DATSERA1S23BREN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DIGITAL LIVING E-MEDICAL

Sentinel Rack
EMERGENCY INDUSTRY

1:1 1500-3000 VA

ONLINE

Rack

Plug & Play


installation

USB
plug

HIGHLIGHTS
Sentinel Rack has compact design and provide increased efficiency and greater
• Power factor 0.9 improved performance developed by the configuration options.
Riello UPS research and development Maximum expandability: the Sentinel
• Operating flexibility team. Sentinel Rack uses ON LINE Rack is supplied as standard with a USB
double conversion technology, resulting port and an expansion slot for protocol
• Emergency function in the highest levels of reliability and conversion or relay contacts boards.
maximum protection for critical loads With energy savings in mind, Sentinel Rack
• Battery optimisation such as servers and IT and voice/data is also fitted with a shut-off switch to
applications. For business continuity reduce energy consumption to zero during
• Runtime expandability
applications requiring long battery prolonged periods of inactivity (ECO LINE).
• Compact design runtimes, battery autonomy can be Sentinel Rack is available in 1500 VA and
extended up to several hours using the 3000 VA models.
• Rack depth of 380 mm 3000 VA model fitted with more powerful
battery charger. The front display panel OPERATING FLEXIBILITY
has been entirely redesigned, adding an Different operating modes are available
LCD display that shows the input and to reduce energy consumption based on
output voltages, battery readings and UPS specific load and user requirements.
operating status information. The inverter • ON LINE: maximum load protection and
and the microprocessor control stage output voltage waveform quality;
• ECO Mode: the UPS uses LINE
INTERACTIVE technology, with the
load powered by the mains, reducing
consumption and thus improving
efficiency (up to 98%);
• SMART ACTIVE Mode: the UPS
automatically selects ON LINE or LINE
INTERACTIVE operation, depending on
the quality of the mains supply, checking
the number, frequency and type of
disturbances present;
• STANDBY OFF: the UPS supplies the load
only when the mains fails. The inverter
begins working with a progressive start
up sequence to prevent inrush currents;
• Frequency Converter operation (50 or
60 Hz).

EMERGENCY FUNCTION
This configuration ensures the operation
of emergency systems that must be
supplied in the event of a mains power
failure, such as emergency lighting, fire RUNTIME EXPANDABILITY (SER 3000) ADVANCED COMMUNICATIONS
detection/extinguishing systems and Optional battery extension packs can be • Multi-platform communication for
alarms. When the mains power supply connected to increase UPS runtime. all operating systems and network
fails, the inverter begins powering the SER 3000 ER version is designed without environments: PowerShield3 supervision
loads with a progressive start up (Soft internal batteries and a more powerful and shutdown software for Windows
Start) in order to prevent overload. battery chargers to achieve longer operating systems 11, 10, 8, Server
Sentinel Rack is compliant for installation runtimes. 2022, 2019, 2016 and previous versions,
in medium-voltage transformer rooms in Windows Server Virtualization Hyper-V,
accordance with applicable legislation, for LOW NOISE LEVEL macOS, Linux, Citrix XenServer and other
the power supply with reserve charge of Thanks to the use of high frequency Unix operating systems;
medium-voltage coils. components and load-based fan speed • UPS Tools configuration and
control, the noise produced by the UPS is customisation software supplied as
BATTERY OPTIMISATION less than 40 dBA. standard;
The Sentinel Rack range has a deep • RS232 serial port and opto-isolated
discharge protection device to optimise FEATURES contacts;
battery life. • Filtered, stabilised and reliable voltage: • USB port;
Periodically the UPS carries out a battery double conversion ON LINE technology • Slot for communications boards.
efficiency test (which can also be (VFI compliant with IEC 62040-3)
manually activated); its wide input voltage with filters for the suppression of 2-YEAR WARRANTY
tolerance range helps to reduce battery atmospheric disturbances;
usage and maintain performance over • High overload capability (up to 150%);
time. • Programmable Auto-restart when mains
is restored;
• Battery start up (Cold Start);
• Power factor correction (UPS input
power factor, close to 1);
• Wide input voltage tolerance range
(from 140 V to 276 V) without battery
intervention.
• Runtime extendable up to several hours;
• Fully configurable using UPS Tools
configuration software;
• Highly reliable batteries (automatic and
manually-activated battery test);
• High level of UPS reliability (total
microprocessor control);
• Low impact on the mains (sinusoidal
take up).
OPTIONS BATTERY CABINET

SOFTWARE MULTICOM 352 MODELS BTC SER 72V BB A5


PowerShield3 MULTICOM 372
PowerNetGuard MULTICOM 384
MULTI I/O
ACCESSORIES MULTIPANEL

87
Dimensions
NETMAN 208 Manual Bypass 16 A Rack [mm]
MULTICOM 302 45 BTC
0 0
38

DETAILS

SER 1500 SER 3000

USB PORT USB PORT


COMMUNICATION COMMUNICATION COMMUNICATION SLOT OUTPUT SOCKETS COMMUNICATION
SLOT INPUT SOCKET PORT R.E.P.O. PORT R.E.P.O.

ON/OFF SWITCH RS232 SERIAL BATTERY CONNECTOR RS232 SERIAL


OUTPUT INTERFACE INTERFACE
SOCKETS INPUT SOCKET

BTC

BATTERY CONNECTOR

BATTERY EXPANSION
CONNECTOR
MODELS SER 1500 SER 3000 ER

POWER 1500 VA/1350 W 3000 VA/2700 W

INPUT
Rated voltage [V] 220 / 230 / 240
Voltage range without
140 <Vin <276 @ 50% load / 184 <Vin <276 @ 100% load
battery intervention [V]
Voltage tolerance [V] 230 ±20%
Maximum permitted voltage [V] 300
Rated frequency [Hz] 50 / 60
Frequency tollerance [Hz] 50 ±5% / 60 ±5%
Power factor >0.99
Current distortion ≤7%
BYPASS
Voltage tolerance [V] 180 / 264
Frequency tolerance [Hz] Frequency selected (from ±1.5 to ±5 configurable)
Overload times 125% for 5 s, 150% for 1 s
OUTPUT
Voltage distortion with linear
<2% / <4%
load / with non-linear load
Frequency [Hz] Selectable: 50 or 60 or self-learning

The information in this document is subject to change without notice. Riello UPS assumes no responsibility for any errors that may appear in this document.
Static variation ±1%
Dynamic variation ≤5% in 20 ms
Waveform Sinusoidal
Current crest factor 3:1
Efficiency ECO and SMART
98%
ACTIVE Modes
BATTERIES
Type VRLA AGM maintenance-free lead based
Recharge time 2-4 h
OVERALL SPECIFICATIONS
Net weight [kg] 22 14 (without batteries)
Gross weight [kg] 24 18
Dimensions (WxDxH) [mm] 450x380x87 (19”x380x2U)
Packaging dimensions
540x490x190
(WxDxH) [mm]
Protection against
300
overvoltage [J]
Protections Overcurrent - short circuit - overvoltage - undervoltage - temperature - excessive low battery
Communications USB / DB9 with RS232 and contacts / Slot for communications interface
Input plugs 1x IEC 320 C14 (10 A) 1x IEC 320 C20 (16 A)
Output sockets 8x IEC 320 C13 (10 A) 8x IEC 320 C13 (10 A) + 1x IEC 320 C19 (16 A)
European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility
Standards Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant
Classification in accordance with IEC 62040-3 (Voltage Frequency Indipendent) VFI - SS - 111
Ambient temperature
0 °C - +40 °C
for the UPS
Recommended temperature
+20 °C - +25 °C
for battery life
Range of relative humidity 5-95% non-condensing
Colour RAL 9005
DATSERA1S23BREN

Noise level at 1 m
<40
(ECO Mode) [dBA]
Standard equipment
Power cable, IEC-IEC cable, USB cable, safety manual, quick start guide
provided

RPS SpA - Riello Power Solutions - Member of the Riello Elettronica Group
Viale Europa, 7 - 37045 Legnago (Verona) - ITALY - Tel: +39 0442 635811
www.riello-ups.com