Manual-Tina2ABOriginalinstructions_Rev_D

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Original instructions

Tina 2A/B
Adaptor unit

ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden


www.abb.com/jokabsafety
Read and understand this document
Please read and understand this document before using the products. Please consult your ABB JOKAB SAFETY
representative if you have any questions or comments.
WARRANTY
ABB JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship
for a period of one year (or other period if specified) from date of sale by ABB JOKAB SAFETY.
ABB JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED,
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF
THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED
USE. ABB JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED.
LIMITATIONS OF LIABILITY
ABB JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on
which liability asserted.
IN NO EVENT SHALL ABB JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS ABB JOKAB SAFETY’S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
ABB JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply
to the combination of products in the customer’s application or use of the product. At the customer’s request, ABB
JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of use
that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of
the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended
to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be
suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not
described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment,
amusement machines, vehicles, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE ABB JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
While every effort has been taken to ensure the accuracy of the information contained in this manual ABB JOKAB
SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and
improvements without notice. Performance data given in this document is provided as a guide for the user in
determining suitability and does not constitute a warranty. It may represent the result of ABB JOKAB SAFETY’S
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to
the ABB JOKAB SAFETY Warranty and Limitations of Liability.

2TLC172121M0201, rev. D 2 www.abb.com/jokabsafety


2014-02-03
Table of Contents
1 Introduction ......................................................................................................................................... 4
Scope ........................................................................................................................................................................ 4
Audience ................................................................................................................................................................... 4
Prerequisites ............................................................................................................................................................. 4
Special notes ............................................................................................................................................................ 4

2 Overview .............................................................................................................................................. 5
General description ................................................................................................................................................... 5
Safety regulations ..................................................................................................................................................... 5
3 Connections ........................................................................................................................................ 6
Connection examples ............................................................................................................................................... 7

4 Installation and maintenance ............................................................................................................. 8


Installation precautions ............................................................................................................................................. 8
Maintenance ............................................................................................................................................................. 8
Testing of the safety functions .................................................................................................................................. 8
Troubleshooting ........................................................................................................................................................ 8

5 Operation ............................................................................................................................................. 9
LED indication ........................................................................................................................................................... 9
Information output signal attributes........................................................................................................................... 9
6 Technical data ................................................................................................................................... 10
Dimensions ............................................................................................................................................................. 10

7 EC Declaration of conformity ........................................................................................................... 12

2TLC172121M0201, rev. D 3 www.abb.com/jokabsafety


2014-02-03
1 Introduction
Scope
The purpose of these instructions is to describe the adaptor units Tina 2A/B and to provide the necessary
information required for installation and operation.

Audience
This document is intended for authorized installation personnel.

Prerequisites
It is assumed that the reader of this document has knowledge of the following:
• Basic knowledge of ABB Jokab Safety products.
• Knowledge of machine safety.

Special notes
Pay attention to the following special notes in the document:

Danger of severe personal injury!


Warning! An instruction or procedure which, if not carried out correctly, may result in injury to the technician
or other personnel.

Danger of damage to the equipment!


Caution!
An instruction or procedure which, if not carried out correctly, may damage the equipment.

NB: Notes are used to provide important or explanatory information.

2TLC172121M0201, rev. D 4 www.abb.com/jokabsafety


2014-02-03
2 Overview
General description
ABB Jokab Safety adaptor units are used to adapt conventional safety sensors where the safety relies on e.g. one-
or two-channel static signals, OSSD outputs, or short circuit detection, to the dynamic safety circuit monitored by a
Vital safety module or Pluto safety-PLC.
Tina 2A and Tina 2B are used to adapt safety sensors with mechanical contacts to the dynamic safety circuit.
Examples of such safety sensors are emergency stops and switches or light curtains and light beams with internal
relay outputs.
Tina 2A is intended for safety sensors prepared with an M20 threaded connector. This allows easy installation of
the adaptor unit within the physical enclosure of the safety sensor while keeping the status LED visible on the
outside of the housing. Tina 2B has a very small form factor which allows installation inside the physical enclosure
of small safety sensors, or safety sensors without an M20 threaded connector.
The Tina2A/B adaptor unit is intended for use in safety circuits in accordance with EN 60204-1.

Warning! In order to maintain the highest safety level and reduce the risk of electrical interference the unit must be
installed within the same physical encapsulation as the safety device. The connection cable should be as short as
possible (max 150 mm).

Safety regulations
Warning!
Carefully read through this entire manual before using the device.
The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine
directive.
Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions,
improper installation or handling of the device can affect the safety of people and the plant.
For installation and prescribed use of the product, the special notes in the instructions must be carefully observed
and the technical standards relevant to the application must be considered.
In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the
product, any liability is excluded.

2TLC172121M0201, rev. D 5 www.abb.com/jokabsafety


2014-02-03
3 Connections

5-pole connection cables:


1 ) Brown: +24 VDC
2 ) White: Dynamic signal input
3 ) Blue: 0 VDC
4 ) Black: Dynamic signal output
5 ) Grey: Information

2
NB: The connection cable cross section area is 0.34 mm and cable length is 150 mm.
Caution! The connection cables should not be extended as longer cables increase the risk for electrical
interference.

Warning!
The information channel output shall never be used for the safety purpose(s).
The connection cables are not monitored and must therefore be installed within the same physical enclosure as the
safety device to maintain the highest safety level (fault exclusion, refer to EN ISO 13849-2:2003 Annex D).
The safety adaptor shall not be used for purposes other than intended. All loading or tampering with the device can
lead to serious risk of life.

2TLC172121M0201, rev. D 6 www.abb.com/jokabsafety


2014-02-03
Connection examples

Caution! All cable colours according to ABB Jokab Safety standard cables.

2TLC172121M0201, rev. D 7 www.abb.com/jokabsafety


2014-02-03
4 Installation and maintenance
Installation precautions
The unit must first attach to the M20 connector (Tina 2A) before the safety loops are connected to the sensor.
Warning! All the safety functions must be tested before starting up the system.

Maintenance
Warning!
The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the
safety functions are working properly (EN 62061:2005).
In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety Service Office or reseller.
Do not try to repair the product yourself since it may accidentally cause permanent damage to the product,
impairing the safety of the device which in turn could lead to serious injury to personnel.

Testing of the safety functions


Make sure the safety unit is working properly by following these steps:
• Interrupt the dynamic safety circuit before this unit. The LED should flash between green and red.

• Interrupt protection. The LED should flash between green and red.

• The LED will light green when protection is OK and if the safety circuit(s) before this unit is not interrupted.

Troubleshooting
LED indication Expected causes of faults Checking and measures to take

Check if there is 24 VDC to input (pin-2). If


Lights red 24 VDC input to pin-2 (no dynamic signal)
Yes, check cable or unit before and fix it.

No lights Loss of power supply Check 24 VDC / 0 VDC power supply

Lights green (but no dynamic output Defected dynamic signal input to unit
Check the dynamic input or the unit before
detected) (asymmetric pulses)

Weak lights or red and green lights at the The unit needs to be replaced. Contact ABB
The unit is defect
same time Jokab Safety.

Warning! Replace defected unit with a new one and never bypass the safety circuit using Tina 1A or any other
solution.

2TLC172121M0201, rev. D 8 www.abb.com/jokabsafety


2014-02-03
5 Operation
LED indication
LED Indication Description Input signal on pin-2

Green Safety circuit closed (protection OK) Dynamic signal in

LED on Tina Green-Red (flash) Safety circuit open (protection OK) No dynamic signal in or 0 VDC in

Red - +24 VDC in

Information output signal attributes


The information output of the unit (pin-5) is set either high (+24 VDC) or low (0 VDC) depending on four different
input signals (pin-2):
• Dynamic signal - Dynamic signal input exist, i.e. the safety circuit is OK up until this unit
• No dynamic signal - Dynamic signal input does not exist, i.e. the safety circuit is interrupted before this
unit.
• +24 VDC - A constant +24 VDC signal is applied = high (H)
• 0 VDC - The pin is connected to 0 VDC = low (L)
The information output signal depends on the input signal according to the table below. Note that if the safety is
interrupted the information output signal is always low (L).

Input signal (pin-2) Dynamic signal No dynamic signal +24 VDC 0 VDC

Info output signal (pin-5) High Low Low Low

The delay for switching the information signal output from high to low (H  L) and low to high (L  H) is given in
the table below.

Info output signal switch HL LH

Delay ~ 95 ms ~ 80 ms

Warning! The information output signal is not a failsafe signal and should never be used for the safety purpose(s).

2TLC172121M0201, rev. D 9 www.abb.com/jokabsafety


2014-02-03
6 Technical data
Manufacturer

Address ABB JOKAB SAFETY


Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden

Article number/Ordering data Tina 2A: 2TLA020054R0100


Tina 2B: 2TLA020054R1100

Power supply

Operating voltage 24 VDC +15 %, -25 %

Total current consumption 17 mA (27 mA with max information output)


Information output: Max 10 mA

Time delay t (in/out) t < 60 µs

Voltage supply at normal operation (protection Dynamic input: between 9 and 13 volt (RMS)
OK) and 24 VDC supply voltage Dynamic output: between 9 and 13 volt (RMS)
Information output: ~ 23 VDC

General

Protection class IP67

Ambient temperature Storage: -30…+70°C


Operation: -10…+55°C

Humidity range 35 to 85 % (with no icing or condensation)

Housing material PVC

Connector 5x 0.34 mm2 wires, 0.15 m

Size Tina 2A: 46 x 27 x 24 mm


Tina 2B: 26 x 21 x 7 mm (L x W x H)

Weight Tina 2A: ~30 g


Tina 2B: ~20 g

Colour Black

Safety / Harmonized Standards

Conformity European Machinery Directive 2006/42/EC

EN ISO 12100-1:2003, EN ISO 12100-2:2003,


EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008,
EN 62061:2005

IEC/EN 61508-1…7 SIL3, PFHd: 4.50*10-9

EN 62061 SIL3

EN ISO 13849-1 Performance level: Pl e, category 4

EN 954-1 Category 4

Certificates TÜV Nord, cCSAus

The Jokab Safety branded product with article number beginning with 2TLJ is fully compatible with the ABB
branded product with article number beginning with 2TLA.

2TLC172121M0201, rev. D 10 www.abb.com/jokabsafety


2014-02-03
Dimensions
Tina 2A

Tina 2B

NB: All measurements in millimetres.

2TLC172121M0201, rev. D 11 www.abb.com/jokabsafety


2014-02-03
7 EC Declaration of conformity

ABB JOKAB SAFETY Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden

www.abb.com/jokabsafety

2TLC172121M0201, rev. D 12 www.abb.com/jokabsafety