19U(C)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Pressure Sensors

Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series


FEATURES
• Low cost
• Rugged, isolated stainless
steel package
• Small size
• Reliable semiconductor
technology
• Calibrated and
temperature compensated
• Absolute and gage
pressures
• Vacuum compatible, Honeywell’s stainless steel 19C, 19U, and 19 Vacuum Gage Series
isolated sensors sensors were developed for pressure applications that involve measurement
• 0 psi to 3 psi to, 0 psi to of hostile media in harsh environments compatible with 316 stainless steel.
500 psi The special Vacuum Gage Series sensors are specifically designed for
applications that can be exposed to vacuum.
The 19C Series are calibrated and temperature compensated. They are
TYPICAL APPLICATIONS available for use with either a constant voltage or current source. They
• Industrial controls feature a variety of pressure connections to allow use in a wide range of
• Process control systems OEM (Original Equipment Manufacturer) equipment. The 19U Series is
• Industrial automation and uncompensated for applications that use their own specialized circuit
flow control designs.
• Pressure calibrators The 19C and 19U Series sensors are rugged and reliable transducers for
use in a wide variety of pressure sensing applications where corrosive
liquids or gases are monitored.

19C, 19U, AND 19 VACUUM GAGE EQUIVALENT CIRCUIT

WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product WARNING
could result in personal MISUSE OF DOCUMENTATION
injury. • The information presented in this product sheet is for reference only. Do
Failure to comply with not use this document as a product installation guide.
these instructions could • Complete installation, operation, and maintenance information is provided
result in death or serious in the instructions supplied with each product.
injury. Failure to comply with these instructions could result in death or
serious injury.

Sensing and Control


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
PRESSURE SENSOR CHARACTERISTICS – ALL DEVICES
Environmental specifications
Compensated temperature range 0 °C to 82 °C [32 °F to 180 °F]
Operating temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Storage temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
Insulation resistance 100 mΩ at 50 Vdc
Maximum ratings
Voltage version “K” Supply voltage VS = +15 Vdc
Voltage version “L” Supply current IS = +2.0 mA

PRESSURE RANGE SPECIFICATIONS (19C, 19U)


Catalog Listing Pressure range Proof pressure Burst pressure
(7) (8)

19(C,U) 003P G (1…9) (K/L) 0 psig to 3 psig 9 psig 15 psig


19(C,U) 005P G (1…9) (K/L) 0 psig to 5 psig 15 psig 25 psig
19(C,U) 010P G (1…9) (K/L) 0 psig to 10 psig 30 psig 50 psig
19(C,U) 015P (A,G,V) (1…9) (K/L) 0 psi to 15 psi 45 psi 75 psi
19(C,U) 030P (A,G,V) (1…9) (K/L) 0 psi to 30 psi 90 psi 150 psi
19(C,U) 050P (A,G,V) (1…9) (K/L) 0 psi to 50 psi 150 psi 250 psi
19(C,U) 100P (A,G,V) (1…9) (K/L) 0 psi to 100 psi 300 psi 500 psi
19(C,U) 200P (A,G,V) (1…9) (K/L) 0 psi to 200 psi 600 psi 1000 psi
19(C,U) 300P (A,G,V) (1…9) (K/L) 0 psi to 300 psi 900 psi 1500 psi
19(C,U) 500P (A,G,V) (1…9) (K/L) 0 psi to 500 psi 1200 psi 2400 psi
Notes:
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8.The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case.

19C SERIES PERFORMANCE CHARACTERISTICS


(1)

Characteristic Minimum Typical Maximum Unit


Zero pressure offset -2 0 2 mV
(2)
Full-scale span 98 100 102 mV
(2)
Full-scale span (3 psi and 5 psi “K” units only) 48 50 52 mV
(3)
Pressure non-linearity – ±0.1 ±0.25 %FSS
(3)
Pressure hysteresis – ±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
(4)
Temp. effect on span – ±0.5 ±1.0 %FSS
(4)
Temp. effect on offset – ±0.5 ±1.0 %FSS
(4)
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) – – ±2.0 %FSS
(4)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) – – ±2.0 %FSS
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) – ±0.1 ±0.3 %FSS
(5)
Long-term stability of offset and span – ±0.1 ±0.3 %FSS
(6)
Response time – 0.1 – ms
(9)
Common mode voltage (voltage version “K”) 0.5 1.3 2.0 Vdc
Input impedance (current version “L”) 2.0 4.5 8.0 kΩ
Input impedance (voltage version “K”) 8.0 25 50 kΩ
Output resistance 3.0 4.5 6.0 kΩ

2 Honeywell • Sensing and Control


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
19U SERIES PERFORMANCE CHARACTERISTICS
(1)

Characteristic Minimum Typical Maximum Unit


Zero pressure offset -7.5 1.0 7.5 mV/V
(2)
Full-scale span 35 40 60 mV/V
(2)
Full-scale span (3 psi and 5 psi only) 20 30 40 mV/V
(3)
Pressure non-linearity – ±0.1 ±0.25 %FSS
(3)
Pressure hysteresis – ±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
(10)
Temp. coefficient of resistance (0 °C to 82 °C [32 °F to 180 °F]) 2700 3420 4500 ppm/°C
µV/V/°C
(10)
Temp. coefficient of offset (0 °C to 82 °C [32 °F to 180 °F]) – 30 –
(10)
Temp. coefficient of span (0 °C to 82 °C [32 °F to 180 °F]) 360 720 1260 ppm/°C
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) – ±0.1 ±0.3 %FSS
(5)
Long-term stability of offset and span – ±0.1 ±0.3 %FSS
(6)
Response time – ±0.1 – ms
Input resistance 4.00 4.75 6.0 kΩ
Output resistance 4.00 4.75 6.0 kΩ

19C VACUUM GAGE COMPENSATED SERIES PERFORMANCE CHARACTERISTICS


(1)

Characteristic Minimum Typical Maximum Unit


Zero pressure offset (at 0 psig) -2 0 2 mV
(2)
Full-scale span (0 psig to positive full-scale) 98 100 102 mV
(3)
Pressure non-linearity – ±0.1 ±0.25 %FSS
(3)
Pressure hysteresis – ±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
(4)
Temp. effect on span – ±0.5 ±1.0 %FSS
(4)
Temp. effect on offset – ±0.5 ±1.0 %FSS
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) – ±0.1 ±0.3 %FSS
(5)
Long-term stability of offset and span – ±0.1 ±0.3 %FSS
(6)
Response time – 0.1 – ms
(9)
Common mode voltage (voltage version “K”) 0.5 1.3 2.0 Vdc
Input impedance (current version “L”) 1.5 4.5 8.0 kΩ
Input impedance (voltage version “K”) 8.0 25 50 kΩ
Output resistance 3.0 4.5 6.0 kΩ

19U VACUUM GAGE UNCOMPENSATED SERIES PERFORMANCE CHARACTERISTICS


(1)

Characteristic Minimum Typical Maximum Unit


Zero pressure offset -7.5 1.0 7.5 mV/V
(2)
Full-scale span (0 psig to positive full-scale) 35 40 60 mV/V
(3)
Pressure non-linearity – ±0.1 ±0.25 %FSS
(3)
Pressure hysteresis – ±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
(10)
Temp. coefficient of resistance (0 °C to 82 °C [32 °F to 180 °F]) 2700 3420 4500 ppm/°C
µV/V/°C
(10)
Temp. coefficient of offset (0 °C to 82 °C [32 °F to 180 °F]) – 30 –
(10)
Temp. coefficient of span (0 °C to 82 °C [32 °F to 180 °F]) 360 720 1260 ppm/°C
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) – ±0.1 ±0.3 %FSS
(5)
Long-term stability of offset and span – ±0.1 ±0.3 %FSS
(6)
Response time – ±0.1 – ms
Input resistance 4.00 4.75 6.0 kΩ
Output resistance 4.00 4.75 6.0 kΩ

Honeywell • Sensing and Control 3


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; 19C Supply VS = 10 Vdc ±0.01 Vdc or
IS = 1.5 mA ±0.0015 mA; 19U Supply VS = 5 Vdc ±0.01 Vdc or I = 1.0 mA ±0.0015 mA
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
9. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
10. The error band resulting from a maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
temperature is varied 25 °C [77 °F] to any other temperature within the specified range (0 °C to 82 °C [32 °F to 180 °F]).
This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only.
Temperature coefficient of span is evaluated using a constant current source.

PHYSICAL DIMENSIONS, for reference only, mm [in]

Package 1 (see note): Cell Package

Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower portions of
the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).

Package 2: Flush Mount Package

4 Honeywell • Sensing and Control


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
Package 3: Flush Mount with Flange

Package 4: Male 1/8-27 NPT

Package 5: Male 1/4-18 NPT

Honeywell • Sensing and Control 5


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
Package 6: Male 7/16 UNF

Package 7: Male 1/4 BSPP

Package 8: Euro Ring (See note)

Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and
lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-
concentricity).

6 Honeywell • Sensing and Control


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
Package 9: VCR Gland (Female nut)

ORDERING INFORMATION

Honeywell • Sensing and Control 7


Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors 19 mm Series
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as While we provide application assistance personally,
being free of defective materials and faulty through our literature and the Honeywell web site, it
workmanship. Contact your local sales office for is up to the customer to determine the suitability of
warranty information. If warranted goods are the product in the application.
returned to Honeywell during the period of coverage, For application assistance, current specifications, or
Honeywell will repair or replace without charge those name of the nearest Authorized Distributor, contact a
items it finds defective. The foregoing is Buyer’s nearby sales office. Or call:
sole remedy and is in lieu of all other warranties, 1-800-537-6945 USA/Canada
expressed or implied, including those of 1-815-235-6847 International
merchantability and fitness for a particular FAX
purpose. 1-815-235-6545 USA
Specifications may change without notice. The INTERNET
information we supply is believed to be accurate and www.honeywell.com/sensing
reliable as of this printing. However, we assume no [email protected]
responsibility for its use.

Sensing and Control


www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032

008132-1-EN IL50 GLO 1004 Printed in USA


Copyright 2004 Honeywell International Inc. All Rights Reserved.

You might also like