Checklist For Design Team - XLSX - Checklist
Checklist For Design Team - XLSX - Checklist
Having executed over 250 homes we are proud to share our knowledge and experience that will help you during design. Kindly note the following points for a
hassle free design and build experience
Area Description Type Alternate solution
Wooden laminates on the expo side in wardrobe with loft , it gets difficult to match the grains from the floor to
Wardrobe F2C ceiling
If we use lacquered glass for wardrobe door,after every 5 ft a
Wardrobe profile divider is considered for stability
For Inline sliding wardrobe,front patta height ( to hide the
Wardrobe mechanism)is 80mm
Depth of inline sliding wardrobe carcass will be 600mm + These to be reflected in the plan of respective units and
Wardrobe 20mm front patta. Total 620 depth SKU's will be updated as well
Wardrobe If the internal shutter opening of mirror pullout is towards a Mirror will hit the handle and break.Kindly don't
handle sliding wardrobe which has eph handle, suggest the same.
45mm profile for sliding wardrobe shutters maximum height
Wardrobe should be 7' because of high maintenanace.
There is 2 drawers and lock need to provide for both of the
Wardrobe drawers Top ply between to be provided for the lock system.
Towerbolt for specific client to be discussed if the wardrobe
Wardrobe height is more than 7ft
Wardrobe Inlay Mechanism : sides internal laminate white shown in GFC
F2C wardrobe The costing may vary depending on the shutter design.
the costing is given by sales team is for standard design
,i.e. 3 partition design in shutter with fully lacquered or
in between mirror (same as in our EC) ,if patterns are
more than 3 division or some different customized
Wardrobe design the costing to be checked
Handle Edge profile handle is being used There will be shutter gap,mention in drawings
Handle Mirror pull out internal shutter handle selection shown in GFC
min filler width of 70mm has to be considered for easy
Handle When Eph handles used in Kitchen corner units opening
Incase client insists on horizontal placement for
shutters,it has to be fixed in the edge for easy access .
Handle Handle placement is vertical for shutters. Kindly mention the same in 3d and 2d.
Handle Handle position to be indicated in gfc for dual lift up shutters
Tall unit with single door can be done only if pantry pullout is
used.
Handle G profile and gola profile is Not used
Incase client insists on horizontal placement for
shutters,it has to be fixed in the edge for easy access .
Handle Handle placement for drawers is horizontal Kindly mention the same in 3d and 2d.
EPH handles can not be installed for inline sliding door,if
provided the opening of shutter will be difficult.Bi - Fold Hinge
Handle not to be used
Handle Pull out table Handle need to discuss with client during design stage.
Loft shutter height 800mm is maximum Remaining space we need to consider filler .
All units standard internal laminate will be white including Additional costing to be done for premium internal
Laminates pooja and glass units. laminate (B CATEGORY LAMINATE)
In one shutter there should not be more than two
Laminate Shutter design- Horizontal laminate joining joining.
In one shutter there should not be more than two
Laminate Shutter design - vertical laminate joining joining.
Designing to be done considering laminate wastage.Thumb Cutlist team will review first 3 projects of each designer
rule-90% of laminate usage and 10% wastage is good to go. before sharing costing to help them to understand the
Laminate Additional charges for laminate to be done accordingly. optimisation.
Wooden,patterned laminates will incurr more wastage than
solid laminates.Kindly suggest according to client requirement
Laminate and budget
Laminates Solid color laminates used more in projects, for better optimisation
Restriction on number and type of Laminates used for 2bhk
Laminates and 3bhk
Chandelier selection done Chandelier plate will be fixed to the ply framework as
the gypsum won't be able to hold it.Boxing dimensions
will vary as per light and the client needs to do the
selections prior and the same needs to be mentioned
False ceiling in false ceiling drawings.
Additional charges will be incurred for cutting to
False ceiling Concealed lights in false ceiling accomodate concealed profile light.
For 45mm Profile frame wardrobe 6mm mdf will be used for
Profile frame shutter shown in GFC
45 mm thick profile shutter for sliding doors will be having
6mm thick mdf with laminate is used,with 10 mm front look,5
mm groove to place 6 mm mdf,
in this case using only laminate will make the shutter less
weight (whereas opening the shutter need more force),so
Profile shutter laquered glass or mirror to be suggested to client .
Costing Polishing to be done for grooving in panelling. Additional charges for the same
If you are using this in your design, kindly mention in
Costing Glass door hinge - Overlay soft close. the gfc!
Costing Pooja Backlit panelling Kindly consider acrylic sheet
Additional charges will be applicable for fixing decorative Only fixing of spot lights,cove lights and profile lights
Costing lights. will be added by default in the electrical quote-
165 degree hinges are available with soft close and needs to be
Costing charged accordingly
Costing Additional drawers/ tray in puja unit costed
Costing Internal Ply organsier used Suggest readymade organiser with standard size.
Pooja Door Should not have om or any religious idols cutting
Pooja Unit in to half (In two Doors) Each door should complete Design