BOQJNV66 A
BOQJNV66 A
1 Construction MP Hall
a Civil Work 2,68,63,891 - 22,10,332 2,90,74,223
b Plumbing Work 6,13,336 7,770 2,51,333 8,72,439
c Electrical Work 21,840 12,37,928 8,14,861 20,74,629
d Fire Fighting Work - 6,59,428 2,72,329 9,31,757
e Fire Alarm Work - 59,788 87,288 1,47,076
l Sound System - - 6,00,000 6,00,000
m Line Marking for Sports - - 1,00,000 1,00,000
Total (A) 2,74,99,067 19,64,914 43,36,143 3,38,00,124
2 Cost of Development Works
a CC Road 96,204 - - 96,204
b Pathway 2,17,923 - - 2,17,923
c External Water Supply 37,641 - 40,000 77,641
d Apron Drain 2,76,122 - - 2,76,122
e External Sewerage Lines 3,96,599 - - 3,96,599
f External Electrification -
1-Earthing & Miscellaneous items - 68,431 16,000 84,431
2-Supply & Laying of Cable - 14,601 36,495 51,096
3-External Lights - - 70,537 70,537
Total (B) 10,24,488 83,032 1,63,033 12,70,553
Total (A+B) 3,50,70,677
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand
(zone-III) derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry
16 4.17 SQM 127.940 749.30 - 95,865.44
brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine
sand,including necessary excavation,levelling & dressing & finishing the top smooth.
Providing and laying in position ready mixed or site batched design mix cement concrete
for reinforced cement concrete work; using coarse aggregate and fine aggregate derived
from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering,
29 5.33 -
shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the
following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix
shall be payable separately. In case the cement content in design mix is more than 110% of
the specified minimum cement content, the contractor shall have discretion to either re-
design the mix
or bear the cost of extra cement.
30 5.33.1 All works upto plinth level -
31 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum -
32 5.33.1.1 (i) R.C.C. work in Footing CUM 92.780 9504.75 - 8,81,850.71
33 5.33.1.1 (ii) R.C.C. work in Beam CUM 42.710 9504.75 - 4,05,947.87
34 5.33.1.2 Concrete of M30 grade with minimum cement content of 350 kg /cum -
35 5.33.1.2 (iii) R.C.C. work in Columns CUM 20.710 9655.70 - 1,99,969.55
36 5.33.2 All works above plinth level upto floor V level -
37 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum -
38 5.33.2.1 (i) R.C.C. work in Lintel CUM 5.060 9860.40 - 49,893.62
39 5.33.2.1 (ii) R.C.C. work in Beam CUM 93.035 9860.40 - 9,17,362.31
40 5.33.2.1 (iv) R.C.C. work in Slab CUM 124.830 9860.40 - 12,30,873.73
41 5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum -
Providing & fixing of 100% Natural Material- Magnesite (Hygroscopic & biologically sound
binding agent) bonded woodwool Panel planks of 600Mm*1200Mm *25Mm thickness
made out of wood wool fibre of width 1Mm Fiber thickness mixed with Natural water &
Magnesite (No-Cement) with open & smooth surface texture. A Completly harmless
Envirenment & Human Friendly & also a disposable or recyclable Material & can last for
long span in building interiors As it has long lifespan & suitable for Indoor conditions with
relative air humidity of upto 90%. Magnesite protects the wood cells against ageing &
fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200Mm from wall slab
61 MR along with the backing of Mineral of 50kg/m3. Edge Detail : AK 01 sqm 0.00 10800.00 - -
Heradesign Woodwool - Acoustical Wall Mounting System Solutions- Ecologically Sound
Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test
DIN18032 & EN13964 with flying colors & A sustainable material (PEFC & FSC Certified)
along with EPD Certified Acc. to EN ISO 14025 (AUB-Environmental Product declaration).
Note: Rate of hardware items deemed to be include in above items. All Hardware required
73 as per approved shop drawing should pass European certificate "CE" of conformity / UL -
with required fire ratings.
Providing and fixing bright /matt finished Stainless Steel handles of approved quality &
74 9.165.1 NOS 26.000 119.20 - 3,099.20
make with necessary screws etc all complete. (a) 125 mm.
Providing & fixing Stainless steel (grade SS-304 or higher) sliding door bolt/aldrop of size
75 M.R. NOS 13.000 719.00 9,347.00
250x16mm on door shutter including all accessories as per direction of E/I -
Providing and fixing Stainless steel (grade SS-304 or higher) tower bolt (barrel type) with
76 -
necessary screws etc. complete all work as per direction of E/I
77 M.R. 300 x 10mm NOS 13.000 - 448.00 5,824.00
78 M.R. 200 x 10mm NOS 13.000 - 392.00 5,096.00
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer rod of approved quality as per architectural
79 21.8.1 RM 299.200 96.75 - 28,947.60
drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
80 Steel Work -
Steel work in built up tubular (round, square or rectangular hollow tubes
etc.) trusses etc., including cutting, hoisting, fixing in position and
81 10.16.1 applying a priming coat of approved steel primer, including welding and KG 2000.00 194.40 - 3,88,800.00
bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Designing, Providing, installing and fixing factory finished customed
design pregalvanized high tensile steel joists manufactured from G350 Z275 confirming to
82 26.62 IS:277-1992, minimum coating of galvanizing 275 gm/sqm, minimum yield stress 35 MPa & KG 50.00 182.05 - 9,102.50
minimum tensile strength of 380 MPa placed 1.23 metre apart to support the load of slab
etc as per the design & directions of Engineer-in-Charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c
84 10.26.1 KG 1274.570 196.80 - 2,50,835.38
fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel
bolts etc., of required size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-charge.
85 Flooring -
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed
with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing
86 11.20.2 and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse SQM 96.050 1328.35 - 1,27,588.02
sand). Medium shade pigment using 50% white cement 50%
Grey cement
Marble stone flooring with 18 mm thick marble stone, as per sample
of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement
87 11.23 -
mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including
rubbing and polishing complete with :
88 11.23.2 Raj Nagar plain SQM 21.750 2346.80 - 51,042.90
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm
thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement
89 11.4 hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening SQM 731.250 978.45 - 7,15,491.56
compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications.
This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming
117 13.48A.1 SQM 105.914 181.25 - 19,196.82
coat of exterior primer applied @ 0.90 litre/10 sqm.
118 MR Providing and fixing GRC Bricktile 15mm thickness SQM 0.00 1955.00 - -
34 - - -
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
35 DSR 1.32 Each 15 617.41 - 9,261.14 -
fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A
modular switch, connections etc. as required.
36 - - -
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block
37 DSR-1.33 Each
including connections etc. as required. 2 91.66 - 183.33 -
38 - - -
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in
recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP
39 DSR-1.57 Each
MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
2 765.97 - 1,531.93 -
40 - - -
Supplying and fixing following modular switch/ socket on the
41 DSR 1.24 existing modular plate & switch box including connections but
excluding modular plate etc. as required. - - -
42 DSR 1.24.6 Telephone socket outlet Nos 4 155.93 - 623.73 -
43 - - -
Supplying and fixing following size/ modules, GI box alongwith
44 DSR 1.27 modular base & cover plate for modular switches in recess etc.
as required. - - -
45 DSR 1.27.1 1 or 2 Module (75mmX75mm) Nos 4 313.97 - 1,255.89 -
46 - - -
Supplying and fixing following size/ modules, GI box alongwith
47 DSR 1.24 modular base & cover plate for modular switches in recess etc.
as required. - - -
78 - -
Supplying and fixing two module stepped type electronic fan
79 DSR 1.25 regulator on the existing modular plate switch box including Each
connections but excluding modular plate etc. as required. 8 388.78 - 3,110.23
80 - -
Installation, testing and commissioning of ceiling fan, including
wiring the down rods of standard length (upto 30 cm) with 1.5
81 DSR 1.44 Each
sq. mm FRLS PVC insulated, copper conductor, single core cable
etc. as required. 8 224.42 - 1,795.33
Supply of following sizes of heavy duty Domestic exhaust fan for single phase 230 volt,
82 NSI-9 50HZ AC supply complete with motor, blades, frame, bracket, louver/ shutter etc as
required. - -
83 300 mm Exhaust Fan Each 4 - 2,155.58 - 8,622.32
84 - -
Supply of following sizes of heavy duty Domestic exhaust fan for single phase 230 volt,
85 NSI-10 50HZ AC supply complete with motor, blades, frame, bracket, louver/ shutter etc as
required. - -
86 450 mm Exhaust Fan each 15 - 6,848.44 -
87 TOTAL CARRIED TO SUMMARY FOR SUBHEAD - II - -
88 SUBHEAD - III - MAIN BOARDS - -
Supplying, installing, testing & commissioning of following type compartmentalised wall
mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin
89 proof duly phosphatized & powder coated inclusive of suitable size 4 strip Al. Busbar
complete with interconnection providing Lugs, inter-earthing, painting etc. i/c providing &
fixing below noted accessories: - -
Receiving,unloading,storing, handling, installation, testing and commissioning of following
90 MV Switchboards complete as required and as per site condition and dimension of all
panels shall be carried out as per the attachad sld - -
91 - -
92 NSI-1 MAIN LT PANEL ( FOR BUILDING ) Set 1 - 1,50,800.00 - 1,50,800.00
93 - -
94 NSI-2 FIRE FIGHTING PANEL Set 1 - 40,000.00 - 40,000.00
95 - -
96 SUBHEAD - IV - DISTRIBUTION BOARDS - -
97 - -
Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess,
98 DSR 2.3 complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator) - -
3 1,231.66 - 3,694.98
Providing and fixing weather proof Fire Hose Cabinet of size not less than 0.75 x 0.6 x 0.25
mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm
thick glazed glass doors (Two nos.) suitably marked on the outside 'with the letters "FIRE
59 NS-2 35,562.00
HOSE" including necessary locking arrangement and painting in PO red colour suitable to
accommodate, external yard hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe,
nozzle and fire man's axe. It shall be mounted on boundary wall complete as required.
Each 3 - 11854.00 -
NS-3 Providing & fixing Controlled Percolating (CP) Hose ISI marked (IS:8423) 63 mm dia x 15 m
long complete with instantaneous type Stainless steel 63 mm dia ISI marked Male &
60 Female couplings (IS:903) bound and riveted to hose pipe with copper rivets and 1.5 mm 30,486.00
copper wire.brusting pressure not less than 22 Kg/Sqcm. ( Two nos. for each hydrant-
valve) Each 6 - 5081.00 -
61 - - -
62 NS-4 Providing and fixing standard firemans axe with heavy rubber handle. Each 3 - 1467.00 - 4,401.00
63 - - -
NS-5 Providing and fixing dial type pressure gauge with isolation cock and copper pipe on
64 41,496.00
main header Dial diameter 100 mm celebration 0-16 / sq. cm. Each 12 - 3458.00 -
NS-6 Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested -
single cast cylinder with rotary discharge valve and high pressure discharge tube of
65 minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished -
externally with red enamel paint and fixed to wall with brackets complete with internal
charge (Halon Free Gas) -
66 Capacity 4.5 Kg. Each 1 - 5647.00 - 5,647.00
NS-7 Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. -
cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage
67 internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, -
suspension bracket conforming to IS:15683 finished externally with red enamel paint and
fixed to wall with brackets complete with internal charge. (Halon Free Gas) -
68 Capacity 6.0 Kg. Each 14 - 4518.00 - 63,252.00
Total - 6,59,428 2,72,329
Supplying, installation, testing & commissioning fire alarm sounder with facility to make
7 DSR 17.1.6 Nos. 4 574.21 2,297 -
announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for
operation with amplifier i/c line matching transformer etc. complete as required. -
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with
8 DSR 17.5.2 annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer Mtrs 160 148.56 23,769 -
sheath complete as required. -
Supplying and fixing of following sizes of steel conduit along with accessories in
9 DSR 1.20 surface/recess including painting in case of surface conduit, or cutting the wall and making -
good the same in case of recessed conduit as required. -
10 DSR 1.20.2 25 mm Mtr 50 173.84 - 8,692 -
11 DSR 1.20.3 32 mm Mtr 10 213.88 - 2,139 -
Total - 59,788 87,288
NS
3 Supply of Flying bar Indian (Customised) with 1 ton chain pully Nos 1 - 18,500.00 - 18,500.00
NS Supply of Stage Monitor Supply of Stage monitor 2-way, bi-amp. bass reflex design,
400+100W rms Class D amp., 60Hz-20KHz freq resp, 12" B&C coax custom woofer, 1" B&C
4 47,100.00
HF driver, DSP 4 presets, 130dB SPL max, Disp 90°, gas-injection polyprop molded
enclosure (FBT-STAGEMAX x 12MA) Nos 1 - 47,100.00 -
NS Supply of Digital Audio mixer 24 mono mic inputs 4 line inputs 66 inputs to mix 1 ViSi
Connect™ option card slot for 64 x 64 input/output expansion Freely assignable faders and
patching Pre/Post selection per input per bus AES in and out Global mode encoders
5 Soundcraft FaderGlow™ GEQ on every bus 20 sub-group / aux busses 4 FX busses 8 Matrix 84,500.00
busses LR and C Mix busses 4 Stereo Lexicon Effects engines Delay on inputs and outputs 4
Mute Groups Freely assignable insert loops Harman HiQnet integration Colour touch
screen interface (Si Expersion-2)(Allen Heath QU 24) No. 1 - 84,500.00 -
6 NS Supply of Corded microphone (Shure-SM58/FBT/sennheiser) Nos 1 - 9,154.00 - 9,154.00
7 NS Supply of Instrument Microphone(Shure-57/FBT/sennheiser) Nos 1 - 9,678.00 - 9,678.00
8 NS Supply of Podium Microphone (Shure/FBT-GM5218L/AKG) Nos 1 - 13,411.00 - 13,411.00
9 NS Supply of Microphone Stand Big(GS) Nos 1 - 1,124.00 - 1,124.00
10 NS Supply of Microphone Stand Small(GS) Nos 1 - 843.00 - 843.00
NS Supply of microphone cable from stage to control room for microphone points with
11 26,331.00
conduit pipe etc. (PLS/Tasker/Krystal) Mtr 201 - 131.00 -
12 NS Supply of Speaker 2.5sqmm x3core(Incol/Polycab/Kalinga/Incoil) Mtr 95 - 114.00 - 10,830.00
NS Supply of microphone connecting box made out from CRC sheet metal box duly powder
13 coated paint,with 6 nos XLR panel mounting socket & phono socket having the facility to 8,644.00
connect the 6nos microphone channel. Nos 2 - 4,322.00 -
14 NS Supply of Professional Head phone(German Meastro/Sennheiser) Nos 1 - 7,081.00 - 7,081.00
15 NS Supply of Microphone cable XLR to XLR up to 10 Mtr(PLS) Nos 10 - 1,265.00 - 12,650.00
16 NS Supply of Microphone cable XLR to XLR up to 15 Mtr(PLS) Nos 10 - 1,861.00 - 18,610.00
17 NS Supply of Speaker connectin connector & MCB Box for Speaker etc Lot 1 - 33,254.00 - 33,254.00
18 NS Installation charges Job. 1 - 25,000.00 - 25,000.00
Total - - 6,00,000
Total - - 1,00,000
Construction of dry lean cement concrete sub base over a prepared sub-
grade with coarse and fine aggregate conforming to IS:383, the size of coarse
aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1,
aggregate gradation after blending to be as per specifications, cement
3 16.80 content not to be less than 150 Kg/cum, optimum moisture content to be cum 3.500 4148.65 14,520.28
determined during trial length construction, concrete strength not to be less
than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all
leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne
vibratory roller, finishing and curing etc. complete as per direction of
Engineer in- charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete
from batching plant. The ready mixed concrete shall be laid and finished with
screed board vibrator , vacuum dewatering process and finally finished by
floating, brooming with wire brush etc. complete as per specifications and
3 16.75 directions of Engineer-incharge. cum 4.375 9823.80 42,979.13
(The panel shuttering work shall be paid for separately).
(Note:- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/ recoverable
separately).
Providing and filling in position rubberized bitumen hot sealing compound Per cm
for sealing of expansion joints in roads / pavements all complete as per width
direction of the Engineer-in-Charge. per
4 16.46.1 Using grade 'A' sealing compound conforming to IS: 1834 cm 131.250 8.65 1,135.31
depth
per m
length
2.6
2 2.6.1 all kinds of soil Cum 9.45 177.50 1677.38
3
Providing and laying in position cement concrete of specified
4 grade excluding the cost of centering and shuttering. All work
upto plinth level.
1:5:10 (1 cement : 5 course bound: 10 graded stone
5
4.1.10 aggregate 40mm nominal size) Cum 9.75 6518.60 63556.35
6
7
16.68 Providing and laying 60mm thick faciory made cement
concrete interlocking paver block of M -30 grade made by
block making machine with strong vibratory compaction, of
8 approved s;ze, design & shape, laid in required colour and
pattern over and including 50mm thick compacted bed of
coarse sand, filling the joints with line sand etc. all complete as
per the direction of Engineer-in-charge.
Cum 89.40 972.00 86896.80
9
Providing and laying at or near ground level factory made kerb
stone of M-25 grade cement concrete in position to the
required line, level and curvature, jointed with cement mortar
1:3 (1 cement: 3 coarse sand), ncluding making joints with or
without grooves (thickness of joints except at sharp curve shall
10 not to more than 5mm), including making drainage opening
wherever required complete etc. as per direction of Engineer-
in-charge (length of finished kerb edging shall be measured for
payment). (Precast C.C. kerb stone shall be approved by
Engineer-in-charge).
16.69 Cum 4.00 10177.60 40710.40
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame
(light duty) 455x610 mm internal dimensions,total weight of cover and
9 19.7.1 frame to be not less than 38 kg (weight of cover 23 kg and weight of
frame 15 kg) :
Amount
Rate (DSR- Rate DSR- Amount (DSR-
DSR- NS Rate (DSR NS AMOUNT (In
S.N. DESCRIPTION OF ITEM UNIT QUANTITY 2023) 2022 + GST 2023)
2023 (In ₹) 2022+GST ₹)
(In ₹) 5.36% (In ₹)
5.36%)
With common burnt clay F.P.S.(non modular) bricks of class designation
10 19.7.1.1 7.5
EACH 8 12770.55 102164.4
11
Constructing brick masonry road gully chamber 45x45x77.5 cm with
12 19.28 bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast
R.C.C. vertical grating complete as per standard design :
with common burnt clay F.P.S.(non module) brick of class designation
13 19.28.1
7.5 EACH 12 6889.8 82677.6
14
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff
15 19.1 mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine
sand) including testing of joints etc. complete :
16 19.1.2 150 mm dia (NP-2) EACH 130 695.8 90454
17
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :
10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes
18 19.2 including bed concrete as per standard design :
Amount
Rate (DSR- Rate DSR- Amount (DSR-
DSR- NS Rate (DSR NS AMOUNT (In
S.N. DESCRIPTION OF ITEM UNIT QUANTITY 2023) 2022 + GST 2023)
2023 (In ₹) 2022+GST ₹)
(In ₹) 5.36% (In ₹)
5.36%)
Making connection of drain or sewer line with existing manhole
including breaking into and making good the walls, floors with cement
concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate
23 19.21 20 mm nominal size) cement plastered on both sides with cement
mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of
neat cement and making necessary channels for the drain etc. complete
:
For pipes 100 to 250 mm diameter EACH 1 810.45
24 19.21.1
810.45
25
Constructing brick masonry circular type manhole 0.91 m internal
dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement
: 4 coarse sand), inside cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat
of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse
26 19.9
sand : 6 graded stone aggregate 40 mm nominal size), and making
necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size) finished
with a floating coat of neat cement, all complete as per standard
design :
0.91 m deep with SFRC cover and frame (heavy duty, HD-
20 grade designation) 560 mm internal diameter conforming
to I.S. 12592, total weight of cover and frame to be not
less than 182 kg., fixed in cement concrete 1:2:4 (1 cement
27 19.9.1
: 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12mm thick cement plaster at
the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) EACH 1 12725 12725
28 19.9.1.1
bricks of class designation 7.5
29 TOTAL OF SUB HEAD - IV 3,96,598.56 - -
DSR- Rate (DSR- Rate DSR- NS Rate Amount (DSR- Amount (DSR NS AMOUNT (In
S.N. DESCRIPTION OF ITEM UNIT QUANTITY 2023) 2022 + GST 2023)
2022 (In ₹) 2022+GST 5.36%) ₹)
(In ₹) 5.36% (In ₹)
EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonary enclosure with cover plate having locking
1 DSR 5.4 Sets
arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke
and salt as required. 1 7,872.50 7,872.50
-
Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including
accesssories, and providing masonary enclosure with cover plate (CI heavy duty)
2 DSR 5.6 Sets
having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with
charcoal or coke and salt) as required. 1 14579.72 14,579.72
-
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth
3 DSR 5.11 electrode, including connection with G.I. nut, bolt, spring, washer excavation and Mtr
refilling etc. as required. 20 743.84 14,876.83
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for
4 DSR-5.14 connections etc. as required. 2 nos used for 50 x 5 for the Neutral earthing of Mtr
euipments ) 20 1,224.28 24,485.66
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for
5 DSR 5.15 connections etc. as required. Mtr
20 257.08 5,141.57
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing
6 DSR 5.16 etc. as required. Mtr
20 73.75 1,475.04
-
Supply and laying medium class GI pipe under road/paved areas/wall crossing etc.
8 NSI-2 including earth excavations refilling, ramming and making good as approved.
-
150 mm dia GI pipe Class B
8.1 NSI-2.1 Metre
10 - 1,600.00 16,000.00
TOTAL
- 68,431.32 16,000.00
-
L.T. CABLES
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
KV grade of following size direct in ground including excavation, sand cushioning,
1 DSR 7.1
protective covering and refilling the trench etc. as
required.
External Lights
Supplying, installation, testing and commissioning of 65W LED Street Light IP66
LED with High performance having system lumen output of minimum 9900
lumens, contemporary designed housing made of die-cast aluminium, with street
1 NSI-1 Nos
optic LENS for uniform light distribution. PF better than 0.9, CRI better than 70
complete with all accessories. Wipro Cat No.: LR 02-102-XXX-57-G2 Street light
4 - 7,634.33 30,537.32
SITC of 6m ht. GI pole alongwith control box,6A MCB etc. as required for St. height
2 NSI-2 Nos
4 - 10,000.00 40,000.00
Total - - 70,537.32