Pump Performance Datasheet

Company Name Model/Order No. FST-11FLC Enclosed Impeller (STD


Company contact number Model)
Quote Number 1234107 Stages 11
Project name Default Quantity of pumps in parallel 1
Based on curve number 11FLC(4POLE)
Saved Date 02 Feb 2024 8:20 AM

Operating Conditions Liquid


Flow, rated : 44.16 l/s Liquid type : Water
Differential head / pressure, rated (requested) : 186.4 m Additional liquid description :
Differential head / pressure, rated (actual) : 186.6 m Solids diameter, max : 0.00 in
Suction pressure, rated / max : 0.00 / 0.00 psi.g Solids concentration, by volume : 0.00 %
NPSH available, rated : Ample Temperature, max : 68.00 deg F
Site Supply Frequency : 60 Hz Fluid density, rated / max : 1.000 / 1.000 SG
Performance Viscosity, rated : 1.00 cP
Speed criteria : Synchronous Vapor pressure, rated : 0.34 psi.a
Speed, rated : 1750 rpm Material
Impeller diameter, rated : 8.56 in Material selected : Cast Iron
Impeller diameter, maximum : 8.81 in Pressure Data
Impeller diameter, minimum : 8.19 in Shut off pressure : See the Additional Data page
Efficiency (bowl / pump) : 85.85 / - % Maximum allowable working pressure : See the Additional Data page
NPSH required / margin required : 8.38 / 0.00 ft Maximum allowable suction pressure : N/A
Ns (imp. eye flow) / Nss (imp. eye flow) : 2,327 / 9,343 US Units Hydrostatic test pressure : See the Additional Data page
MCSF : 28.40 l/s Driver & Power Data (@Max density)
Head, maximum, rated diameter : 263.7 m Driver sizing specification : Rated power
Head rise to shutoff (bowl / pump) : 41.32 / - % Margin over specification : 0.00 %
Flow, best eff. point (bowl / pump) : 46.89 / - l/s Service factor : 1.15 (used)
Flow ratio, rated / BEP (bowl / pump) : 94.17 / - % Power, hydraulic : 108 hp
Diameter ratio (rated / max) : 97.16 % Power (bowl / pump) : 126 / - hp
Head ratio (rated dia / max dia) : 92.24 % Power, maximum, rated diameter : 134 hp
Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00 Minimum recommended motor rating : 125 hp / 93.21 kW
Selection status : Acceptable
Pump performance. Adjusted for construction, viscosity, static lift to discharge nozzle centerline, friction and power losses of lineshaft and thrust bearings.
The duty point represents the head at the bowl.
400 100
Preferred operating region
360 90

320 80
8.81 in Efficiency
280 70

Efficiency - %
Head - m

240 8.56 in 60
200 8.19 in 50

160 40

120 30

80 20

40 10

0 0
NPSHr - ft

16
NPSHr
8

160
Power - hp

120 Power

80

40

0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Flow - l/s
Pump Performance Curve

Quote Number 1234107


Company Name
Quote Date 22 May 2023
Company contact number Project name Default

Pump performance. Adjusted for construction, viscosity, static lift to discharge nozzle centerline, friction and power losses of lineshaft and thrust bearings.
The duty point represents the head at the bowl.
400 100
Preferred operating region
360 90

320 80
8.81 in Efficiency
280 70

Efficiency - %
240 8.56 in 60
Head - m

8.19 in
200 50

160 40

120 30

80 20

40 10

0 0
NPSHr - ft

16
NPSHr
8

160

Power
Power - hp

120

80

40

0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Flow - l/s

Description : FST-11FLC Enclosed Impeller (STD Model) Speed, rated : 1750 rpm NPSH required : 8.38 ft
Stages : 11 Based on curve number : 11FLC(4POLE) Fluid density, rated / max : 1.000 / 1.000 SG
Flow, rated : 44.16 l/s Efficiency (bowl / pump) : 85.85 % Viscosity : 1.00 cP
Differential head / pressure, : 186.4 m Power (bowl / pump) : 126 / - hp Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00
rated Saved Date : 02 Feb 2024 8:20 AM
Multi-Speed Performance Curve

Quote Number 1234107


Company Name
Quote Date 22 May 2023
Company contact number Project name Default

Pump performance. Adjusted for construction, viscosity, static lift to discharge nozzle centerline, friction and power losses of lineshaft and thrust bearings.
The duty point represents the head at the bowl.
300
Preferred operating region

270

240

210

180
Head - m

150

120 1750 rpm

1575 rpm
90
1400 rpm
60 1225 rpm
1050 rpm
30 875 rpm

160

1750 rpm
120
Power - hp

1575 rpm
80
1400 rpm
40 1225 rpm
1050 rpm
875 rpm
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

Flow - l/s

Description : FST-11FLC Enclosed Impeller (STD Speed, rated : 1750 rpm NPSH required : 8.38 ft
Model) Based on curve number : 11FLC(4POLE) Fluid density, rated / max : 1.000 / 1.000 SG
Stages : 11 Efficiency (bowl / pump) : 85.85 % Viscosity : 1.00 cP
Flow, rated : 44.16 l/s Power (bowl / pump) : 126 / - hp Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00
Differential head / : 186.4 m Impeller diameter, rated : 8.56 in Saved Date : 02 Feb 2024 8:20 AM
pressure, rated
Pump Performance - Additional Data

Company Name Model/Order No. FST-11FLC Enclosed Impeller (STD


Company contact number Model)
Quote Number 1234107 Stages 11
Project name Default Quantity of pumps in parallel 1
Based on curve number 11FLC(4POLE)
Saved Date 02 Feb 2024 8:20 AM

Performance Data Stage, Speed and Solids Limits


Head, maximum diameter, rated flow : 202.3 m Stages, maximum : 25
Head, minimum diameter, rated flow : 164.0 m Stages, minimum :1
Head, maximum, rated diameter : 263.7 m Pump speed limit, maximum : 3600 rpm
Efficiency adjustment factor, total : 1.00 Pump speed limit, minimum : 1200 rpm
Power adjustment, total : 0.00 hp Curve speed limit, maximum : 1800 rpm
Head adjustment factor, total : 1.00 Curve speed limit, minimum : 1200 rpm
Flow adjustment factor, total : 1.00 Variable speed limit, maximum :-
Flow adjustment factor, efficiency only (shift BEP) : 1.00 Variable speed limit, minimum : 5 rpm
Flow adjustment factor, end-of-curve only, total : 1.00 Solids diameter limit : 0.75 in
MCSF adjustment factor : 1.00 Typical Driver Data
NPSHR adjustment factor, total : 1.00 Driver speed, full load : 1785 rpm
User applied performance adjustment comments : Driver speed, rated load : 1785 rpm
NPSH margin dictated by pump supplier : 0.00 ft Driver efficiency, 100% load : N/A
NPSH margin dictated by user : 0.00 ft Driver efficiency, 75% load : N/A
NPSH margin used (added to 'required' values) : 0.00 ft Driver efficiency, 50% load : N/A
Mechanical Limits
Torque, rated power, rated speed : 7.20 hp/100 rpm
Torque, maximum power, rated speed : 7.63 hp/100 rpm
Torque, driver power, full load speed : 7.00 hp/100 rpm
Torque, driver power, rated speed : 7.00 hp/100 rpm
Torque, pump shaft limit : 22.99 hp/100 rpm
Radial load, worst case :-
Radial load limit :-
Impeller peripheral speed, rated :-
Impeller peripheral speed limit :-
Various Performance Data Flow (l/s) Head (m) Efficiency (%) NPSHr (ft) Power (hp)
Shutoff, rated 0.00 263.7 - - 70.37
Shutoff, maximum 0.00 281.3 - - 74.25
MCSF 28.40 217.2 75.68 6.27 107
Rated flow, minimum 44.16 164.0 85.46 - 111
Rated flow, maximum 44.16 202.3 86.01 - 136
BEP flow, rated 46.89 179.5 86.08 8.75 128
120% rated flow, rated 52.99 161.1 84.79 9.82 132
End of curve, rated 63.05 121.5 75.71 12.28 133
End of curve, minimum 59.94 107.9 75.85 11.45 112
End of curve, maximum 65.13 131.5 75.61 12.85 149
Maximum value, rated - 263.7 86.08 - 134
Maximum value, maximum - - 86.49 - 149
System differential pressure @ Density, rated @ Density, max
Differential pressure, rated flow, rated (psi) 265.0 265.0
Differential pressure, shutoff, rated (psi) 374.4 374.4
Differential pressure, shutoff, maximum (psi) 399.4 399.4
Discharge pressure @ Suction @ Suction @ Suction @ Suction
pressure, rated pressure, max pressure, rated pressure, max
Discharge pressure, rated flow, rated (psi.g) 265.0 265.0 265.0 265.0
Discharge pressure, shutoff, rated (psi.g) 374.4 374.4 374.4 374.4
Discharge pressure, shutoff, maximum (psi.g) 399.4 399.4 399.4 399.4
Ratios
Maximum flow / rated flow, rated : 142.78 % Head rated diameter / head minimum diameter, rated flow : 113.77 %
Pump Performance - Additional Data

Head and Power Losses Dimensions


Friction loss rate, column :- Minimum clearance below suction bell lip/case : 10.00 in
Friction loss, column :- Minimum well diameter : 11.19 in
Friction loss, discharge head :- Suction nozzle centerline height :-
Friction loss, can/barrel :- Suction to first stage impeller centerline :-
Friction loss, suction bell and strainer : 0.00 m Bowl assembly length, first stage : 0.00 in
Friction loss, bowl/column adaptor :- Bowl assembly length, upper stage : 9.88 in
Friction loss, total :- Bowl assembly length, total : 98.75 in
Power loss, lineshaft bearings :- Suction bearing hub length : 0.00 in
Power loss, thrust bearing :- Strainer length : 0.00 in
Power loss, total :- Bowl to column adaptor length :-
Bowl vs. Pump Performance Discharge head stick-down :-
Head (bowl / pump) : 186.4 m / - Submersible motor adaptor length :-
Efficiency (bowl / pump) : 85.85 % / - Submersible motor length :-
Power (bowl / pump) : 126 hp / - Column length :-
NPSH required at first stage impeller eye : 8.38 ft Total pump length :-
Weights and Down Thrust Can / barrel length :-
Weight, lineshaft :- Stuffing box sleeve diameter :-
Weight, bowl assembly rotating element : 1,285.0 lb Suction bell diameter :-
Thrust factor : 7.91 lb/ft Minimum submergence to prevent vortexing : 30.00 in
Thrust, hydraulic (rated / max) : 4,828.1 / 6,831.6 lbf Minimum submergence for start-up : 30.00 in
Thrust, bowl shaft end (rated / max) : 0.00 / 0.00 lbf Discharge head height :-
Thrust, shaft step (rated / max) :-/- Discharge nozzle centerline height :-
Thrust, stuffing box sleeve (rated / max) :-/- Min distance discharge nozzle centerline to suction bell : 0.00
Thrust, total (rated / max) : 6,113.1 / 8,116.6 lbf Lineshaft length :-
Thrust Limit :- Bowl shaft diameter : 1.69 in
* Rated thrust @ rated head, density, and suction pressure where applicable Bowl diameter, outside : 11.00 in
* Max thrust @ max head, density, and suction pressure where applicable
Bowl diameter, exit : 8.19 in
Pressure Data Shut off Maximum Hydrostatic test
Column diameter, inside :-
pressure (psi.g) allowable working pressure (psi.g)
pressure (psi.g) Column internal obstruction diameter :-
Bowl 374.4 400.0 600.0 Can/barrel diameter, inside :-
Column - - - Can/barrel obstruction diameter
Discharge head - - - NPSH
Can/Barrel - - - NPSH at bowl (available / required) : Ample / 8.38 ft
Torque Limits NPSH at low liquid level (available / required) :-/-
Torque, lineshaft limit :- NPSH at suction flange (available / required) :-/-
Liquid Velocities
Column liquid velocity :-
Discharge head liquid velocity :-
Can liquid velocity :-
Suction nozzle liquid velocity :-
INTERNAL PRICE SHEET
FST-11FLC Enclosed Impeller (STD
Size / Stages
Company name Model) / 11
Pump speed 1750 rpm
Line item number 001 Quote No. 1234107
Project name Default Date Last Saved 22 May 2023
Totals
Total Extended Net $ 65,983.00 Estimated Lead Time 4 weeks
Pump Total $ 29,313.00

Pump
Qty Description Order No. List Price Multiplier Net Price Margin Unit Sell Extended
Price Sell Price
11FLC-1A-2BS--11-C04-S
1 Model: 11FLC $ 27,113.00 1.000 $ 27,113.00 0.00 % $ 27,113.00 $ 27,113.00
Impeller Type: Enclosed
Bowl shaft diameter: 1-11/16"
NSF/ANSI 61 Certification: No
11 Bowl Material: Cast Iron ASTM A48 Class 30 179-11FLMHC-030 Included Included Included Included
(default)
Bowl Wear Ring Material: None
Bowl Bearing Material: Bronze (Alloy C932) Included Included Included Included
Bolting options: Standard Bolting
Bolting material: 18-8ss Bowl Bolting Included Included Included Included
11 Impeller Material: 304SS Standard (AISI 444-11FLCA-304 Included Included Included Included
Type 304)
11 Impeller Collets: AISI Type 416 SS 225-0007-416 $ 200.00 1.000 $ 200.00 0.00 % $ 200.00 $ 2,200.00
Impeller Dynamic Balance: Standard (ISO Included Included Included Included
Grade 6.3)
1 Bowl Shaft Material: 416 SS (ASTM A582, 760-510076-416 Included Included Included Included
Type 416)
1 Bowl Shaft Cplg Material: 416 SS (ASTM 256-0101-416 Included Included Included Included
A582, Type 416)
Bowl Discharge Type: Threaded
1 Bowl Discharge Bearings Material: Bronze 136-0027-660 Included Included Included Included
(Alloy C932)
Bowl Discharge Size: Select a size
Alert: Please select a bowl discharge size
above
Discharge Head Selection: Customer Supplied
1 Motor Bracket Size: 8 in 816-0121-065
Coating Name: Sherwin Williams - Quick Dry Included Included Included Included
Enamel
Coating Thickness: 2 Mils DFT
Coating Color: Franklin Blue
Bowl Surfaces to be Coated: ID Vitreous Included Included Included Included
Enamel - OD Franklin Blue
Bowl Performance Test: No
Hydrostatic Test - Bowl: No
Material Certifications: None
Field Service/Start-up: No
INTERNAL PRICE SHEET
Project name Default Quote No. 1234107
Line item number 001 Date Last Saved 22 May 2023

Pump
Qty Description Order No. List Price Multiplier Net Price Margin Unit Sell Extended
Price Sell Price
Warranty: Standard (1 year) Included Included Included Included
Expedite Order Delivery: No

Motor
Qty Description Order No. List Price Multiplier Net Price Margin Unit Sell Extended
Price Sell Price
1 Motor: 8'' MagForce Three-Phase, 125 HP, 2630165331 $ 36,670.00 1.000 $ 36,670.00 0.00 % $ 36,670.00 $ 36,670.00
SAND FIGHTER, 460V, 120Hz, 1.15 SF , 3-
Lead, 2630165331

Identifier Codes
Assembly Qty Code
1 Smart Part number=11FLC-1A-2BS--11-C04-S
SCREW SandCap
SCREW DischCase 1
SCREW BowlSuct
SUCTION CASE 1
COUPLING 1
BowlShaft Barstock
SAND CAP 1
CASING BOWL
COLLET
DISCHARGE CASE 1
ORING
IMPELLER 1
PLUG DischargeCase
PLUG SuctionCase 1
QUOTATION

Quote Information / / /
Quote No. 1234107
Arguello, Daniel ( [email protected])
Quote Date 22 May 2023
Project name Default
Est. Leadtime ARO 4 weeks

Customer Information Totals


To Total Extended Net $ 65,983.00
Street Address Pump Total $ 29,313.00
City/State/Zip / / Motor Total $ 36,670.00
Phone No.

Pump
Order No. Qty Description Unit Price Extended Sell Price
1 11FLC-1A-2BS--11-C04-S
Bowl
Configuration
1 Model: 11FLC $ 27,113.00 $ 27,113.00
Impeller Type: Enclosed
Bowl shaft diameter: 1-11/16"
NSF/ANSI 61 Certification: No
Material options
179-11FLMHC-030 11 Bowl Material: Cast Iron ASTM A48 Class 30 (default) Included Included
Bowl Wear Ring Material: None
Bowl Bearing Material: Bronze (Alloy C932) Included Included
Bolting material: 18-8ss Bowl Bolting Included Included
Impeller options
444-11FLCA-304 11 Impeller Material: 304SS Standard (AISI Type 304) Included Included
225-0007-416 11 Impeller Collets: AISI Type 416 SS $ 200.00 $ 2,200.00
Impeller Dynamic Balance: Standard (ISO Grade 6.3) Included Included
Bowl shaft options
760-510076-416 1 Bowl Shaft Material: 416 SS (ASTM A582, Type 416) Included Included
256-0101-416 1 Bowl Shaft Cplg Material: 416 SS (ASTM A582, Type 416) Included Included
Discharge options
Bowl Discharge Type: Threaded
136-0027-660 1 Bowl Discharge Bearings Material: Bronze (Alloy C932) Included Included
Bowl Discharge Size: Select a size
Alert: Please select a bowl discharge size above
Submersible Motor
Configuration
816-0121-065 1 Motor Bracket Size: 8 in
Coating
Configuration
Bowl Assembly Coating
Coating Name: Sherwin Williams - Quick Dry Enamel Included Included
Coating Thickness: 2 Mils DFT
QUOTATION

Quote Information Totals


Quote No. 1234107 Total Extended Net $ 65,983.00
Quote Date 22 May 2023 Pump Total $ 29,313.00
Project name Default Motor Total $ 36,670.00
Est. Leadtime ARO 4 weeks

Pump
Order No. Qty Description Unit Price Extended Sell Price
Coating Color: Franklin Blue
Bowl Surfaces to be Coated: ID Vitreous Enamel - OD Franklin Included Included
Blue
Other Optional Features or Requirements
Special Services / Warranty Options
Warranty: Standard (1 year) Included Included
Pump Total $ 29,313.00

Motor
Order No. Qty Description Unit Price Extended Sell Price
Submersible Motor
Configuration
2630165331 1 Motor: 8'' MagForce Three-Phase, 125 HP, SAND FIGHTER, $ 36,670.00 $ 36,670.00
460V, 120Hz, 1.15 SF , 3-Lead, 2630165331
Motor Total $ 36,670.00
QUOTATION

Quote Information / / /
Quote No. 1234107
Arguello, Daniel ( [email protected])
Quote Date 22 May 2023
Project name Default
Est. Leadtime ARO 4 weeks

Customer Information
To
Street Address
City/State/Zip / /
Phone No.

Pump
Order No. Qty Description
1 11FLC-1A-2BS--11-C04-S
Bowl
Configuration
Model: 11FLC
Impeller Type: Enclosed
Bowl shaft diameter: 1-11/16"
NSF/ANSI 61 Certification: No
Material options
179-11FLMHC-030 11 Bowl Material: Cast Iron ASTM A48 Class 30 (default)
Bowl Wear Ring Material: None
Bowl Bearing Material: Bronze (Alloy C932)
Bolting material: 18-8ss Bowl Bolting
Impeller options
444-11FLCA-304 11 Impeller Material: 304SS Standard (AISI Type 304)
225-0007-416 11 Impeller Collets: AISI Type 416 SS
Impeller Dynamic Balance: Standard (ISO Grade 6.3)
Bowl shaft options
760-510076-416 1 Bowl Shaft Material: 416 SS (ASTM A582, Type 416)
256-0101-416 1 Bowl Shaft Cplg Material: 416 SS (ASTM A582, Type 416)
Discharge options
Bowl Discharge Type: Threaded
136-0027-660 1 Bowl Discharge Bearings Material: Bronze (Alloy C932)
Bowl Discharge Size: Select a size
Alert: Please select a bowl discharge size above
Submersible Motor
Configuration
816-0121-065 1 Motor Bracket Size: 8 in
Coating
Configuration
Bowl Assembly Coating
Coating Name: Sherwin Williams - Quick Dry Enamel
Coating Thickness: 2 Mils DFT
QUOTATION

Quote Information
Quote No. 1234107
Quote Date 22 May 2023
Project name Default
Est. Leadtime ARO 4 weeks

Pump
Order No. Qty Description
Coating Color: Franklin Blue
Bowl Surfaces to be Coated: ID Vitreous Enamel - OD Franklin Blue
Other Optional Features or Requirements
Special Services / Warranty Options
Warranty: Standard (1 year)

Motor
Order No. Qty Description
1 Submersible Motor
Configuration
2630165331 1 Motor: 8'' MagForce Three-Phase, 125 HP, SAND FIGHTER, 460V, 120Hz, 1.15 SF , 3-Lead, 2630165331
Quote Number
Quote Date 10 Sep 2020
Revision

Dimensional Information (11FLC-1A-2BS--11-C04-S)

Dim Value
A -1.00
B -1.00
C -1
D 8.00
E -1
F -1.00
G -1.00
H -14.00
I -1.00
J -
K -
L -
M -1.00

Disch Head Side View

NOTES:
1. ALL DIMENSIONS ARE IN INCHES +/- 0.375
2. NOT FOR CONSTRUCTION UNLESS CERTIFIED BY ENGINEERING

Project Name: Default Certified For:


PO/REF ID: Certified By:
Date: Customer:
Quoted By: Customer Contact:
Quoted By Phone: Customer Phone:
FST Vertical Turbine
Dimensional Information
(Bowl Assembly)
Drawing Number: Rev:
Quote Number
Quote Date 10 Sep 2020
Revision

Product Datasheet (11FLC-1A-2BS--11-C04-S)


Item Number: 001 Lube Type: Pump Speed: 1750 rpm
Pump Model: FST11FLC Number of Stages: 11

General Data
Flow: 44.16 l/s Head: 186.4 m NPSHR: 8.38 ft
Liquid: Water SG: 0.9983 Efficiency: 85.85 %
Liquid Temp.: 68.00 deg F Viscosity: 1.00 cP MCSF: 28.40 l/s

Pump Data
Bowl Model: 11FLC Column Conn. Size: 0.00 in DH Model: -
Stages: 11 Column Conn. Type: Threaded Flange Size: -
Bowl Shaft Diameter: 1-11/16" LS Coupling Size: - DH Construction: -
Impeller Type: Enclosed Lineshaft Diameter: - Column Size:
Impeller Dia.: 8.56 in Total Rated Thrust: 6,113.1 lbf Col Pipe Wall Thickness:
Impeller Conn. Type: Collet Power Rated: 125 hp Strainer Type: -

Material Data
Bowl: Cast Iron ASTM A48 Class 30 (default) Impeller: 304SS Standard (AISI Type 304) Motor Coupling: -
Bowl WR: None Impeller WR: None Col Pipe:
Bowl Shaft: 416 SS (ASTM A582, Type 416) Lineshaft: - Motor Bracket: -
Collet: AISI Type 416 SS Bowl Bearing: Bronze (Alloy C932) Suction Screen: Stainless Steel

Motor Data
MFG: Franklin Electric HP: 125 hp Motor Size: 8 in
Type: SAND FIGHTER RPM: 1750 rpm Phase: 3
Frame: - Volts: 460V Frequency: 60 Hz
Catalog: 2630165331

Weights Mechanical Seal Data


Est. Pump Wt.: -11.00 lb Mfg: Type:
Est. Motor Wt.: 375.0 lb Size: API Code:

Coatings
Bowl ID: Vitreous Enamel Bowl OD: Franklin Blue
Column ID: - Column OD: -
Head ID: - Head OD: Franklin Blue
Tube OD: -

Project Name: Default Certified For:


PO/REF ID: Certified By:
Date: Customer:
Quoted By: Customer Contact:
Quoted By Phone: Customer Phone:
FST Vertical Turbine
Product Datasheet
(Bowl Assembly)
Drawing Number: Rev:
Quote Number
Quote Date 10 Sep 2020
Revision

Bill of Materials (11FLC-1A-2BS--11-C04-S)

ITEM DESCRIPTION QTY PART NUMBER


816 MOTOR BRACKET 1 816-0121-065
136D DISCHARGE CASE BEARING 1 136-0027-660
179 BOWL ASSEMBLY 11 179-11FLMHC-030
225 IMPELLER COLLET 11 225-0007-416
256 LINESHAFT COUPLING 1 256-0101-416
302 DISCHARGE CASE 1
364 BOWL O-RING 12 364-0147-BN
444 IMPELLER 11 444-11FLCA-304
616D DISCHARGE CASE PLUG 2 616-0003-STL
364L LIP SEAL 1
708 ASSEMBLY HEX SCREWS 144 708-0077-188
760 BOWL SHAFT 135.88 760-510076-416
006 SUCTION SCREEN 0 -
- 0 -
- 0 -
-
- -
- -
- -

IMPELLER TRIM: 8.56 in

NOTES:
1. ALL DIMENSIONS ARE IN INCHES +/- 0.375
2. NOT FOR CONSTRUCTION UNLESS CERTIFIED BY ENGINEERING

Project Name: Default Certified For:


PO/REF ID: Certified By:
Date: Customer:
Quoted By: Customer Contact:
Quoted By Phone: Customer Phone:
FST Vertical Turbine
Bill of Materials
(Bowl Assembly)
Drawing Number: Rev: