Dear Designer

Having executed over 250 homes we are proud to share our knowledge and experience that will help you during design. Kindly note the following points for a
hassle free design and build experience
Area Description Type Alternate solution
Wooden laminates on the expo side in wardrobe with loft , it gets difficult to match the grains from the floor to
Wardrobe F2C ceiling
If we use lacquered glass for wardrobe door,after every 5 ft a
Wardrobe profile divider is considered for stability
For Inline sliding wardrobe,front patta height ( to hide the
Wardrobe mechanism)is 80mm
Depth of inline sliding wardrobe carcass will be 600mm + These to be reflected in the plan of respective units and
Wardrobe 20mm front patta. Total 620 depth SKU's will be updated as well
Wardrobe If the internal shutter opening of mirror pullout is towards a Mirror will hit the handle and break.Kindly don't
handle sliding wardrobe which has eph handle, suggest the same.
45mm profile for sliding wardrobe shutters maximum height
Wardrobe should be 7' because of high maintenanace.
There is 2 drawers and lock need to provide for both of the
Wardrobe drawers Top ply between to be provided for the lock system.
Towerbolt for specific client to be discussed if the wardrobe
Wardrobe height is more than 7ft
Wardrobe Inlay Mechanism : sides internal laminate white shown in GFC
F2C wardrobe The costing may vary depending on the shutter design.
the costing is given by sales team is for standard design
,i.e. 3 partition design in shutter with fully lacquered or
in between mirror (same as in our EC) ,if patterns are
more than 3 division or some different customized
Wardrobe design the costing to be checked

Kitchen Counterop/wall mounted sink


Kitchen Tap in the center of the sink
Preferable skirting-PVC, decision can be taken as per site
Skirting conditions
Standard depth of a wall unit is 300 + 20 mm.
Wall cabinet
Normal lift up- shutter height for flap down shutters to be at
Flap down 325 mm Soft close hinges is mandatory and should be charged
Normal lift up- Shutter height for normal lift up mechanism
Lift up should be min 325mm
Advanced lift up- Shutter height for flap down mechanism
Lift up should be min 400mm
and they will charge additional for 40mm.Kindly keep
Kitchen Builder will provide 20mm granite by default the clients informed
Kitchen has cement platform finished
Kitchen with tiles. Ply skirting need not be given in the design
Even if the selections are not done,suggestions made
for that space can be mentioned in gfc to avoid
escalations in the future, ELSE DISCLAIMER HAS TO BE
Kitchen Kitchen appliances model details mentioned in gfc. MENTIONED IN GFC
Sizes to be considered according to chimney
Kitchen Chimney pelmet is made openable. dimensions
Placement of Sockets for OTG and microwave planned
Kitchen considering appliance dimensions with modular standards
Corner unit sizes should be as per standards(Ex 1050,1100
mm). Min Shutter width 450mm if we are using any There can be a gap near the wall if there are space
Kitchen mechanisms. constraints.
If there is a column offset in kitchen,depth of the units in that but feasibility of fixing a particular accessory to be
Kitchen area is reduced considered if any
Utilitsation space available for cutlery drawers will be
lesser than standard. Kindly keep the client informed.
Suggestion to place the 3 drawers(cutlery,thali) to the
right side of hob unit can be made for easy access and
Kitchen If client is going ahead with built in hob optimum space
Existing platform sectional drawings and overall dimensions
Kitchen mentioned in the drawings
Checklist for kitchen gfc: Details of Microwave,RO,Sink,Hob
and Chimney to be mentioned in gfc as per the selections
Kitchen made
Bush to be provided by default to manage the
Kitchen Dimensions of existing platform if any mentioned in the gfc's. undulations
Internal shelf depth will be as per standard not
150mm, 50mm filler still needs to be given on top if the
Kitchen Double lift up mechanism to be used from Blum/Everyday loft depth is more than the wall unit.
50mm filler given on top if the loft depth is more than the
Kitchen wall unit.
Advance double lift up -from hettich should not to be used for
Kitchen corner unit
If double lift up is provided below loft(if loft is projecting out
of wall unit), dummy of 50 mm to be provided. Hettich
advance double lift up is not available for glass shutter,
Kitchen Everyday lift up can be used as an alternative.
Kitchen Hettich advance double lift up is not available for glass shutter Everyday lift up can be used as an alternative.
Tandem with gallery rod to be suggested for better stability
Kitchen for 300mm drawers Costing to be done accordingly
Rest of the shutters have to be glass in Al profile to
Kitchen Wooden shutter for a tall unit for pantry pullout. avoid bending issues
Depth of the units in that area can be reduced but
feasibility of fixing a particular accessory to be
Kitchen If there is a column offset in kitchen considered if any
Sink unit bottom cabinet ply wont be provided due to
plumbing leakage ,
-condition A)-if there is concrete bed-no bottom ply is
provided.
Kitchen
Sink unit bottom cabinet ply wont be provided due to
plumbing leakage ,

-condition B)-if there is no concrete bed and sink outlet is on


floor-no bottom ply is provided.
Kitchen
Sink unit bottom cabinet ply wont be provided due to
plumbing leakage ,

-condition C)-if there is no concrete bed and sink outlet is on


wall- bottom ply is to be provided.
Kitchen
Kitchen : Bottom and wall cabinet considered soft close
Kichen hinges and channels.
Motion drawers for grain pull out will hold 65 kg , godrej and
Kichen ebco brand used
Wicker Branded Wicker basket 600mm and 500 mm width available
Wicker Non Branded wicker basket 450mm and 600mm width available
Additional costing to be done for premium internal
Wicker Wicker basket unit- internal laminate will be white by default laminate,additional ply and liner
Lift up in wall unit(in case of loft depth more that wall unit) -
1)gas spring lift up can be used.
Lift up
Lift up in wall unit(in case of loft depth more that wall unit) -
2)Advance double lift up can be used only if there is 50 mm
Lift up filler in between loft bottom and wall cabinet

Handle Edge profile handle is being used There will be shutter gap,mention in drawings
Handle Mirror pull out internal shutter handle selection shown in GFC
min filler width of 70mm has to be considered for easy
Handle When Eph handles used in Kitchen corner units opening
Incase client insists on horizontal placement for
shutters,it has to be fixed in the edge for easy access .
Handle Handle placement is vertical for shutters. Kindly mention the same in 3d and 2d.
Handle Handle position to be indicated in gfc for dual lift up shutters
Tall unit with single door can be done only if pantry pullout is
used.
Handle G profile and gola profile is Not used
Incase client insists on horizontal placement for
shutters,it has to be fixed in the edge for easy access .
Handle Handle placement for drawers is horizontal Kindly mention the same in 3d and 2d.
EPH handles can not be installed for inline sliding door,if
provided the opening of shutter will be difficult.Bi - Fold Hinge
Handle not to be used
Handle Pull out table Handle need to discuss with client during design stage.
Loft shutter height 800mm is maximum Remaining space we need to consider filler .

All units standard internal laminate will be white including Additional costing to be done for premium internal
Laminates pooja and glass units. laminate (B CATEGORY LAMINATE)
In one shutter there should not be more than two
Laminate Shutter design- Horizontal laminate joining joining.
In one shutter there should not be more than two
Laminate Shutter design - vertical laminate joining joining.
Designing to be done considering laminate wastage.Thumb Cutlist team will review first 3 projects of each designer
rule-90% of laminate usage and 10% wastage is good to go. before sharing costing to help them to understand the
Laminate Additional charges for laminate to be done accordingly. optimisation.
Wooden,patterned laminates will incurr more wastage than
solid laminates.Kindly suggest according to client requirement
Laminate and budget
Laminates Solid color laminates used more in projects, for better optimisation
Restriction on number and type of Laminates used for 2bhk
Laminates and 3bhk
Chandelier selection done Chandelier plate will be fixed to the ply framework as
the gypsum won't be able to hold it.Boxing dimensions
will vary as per light and the client needs to do the
selections prior and the same needs to be mentioned
False ceiling in false ceiling drawings.
Additional charges will be incurred for cutting to
False ceiling Concealed lights in false ceiling accomodate concealed profile light.

Mirror L cut mirror it is difficult during excecution.


Plain mirror and glass costed in
Mirror multiples of 6 inches
Tinted mirror and glass costed in
Glass multiples of 1'
Mirror 75mm border provided for mirror on shutter panel To fix hinges
Mirror Additional internal drawer- 18mm top ply for lock support.
Height of mirror behind wardrobe shutter is not be more than
Mirror 5'. Bending issues
Back ply panel is mandatory for all mirror panels as mirror will
break if its fixed only with studs.Costing needs to be done for
Mirror the same.
Installation suggested in mirror stickering method
Mirror Criss cross Mirror Panelling instead of etching
Mirror For bevelled mIrror back plz is 18mm mandatory
Mirror Etched mirror 6mm ply backing

Ready made rafters from euro pratik come in standard widths


Rafters (120mm-after overlapping).
Additional costing for bigger panels and proper joint
Back panel Tv wall panel max dimensions-8'x4' treatment
If there is no back panel for tv unit and all the wiring need to
be hidden ,
Following points to be considered :
1.wall thickness should be 9 inches,(need to be checked
during site validation)
Back panel
If there is no back panel for tv unit and all the wiring need to
be hidden ,
Following points to be considered :
2. TWO INCH pvc conduit pipe to be provided for hdmi cable(if
wall thickness is 9 inch) If less than 9inch,pvc conduit can not be provided,
Back panel hdmi cable will be visible.
-as per norms,no external agencies are allowed to touch it.
Smoke detector Smoke detectors and fire extinguishers to be moved Kindly make it clear to client
Only horizontal or vertical patterns are allowed(not a
T patti T patti can be used for swing doors only combination of both on one shutter)
Seperate costing for duco finish for internal carcass in
crockery /bar unit
Duco

If clients's requirement is 450 mm, we can either cost it by


Non standard base unit or must add 20% manual charges.
Quadra channels to used for the same for soft close to
Non standard Heavy unit- mirror pullout, study pull out- soft closed used work and should be charged
Shutter waviness-UV pre pressed panels from Action Tessa
Non standard can be suggested to clients

For 45mm Profile frame wardrobe 6mm mdf will be used for
Profile frame shutter shown in GFC
45 mm thick profile shutter for sliding doors will be having
6mm thick mdf with laminate is used,with 10 mm front look,5
mm groove to place 6 mm mdf,
in this case using only laminate will make the shutter less
weight (whereas opening the shutter need more force),so
Profile shutter laquered glass or mirror to be suggested to client .

Edge banding 1.3 mm edge banding provided for glossy laminates


Edge banding 2 mm edge banding provided for matt finish laminates
Edge banding 0.8 mm edge banding provided for liner laminates

All areas Width and height of individual ledges costed accordingly


All areas If there a is loft beside the beam ,filler is not required
Exposed panel extension of different units due site conditions
(beam,column projection,cement platform,chajja etc) to be
All areas charged extra
Instead of that push to open hinges or channels can be
suggested,but costing will have to be done for the
All areas Push to open not suggested same
All areas Drawer height more than 250 mm
If the height of a Jali door is more than 1500mm,minimum
All areas width of door 450mm
All areas T patti in sliding wardrobe is not acceptable.
Depth if it is more than 450mm Provide leg support or
All areas Wall mounted cabinet plan for Floor mounted cabinet

GFC Factory grooving mentioned in gfc


Kindly get structural and electrical drawing of the flat from the
GFC client before we give the electrical quote
Soft close/normal close for respective units
GFC mentioned in the GFC's
Wall,ceiling and flooring undulations needs to checked during
GFC site validation and gfc's revised accordingly
GFC Bed internal detail
In 2d only the material type has to be mentioned. Ex:
Finishes of Profile,glass,laminates mentioned only in 2d: profile glass shutter Specification sheet: ss brush
GFC specification sheet profile in frosted glass

Costing Polishing to be done for grooving in panelling. Additional charges for the same
If you are using this in your design, kindly mention in
Costing Glass door hinge - Overlay soft close. the gfc!
Costing Pooja Backlit panelling Kindly consider acrylic sheet
Additional charges will be applicable for fixing decorative Only fixing of spot lights,cove lights and profile lights
Costing lights. will be added by default in the electrical quote-
165 degree hinges are available with soft close and needs to be
Costing charged accordingly
Costing Additional drawers/ tray in puja unit costed
Costing Internal Ply organsier used Suggest readymade organiser with standard size.
Pooja Door Should not have om or any religious idols cutting
Pooja Unit in to half (In two Doors) Each door should complete Design