VT9 VT92
VT9 VT92
Applications
Varifix thermostats are designed especially to facilitate the replacement of refrigeration controllers on site.
The model indicates the typical intended use.
Common features
Electrical rating: 6A inductive at 250V~ (VW8 16A inductive at 250V~) VS5/VR6 0,1A signal contacts.
specifications
Part
Model Application capillary cold cold warm warm terminals packaging
number defrost signal
mm cut-out cut-in cut-out cut-in faston (mm) (pcs/box)
VC1 K50P1110 1 door refrigerator 1200 -23.5 -14.5 2 6.3 50
VC101 K50H1104 1 door refrigerator 1200 -22.5 -5 2 4.8 80
VC110 K50H1108 bottle refrigerator 2000 -12 -4 4 4.8 80
VA2 K50P1174 absorption refrigerator 2000 -18 -14.5 3.5 6.3 50
VA102 K50H1105 absorption refrigerator 1200 -18 -14.5 3.5 4.8 80
freezer no signal, 2000 -34 -16.5 -12 6.3 50
VF3 K50P1117
ice cream cabinet
freezer no signal, 2000 -32 -16.5 -12 4.8 80
VF103 K50H1106
ice cream cabinet
1 door refrigerator with 1200 -25 -10 -4 5.5 6.3 50
VP4 K60P1013
manual defrost
1 door refrigerator with 1600 -19 -11 -1 7.5 4.8 50
VP104 K60L2024
manual defrost
2 door refrigerator with 1500 -31 -13 -5 5 4.8 50
VP111 K60L2025
manual defrost
2000 -34 -16.5 -12 5° (above 6.3 50
VS5 K54P1102 freezer with active signal warm
cut-in)
2000 -34 -16.5 -12 5° (above 4.8 80
VS105 K54H1404 freezer with active signal warm
cut-in)
2000 -34 -16.5 -12 5° (above 6.3 50
VR6 K54P3100 freezer with passive signal warm
cut-in)
2000 -32 -20 -15 5° (above 4.8 80
VR106 K54H3400 freezer with passive signal warm
cut-in)
liquid refrigerator, 1200 -3 2 12.5 6.3 50
VB7 K50P1118
bottle refrigerator
liquid refrigerator, 2000 -3 2 12.5 4.8 80
VB107 K50H1107
bottle refrigerator VA VF VS5 VR6
VT9 K59L1102 2 door refrigerator 1200 -26 3.5
VB VG -11 3.5 6.3 50
VC VW
VT93 K59P1662 2 door refrigerator 3000 -26 3.5 -11 3.5 6.3 50
VI109 K59H1303 2 door refrigerator 2000 -21 4.5 -6.5 4.5 6 4.8 80
6
Circuit Options
(Heater on VA2) Control with “OFF” Control with “OFF” using Control with Heater & Relay
position for Heater Assisted Defrost Controlling
Heat Leakage Defrost Compressor and By-pass Valve