PRODUCT DATA SHEET
Sikagard®-63 N
2-PART EPOXY PROTECTIVE COATING
DESCRIPTION SUSTAINABILITY
Sikagard®-63 N is a two part, rigid, total solid, col- According USGBC LEED Rating Sikagard®-63 N con-
oured epoxy resin based protective coating. forms to the requirements of LEED EQ Credit 4.2: Low
Suitable for use in hot and tropical climates. – Emitting Materials: Paints & Coatings SCAQMD
Method 304-91 VOC Content < 100 g/l
USES
APPROVALS / CERTIFICATES
Sikagard®-63 N may only be used by experienced pro-
fessionals. Coating for concrete protection according the require-
▪ Chemical resistant protective layer on concrete, ments of EN 1504-2/2004, DoP
stone, cementitious mortars and renderings, epoxy 0206060100300000011008, certified by FPC Notified
cement, epoxy resin based products and steel Body and provided with CE-Marking
▪ Lining in storage tanks and silos
▪ Anti-corrosion coating on steel in food processing
plants, sewage works, farms, agricultural enterprises,
chemical and pharmaceutical facilities and beverage
industry
CHARACTERISTICS / ADVANTAGES
▪ Solvent free
▪ Good mechanical and chemical resistance
▪ High build
▪ Impervious to liquids
▪ Easy to mix and to apply
PRODUCT INFORMATION
Composition Epoxy resin
Packaging Part A 8.70 kg container
Part B 1.3 kg container
Part A + B 10 kg ready to mix unit
Appearance / Colour RAL 7032 (pebble grey), other on request
Shelf life 12 month from date of production
Product Data Sheet
Sikagard®-63 N
November 2016, Version 01.01
020606010030000001
1/3
Storage conditions The packaging must be stored properly in original, unopend and undam-
aged sealed packaging, in dry conditions at temperatures between +5 °C
and +30 °C. Protected from direct sunlight.
Density Mixed resin ~1.35 kg/l (EN ISO 2811-1)
Density values determined at +23 °C
Solid content ~100 %
TECHNICAL INFORMATION
Tensile Adhesion Strength > 1.5 N/mm2 to concrete (ISO 4624)
> 15 N/mm2 to steel (EN 24624)
> 10 N/mm2 to aluminium (EN 24624)
Chemical Resistance For further information please contact Sika Technical Department.
Temperature Resistance Exposure Dry heat
Permanent +40 °C
Max. 3 days +60 °C
Diffusion Resistance to Water Vapour µH2O ~100 000 (EN ISO 7783-1)
APPLICATION INFORMATION
Mixing Ratio Part A : Part B = 83 : 17 by weight
Consumption ~0.15 kg/m² per layer
Layer Thickness ~0.1 mm per layer
Ambient Air Temperature +10 °C min. / +35 °C max.
Relative Air Humidity < 80 %
Substrate Temperature +10 °C min. / +40 °C max.
≥ 3 °C above dew point, beware of condensation
Pot Life Temperature Time
+10 °C ~30 min
+20 °C ~20 min
+30 °C ~10 min
Waiting Time / Overcoating Temperature Minimum Maximum Full Cure
+10 °C 9h 3d 14 d
+20 °C 5h 2d 9d
+30 °C 4h 1d 5d
APPLICATION INSTRUCTIONS This product may only be used by experienced profes-
sionals. Do not apply Sikagard®-63 N on moist sub-
Prior to mixing stir part A mechanically. When all of strates. Sag resistance on vertical surface is < 100 μm.
part B has been added to part A mix continuously for 3 Sikagard®-63 N cannot be used to produce glass fibre
minutes until an uniform mixed has been achieved. reinforced linings. Freshly applied Sikagard®-63 N must
Use a low speed electrical stirrer (300 to 400 rpm) to be protected from rain, condensation and water for at
avoid air entrapment. To ensure proper mixing pour least 24 hours. For exact colour matching ensure the
material into a clean container and stir again. Apply by use the same control batch numbers.
brush, short piled roller or airles spray.
BASIS OF PRODUCT DATA
CLEANING OF EQUIPMENT
All technical data stated in this Data Sheet are based
Clean all tools with Thinner C immediately after use. on laboratory tests. Actual measured data may vary
Hardened and/or cured material can only be removed due to circumstances beyond our control.
mechanically.
LOCAL RESTRICTIONS
IMPORTANT CONSIDERATIONS
Note that as a result of specific local regulations the
Product Data Sheet
Sikagard®-63 N
November 2016, Version 01.01
020606010030000001
2/3
declared data and recommended uses for this product
may vary from country to country. Consult the local
Product Data Sheet for the exact product data and
uses.
ECOLOGY, HEALTH AND SAFETY
For information and advice on the safe handling, stor-
age and disposal of chemical products, users shall refer
to the most recent Safety Data Sheet (SDS) containing
physical, ecological, toxicological and other safety-re-
lated data.
LEGAL NOTES
The information, and, in particular, the recommenda-
tions relating to the application and end-use of Sika
products, are given in good faith based on Sika's cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika's recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.
SIKA NORTHERN GULF SIKA SOUTHERN GULF SIKA SAUDI ARABIA
Bahrain / Qatar / Kuwait UAE / Oman / SIC Riyadh / Jeddah / Dammam
Tel: +973 177 38188 Tel: +971 4 439 8200 Tel: +966 11 217 6532
[email protected] [email protected] [email protected]gcc.sika.com gcc.sika.com gcc.sika.com
Sikagard-63N-en-AE-(11-2016)-1-1.pdf
Product Data Sheet
Sikagard®-63 N
November 2016, Version 01.01
020606010030000001