2P 72 -0.74 77.8 -1.20 36 -0.62
0 0 0
3P 103.5 -1.40 77.8 -1.20 49.5 -0.62
0 0 0
3P+N 117 -1.40 77.8 -1.20 63 -1.20
0 0 0
4P 135 -1.60 77.8 -1.20 63 -1.20