Jcb Tier 4 Troubleshooting Codes

Download as pdf or txt
Download as pdf or txt
You are on page 1of 319

Fault Codes Page 1 of 319

JCB EcoMAX Help Files

Fault Codes

Engine > Fault Codes

Click on the fault code to link devise specific information and fault finding procedure
Fault Code Background Information
Fault Codes
1. P0001
2. P0002
3. P0003
4. P0004
5. P0016
6. P0045
7. P006C
8. P007A
9. P007C
10. P007D
11. P0070
12. P0087
13. P0088
14. P0089
15. P008A
16. P0090
17. P0091
18. P0092
19. P0095
20. P0096
21. P0097
22. P0098
23. P0099
24. P00B7
25. P0100
26. P0101
27. P0102
28. P0103
29. P0105

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 2 of 319

30. P0106
31. P0110
32. P0111
33. P0112
34. P0113
35. P0115
36. P0116
37. P0117
38. P0118
39. P0120
40. P0121
41. P0129
42. P0180
43. P0181
44. P0182
45. P0183
46. P0190
47. P0191
48. P0192
49. P0193
50. P0194
51. P0195
52. P0196
53. P0197
54. P0198
55. P0200
56. P0201
57. P0202
58. P0203
59. P0204
60. P0220
61. P0230
62. P0236
63. P0237
64. P0238
65. P0252
66. P0253
67. P0254
68. P0261

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 3 of 319

69. P0262
70. P0263
71. P0264
72. P0265
73. P0266
74. P0267
75. P0268
76. P0269
77. P0270
78. P0271
79. P0272
80. P029A
81. P029B
82. P029E
83. P029F
84. P02A2
85. P02A3
86. P02A6
87. P02A7
88. P02EE
89. P02EF
90. P02F0
91. P02F1
92. P0321
93. P0325
94. P0330
95. P0335
96. P0340
97. P0341
98. P0350
99. P0371
100. P0372
101. P0374
102. P0380
103. P0381
104. P0383
105. P0384
106. P0400
107. P0460

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 4 of 319

108. P0470
109. P0471
110. P0472
111. P0473
112. P0500
113. P0501
114. P0503
115. P0520
116. P0521
117. P0522
118. P0523
119. P0544
120. P0545
121. P0546
122. P0560
123. P0562
124. P0563
125. P0566
126. P0567
127. P0569
128. P0570
129. P0575
130. P0602
131. P0603
132. P0604
133. P0605
134. P0606
135. P060A
136. P060B
137. P060C
138. P0612
139. P0615
140. P0616
141. P0617
142. P062D
143. P062E
144. P062F
145. P0627
146. P0628

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 5 of 319

147. P0629
148. P0630
149. P0641
150. P0650
151. P0651
152. P0655
153. P0656
154. P0658
155. P0659
156. P0668
157. P0669
158. P0685
159. P0697
160. P06A7
161. P0715
162. P1101
163. P1102
164. P1103
165. P1104
166. P1105
167. P1106
168. P1107
169. P1108
170. P1109
171. P110A
172. P110B
173. P1400
174. P1401
175. P1402
176. P1500
177. P1501
178. P1503
179. P1504
180. P1506
181. P1509
182. P1602
183. P2000
184. P202A
185. P202B

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 6 of 319

186. P202C
187. P202E
188. P203B
189. P203F
190. P2043
191. P204B
192. P204C
193. P204D
194. P204F
195. P205B
196. P205C
197. P205D
198. P205E
199. P207F
200. P2080
201. P208A
202. P208B
203. P208C
204. P208D
205. P209F
206. P20A0
207. P20A1
208. P20A2
209. P20A3
210. P20AD
211. P20B5
212. P20B6
213. P20B7
214. P20B8
215. P20B9
216. P20BA
217. P20BB
218. P20BC
219. P20BD
220. P20BE
221. P20BF
222. P20C0
223. P20C1
224. P20C2

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 7 of 319

225. P20C3
226. P20C4
227. P20E8
228. P20E9
229. P20EA
230. P20EB
231. P2100
232. P2101
233. P2102
234. P2103
235. P2120
236. P2125
237. P2135
238. P2138
239. P2147
240. P2148
241. P219D
242. P219E
243. P219F
244. P21A9
245. P21AB
246. P2200
247. P2201
248. P2202
249. P2203
250. P2208
251. P2209
252. P2226
253. P2228
254. P2229
255. P2264
256. P2265
257. P2266
258. P2267
259. P2269
260. P2413
261. P2428
262. P242B
263. P242C

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 8 of 319

264. P242D
265. P2502
266. P250B
267. P250F
268. P256A
269. P256B
270. P256C
271. P256D
272. P2620
273. P2670
274. P2671
275. P2685
276. P2686
277. P2A00
278. P2A01
279. P2BA7
280. P2BA8
281. P2BA9
282. P2BAA
283. P2BAB
284. P2BAE
285. P3401
286. P3402
287. P3403
288. P3404
289. P3405
290. P3406
291. P3407
292. P3408
293. P3409
294. P3410
295. P3411
296. P3412
297. P3413
298. P3414
299. P3415
300. P3416
301. P3417
302. P3418

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 9 of 319

303. P3419
304. P3420
305. P3421
306. P3422
307. P3423
308. P3424
309. P3425
310. U0001
311. U0029
312. U0073
313. U0100
314. U0105
315. U010A
316. U010C
317. U010E
318. U0121
319. U0140
320. U0401
321. U040B
322. U040D
323. U040F
324. U059E
325. U059F
326. U3FFF

JCB EcoMAX Help Files

Fault Code Background Information

Engine > Fault Codes > Fault Code Background Information

Fault Code Structure


Fault Code Display
Failure Type Byte (FTB) Numbers
Fault Code Structure
The structure of fault codes, otherwise known as 'Diagnostic Trouble Codes' (DTC's) has been standardised to a
7 digit code for all on and off-highway machine and vehicle applications. The standard (referred to as J2012)
requires all fault codes to conform to the following structure.
1st character - defines the system on the vehicle (eg P = Powertrain, C = Chassis, U = Network)
2nd and 3rd characters - defines the sub-system (eg transmission, CAN network, brakes etc)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 10 of 319

4th and 5th characters - specifies the particular component, circuit or fault (eg starter relay)
6th and 7th characters - referred to as the 'Failure Type Byte' (FTB) which indicates the particular failure (eg 11 =
short circuit to ground). See FTB Numbers below for a full list.
Some specific fault codes are defined by international standard, while other codes may be defined by individual
vehicle manufacturers.
Fault Code Display
Depending on the machine specification fault codes recorded by the engine ECU can be accessed and displayed
in several ways:
CAN Enabled Display
The machine may be equipped with a CAN enabled display. Such a display will be capable of displaying all
recorded codes, for example P0047. All logged codes will be displayed. The operator may also have a facility to
erase the fault code log. See the applicable machine documentation for further information.
CAN BUS Connected Computer
Error codes logged can be accessed via a suitable laptop computer running the applicable diagnostics software,
JCB 444 Engine Diagnostics for example. The computer must be connected to the machine CAN BUS socket
using a data link adapter (DLA). Once connected all recorded codes can be displayed. The engineer also has a
facility to erase the fault code log.
Failure Type Byte (FTB) Numbers

00 No sub type information

02 General signal failure

04 System internal failure (ECU)

07 Mechanical failure

05 System programming failure

09 Component failure

11 Short Circuit to Ground (SC2G)

12 Short Circuit to Battery (SC2VBAT)

13 Open Circuit (OC)

16 Circuit voltage below threshold

17 Circuit voltage above threshold

18 Circuit current below threshold

19 Circuit current above threshold

1A Circuit resistance above threshold

1B Circuit resistance below threshold

1C Circuit voltage out of range

1F Circuit intermittent

23 Signal stuck low

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 11 of 319

24 Signal stuck high

26 Signal rate of change below threshold

27 Signal rate of change above threshold

29 Signal invalid

2F Signal erratic

31 No Signal (lost/missing)

36 Signal frequency too low

37 Signal frequency too high

38 Signal frequency incorrect

45 Programme memory failure

46 Calibration / Parameter memory failure

47 Watchdog / micro-controller / microprocessor failure

4B Over temperature

54 Missing Calibration

64 Signal plausibility failure

62 Signal compare failure

71 Actuator stuck

72 Actuator stuck open

73 Actuator stuck closed

81 Received Network Data in Error

85 Signal above allowable range

86 CAN Signal invalid

87 Missing Message

88 BUS Off

9A Component or System Operating Conditions

92 Performance or incorrect operation

96 Component or Internal Failure

97 Component or System Operation Obstructed or Blocked

98 Component of System Over Temperature

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 12 of 319

JCB EcoMAX Help Files

P0001

Engine > Fault Codes > P0001

Fault Code Description


Information
Service Procedure
Related Fault Codes

Fault Code Description


Fuel volume regulator control circuit/open
Open circuit on the inlet metering valve

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
1. Check the harness is not damaged and is routed correctly.
2. Complete the testing procedure described in the component page Inlet metering valve.

Related Fault FTB Codes


Fault Code Description

P0001-13 Open circuit

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0002

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 13 of 319

Engine > Fault Codes > P0002

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel volume regulator control circuit range/performance
Circuit range fault on the inlet metering valve

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Inlet metering valve.

Related Fault FTB Codes


Fault Code Description

P0002-12 Short circuit to battery (SC2VBAT)

P0002-11 Short circuit to ground (SC2G)

P0002-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0003

Engine > Fault Codes > P0003

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 14 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel volume regulator control circuit low
Fault on the Inlet Metering Valve (IMV).

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.


Faulty component.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Inlet metering valve.

Related Fault FTB Codes


Fault Code Description

P0003-11 Short circuit to ground (SC2G)

P0003-13 Open circuit (OC)

P0003-19 Circuit current above threshold

P0003-0 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0004

Engine > Fault Codes > P0004

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 15 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel volume regulator control circuit high
Open circuit on the Inlet Metering Valve (IMV).

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Inlet metering valve.

Related Fault FTB Codes


Fault Code Description

P0004-12 Short Circuit To Battery (SC2VBAT)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0016

Engine > Fault Codes > P0016

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 16 of 319

Camshaft position correlation


Signal fault on the camshaft position sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty component.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page camshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0016-2F Signal erratic.

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0045

Engine > Fault Codes > P0045

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Turbocharger/supercharger boost control "A" circuit/open
Fault on the variable geometry turbocharger (VGT).

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 17 of 319

ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Variable Geometry Turbocharger (VGT).

Related Fault FTB Codes


Fault Code Description

P0045-13 Open circuit (OC)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P006C

Engine > Fault Codes > P006C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


MAP - Turbocharger/supercharger inlet pressure correlation
Fault on the TMAP sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors..

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 18 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page intake temperature and manifold absolute
pressure (TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P006C-11 Short circuit to ground (SC2G).

P006C-12 Short circuit to battery (SC2VBAT).

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P007A

Engine > Fault Codes > P007A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Charge air cooler temperature sensor circuit
Fault with the charge air temperature circuit.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 19 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page charge air cooler/intercooler outlet
temperature sensor.

Related Fault FTB Codes


Fault Code Description

P007A-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P007C

Engine > Fault Codes > P007C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Charge air cooler temperature sensor circuit low
Fault with the charge air cooler temperature sensor circuit.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page charge air cooler/intercooler outlet
temperature sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 20 of 319

Related Fault FTB Codes


Fault Code Description

P007C-23 Signal stuck low

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P007D

Engine > Fault Codes > P007D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Charge air cooler temperature sensor circuit high
Fault with the charge air cooler temperature sensor circuit.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors..

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page charge air cooler/intercooler outlet
temperature sensor.

Related Fault FTB Codes


Fault Code Description

P007D-24 Signal stuck high

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 21 of 319

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0070

Engine > Fault Codes > P0070

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Type text here

Information
ECU Aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate).

Possible Cause Damaged harness or harness connector.


Invalid data from ECU (other fault codes present).

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communications error.

Related Fault FTB Codes


Fault Code Description

P0070-81 Invalid signal data received (CAN BUS message error from engine ECU)

P0070-87 Missing CAN message from ECU

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 22 of 319

P0087

Engine > Fault Codes > P0087

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel rail/system pressure - too low
The fuel system pressure is too low.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction and delayed stop.

Possible Cause Fuel pipe restriction.


Fuel leak.
Damaged harness or harness connector.
Faulty sensor.
Faulty fuel pump.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check that the fuel tank has sufficient fuel in it.
2. Check the fuel lift pump flow, If the lift pump is inoperative check the lift pump relay.
3. If the fuel lift pump is still inoperative check the voltage, current and resistance at the pump.

Machine Minimum Maximum Minimum Maximum Minimum Maximum


Voltage Voltage Voltage Resistance Resistance Current Draw Current Draw
(Ohms) (Ohms) (Amps) (Amps)

12V 8V 16V 0.8 1.5 4 8

24V 20V 30V 4.9 5.7 4 5.5

4. Check for correct hose routing, restrictions or leaks from the fuel pipes. Make sure that fuel pipes have not
been trapped under other assemblies (e.g. cooling pack, hydraulic system components).
5. Replace fuel filters.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 23 of 319

6. Check the lift pump is delivering sufficient fuel. Refer to fuel lift pump test.
7. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
8. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Code Description

P0087-00 No sub type information.

P0087-24 Signal stuck high.

P0087-64 Signal plausibility failure.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0088

Engine > Fault Codes > P0088

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel rail/system pressure - too high
The fuel system pressure is too high.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged sensor.


Blocked fuel return pipe.
Damaged harness or connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Complete sensor checks and measurements for the IMV, common rail fuel pressure sensor and high

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 24 of 319

pressure fuel valve.


2. Check fuel return pipes are not trapped or blocked.
3. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
4. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Code Description

P0088-00 No sub type information

P0088-23 Signal stuck low

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0089

Engine > Fault Codes > P0089

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel pressure regulator 1 performance
Fuel rail pressure fault with the high pressure fuel valve.

Information
ECU Engine ECU

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 25 of 319

3. Complete the testing procedure described in the component page high pressure fuel valve.

Related Fault FTB Codes


Fault Code Description

P0089-00 No sub type information

P0089-11 Short Circuit To Ground (SC2G)

P0089-19 Circuit current above threshold

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P008A

Engine > Fault Codes > P008A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Low pressure fuel system pressure - too low
Fault with the fuel injector.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connector, faulty injector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 26 of 319

Fault Code Description

P008A-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0090

Engine > Fault Codes > P0090

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel pressure regulator 1 control circuit open
Fault with the high pressure fuel valve (HPV).

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page high pressure fuel valve (HPV).

Related Fault FTB Codes


Fault Code Description

P0090-00 no sub type information

P0090-13 Open circuit (OC)

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 27 of 319

JCB EcoMAX Help Files

P0091

Engine > Fault Codes > P0091

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel pressure regulator 1 control circuit low
Fault with the high pressure fuel valve (HPV).

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page high pressure fuel valve (HPV).

Related Fault FTB Codes


Fault Code Description

P0091-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0092

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 28 of 319

Engine > Fault Codes > P0092

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel pressure regulator 1 control circuit high
Fault with the high pressure fuel valve (HPV).

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors, faulty HPV.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page high pressure fuel valve (HPV).

Related Fault FTB Codes


Fault Code Description

P0092 Check HPV regulation control trim high

P0092 Check HPV hardware current control trim high

P0092 HPV current feedback high fault detected

P0092 HPV driver in ECU short circuit to battery voltage (SC2VBATT) fault is detected

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0095

Engine > Fault Codes > P0095

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 29 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 2 circuit
Fault with the temperature and manifold absolute pressure (TMAP) sensor.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature and manifold pressure
(TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0095-00 No sub type informtion

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0096

Engine > Fault Codes > P0096

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 30 of 319

Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 2 circuit range/performance
Fault with the temperature and manifold absolute pressure (TMAP) sensor.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors, faulty TMAP sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature and manifold pressure
(TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0096-2F Signal erratic

This topic last edited on 08/02/2016

JCB EcoMAX Help Files

P0097

Engine > Fault Codes > P0097

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 2 circuit low
Fault with the temperature and manifold absolute pressure (TMAP) sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 31 of 319

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connector, faulty TMAP sensor

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature and manifold pressure
(TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0097-11 Short circuit to ground (SC2G)

P0097-223 Short circuit to battery (SC2VBAT)

This topic last edited on 08/02/2016

JCB EcoMAX Help Files

P0098

Engine > Fault Codes > P0098

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 2 circuit high
Fault with the temperature and manifold absolute pressure (TMAP) sensor.

Information
ECU Engine ECU

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 32 of 319

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature and manifold pressure
(TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0098-24 Signal stuck high

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0099

Engine > Fault Codes > P0099

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 2 circuit intermittent/erratic
Fault with the intake temperature and manifold absolute pressure (TMAP) sensor circuit.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 33 of 319

Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature and manifold pressure
(TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0099-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P00B7

Engine > Fault Codes > P00B7

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


CAN BUS message error for coolant sensor from Engine ECU
Missing CAN message error for coolant sensor from the ECU.

Information
ECU Engine ECU

Effect Error code.

Possible Cause Damaged harness or harness connectors, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 34 of 319

3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P00B7-87 Missing CAN message (CAN BUS message error for coolant sensor from engine ECU)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0100

Engine > Fault Codes > P0100

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Mass or volume air flow "A" circuit
Fault with the temperature mass air flow (TMAF) sensor.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature mass air flow (TMAF) sensor.

Related Fault FTB Codes


Fault Code Description

P0100-00 no sub type information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 35 of 319

P0100-19 Circuit current above threshold

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0101

Engine > Fault Codes > P0101

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Mass or volume air flow "A" circuit range/performance
Fault on the temperature mass air flow (TMAF) sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature mass air flow (TMAF) sensor.

Related Fault FTB Codes


Fault Code Description

P0101-11 Short circuit to ground (SC2G)

P0101-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 36 of 319

JCB EcoMAX Help Files

P0102

Engine > Fault Codes > P0102

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Mass or volume air flow "A" circuit low
Fault on the temperature mass air flow (TMAF) sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature mass air flow (TMAF) sensor.

Related Fault FTB Codes


Fault Code Description

P0102-11 Short Circuit To Ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0103

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 37 of 319

Engine > Fault Codes > P0103

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Mass or volume air flow "A" circuit high
Fault on the temperature mass air flow (TMAF) sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page temperature mass air flow (TMAF) sensor.

Related Fault FTB Codes


Fault Code Description

P0102-12 Short Circuit To Battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0105

Engine > Fault Codes > P0105

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 38 of 319

Related Fault FTB Codes

Fault Code Description


Manifold absolute pressure/barometric pressure circuit
Fault on the temperature and manifold absolute pressure (TMAP) sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page intake temperature and manifold absolute
pressure (TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0105-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0106

Engine > Fault Codes > P0106

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Manifold absolute pressure/barometric pressure circuit range/performance
Fault on the temperature and manifold absolute pressure (TMAP) sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 39 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page intake temperature and manifold absolute
pressure (TMAP) sensor.

Related Fault FTB Codes


Fault Code Description

P0106-00 no sub type information

P0106-11 Short circuit to ground (SC2G)

P0106-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0110

Engine > Fault Codes > P0110

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 1 circuit
Fault on the temperature mass air flow (TMAF) sensor.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 40 of 319

ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors,


faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page intake temperature mass air flow (TMAF)
sensor.

Related Fault FTB Codes


Fault Code Description

P0110-00 no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0111

Engine > Fault Codes > P0111

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 1 circuit low
Fault on the temperature mass air flow (TMAF) sensor.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 41 of 319

Possible Cause Damaged harness or harness connectors, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page intake temperature mass air flow (TMAF)
sensor.

Related Fault FTB Codes


Fault Code Description

P0111-64 Signal plausibility failure

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0112

Engine > Fault Codes > P0112

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 1 circuit high
Fault on the temperature mass air flow (TMAF) sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 42 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page intake temperature mass air flow (TMAF)
sensor.

Related Fault FTB Codes


Fault Code Description

P0112-11 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0113

Engine > Fault Codes > P0113

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Intake air temperature sensor 1 circuit high
Fault on the temperature mass air flow (TMAF) sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 43 of 319

3. Complete the testing procedure described in the component page intake temperature mass air flow (TMAF)
sensor.

Related Fault FTB Codes


Fault Code Description

P0113-12 Short circuit to battery (SC2VBAT)

P0113-24 Signal stuck high (open circuit)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0115

Engine > Fault Codes > P0115

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine coolant temperature sensor 1 circuit
Fault on the coolant sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page coolant temperature sensor.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 44 of 319

Fault Code Description

P0115-00 No sub type information

P0115-11 Short circuit to ground (SC2G)

P0115-15 Short circuit to battery (SC2VBAT) or open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0116

Engine > Fault Codes > P0116

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine coolant temperature sensor 1 circuit range/performance
Fault on the coolant sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page coolant temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0116-2F Signal erratic

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 45 of 319

P0116-64 Signal plausibility failure

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0117

Engine > Fault Codes > P0117

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine coolant temperature sensor 1 circuit low
Fault on the coolant sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page coolant temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0117-11 Short circuit to ground (SC2G)

P0117-23 Signal stuck low

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 46 of 319

JCB EcoMAX Help Files

P0118

Engine > Fault Codes > P0118

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine coolant temperature sensor 1 circuit high
Fault on the coolant sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page coolant temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0118-12 Short circuit to ground (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0120

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 47 of 319

Engine > Fault Codes > P0120

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle/pedal position sensor/switch "A" circuit
Fault on the throttle pedal switch.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged Harness or harness connectors, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P0120-00 No sub type information

P0120-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0121

Engine > Fault Codes > P0121

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 48 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle/pedal position sensor/switch "A" circuit range/performance
Fault on the throttle pedal switch.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged Harness or harness connectors, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P0121-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0129

Engine > Fault Codes > P0129

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Barometric pressure signal from engine ECU
CAN BUS message error for barometric pressure.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 49 of 319

Information
ECU Engine ECU.

Effect Error code.

Possible Cause Damaged Harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P0129-87 Missing CAN message from engine ECU (Erroneous signal for barometric pressure)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0180

Engine > Fault Codes > P0180

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel temperature sensor "A" circuit
Fault on the fuel temperature sensor circuit.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 50 of 319

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0180-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0181

Engine > Fault Codes > P0181

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel Temperature
Erroneous signal for fuel temperature.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 51 of 319

procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel temperature sensor.

Related Fault FTB Codes


Fault Description
Code

P0181-27 Signal rate of change above threshold (fuel temperature sensor gradient fault)

P0181-87 Missing CAN message from engine ECU (CAN bus message error for fuel temperature from engine
ECU)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0182

Engine > Fault Codes > P0182

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel temperature sensor "A" circuit low
Fault on the fuel temperature sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 52 of 319

2. Check the harness is not damaged and is routed correctly.


3. Complete the testing procedure described in the component page fuel temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0182-11 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0183

Engine > Fault Codes > P0183

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel temperature sensor "A" circuit high
Fault on the fuel temperature sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel temperature sensor.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 53 of 319

P0183-12 Short circuit to bettery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0190

Engine > Fault Codes > P0190

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel rail pressure sensor "A" circuit
Fault on the common rail fuel pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page common rail fuel pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0190-64 Signal plausibility failure

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 54 of 319

P0191

Engine > Fault Codes > P0191

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel rail pressure sensor "A" circuit range/performance
Fault on the common rail fuel pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page common rail fuel pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0191-00 No sub type information

P0191-11 Short circuit to ground (SC2G)

P0191-12 Short circuit to battery (SC2VBAT)

P0191-24 Signal stuck high

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 55 of 319

JCB EcoMAX Help Files

P0192

Engine > Fault Codes > P0192

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel rail pressure sensor "A" circuit low
Fault on the common rail fuel pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page common rail fuel pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0192-11 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0193

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 56 of 319

Engine > Fault Codes > P0193

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel rail pressure sensor "A" circuit high
Fault on the common rail fuel pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page common rail fuel pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0193-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0194

Engine > Fault Codes > P0194

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 57 of 319

Related Fault FTB Codes

Fault Code Description


Fuel rail pressure sensor "A" circuit intermittent/erratic
Fault on the common rail fuel pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page common rail fuel pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0194-23 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0195

Engine > Fault Codes > P0195

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil temperature sensor circuit
Fault on the oil temperature sensor circuit.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 58 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0195-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0196

Engine > Fault Codes > P0196

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil temperature sensor range/performance
Missing CAN message.

Information
ECU Engine ECU/ aftertreatment system ECU.

Effect Error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 59 of 319

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component pages oil temperature sensor and CAN
communication error.

Related Fault FTB Codes


Fault Description
Code

P0196-27 Signal rate of change above threshold - Engine ECU (oil temperature sensor signal gradient fault)

P0196-64 Signal plausibility failure - Engine ECU (Oil temperature sensor signal gradient fault)

P0196-87 Missing CAN message from engine ECU - Aftertreatment DCU (CAN BUS message error for oil
temperature from engine ECU)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0197

Engine > Fault Codes > P0197

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil temperature sensor circuit low
Fault on the oil temperature sensor circuit.

Information
ECU Engine ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 60 of 319

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0197-11 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0198

Engine > Fault Codes > P0198

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil temperature sensor circuit high
Fault on the oil temperature sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 61 of 319

procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0198-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0200

Engine > Fault Codes > P0200

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector circuit/open
Open circuit on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 62 of 319

Related Fault FTB Codes


Fault Code Description

P0200-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0201

Engine > Fault Codes > P0201

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector circuit/open - cylinder 1
Open circuit on the fuel injector.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.


Engine fails to start or stops if running.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0201-00 No sub type information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 63 of 319

P0201-11 Short circuit to ground (SC2G)

P0201-13 Open circuit (OC)

This topic last edited on 13/10/2016

JCB EcoMAX Help Files

P0202

Engine > Fault Codes > P0202

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector circuit/open - cylinder 2
Open circuit on the fuel injector.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.


Engine fails to start or stops if running.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0202-00 No sub type information

P0202-13 Open circuit (OC)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 64 of 319

This topic last edited on 13/10/2016

JCB EcoMAX Help Files

P0203

Engine > Fault Codes > P0203

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector circuit/open - cylinder 3
Open circuit on the fuel injector.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.


Engine fails to start or stops if running

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0203-00 No sub type information

P0203-13 Open circuit (OC)

This topic last edited on 13/10/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 65 of 319

P0204

Engine > Fault Codes > P0204

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector circuit/open - cylinder 4
Open circuit on the fuel injector.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.


Engine fails to start or stops if running

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0204-00 No sub type information

P0204-13 Open circuit (OC)

This topic last edited on 13/10/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 66 of 319

P0220

Engine > Fault Codes > P0220

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle/pedal position sensor/switch "B" circuit
Fault on the foot throttle position sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page foot throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P0220-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0230

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 67 of 319

Engine > Fault Codes > P0230

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel pump primary circuit
Fault on the low pressure fuel supply circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel lift pump relay.

Related Fault FTB Codes


Fault Code Description

P0230-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0236

Engine > Fault Codes > P0236

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 68 of 319

Related Fault FTB Codes

Fault Code Description


Turbocharger/Supercharger Boost Sensor "A" Circuit Range/Performance
Fault on the TMAP sensor.

Information
ECU Engine ECU.

Effect Torque reduction.

Possible Cause Faulty TMAP Sensor.


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page TMAP sensor.

Related Fault FTB Codes


Fault Code Description

P0236-11 Short circuit to ground (SC2G).

P0236-12 Short circuit to battery (SC2VBAT).

P0236-16 Circuit voltage below threshold.

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0237

Engine > Fault Codes > P0237

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 69 of 319

Fault Code Description


Turbocharger/Supercharger Boost Sensor "A" Circuit Low
Boost Pressure signal too low.

Information
ECU Engine ECU.

Effect Torque reduction.

Possible Cause Faulty TMAP sensor.


Damaged harness or harness connector.
Inlet air leak.
Faulty turbocharger.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page variable geometry turbocharger (VGT).

Related Fault FTB Codes


Fault Code Description

P0237-11 Short circuit to ground (SC2G).

P0237-16 Circuit voltage below threshold.

P0237-17 Circuit voltage above threshold.

P0237-21 Data drifted low.

P0237-23 Signal stuck low.

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0238

Engine > Fault Codes > P0238

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 70 of 319

Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Turbocharger/Supercharger Boost Sensor "A" Circuit High
Boost Pressure signal too high.

Information
ECU Engine ECU.

Effect Torque reduction.

Possible Cause Faulty TMAP sensor.


Damaged harness or harness connector.
Faulty turbocharger.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page variable geometry turbocharger (VGT).

Related Fault FTB Codes


Fault Code Description

P0238-12 Short circuit to battery (SC2VBAT).

P0238-17 Circuit voltage above threshold

P0238-22 Data drifted high.

P0238-24 Signal stuck high.

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0252

Engine > Fault Codes > P0252

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 71 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injection pump fuel metering control "A" range/performance (cam/rotor/injector)
Fault on the inlet metering valve (IMV).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page inlet metering valve.

Related Fault FTB Codes


Fault Code Description

P0252-00 No sub type information

P0252-11 Short circuit to ground (SC2G)

P0252-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0253

Engine > Fault Codes > P0253

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 72 of 319

Related Fault FTB Codes

Fault Code Description


Low Fuel Flow - IMV
Insufficient fuel flow from the low pressure fuel system (tank, low pressure pump,filters) or IMV electrical fault.

Information
ECU Engine ECU.

Effect

Possible Cause Fuel pipe restriction.


Fuel leak.
Faulty fuel pump.
Damaged harness or harness connector.
Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check that the fuel tank has sufficient fuel in it.
2. Complete the injector leak back test testing procedure described in fuel system diagnostic test.
3. Check the fuel lift pump flow, If the lift pump is inoperative check the lift pump relay.
4. If the fuel lift pump is still inoperative check the voltage, current and resistance at the pump.

Machine Minimum Maximum Minimum Maximum Minimum Maximum


Voltage Voltage Voltage Resistance Resistance Current Draw Current Draw
(Ohms) (Ohms) (Amps) (Amps)

12V 8V 16V 0.8 1.5 4 8

24V 20V 30V 4.9 5.7 4 5.5

5. Check for correct hose routing, restrictions or leaks from the fuel pipes. Make sure that fuel pipes have not
been trapped under other assemblies (e.g. cooling pack, hydraulic system components).
6. Replace fuel filters.
7. Check the lift pump is delivering sufficient fuel. Refer to fuel lift pump test.
8. Check the low pressure fuel system for restrictions such as: Blockages, damaged hoses, blocked fuel filters,
damaged in tank fuel pick up.
9. Check high pressure fuel pump, common rail and injector leak off and repair as required.
10. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
11. Check the harness is not damaged and is routed correctly.
12. Complete the testing procedure described in the component page inlet metering valve.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 73 of 319

Related Fault FTB Codes


Fault Code Description

P0253-00 No sub type information

P0253-23 Signal stuck low

This topic last edited on 13/10/2016

JCB EcoMAX Help Files

P0254

Engine > Fault Codes > P0254

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injection pump fuel metering control "A" high (cam/rotor/injector)
Fault on the inlet metering valve (IMV).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page inlet metering valve.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 74 of 319

P0254-24 Signal stuck high

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0261

Engine > Fault Codes > P0261

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 1 injector circuit Low
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0261-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 75 of 319

P0262

Engine > Fault Codes > P0262

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 1 injector circuit high
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0262-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0263

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 76 of 319

Engine > Fault Codes > P0263

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 1 contribution/balance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0263-23 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0264

Engine > Fault Codes > P0264

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 77 of 319

Related Fault FTB Codes

Fault Code Description


Cylinder 2 injector circuit low
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0264-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0265

Engine > Fault Codes > P0265

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 2 injector circuit high
Fault on the fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 78 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0265-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0266

Engine > Fault Codes > P0266

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 2 contribution/balance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 79 of 319

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0266-23 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0267

Engine > Fault Codes > P0267

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 3 injector circuit low
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 80 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0267-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0268

Engine > Fault Codes > P0268

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 3 injector circuit high
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 81 of 319

Related Fault FTB Codes


Fault Code Description

P0268-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0269

Engine > Fault Codes > P0269

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 3 contribution/balance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0269-23 Signal stuck low

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 82 of 319

JCB EcoMAX Help Files

P0270

Engine > Fault Codes > P0270

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 4 injector circuit low
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0270-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0271

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 83 of 319

Engine > Fault Codes > P0271

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 4 injector circuit high
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0271-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0272

Engine > Fault Codes > P0272

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 84 of 319

Related Fault FTB Codes

Fault Code Description


Cylinder 4 contribution/balance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P0272-23 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P029A

Engine > Fault Codes > P029A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 1 fuel trim at maximum limit
Fault on the fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 85 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P029A-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P029B

Engine > Fault Codes > P029B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 1 fuel trim at minimum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 86 of 319

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P029B-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P029E

Engine > Fault Codes > P029E

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 2 fuel trim at maximum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 87 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P029E-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P029F

Engine > Fault Codes > P029F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 2 fuel trim at minimum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 88 of 319

Related Fault FTB Codes


Fault Code Description

P029F-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02A2

Engine > Fault Codes > P02A2

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 3 fuel trim at maximum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02A2-00 No sub type information

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 89 of 319

JCB EcoMAX Help Files

P02A3

Engine > Fault Codes > P02A3

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 3 fuel trim at minimum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02A3-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02A6

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 90 of 319

Engine > Fault Codes > P02A6

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 4 fuel trim at maximum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02A6-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02A7

Engine > Fault Codes > P02A7

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 91 of 319

Related Fault FTB Codes

Fault Code Description


Cylinder 4 fuel trim at minimum limit
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02A7-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02EE

Engine > Fault Codes > P02EE

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 1 injector circuit range/performance
Fault on the fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 92 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02EE-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02EF

Engine > Fault Codes > P02EF

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 2 injector circuit range/performance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 93 of 319

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02EF-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02F0

Engine > Fault Codes > P02F0

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 3 injector circuit range/performance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 94 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P02F0-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P02F1

Engine > Fault Codes > P02F1

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cylinder 4 injector circuit range/performance
Fault on the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 95 of 319

Related Fault FTB Codes


Fault Code Description

P02F1-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0321

Engine > Fault Codes > P0321

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine Speed
Erroneous signal for engine speed.

Information
ECU Engine ECU.

Effect Error code and inducement.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Description
Code

P0321-87 Missing message CAN message from ECU (CAN BUS message for engine speed from engine

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 96 of 319

ECU)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0325

Engine > Fault Codes > P0325

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Knock Sensor 1 Circuit
Fault on the knock sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page knock sensor.

Related Fault FTB Codes


Fault Code Description

P0325-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 97 of 319

P0330

Engine > Fault Codes > P0330

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Knock Sensor 2 Circuit
Fault on the knock sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page knock sensor.

Related Fault FTB Codes


Fault Code Description

P0330-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0335

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 98 of 319

Engine > Fault Codes > P0335

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Crankshaft Position Sensor "A" Circuit
Fault on the crankshaft position sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty crankshaft position sensor.
Excessive engine speed (P0335-85), e.g. machine in over-run traveling
downhill in a low gear and/or with the torque convertor lock up engaged.
If the fault occurrence is low, it could be generated as a result of a sudden
engine stall (P0335-31).

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Disconnect the electrical connector from the engine ECU.
2. Make sure that the is correctly installed and is not damaged or corroded.
3. Disconnect the electrical connector from the crankshaft sensor.
4. Use a multi-meter to test for wire continuity (open circuits) between the relevant connector pins. Refer to the
component help page crankshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0335-00 Crank sensor fault (No signal)


P0335-31 No signal (lost/missing)

P0335-85 Crank signal overspeed fault

This topic last edited on 26/09/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 99 of 319

P0340

Engine > Fault Codes > P0340

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Camshaft position sensor "A" circuit
Fault on the camshaft position sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page camshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0340-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0341

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 100 of 319

Engine > Fault Codes > P0341

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Camshaft position sensor "A" circuit range/performance
Fault on the camshaft position sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty sensor.
Sudden or harsh engine stop.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. If the engine has been stalled or subject to a sudden stop this fault code can be triggered. The fault code can
be cleared and should not return when the engine is started.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page camshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0341-00 No sub type information

P0341-2F Signal erratic

P0341-31 No Signal (lost/missing)

This topic last edited on 13/09/2016


Fault Code Description
Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 101 of 319

Fault Code Description


Monitoring for system protection based on ignition switch input
This fault code indicates an error with the monitoring for system protection based on T15 status.

Information
ECU Aftertreatment ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector, out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Make sure that the ECU software is up to date. If it is not refer to Re-flashing an ECU.
4. Complete the testing procedure described in the component page aftertreatment ECU.

Related Fault FTB Codes


Fault Code Description

P0350-02 General signal failure

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0371

Engine > Fault Codes > P0371

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes
Fault Code Description
Timing reference high resolution signal "A" too many pulses
Fault on the crankshaft position sensor circuit.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 102 of 319

ECU Engine ECU.

Effect

Possible Cause Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page crankshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0371-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0372

Engine > Fault Codes > P0372

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Timing reference high resolution signal "A" too few pulses
Fault on the crankshaft position sensor.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connector, faulty sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 103 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page crankshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0372-31 Elapsed time between CPS events is too high

P0372-2F Signal erratic

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0374

Engine > Fault Codes > P0374

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Timing reference high resolution signal "A" no pulses
Fault on the crankshaft position sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 104 of 319

connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page crankshaft position sensor.

Related Fault FTB Codes


Fault Code Description

P0374-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0380

Engine > Fault Codes > P0380

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Glow plug/heater circuit "A"
Fault on the grid heater relay control.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page grid heater.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 105 of 319

Fault Code Description

P0380-00 No sub type information

P0380-13 Open circuit (OC)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0381

Engine > Fault Codes > P0381

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Glow plug/heater indicator circuit
Fault on the grid heater relay control.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page grid heater.

Related Fault FTB Codes


Fault Code Description

P0381-00 No sub type information

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 106 of 319

JCB EcoMAX Help Files

P0383

Engine > Fault Codes > P0383

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Glow plug control module control circuit low
Fault on the grid heater relay control.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page grid heater.

Related Fault FTB Codes


Fault Code Description

P0383-19 Circuit current above threshold

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0384

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 107 of 319

Engine > Fault Codes > P0384

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Glow plug control module control circuit high
Fault on the grid heater relay control.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page grid heater.

Related Fault FTB Codes


Fault Code Description

P0384-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0400

Engine > Fault Codes > P0400

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 108 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas recirculation "A" flow
Fault on the exhaust gas recirculation (EGR) control system.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Blocked EGR valve.


Blocked EGR mixer tube or inlet manifold.
Blocked EGR cooler.
Boost leak.
EGR system exhaust gas leak.
Blocked exhaust gas pressure sensor or tube.
Faulty or missing exhaust restrictor.
Faulty or missing intake restrictor.
Faulty mass airflow sensor, damaged airbox or air intake hose.
Faulty intake manifold pressure sensor.
Missing CAN termination resistor.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. If P0400-00 is present along with either U040B or U040D, refer to P0400-00 CANBUS Test.
2. If P0400-00 is present on its own perform a visual check of the system by following the P0400-00 Visual
Checklist. This checklist must be complete before moving to the next step to rule out other root causes.
3. If P0400-00 is still present continue to P0400-00 Test page.

Related Fault FTB Codes


Fault Code Description

P0400-00 EGR Flow limit reached OR EGR CAN communication error (T4i engines only)

U040B Fault on the CAN communication network

U040D Fault detected with the VGT electrical or mechanical system

This topic last edited on 25/11/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 109 of 319

JCB EcoMAX Help Files

P0460

Engine > Fault Codes > P0460

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Low fuel Level

Information
ECU Engine ECU.

Effect Fuel light on.

Possible Cause Low fuel Level.


Damaged Harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check the fuel level, fill as required.

Related Fault FTB Codes


Fault Code Description

P0460-7B Fuel tank empty (<6% full)

P0460-21 Fuel tank level low (<12% full)

This topic last edited on 25/06/2015

JCB EcoMAX Help Files

P0470

Engine > Fault Codes > P0470

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 110 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust pressure sensor "A" circuit
Fault on the exhaust manifold pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0470-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0471

Engine > Fault Codes > P0471

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 111 of 319

Exhaust pressure sensor "A" circuit range/performance


Fault on the exhaust manifold pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0471-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0472

Engine > Fault Codes > P0472

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust pressure sensor "A" circuit low
Fault on the exhaust manifold pressure sensor.

Information
ECU Engine ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 112 of 319

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0472-11 Short circuit to ground (SC2G)

P0472-23 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0473

Engine > Fault Codes > P0473

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust pressure sensor "A" circuit high
Fault on the exhaust manifold pressure sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 113 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold pressure sensor.

Related Fault FTB Codes


Fault Code Description

P0473-12 Short circuit to battery (SC2VBAT)

P0473-23 Signal stuck high

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0500

Engine > Fault Codes > P0500

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Vehicle speed sensor "A"
Fault on the vehicle speed sensor input.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 114 of 319

connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page vehicle speed sensor.

Related Fault FTB Codes


Fault Code Description

P0500-00 No sub type information

P0500-2F Signal erratic

This topic last editedA on 08/09/2015

JCB EcoMAX Help Files

P0501

Engine > Fault Codes > P0501

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Vehicle speed sensor "A" range/performance
Fault on the vehicle speed sensor input.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page vehicle speed sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 115 of 319

Related Fault FTB Codes


Fault Code Description

P0501-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0503

Engine > Fault Codes > P0503

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Vehicle speed sensor "A" intermittent/erratic/high
Fault on the vehicle speed sensor input.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page vehicle speed sensor.

Related Fault FTB Codes


Fault Code Description

P0503-64 Signal plausibility failure

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 116 of 319

JCB EcoMAX Help Files

P0520

Engine > Fault Codes > P0520

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Low oil pressure lamp drive circuit
Fault on the circuit used to control the low oil pressure light.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty low oil pressure warning lamp.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check the low oil pressure lamp.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Check the ignition circuit and fuses.

Related Fault FTB Codes


Fault Code Description

P0520-00 No sub type information

P0520-11 Short circuit to ground (SC2G)

P0520-12 Short circuit to battery (SC2VBAT)

P0520-13 Open circuit (OC)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 117 of 319

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0521

Engine > Fault Codes > P0521

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil pressure sensor/switch range/performance
Fault on the oil pressure switch circuit.

Information
ECU Engine ECU

Effect

Possible Cause Faulty oil pressure switch.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil pressure switch.

Related Fault FTB Codes


Fault Code Description

P0521-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 118 of 319

P0522

Engine > Fault Codes > P0522

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


High oil pressure (engine running/engine stopped)
Unexpected high oil pressure signal received either when the engine is stopped or while the engine is running.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil pressure switch.

Related Fault FTB Codes


Fault Code Description

P0522-23 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0523

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 119 of 319

Engine > Fault Codes > P0523

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Low oil pressure during engine running
Fault on the circuit used to control the low oil pressure light.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty sensor, low engine oil
pressure.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil pressure switch.

Related Fault FTB Codes


Fault Code Description

P0523-24 Signal stuck low

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0544

Engine > Fault Codes > P0544

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 120 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas temperature sensor circuit
Fault on the exhaust gas temperature sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0544-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0545

Engine > Fault Codes > P0545

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas temperature sensor circuit low
Fault on the exhaust gas temperature sensor circuit.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 121 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0545-11 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0546

Engine > Fault Codes > P0546

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas temperature sensor circuit high
Fault on the exhaust gas temperature sensor circuit.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 122 of 319

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust manifold temperature sensor.

Related Fault FTB Codes


Fault Code Description

P0546-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0560

Engine > Fault Codes > P0560

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


System voltage
Fault with the battery voltage.

Information
ECU Engine ECU/aftertreatment ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty or discharged battery.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 123 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page battery voltage fault.

Related Fault FTB Codes


Fault Code Description

P0560-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0562

Engine > Fault Codes > P0562

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


System voltage low
Fault with the battery voltage.

Information
ECU Engine ECU/aftertreatment ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty or discharged battery.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page battery voltage fault.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 124 of 319

Related Fault FTB Codes


Fault Code Description

P0562-02 General signal failure (fault due to low or high battery voltage supply to ECU)

P0562-16 Circuit voltage below threshold (Low battery voltage)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0563

Engine > Fault Codes > P0563

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


System voltage high
Fault with the battery voltage.

Information
ECU Engine ECU/aftertreatment ECU.

Effect

Possible Cause Damaged harness or harness connector, faulty battery or over charged
battery.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page battery voltage fault.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 125 of 319

P0563-17 Circuit voltage above threshold

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0566

Engine > Fault Codes > P0566

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cruise control "off" signal
Fault with the cruise control system.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page cruise control switch.

Related Fault FTB Codes


Fault Code Description

P0566-00 no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 126 of 319

P0567

Engine > Fault Codes > P0567

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cruise control "off" signal
Fault with the cruise control system.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page cruise control switch.

Related Fault FTB Codes


Fault Code Description

P0567-00 no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0569

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 127 of 319

Engine > Fault Codes > P0569

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cruise control "coast" signal
Fault with the cruise control system.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page cruise control switch.

Related Fault FTB Codes


Fault Code Description

P0569-00 no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0570

Engine > Fault Codes > P0570

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 128 of 319

Related Fault FTB Codes

Fault Code Description


Cruise control "accelerate" signal
Fault with the cruise control system.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page cruise control switch.

Related Fault FTB Codes


Fault Code Description

P0570-00 no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0575

Engine > Fault Codes > P0575

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Cruise control input circuit
Fault with the cruise control system.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 129 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page cruise control switch.

Related Fault FTB Codes


Fault Code Description

P0575-00 no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0602

Engine > Fault Codes > P0602

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Control module programming error
Fault with the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 130 of 319

Possible Cause Incorrect or out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Make sure that the ECU software is up to date. Refer to re-flashing an ECU.
2. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P0602-00 No sub type information

P0602-2F Signal erratic

P0602-55 Out of calibration

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0603

Engine > Fault Codes > P0603

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Internal control module keep alive memory (KAM) error
Fault with the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty ECU.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 131 of 319

procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P0603-2F no sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0604

Engine > Fault Codes > P0604

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Internal control module random access memory (RAM) error
Fault with the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty ECU.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 132 of 319

3. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P0604-2F signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0605

Engine > Fault Codes > P0605

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Internal control module read only memory (ROM) error
Fault with the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty ECU.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 133 of 319

P0605-2F signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0606

Engine > Fault Codes > P0606

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Peripheral monitoring error on DCU
Fault with the peripheral monitoring function on the aftertreatment system electronic control unit (ECU).

Information
ECU Aftertreatment ECU and engine ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.


Incorrect or out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Make sure that the ECU software is up to date. Refer to re-flashing an ECU.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P0606-02 General signal failure (peripheral monitoring error on DCU)

P0606-06 Algorithm based failure (functional safety fault)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 134 of 319

P0606-49 Internal electronic failure (main CPU fault)

P0606-86 Signal invalid (functional safety fault)

P0606-87 Missing CAN message

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P060A

Engine > Fault Codes > P060A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Monitoring error on aftertreatment ECU - functional safety fault
Aftertreatment ECU has detected an error during a PostDrive ROM test.

Information
ECU Aftertreatment system ECU.

Effect Inducement derate, error code.

Possible Cause Damaged harness or harness connector.


Incorrect or out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Make sure that the ECU software is up to date. Refer to re-flashing an ECU.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Description
Code

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 135 of 319

P060A-00 No sub type information

P006A-92 Performance or incorrect performance - engine ECU (internal control module monitoring processor
performance)

P060A-93 No operation - engine ECU (internal control module monitoring processor performance)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P060B

Engine > Fault Codes > P060B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Internal control module A/D processing performance - functional safety fault
Processing fault within within the engine ECU

Information
ECU Engine ECU.

Effect Inducement derate, error code.

Possible Cause Damaged harness or harness connector.


Incorrect or out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Make sure that the ECU software is up to date. Refer to re-flashing an ECU.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 136 of 319

P060B-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P060C

Engine > Fault Codes > P060C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Monitoring error on aftertreatment or engine ECU
Engine or aftertreatment ECU has detected an internal ECU fault.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate) Engine Inducement, error code.

Possible Cause Damaged harness or harness connector.


Incorrect or out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Use the FTB code table below to establish which ECU has flagged the fault code.
2. Make sure that the ECU software is up to date. Refer to re-flashing an ECU.
3. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
4. Check the harness is not damaged and is routed correctly.
5. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P060C-00 No sub type information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 137 of 319

P060C-F0 Unallocated (JCB Controlled) - engine ECU (Internal control module main processor performance)

P060C-F1 Unallocated (JCB Controlled) - engine ECU (Internal control module main processor performance)

P060C-F2 Unallocated (JCB Controlled) - engine ECU (Internal control module main processor performance)

P060C-41 General checksum failure - aftertreatment system ECU

P060C-44 Data memory failure - engine ECU

P060C-46 Calibration /Parameter main processor memory failure - engine ECU

P060C-68 Event information (aftertreatment system ECU software reset performed)

P060C-94 Unexpected operation (aftertreatment system ECU software reset performed)

This topic last edited on 05/12/2016

JCB EcoMAX Help Files

P0612

Engine > Fault Codes > P0612

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine speed relay driver
Fault on the engine speed controller relay.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 138 of 319

3. Check machine side relay and circuit for faulty components, refer to engine speed controller.
4. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P0612-00 Short circuit

P0612-11 Short circuit to ground (SC2G)

P0612-12 Short circuit to battery (SC2VBAT)

P0612-13 Open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0615

Engine > Fault Codes > P0615

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Starter relay circuit
Fault on the starter motor control relay.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page starter motor inhibit relay.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 139 of 319

Related Fault FTB Codes


Fault Code Description

P0615-00 No sub type information

P0615-13 Open circuit (OC)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0616

Engine > Fault Codes > P0616

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Starter relay circuit low
Fault on the starter motor control relay.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page starter motor inhibit relay.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 140 of 319

P0616-19 Circuit current above threshold

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0617

Engine > Fault Codes > P0617

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Starter relay circuit high
Fault on the starter motor control relay.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page starter motor inhibit relay.

Related Fault FTB Codes


Fault Code Description

P0617-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 141 of 319

P062D

Engine > Fault Codes > P062D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel injector driver circuit performance
Fault on the fuel injector circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Injector short circuit


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P062D-00 No sub type information

P062D-11 Short circuit to ground (SC2G)

P062D-12 Short circuit to battery (SC2VBAT)

P062D-19 Circuit current above threshold

This topic last edited on 14/03/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 142 of 319

JCB EcoMAX Help Files

P062E

Engine > Fault Codes > P062E

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel injector driver circuit performance
Fault on the fuel injector circuit.

Information
ECU Engine ECU.

Effect Engine fails to start or stops if running.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P062E-00 No sub type information

P062E-11 Short circuit to ground (SC2G)

P062E-12 Short circuit to battery (SC2VBAT)

This topic last edited on 10/12/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 143 of 319

P062F

Engine > Fault Codes > P062F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Internal control module EPROM error
Memory fault detected on the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Incorrect or out of date ECU software.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Make sure that the ECU software is up to date. Refer to re-flashing an ECU.
4. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P062F-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 144 of 319

P0627

Engine > Fault Codes > P0627

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lift pump global fault
Fault on the lift pump control circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel lift pump test.

Related Fault FTB Codes


Fault Code Description

P0627-13 Open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0628

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 145 of 319

Engine > Fault Codes > P0628

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lift pump global fault
Fault on the lift pump control circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel lift pump test.

Related Fault FTB Codes


Fault Code Description

P0628-11 Short circuit to ground

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0629

Engine > Fault Codes > P0629

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 146 of 319

Related Fault FTB Codes

Fault Code Description


Lift pump global fault
Fault on the lift pump control circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel lift pump test.

Related Fault FTB Codes


Fault Code Description

P0629-12 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0630

Engine > Fault Codes > P0630

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


VIN not programmed or incompatible - ECM/PCM
Variant coding not programmed, incompatible or corrupted – ECM.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 147 of 319

Information
ECU Engine ECU.

Effect Engine features may not function correctly.

Possible Cause Variant coding not correctly configured.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check that the engine ECU software identification is correct for the machine type. Refer to re-flashing an
ECU.
2. If the software identification is not correct, carry out 'Restore Default'. Refer to re-flashing an ECU.
3. Re-flash the ECU. Make sure that the machine options and specifications are entered correctly.

Related Fault FTB Codes


Fault Code Description

P0630-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P0641

Engine > Fault Codes > P0641

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Sensor reference voltage "A" circuit/open
Fault with the power connections.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 148 of 319

Water or corrosion in connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine or machine, loose
connectors or poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU sensor supply.

Related Fault FTB Codes


Fault Code Description

P0641-00 No sub type information

This topic last edited on 01/04/2016

JCB EcoMAX Help Files

P0650

Engine > Fault Codes > P0650

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Malfunction Indicator Lamp (MIL) driver fault
Fault on the circuit controlling the malfunction indicator lamp (MIL).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty MIL.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 149 of 319

procedures. (SN0001)
1. Check operation of the lamp, refer to MIL test.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Code Description

P0650-00 No sub type information

P0650-11 Short circuit to ground (SC2G)

P0650-12 Short circuit to battery (SC2VBAT)

P0650-13 Open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0651

Engine > Fault Codes > P0651

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Sensor reference voltage "B" circuit/open
Fault with the power connections.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 150 of 319

connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU sensor supply.

Related Fault FTB Codes


Fault Code Description

P0651-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0655

Engine > Fault Codes > P0655

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Check Engine Lamp (CEL) fault
Fault on the circuit controlling the check engine lamp (CEL).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connectors.


Faulty CEL.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check operation of the lamp, refer to CEL test.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 151 of 319

Related Fault FTB Codes


Fault Code Description

P0655-0 No sub type information

P0655-11 Short circuit to ground (SC2G)

P0655-12 Short circuit to battery (SC2VBAT)

P0655-13 Open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0656

Engine > Fault Codes > P0656

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel level output circuit
Message fault from the fuel level switch.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 152 of 319

Fault Code Description

P0656 Message fault from the fuel level switch.

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0658

Engine > Fault Codes > P0658

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Actuator relay 1
Ground short circuit error has been detected for actuator relay 1 (heated DEF lines).

Information
ECU Aftertreatment system ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment ECU and heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P0658-14 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 153 of 319

JCB EcoMAX Help Files

P0659

Engine > Fault Codes > P0659

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Actuator relay 1
Battery short circuit error has been detected for actuator relay 1 (heated DEF lines).

Information
ECU Aftertreatment system ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment ECU and heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P0659-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0668

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 154 of 319

Engine > Fault Codes > P0668

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


PCM/ECM/TCM internal temperature sensor "A" circuit low
Internal temperature sensor fault on the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P0668-11 Short circuit to ground (SC2G)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0669

Engine > Fault Codes > P0669

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 155 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


PCM/ECM/TCM internal temperature sensor "A" circuit high
Internal temperature sensor fault on the engine electronic control unit (ECU).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU.

Related Fault FTB Codes


Fault Code Description

P0669-12 Short circuit to battery (SC2VBAT)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0685

Engine > Fault Codes > P0685

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


ECM/PCM power relay control circuit/open

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 156 of 319

Fault on the power hold relay for the engine electronic control unit (ECU).
This error code will be generated following a power hold relay test, or after adjusting the ECU calibration.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Power hold relay test carried out.
ECU calibration adjusted.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine ECU power hold relay.

Related Fault FTB Codes


Fault Code Description

P0685-00 no sub type information

P0685-72 Actuator stuck open

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0697

Engine > Fault Codes > P0697

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Sensor Reference Voltage "C" Circuit/Open
Sensor power supply fault.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 157 of 319

Information
ECU Engine ECU.

Effect Limp home mode.

Possible Cause Damaged harness or harness connectors.


Faulty ECU.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page ECU power connections.

Related Fault FTB Codes


Fault Code Description

P0697-00 No sub type information

P0697-4B Over temperature

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P06A7

Engine > Fault Codes > P06A7

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Sensor supply monitoring error through DCU
Fault with sensor supply voltage within the aftertreatment system ECU.

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 158 of 319

Effect

Possible Cause Damaged harness or harness connector.


Faulty ECU.
Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P06A7-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P0715

Engine > Fault Codes > P0715

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Input/turbine speed sensor "A" circuit
ECU power fault on the variable geometry turbocharger (VGT).

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 159 of 319

Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page VGT.

Related Fault FTB Codes


Fault Code Description

P0715-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1101

Engine > Fault Codes > P1101

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Rail pressure control error positive fault
Problem controlling the fuel rail pressure.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 160 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page general high pressure fuel system fault
table.

Related Fault FTB Codes


Fault Code Description

P1101-0 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1102

Engine > Fault Codes > P1102

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Rail pressure control error negative fault
Problem controlling the fuel rail pressure.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page general high pressure fuel system fault
table.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 161 of 319

Related Fault FTB Codes


Fault Code Description

P1102-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1103

Engine > Fault Codes > P1103

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Rail pressure fault
The fuel rail is not maintaining pressure after an engine shut down.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Fuel leak on the fuel rail.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page general high pressure fuel system fault
table.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 162 of 319

P1103-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1104

Engine > Fault Codes > P1104

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 3 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 3 due to environmental conditions.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P1104-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1105

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 163 of 319

Engine > Fault Codes > P1105

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 3 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 3 due to a fault within the update strategy.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P1105-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1106

Engine > Fault Codes > P1106

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 164 of 319

Injector 2 Update Fault


No minimum drive pulse (MDP) updates occurred on Injector 2 due to environmental conditions.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P1106-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1107

Engine > Fault Codes > P1107

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 2 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 2 due to a fault within the update strategy.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 165 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P1107-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1108

Engine > Fault Codes > P1108

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 4 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 4 due to environmental conditions.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 166 of 319

Fault Code Description

P1108-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1109

Engine > Fault Codes > P1109

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 4 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 4 due to a fault within the update strategy.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P1109-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P110A

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 167 of 319

Engine > Fault Codes > P110A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 1 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 1 due to environmental conditions.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P110A-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P110B

Engine > Fault Codes > P110B

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 168 of 319

Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector 1 Update Fault
No minimum drive pulse (MDP) updates occurred on Injector 1 due to a fault within the update strategy.

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - torque reduction.

Possible Cause Other fault codes present.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for other fault codes and repair as required.
2. Clear the fault codes.

Related Fault FTB Codes


Fault Code Description

P110B-00 No sub type information.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1400

Engine > Fault Codes > P1400

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Override switch
Fault with the override switch.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 169 of 319

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.


Faulty switch.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P1400-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1401

Engine > Fault Codes > P1401

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Override switch
Frame length error of PROSCR16 containing override switch information from engine electronic control unit
(ECU).

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 170 of 319

Effect Error code.

Possible Cause Damaged harness or harness connector.


Faulty switch.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P1401-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1402

Engine > Fault Codes > P1402

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Override switch
Frame timeout error has been detected by the override switch.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.


Faulty switch.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 171 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P1402-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P1500

Engine > Fault Codes > P1500

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Foot throttle/pedal signal fault
Fault on the foot throttle position sensor signal. For safety, the engine has gone into limp home mode.

Information

ECU Engine ECU.

Effect Reduced power mode (engine derate) - limp home mode.

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 172 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page foot throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P1500-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1501

Engine > Fault Codes > P1501

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Foot throttle/pedal signal fault
Fault on the foot throttle position sensor signal. For safety, the engine has gone into reduced torque mode mode.

Information

ECU Engine ECU.

Effect Reduced power mode (engine derate) - reduced torque mode.

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 173 of 319

3. Complete the testing procedure described in the component page foot throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P1501-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1503

Engine > Fault Codes > P1503

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Hand throttle/pedal signal fault
Fault on the hand throttle position sensor signal. For safety, the engine has gone into limp home mode.

Information

ECU Engine ECU.

Effect Reduced power mode (engine derate) - limp home mode.

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page hand throttle position sensor.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 174 of 319

Fault Code Description

P1503-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1504

Engine > Fault Codes > P1504

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Hand throttle/pedal signal fault
Fault on the hand throttle position sensor signal. For safety, the engine has gone into reduced torque mode.

Information

ECU Engine ECU.

Effect Reduced power mode (engine derate) - limp home mode.

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page hand throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P1504-00 No sub type information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 175 of 319

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P1506

Engine > Fault Codes > P1506

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle/pedal global fault - limp home mode
Fault on the throttle signal. For safety, the engine has gone into limp home mode,

Information
ECU Engine ECU.

Effect Reduced power mode (engine derate) - limp home mode.

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component pages foot throttle position sensor and hand
throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P1506-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 176 of 319

P1509

Engine > Fault Codes > P1509

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


CAN communication error on TSC
Error in the signal received from a CAN based throttle.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty throttle sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Electrical Network (CANBUS) Fault Table.
4. If no faults are found refer to machine information for diagnosing faults with the throttle controller system.

Related Fault FTB Codes


Fault Code Description

P1509-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 177 of 319

P1602

Engine > Fault Codes > P1602

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Starter motor relay global driver
Error with the voltage driver used to control the starter motor inhibit relay.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page starter motor inhibit relay.

Related Fault FTB Codes


Fault Code Description

P1602-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2000

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 178 of 319

Engine > Fault Codes > P2000

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Conversion efficiency
An error has been detected with the actual average conversion efficiency (below the threshold efficiency).

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause NOx sensors connected incorrectly.


Faulty sensor on the exhaust aftertreatment system.
Faulty exhaust aftertreatment catalyst.
Contaminated or incorrect fuel specification used

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes, repair as required.
2. Check that the upstream and downstream NOx sensors are connected correctly.
3. Check that the fuel is not contaminated and is to the correct specification. Refer to the operators manual.
4. Perform SCR Catalyst testing procedure.
5. Perform the exhaust aftertreatment catalyst refresh procedure. Refer to the machine operators manual.
6. If fault persists, raise a Techweb Helpdesk call.

Related Fault FTB Codes


Fault Code Description

P2000-00 No sub type information (actual average conversion efficiency is below the threshold)

P2000-02 General signal failure (actual average conversion efficiency is below the threshold)

P2000-04 System internal failure (actual average conversion efficiency is below the threshold)

P2000-06 Algorithm based failure (actual average conversion efficiency is below the threshold)

This topic last edited on 16/08/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 179 of 319

JCB EcoMAX Help Files

P202A

Engine > Fault Codes > P202A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF tank heater actuator power stage
Open load error of the urea tank heater has been detected.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P202A-13 Open load

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P202B

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 180 of 319

Engine > Fault Codes > P202B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF tank heater actuator power stage
Ground short circuit error of the DEF tank heater actuator.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P202B-14 Short circuit to ground or open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P202C

Engine > Fault Codes > P202C

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 181 of 319

Related Fault FTB Codes

Fault Code Description


DEF tank heater actuator power stage
Battery short circuit error of the DEF tank heater actuator.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P202C-13 Short circuit to battery or open circuit

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P202E

Engine > Fault Codes > P202E

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Dosing valve
This fault code indicates an error has been detected with the DEF dosing valve.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 182 of 319

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.


Faulty dosing control module.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Make sure that the engine ECU and the aftertreatment ECU are flashed with the latest software.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page dosing module.

Related Fault FTB Codes


Fault Code Description

P202E-00 No sub type information (Error on dosing valve short circuit)

P202E-02 General signal failure (Error on dosing valve plausibility)

P202E-4B Over temperature (Error on dosing valve driver over temperature)

P202E-12 Short circuit to battery (Error on dosing valve short circuit to battery)

P202E-13 Circuit open (Error on dosing valve short circuit to battery on high side or open load)

P202E-14 Short to ground or open circuit (Error on dosing valve short to ground or open circuit)

P202E-16 Dosing valve plausibility at low voltage (Error on dosing valve plausibility at low voltage)

This topic last edited on 16/12/2016

JCB EcoMAX Help Files

P203B

Engine > Fault Codes > P203B

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 183 of 319

Related Fault FTB Codes

Fault Code Description


Head unit
Multiple errors has been detected by the head unit.

Information
ECU Aftertreatment system ECU

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.


Faulty head unit.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Description
Code

P203B-00 No sub type information (Tank level signal error)

P203B-14 Circuit short to ground or open (DEF tank level signal is below minimum voltage limit)

P203B-15 Circuit short to battery or open (DEF tank level signal is above the maximum voltage limit)

P203B-16 Circuit voltage below threshold (Error on tank level plausibility)

P203B-22 Signal amplitude greater then maximum (Tank head unit level physical signal above maximum
limit)

P203B-81 Invalid serial data received (Can bus message error from head unit)

P203B-86 Signal invalid (Can bus message error for tank level from head unit)

P203B-87 Missing CAN message from engine ECU (CAN BUS off error from head unit)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P203F

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 184 of 319

Engine > Fault Codes > P203F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF tank
Low/empty DEF tank level error has been detected.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause DEF tank level low or empty.


Faulty DEF level sensor (head unit).
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. fill the DEF tank with DEF (to above 30%) and replace filler cap.
2. Switch on the ignition to check whether the fault has been fixed.
3. If fault remains, remove head unit and confirm DEF level with a dipstick.
4. Check that the sensor float on the head unit can move freely.
5. Complete the testing procedure described in the component page head unit.
6. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
7. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Code Description

P203F-7B Low fluid level (DEF tank level low and empty)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 185 of 319

P203F-21 Event information (Tank head unit level physical signal below minimum limit)

P203F-68 Signal amplitude less than minimum (DEF tank level low and below warning threshold)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2043

Engine > Fault Codes > P2043

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Head unit
CAN communication error has been detected between the head unit and aftertreatment system ECU.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description
Invalid serial data received (CAN BUS message error from head unit)
P2043-81
Signal invalid (DEF temperature message error from head unit)
P2043-86
Missing CAN message from ECU (CAN BUS off error from head unit)
P2043-87

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 186 of 319

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P204B

Engine > Fault Codes > P204B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF pressure line
Error has been detected with the DEF pressure line while monitoring for blockage.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.

Possible Cause DEF system pressure related problem.


Blocked dosing module.
Internal sensor failure.
Damaged harness or harness connector
.Def tank overfilled.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check all of the DEF lines for kinks or bends.
2. If a P204B-02 code has been generated and the machine is used mainly for low duty cycles, the fault may be
able to be cleared by working the machine harder periodically. Make sure that the ECU software is up to
date. Refer to bulletins and the machine help files for full details.
3. Remove the DEF lines and check for any signs of blockages or contamination.
4. Inspect the supply module filters (main filter and pre-filter). Replace the filters as required.
5. Make sure that the DEF tank has not been overfilled.
6. Perform the DEF dosing quantity test test and confirm the system is able to purge correctly.
7. Remove the dosing module and clean any deposits from the tip. Refer to dosing module.
8. Complete the testing procedure described in the component page supply module.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 187 of 319

9. If inducement is active and the machine is in forced idle, make sure the problem has been rectified. Start the
engine and operate the machine to load the engine and increase the exhaust temperature, the temperature
needs to exceed 150°C. This will allow the SCR system to prime and run through the diagnostic process,
once complete and all diagnostics have passed the fault will clear. This process can take up to 5 minutes. In
order to regain full power, follow the fault clearance procedure in reduced power mode (engine derate).

Related Fault FTB Codes


Fault Code Description

P204B-00 No subtype information (Error while monitoring the stabilisation of pressure)

P204B-02 General signal failure (Error on pressure line & dosing valve while monitoring for blockage)

P204B-16 Circuit voltage below threshold (Measured value of pressure sensor below the tolerable limit)

P204B-17 Circuit voltage above threshold (Measured value of pressure sensor above the tolerable limit)

P204B-26 Signal rate of change below threshold (Error on rate of pressure reduction )

P204B-29 Signal Invalid (Error on pressure line while monitoring for blockage)

P204B-61 Signal calculation failure (Error while monitoring of pressure buildup)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P204C

Engine > Fault Codes > P204C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Pump pressure signal
This fault code indicates an error with the pump pressure signal.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 188 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P204C-16 Circuit voltage below threshold (pump pressure signal below the minimum voltage limit)

P204C-21 Signal amplitude less than minimum (error for pump pressure physical signal below lower limit)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P204D

Engine > Fault Codes > P204D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Pump pressure signal range
This fault code indicates an error with the pump pressure signal range (above the maximum limit).

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 189 of 319

connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P204D-17 Circuit voltage above threshold (pump pressure signal above the maximum voltage limit)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P204F

Engine > Fault Codes > P204F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Blocked filter
Clogged filter in the supply module or DEF leak on the dosing system
OR
Repeat offence
An emission related fault code has become active within 40 engine running hours from being cleared

Information
ECU Engine/Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Repeat offence (P204F-9A).


Blocked DEF filter.
Aftertreatment system DEF leak.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 190 of 319

P204F-06, P204F-7A
1. Check the DEF hoses for signs of damage and any leaks.
2. Replace the DEF filter.
3. Complete the testing procedure described in the component page supply module.
4. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
5. Check the harness is not damaged and is routed correctly.
P204F-9A
1. Check for other fault codes and repair as required.
2. Perform system reset following 'Repeat Offence.' Refer to Reduced Power Mode (Engine Derate).

Related Fault FTB Codes


Fault Description
Code

P204F-06 Algorithm based failure - Aftertreatment DCU (Error to detect the clogged filter)

P204F-7A Fluid leak or seal failure - Aftertreatment DCU (Error to detect leakage during no dose)

P204F-9A Repeat offence active (an emission related fault code has become active within 40 engine running
hours)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P205B

Engine > Fault Codes > P205B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF tank header unit
Tank heater plausibility or response error detected.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 191 of 319

Possible Cause Damaged harness or harness connector.


Damaged, blocked or faulty coolant valve.
Failure of head unit.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check that the coolant valve is operating correctly and is not blocked, Refer to coolant valve.
2. Check that the coolant pipes to and from the DEF tank are routed correctly.
3. Check the DEF tank temperature value in SM, this should be close to ambient if the head unit is removed
and still electrically connected.
4. Check for any damaged or loose pins and debris or water inside the connector terminals of the
aftertreatment ECU, DEF tank header unit and DEF coolant valve. This may be as a consequence of
pressure washing the engine, loose connectors or poor connector sealing.
5. Check the harness is not damaged and is routed correctly.
6. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Description
Code

P205B-00 No subtype information (Error to indicate overheating of DEF tank due to coolant valve stuck open)

P205B-06 Algorithm based failure (Error in increase of DEF tank temperature to suggest coolant valve stuck
shut)

P205B-16 Circuit voltage above threshold (Tank head unit temperature physical signal below minimum limit)

P205B-17 Circuit voltage above threshold (Tank head unit temperature physical signal above maximum limit)

P205B-23 Signal stuck low (Error on tank temperature sensor plausibility below minimum threshold)

P205B-24 Signal stuck high (Error on tank temperature sensor plausibility exceeds maximum threshold)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P205C

Engine > Fault Codes > P205C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 192 of 319

Fault Code Description


Tank temperature signal voltage
Error with the temperature signal voltage, it is below the minimum limit.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.


Faulty head unit.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P205C-16 Circuit voltage below minimum limit

Algorithm based failure (Error in increase of DEF tank temperature)


This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P205D

Engine > Fault Codes > P205D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Tank temperature signal voltage
Error with the temperature signal voltage, it is above the maximum limit.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 193 of 319

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.


Faulty head unit.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P205D-17 Circuit voltage above maximum limit

Algorithm based failure (Error in increase of DEF tank temperature)


This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P205E

Engine > Fault Codes > P205E

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Tank temperature from head unit
Erroneous signal for aftertreatment 1 diesel exhaust fluid tank temperature.

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 194 of 319

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P205E-81 Tank temperature signal error (tank temperature signal error on CAN)

P205E-87 Missing CAN message from ECU (CAN BUS message error for tank temperature from head unit)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P207F

Engine > Fault Codes > P207F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF quality from head unit
Error for aftertreatment system diesel exhaust fluid property (quality) from tank head unit.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Poor quality DEF.


Contaminated DEF tank.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 195 of 319

Faulty quality sensor (head unit).


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
The quality sensor is active for 1 minute after the ignition is switched on and the DEF tank temperature is
above -2°C. Any contamination picked up during machine use will not be detected. The ignition
should always be switched off and the machine made safe before refilling the DEF tank.
1. Take a sample of DEF and confirm quality is with in spec. Refer to DEF quality test.
2. If DEF is not within spec the system must be drained and the complete aftertreatment system must be
cleaned.
3. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
4. Check the harness is not damaged and is routed correctly.
5. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P207F-00 No sub type information (DEF quality error during refill condition)

P207F-86 Signal Invalid (DEF concentration message error from head unit)

P207F-87 Missing CAN message (DEF quality message error from head unit)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2080

Engine > Fault Codes > P2080

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas temperature sensor circuit range/performance
Fault with the Variable Geometry Turbocharger (VGT) system.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 196 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page VGT.

Related Fault FTB Codes


Fault Code Description

P2080-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P208A

Engine > Fault Codes > P208A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Open load error of supply module pump motor
Open load error on the PWM output power stage for the actuator of the supply module pump motor

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 197 of 319

Possible Cause Damaged harness or harness connector.


Faulty supply module.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P208A-13 Circuit open (Open load error of supply module pump motor)

P208A31 No Signal (supply module pump feedback error)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P208B

Engine > Fault Codes > P208B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Error on supply module pump motor
Error on the PWM output powerstage for the actuator- Supply Module

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.


Faulty supply module.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 198 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P208B-02 General signal failure (error on supply module pump speed permanent deviation)

P208B-4B Over temperature (over temperature error of supply module pump motor)

P208B-21 Signal amplitude less than minimum (supply module internal duty cycle below min range)

P208B-22 Signal amplitude greater than maximum (supply module internal duty cycle in invalid range)

P208B-61 Signal calculation failure (error on supply module pump speed deviation)

P208B-84 Signal below allowable range (supply module motor speed duty cycle below minimum range)

P208B-85 Signal above allowable range (supply module motor speed duty cycle above maximum range)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P208C

Engine > Fault Codes > P208C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module pump motor
Short circuit to ground error of the supply module pump motor.

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 199 of 319

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.


Faulty supply module.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P208C-14 Short circuit to ground

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P208D

Engine > Fault Codes > P208D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module pump motor
Short circuit to battery error of the supply module pump motor.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.


Faulty supply module.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 200 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P208D-13 Short circuit to Battery

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P209F

Engine > Fault Codes > P209F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF tank heater
Error for over-temperature of the DEF tank heater power stage.

Information
ECU Aftertreatment system ECU

Effect Error code.

Possible Cause Faulty coolant valve


Faulty DEF tank temperature sensor (head unit)
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 201 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page coolant valve.

Related Fault FTB Codes


Fault Code Description

P209F-4B Over temperature

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20A0

Engine > Fault Codes > P20A0

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Back-flow pump
Open load error of the PWM output power stage of the DEF back-flow pump.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 202 of 319

Related Fault FTB Codes


Fault Code Description

P02A0-13 Open Load (Back flow pump actuator power stage)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20A1

Engine > Fault Codes > P20A1

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Back flow pump actuator power stage
Over temperature error at PWM output power stage of the DEF back flow pump.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty DEF pump (supply module).


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20A1-4B Over temperature

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 203 of 319

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20A2

Engine > Fault Codes > P20A2

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Back flow pump actuator power stage
Short circuit to ground error at PWM output power stage of the DEF back flow pump.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty DEF pump (supply module).


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20A2-14 Short circuit to ground

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 204 of 319

P20A3

Engine > Fault Codes > P20A3

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Back flow pump actuator power stage
Short circuit to battery error at PWM output power stage of the DEF back flow pump.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty DEF pump (supply module).


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20A3-13 Short circuit to battery

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20AD

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 205 of 319

Engine > Fault Codes > P20AD

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module temperature
Fault with the DEF supply module temperature sensor (dynamic plausibility.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty supply module.


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Description
Code

P20AD-06 Algorithm based failure (error on supply module temperature)

P20AD-21 Signal amplitude less than minimum (supply module temperature duty cycle below minimum range)

P20AD-22 Signal amplifier greater than maximum (supply module temperature duty cycle above maximum
range)

P20AD-92 Performance or incorrect operation (error on supply module temperature cold start)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20B5

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 206 of 319

Engine > Fault Codes > P20B5

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module heater actuator power stage
Open load error of the DEF supply module heater.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20B5-13 Open load

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20B6

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 207 of 319

Engine > Fault Codes > P20B6

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module heater
Error of the DEF supply module heater actuator power stage.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty supply module.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Description
Code

P20B6-4B Over temperature (Error for over temperature of supply module heater actuator power stage)

P20B6-21 Signal amplitude less than minimum (Supply module heater temperature duty cycle below minimum
range)

P20B6-22 Signal amplitude greater than maximum (Supply module heater temperature duty cycle above
maximum range)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20B7

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 208 of 319

Engine > Fault Codes > P20B7

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Short to ground of supply module heater actuator power stage
Short circuit to ground error of the DEF supply module.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20B7-14 Short circuit to ground

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20B8

Engine > Fault Codes > P20B8

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 209 of 319

Related Fault FTB Codes

Fault Code Description


Supply module heater actuator power stage
Error for the short circuit to battery of the DEF supply module heater.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20B8-13 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20B9

Engine > Fault Codes > P20B9

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Back flow line
Open load error on DEF heater relay back flow line.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 210 of 319

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20B9-00 No sub type information (Error for open load on heater relay of back flow line)

P20B9-13 Short circuit to battery (Open load error of DEF back flow line heater actuator power stage)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20BA

Engine > Fault Codes > P20BA

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF back flow line heater actuator power stage
Over temperature error of the DEF back flow line heater actuator power stage.

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 211 of 319

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20BA-4B Over temperature

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20BB

Engine > Fault Codes > P20BB

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Backflow Line Heater control / circuit fault
Short circuit to ground or open load error of the DEF heater relay circuit 4 (Backflow Line).

Information
ECU Aftertreatment system ECU.

Effect Error code.


Reduced Power Mode (Engine Derate).
Dosing interrupted if defrost/heating is required.

Possible Cause Fuse blown.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 212 of 319

Backflow line heater not connected properly.


Faulty hose heaters main relay.
Faulty backflow heated line relay.
Faulty backflow heated Line.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Complete the testing procedure described in the component page DEF Hose Heaters Main Relay Test. If
test fails, carry out the following checks:
1. Check the fuses.
2. Check the backflow line heater is connected properly.
3. Check the hose heaters main relay.
4. Check the backflow heated Line relay.
5. Check the continuity of the backflow line heater.
6. Check the harness is not damaged and is routed correctly.
7. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.

Related Fault FTB Codes


Fault Code Description

P20BB-00 No sub type information (error for short to ground or open load on heater relay of back flow line)

P20BB-14 Short to ground (error for short to ground of DEF back flow line heater actuator power stage)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20BC

Engine > Fault Codes > P20BC

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 213 of 319

Short to battery of DEF back flow line heater actuator power stage
Error for short circuit to battery of the DEF back flow line heater actuator power stage.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20BC-15 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20BD

Engine > Fault Codes > P20BD

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Heater relay 3 of pressure line
Open load error with the heater relay of the pressure line.

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 214 of 319

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20BD-00 No sub type information

P20BD-13 Open load

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20BE

Engine > Fault Codes > P20BE

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module heater
Error with the supply module heater plausibility or reduced DEF heating capability.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connectors.


Line heater relays or power relay fault.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 215 of 319

Internal supply module continuity fault.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes. Repair as required.
2. Check for any damaged or loose pins and debris or water inside the supply module and aftertreatment ECU
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page supply module.

Related Fault FTB Codes


Fault Code Description

P20BE-00 No sub type information (Error on supply module heater )

P20BE-02 General signal failure (Error on supply module heater temperature sensor)

P20BE-4B Over temperature (Error for over temperature of DEF pressure line heater actuator power stage)

P20BE-05 System programing failure (Error on supply module heater temperature cold start)

P20BE-13 Circuit Open (Error on relays for short to battery)

P20BE-93 No operation (Error on pressure line to perform after run )

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20BF

Engine > Fault Codes > P20BF

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Pressure Line Heater control / circuit fault
Short circuit to ground or open load error of the DEF heater relay circuit 3 (Pressure Line).

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 216 of 319

ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.
Dosing interrupted if defrost/heating is requested.

Possible Cause Fuse blown.


Pressure line heater not connected properly.
Faulty hose heaters main relay.
Faulty pressure heated line relay.
Faulty pressure heated line.
Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Complete the testing procedure described in the component page DEF Hose Heaters Main Relay Test. If
test fails, carry out the following checks:
2. Check the fuses.
3. Check the pressure line heater is connected properly.
4. Check the hose heaters main relay.
5. Check the pressure heated line relay.
6. Check the continuity of the pressure line heater.
7. Check the harness is not damaged and is routed correctly.
8. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.

Related Fault FTB Codes


Fault Code Description

P20BF-00 No sub type information

P20BF-14 Short to ground

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20C0

Engine > Fault Codes > P20C0

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 217 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF pressure line heater actuator power stage
Short circuit error to battery of the DEF pressure line heater power stage.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20C0-15 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20C1

Engine > Fault Codes > P20C1

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 218 of 319

Heater relay of suction line


Open load to ground error of the DEF heater relay 5 (suction line).

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20C1-00 No sub type information

P20C1-13 Open load error of DEF suction line heater actuator power stage

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20C2

Engine > Fault Codes > P20C2

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF suction line heater actuator power stage
Over temperature error of the DEF suction line heater actuator power stage.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 219 of 319

ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20C2-4B Over temperature

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20C3

Engine > Fault Codes > P20C3

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Suction Line Heater control / circuit fault
Short circuit to ground or open load error of the DEF heater relay circuit 5 (suction line).

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.
Dosing interrupted if defrost/heating is requested.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 220 of 319

Possible Cause Fuse blown.


Suction line heater not connected properly.
Faulty hose heaters main relay.
Faulty suction heated line relay.
Faulty suction heated line.
Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Complete the testing procedure described in the component page DEF Hose Heaters Main Relay Test. If
test fails, carry out the following checks:
2. Check the fuses.
3. Check the suction line heater is connected properly.
4. Check the hose heaters main relay.
5. Check the suction heated line relay.
6. Check the continuity of the suction line heater.
7. Check the harness is not damaged and is routed correctly.
8. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.

Related Fault FTB Codes


Fault Code Description

P20C3-00 No sub type information (error for short to ground or open load on heater relay of suction line)

P20C3-14 Short circuit to ground (error for short to ground of DEF suction line heater actuator power stage)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20C4

Engine > Fault Codes > P20C4

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 221 of 319

Fault Code Description


DEF suction line heater actuator power stage
Short circuit to battery error of the DEF suction line heater actuator power stage.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20C4-15 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20E8

Engine > Fault Codes > P20E8

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Under pressure error in metering control state
Under pressure error has been detected in the metering control state.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 222 of 319

ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Blockage in DEF line.


DEF tank Empty.
Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check DEF level.
2. If there is DEF present, check DEF lines for damage or kinks.
3. Check DEF backflow line for blockages.
4. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
5. Check the harness is not damaged and is routed correctly.
6. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20E8-84 Under pressure

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20E9

Engine > Fault Codes > P20E9

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Supply module/metering state
Overpressure error regardless of the state.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 223 of 319

ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Blockage in DEF line.


Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check DEF lines for damage or kinks.
2. Check DEF backflow line for blockages.
3. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
4. Check the harness is not damaged and is routed correctly.
5. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P20E9-00 No sub type information

P20E9-85 Overpressure in metering control state

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P20EA

Engine > Fault Codes > P20EA

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DCU relay early opening
Error with the power hold relay of the aftertreatment system ECU early opening.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 224 of 319

ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.


Faulty power hold relay.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P20EA-72 Early opening

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P20EB

Engine > Fault Codes > P20EB

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Aftertreatment system ECU relay stuck
Power hold relay of the aftertreatment system ECU is stuck.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connectors.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 225 of 319

Faulty power hold relay.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P20EB-71 Actuator stuck

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2100

Engine > Fault Codes > P2100

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle H-Bridge wiring fault
An intermittent or permanent break in the circuit powering the throttle motor has been detected.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.

Possible Cause Throttle harness connector removed.


Damaged harness or harness connector.
Electrical fault with the intake throttle.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 226 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. With both the engine ECU and the intake throttle electrical connectors removed, check the electrical
continuity between the following:
a. Throttle connector pin 1 and ECU connector pin 57.
b. Throttle connector pin 2 and ECU connector pin 60.
Refer to Intake Throttle for schematics and pin identification.
4. If no wiring faults exist and the fault remains, replace the intake throttle.

Related Fault FTB Codes


Fault Code Description

P2100-02 Throttle short circuit

P2100-13 Permanent or intermittent open circuit.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2101

Engine > Fault Codes > P2101

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle H-Bridge wiring fault
Permanent or intermittent short circuit.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate), error code

Possible Cause Damaged harness or harness connector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 227 of 319

Electrical fault with the intake throttle.

Service Procedure
Important: Use the multi-meter on the harness connector pins. DO NOT use the meter on the ECU pins. (SN0011)
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Disconnect both the engine ECU connector and the Intake throttle connector.
4. Check for short circuits between pins 57 and 60 and the engine ECU connector and pins 1 and 2 at the inlet
throttle connector.
5. Check for short circuits or low resistance to earth.
6. Check for short circuits or low resistance to battery positive.
7. Check for short circuits or low resistance to pins 2, 3 and 5 within the throttle connector.
8. Replace throttle.

Related Fault FTB Codes


Fault Code Description

P2101-02 Permanent or intermittent short circuit.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2102

Engine > Fault Codes > P2102

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle H-Bridge wiring fault
A short circuit to ground in the circuit powering the throttle motor has been detected.

Information
ECU Engine ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 228 of 319

Effect Reduced Power Mode (Engine Derate), error code

Possible Cause Damaged harness or harness connector.


Electrical fault with the intake throttle.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. With both the engine ECU and the intake throttle electrical connectors removed, check the electrical
continuity between the following:
a. Throttle connector pin 1 and ECU connector pin 57.
b. Throttle connector pin 2 and ECU connector pin 60.
Refer to Intake Throttle for schematics and pin identification.
4. If the fault remains replace the intake throttle.

Related Fault FTB Codes


Fault Code Description

P2102-11 Short circuit to ground (SC2G)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2103

Engine > Fault Codes > P2103

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle H-Bridge wiring fault
A short circuit to the battery in the circuit powering the throttle motor has been detected.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 229 of 319

ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate), error code

Possible Cause Damaged harness or harness connector.


Electrical fault with the intake throttle.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. With both the engine ECU and the intake throttle electrical connectors removed, check the electrical
continuity between the following:
a. Throttle connector pin 1 and ECU connector pin 57.
b. Throttle connector pin 2 and ECU connector pin 60.
Refer to Intake Throttle for schematics and pin identification.
4. If the fault remains replace the intake throttle.

Related Fault FTB Codes


Fault Code Description

P2103-12 Short circuit to battery (SC2VBAT)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2120

Engine > Fault Codes > P2120

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Hand pedal signal track 1 fault
Fault on the signal from track 1 of the hand throttle position sensor.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 230 of 319

ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Hand throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P2120-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2125

Engine > Fault Codes > P2125

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Hand pedal signal track 2 fault
Fault on the signal from track 2 of the hand throttle position sensor.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 231 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Hand throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P2125-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2135

Engine > Fault Codes > P2135

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle/pedal position sensor/switch "A"/"B" voltage correlation
Fault on the throttle pedal position sensor.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connectors.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 232 of 319

2. Check the harness is not damaged and is routed correctly.


3. Complete the testing procedure described in the component page foot throttle position sensor.

Related Fault FTB Codes


Fault Code Description

P2135-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2138

Engine > Fault Codes > P2138

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Hand pedal signal correlation fault
Fault with the correlation between the two position signals from the hand throttle position sensor.

Information
ECU Engine ECU

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Hand throttle position sensor.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 233 of 319

P2138-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2147

Engine > Fault Codes > P2147

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector supply voltage fault
Fault with voltage supply for the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P2147-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 234 of 319

P2148

Engine > Fault Codes > P2148

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Injector supply voltage fault
Fault with voltage supply for the fuel injector.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page fuel injector.

Related Fault FTB Codes


Fault Code Description

P2148-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P219D

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 235 of 319

Engine > Fault Codes > P219D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF heater relay actuator power stage
Error has been detected with the DEF heater relay.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P219D-4B Over temperature (error for over temperature of DEF heater relay actuator power stage)

P219D-13 Open load (Open load error of DEF heater relay actuator power stage)

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P219E

Engine > Fault Codes > P219E

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 236 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF heater relay actuator power stage
Short circuit to battery error of the DEF heater relay power stage.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P219E-13 Short to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P219F

Engine > Fault Codes > P219F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF heater relay actuator power stage
Short circuit to ground error of the DEF heater relay power stage.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 237 of 319

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page heated DEF lines.

Related Fault FTB Codes


Fault Code Description

P219F-14 Short to ground

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P21A9

Engine > Fault Codes > P21A9

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Short circuit to battery of actuator relay 4
Short circuit error to battery error has been detected of actuator relay 4.

Information
ECU Aftertreatment system ECU.

Effect Error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 238 of 319

Possible Cause Electrical fault.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P21A9-12 Short to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P21AB

Engine > Fault Codes > P21AB

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Short circuit to ground of actuator relay 4
Short circuit error to ground error has been detected of actuator relay 4.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Electrical fault.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 239 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P21AB-14 Short to ground

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2200

Engine > Fault Codes > P2200

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Upstream NOx sensor
A wiring fault has affected the upstream NOx sensor.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.

Possible Cause 12 Volt NOx sensor fitted to a 24 Volt machine.


24 Volt NOx sensor fitted to a 12 Volt machine.
Faulty sensor.
Damaged harness or harness connector.

Open circuit and short circuit fault codes relate to wiring faults detected between the NOx sensor exhaust probe
and the Sensor Control Unit (SCU). The SCU is the unit that the machine wiring harness plugs into. As the
exhaust probe and SCU is a single item, an open or short circuit fault is likely to require sensor replacement.
Voltage fault codes relate to an error detected in the power supplied to the NOx sensor unit and suggest a
problem within the machine harness or power supply. As 12 and 24 volt sensors exist, check that the sensor
voltage shown on the SCU matches the machine voltage.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 240 of 319

The AdBlue tank and both NOx sensors use the same power source and relay.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page upstream NOx sensor.

Related Fault FTB Codes


Fault Code Description

P2200-00 No sub type information (upstream NOx sensor wire diagnosis-error in voltage supply)

P2200-02 General signal failure (upstream NOx sensor short circuit to ground or battery)

P2200-05 System programming failure (upstream NOx sensor self diagnostic )

P2200-11 Circuit short to ground (lambda signal below minimum for upstream NOx sensor)

P2200-12 Circuit short to battery (lambda signal above maximum limit for upstream NOx sensor)x

P2200-13 Open circuit (upstream NOx sensor open circuit)

P2200-61 Signal calculation failure (invalid signal from upstream NOx sensor after heater release)

P2200-63 Circuit/component protection time-out (upstream NOx sensor self diagnostic timeout)

P2200-94 Unexplained operation (upstream NOx sensor self diagnostic abort)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2201

Engine > Fault Codes > P2201

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Downstream NOx sensor
A wiring fault has affected the downstream NOx sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 241 of 319

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause 12 Volt NOx sensor fitted to a 24 Volt machine.


24 Volt NOx sensor fitted to a 12 Volt machine.
Faulty sensor.
Damaged harness or harness connector.

Open circuit and short circuit fault codes relate to wiring faults detected between the NOx sensor exhaust probe
and the Sensor Control Unit (SCU). The SCU is the unit that the machine wiring harness plugs into. As the
exhaust probe and SCU is a single item, an open or short circuit fault is likely to require sensor replacement.
Voltage fault codes relate to an error detected in the power supplied to the NOx sensor unit and suggest a
problem within the machine harness or power supply. As 12 and 24 volt sensors exist, check that the sensor
voltage shown on the SCU matches the machine voltage.
The AdBlue tank and both NOx sensors use the same power source and relay.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page downstream NOx sensor.

Related Fault FTB Codes


Fault Code Description

P2201-00 No sub type information. (Downstream NOx sensor wire diagnosis-error in voltage supply)

P2201-1C Circuit voltage out of range (Downstream NOx sensor short circuit to ground or battery)

P2201-06 Algorithm based failure (Downstream NOx sensor self diagnostic )

P2201-11 Circuit short to ground (Lambda signal below minimum limit for downstream NOx sensor)

P2201-12 Circuit short to battery (Lambda signal above maximum limit for downstream NOx sensor)

P2201-13 Open circuit (Downstream NOx sensor open circuit)

P2201-16 Circuit voltage below threshold (Downstream NOx offset min error detection)

P2201-17 Circuit voltage above threshold (Downstream NOx offset max error detection)

P2201-61 Signal calculation failure (Invalid signal from downstream NOx sensor after heater release)

P2201-63 Circuit/Component protection time-out (Downstream NOx sensor self diagnostic timeout)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 242 of 319

P2201-97 Circuit/Component protection time-out (Downstream NOx sensor self diagnostic timeout)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2202

Engine > Fault Codes > P2202

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


NOx sensor reading below minimum threshold
An error has been detected with the NOx sensor reading.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty sensor.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component pages upstream NOx sensor and downstream
NOx sensor.

Related Fault FTB Codes


Fault Code Description

P2202-00 No sub type information (Upstream NOx sensor reading below minimum threshold)

P2202-16 Circuit voltage below threshold (Downstream NOx sensor reading below minimum threshold)

This topic last edited on 27/05/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 243 of 319

JCB EcoMAX Help Files

P2203

Engine > Fault Codes > P2203

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


NOx sensor reading above maximum threshold
An error has been detected with the NOx sensor reading.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty sensor.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component pages upstream NOx sensor and downstream
NOx sensor.

Related Fault FTB Codes


Fault Description
Code

P2203-00 No sub type information.(Upstream NOx sensor reading exceeds above maximum threshold)

P2203-17 Circuit Voltage above threshold (Downstream NOx sensor reading exceeds above maximum
threshold)

This topic last edited on 27/05/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 244 of 319

JCB EcoMAX Help Files

P2208

Engine > Fault Codes > P2208

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Downstream NOx sensor
An error has been detected with the downstream NOx sensor heater.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.

Possible Cause Sensor power supply fault.


Faulty sensor.
Damaged harness or harness connector.

Heater fault codes can be caused by a faulty NOx sensor power supply. Always resolve any voltage error fault
codes before rechecking and resolving heater fault codes.
The DEF tank and both NOx sensors use the same power source and relay.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes. Repair as required.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page downstream NOx sensor.

Related Fault FTB Codes


Fault Code Description

P2208-00 No sub type information (downstream NOx sensor heater not available)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 245 of 319

P2208-02 General signal failure (downstream NOx sensor heater not heated quickly)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2209

Engine > Fault Codes > P2209

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Upstream NOx sensor
An error has been detected with the upstream NOx sensor heater.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.

Possible Cause Sensor power supply fault.


Faulty sensor.
Damaged harness or harness connector.

Heater fault codes can be caused by a faulty NOx sensor power supply. Always resolve any voltage error fault
codes before rechecking and resolving heater fault codes.
The DEF tank and both NOx sensors use the same power source and relay.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes. Repair as required.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page upstream NOx sensor.

Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 246 of 319

Fault Code Description

P2209-00 No sub type information (upstream NOx sensor heater not available)

P2209-02 General signal failure (upstream NOx sensor heater not heated quickly)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2226

Engine > Fault Codes > P2226

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Barometric pressure sensor "A" circuit
Fault with the barometric/pressure sensor inside the ECU.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. The ECU temperature sensor cannot be tested. If fault persists, raise a Techweb Helpdesk call.

Related Fault FTB Codes


Fault Code Description

P2226-00 No sub type information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 247 of 319

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2228

Engine > Fault Codes > P2228

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Barometric pressure sensor "A" circuit low
Fault with the barometric/pressure sensor inside the ECU.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. The ECU temperature sensor cannot be tested. If fault persists, raise a Techweb Helpdesk call.

Related Fault FTB Codes


Fault Code Description

P2228-11 Short circuit to ground

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 248 of 319

P2229

Engine > Fault Codes > P2229

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Barometric pressure sensor "A" circuit high
Fault with the barometric/pressure sensor inside the ECU.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. The ECU temperature sensor cannot be tested. If fault persists, raise a Techweb Helpdesk call.

Related Fault FTB Codes


Fault Code Description

P2229-12 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2264

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 249 of 319

Engine > Fault Codes > P2264

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Water in fuel sensor circuit
Fault on the water in fuel sensor.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page water in fuel sensor.

Related Fault FTB Codes


Fault Code Description

P2264-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2265

Engine > Fault Codes > P2265

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 250 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


Water in fuel sensor circuit range/performance
Fault on the water in fuel sensor circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page water in fuel sensor.

Related Fault FTB Codes


Fault Code Description

P2265-2F Signal erratic.

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2266

Engine > Fault Codes > P2266

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Water in fuel sensor circuit low
Fault on the water in fuel sensor circuit.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 251 of 319

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page water in fuel sensor.

Related Fault FTB Codes


Fault Code Description

P2266-11 Short circuit to ground

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2267

Engine > Fault Codes > P2267

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Water in fuel sensor circuit high
Fault on the water in fuel sensor circuit.

Information
ECU Engine ECU.

Effect

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 252 of 319

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page water in fuel sensor.

Related Fault FTB Codes


Fault Code Description

P2267-12 Short circuit to battery

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2269

Engine > Fault Codes > P2269

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Water in fuel condition
Fault on the water in fuel sensor circuit.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Water in fuel.


Damaged harness or harness connector.
Faulty sensor.
Fuel hoses connected incorrectly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 253 of 319

Water in fuel sensor not disconnected.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for water in the fuel sedimenter, drain as required.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Make sure that the connector for water in fuel sensor is connected correctly.
5. Complete the testing procedure described in the component page water in fuel sensor.

Related Fault FTB Codes


Fault Code Description

P2269-00 No sub type information

P2269-22 Gross water contamination

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2413

Engine > Fault Codes > P2413

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Impeded EGR fault data engine ECU
Error with the exhaust gas recirculation valve.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate).


Error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 254 of 319

Possible Cause Engine related fault affecting EGR flow (Intake throttle, EGR, VGT, Coolant
temp, blocked SCR)
CAN communication fault.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes, correct as required.
2. Make sure the software is up to date and ECU is operating correctly.
3. Complete the testing procedure described in the component page CAN communication error.
4. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
5. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Description
Code

P2413-81 Invalid serial data received (CAN BUS message error for EGR faults from engine ECU)

P2413-86 Signal invalid (CAN BUS message error from engine ECU)

P2413-87 Missing CAN message from ECU (impeded EGR fault data or bus off for EGR faults from engine
ECU)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2428

Engine > Fault Codes > P2428

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust Catalyst Temperature
Error with the exhaust catalyst temperature t4 physical signal, it is above the maximum

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 255 of 319

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty Sensor


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page pre SCR exhaust temperature sensor.

Related Fault FTB Codes


Fault Code Description

P2428-00 No sub type information

P2428-17 Circuit voltage above threshold

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P242B

Engine > Fault Codes > P242B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Upstream temperature sensor
An error has been detected with the upstream temperature sensor static plausibility.

Information
ECU Aftertreatment system ECU.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 256 of 319

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust temperature sensor.

Related Fault FTB Codes


Fault Description
Code

P242B-00 No sub type information. (error on SCR catalyst upstream temperature sensor static plausibility)

P242B-16 Circuit voltage below threshold (error on catalyst temperature sensor plausibility below min
threshold)

P242B-17 Circuit voltage above threshold (error on catalyst temperature sensor plausibility above max
threshold)

P242B-23 Signal stuck low (exhaust catalyst temperature t4 physical signal below minimum limit)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P242C

Engine > Fault Codes > P242C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Upstream temperature sensor T4 voltage signal
An error has been detected with exhaust catalyst temperature t4 voltage signal, it is below the minimum limit

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 257 of 319

ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust temperature sensor.

Related Fault FTB Codes


Fault Code Description

P242C-16 Circuit voltage below threshold

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P242D

Engine > Fault Codes > P242D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust catalyst temperature T4 voltage signal
An error has been detected with the exhaust catalyst temperature t4 voltage signal, it is above the maximum limit.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 258 of 319

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page exhaust temperature sensor.

Related Fault FTB Codes


Fault Code Description

P242D-17 Circuit voltage above threshold

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2502

Engine > Fault Codes > P2502

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Power management from engine ECU
Error with power management.

Information
ECU Engine ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 259 of 319

2. Check the harness is not damaged and is routed correctly.


3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P2502-87 Missing CAN message from engine ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P250B

Engine > Fault Codes > P250B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil level sensor circuit range/performance
Fault on the oil level switch circuit.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page oil level switch.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 260 of 319

P250B-00 No sub type information

P250B-2F Signal erratic

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P250F

Engine > Fault Codes > P250F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine oil level too low
Low engine oil level.

Information
ECU Cluster

Effect

Possible Cause Low engine oil level.


Damaged harness or harness connector.
Faulty sensor.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check the engine oil level, top up as required.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Code Description

P250F-00 Signal Amplitude Less Than Minimum

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 261 of 319

P250F-86 Signal Invalid

P250F-87 Missing Message

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P256A

Engine > Fault Codes > P256A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine idle speed selector sensor/switch circuit/open
Fault on the engine speed controller.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty engine speed controller.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine speed controller.

Related Fault FTB Codes


Fault Code Description

P256A-00 No sub type information

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 262 of 319

JCB EcoMAX Help Files

P256B

Engine > Fault Codes > P256B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine idle speed selector sensor/switch range/performance
Fault on the engine speed controller.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty engine speed controller.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine speed controller.

Related Fault FTB Codes


Fault Code Description

P256B-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P256C

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 263 of 319

Engine > Fault Codes > P256C

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine idle speed selector sensor/switch circuit low
Fault on the engine speed controller.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty engine speed controller.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine speed controller.

Related Fault FTB Codes


Fault Code Description

P256C-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P256D

Engine > Fault Codes > P256D

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 264 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine idle speed selector sensor/switch circuit high
Fault on the engine speed controller.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.


Faulty engine speed controller.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page engine speed controller.

Related Fault FTB Codes


Fault Code Description

P256D-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P2620

Engine > Fault Codes > P2620

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Throttle position feedback fault

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 265 of 319

An intermittent or permanent fault has been detected within the throttle blade monitoring.

Information
ECU Engine ECU.

Effect

Possible Cause Throttle harness connector removed.


Damaged harness or harness connector.
Faulty inlet throttle.

Service Procedure
Important: Use the multi-meter on the harness connector pins. DO NOT use the meter on the ECU pins. (SN0011)
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Disconnect the inlet throttle harness connector.
4. With the ignition switched off, check for continuity between pin 4 at the inlet throttle connector and machine
earth.
5. With the ignition switched on, check for 5 volts at pin 5 of the harness connector relative to machine earth.
6. With the ignition switched on, check for 5 volts at pin 5 relative to pin 4 (ECU earth) at the inlet throttle
harness connector.
7. With the ignition switched on, check for 0 volts at pin 3 of the harness connector relative to machine earth.
8. With the ignition switched on, check for 0 volts at pin 3 of the harness connector relative to pin 4 (ECU
earth).
9. If a fault is detected in the pin 3 to 5 tests above, disconnect the black ECU connector and:
10. Check for continuity between: Throttle connector pin 3 and ECU connector pin 23.
11. Check for continuity between: Throttle connector pin 4 and ECU connector pin 13.
12. Check for continuity between: Throttle connector pin 5 and ECU connector pin 11.
Refer to intake throttle for pin identification.
13. If no wiring faults exist and the fault remains, replace the intake throttle.

Related Fault FTB Codes


Fault Code Description

P2620-00 Throttle position feedback fault

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 266 of 319

P2670

Engine > Fault Codes > P2670

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Short circuit to ground of actuator relay 2
A short circuit fault has been detected with the actuator relay 2.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P2670-14 Short circuit to ground or open circuit

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2671

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 267 of 319

Engine > Fault Codes > P2671

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Short circuit to battery of actuator relay 2
A short circuit fault has been detected with the actuator relay 2.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P2671-12 Short circuit to battery

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2685

Engine > Fault Codes > P2685

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 268 of 319

Related Fault FTB Codes

Fault Code Description


Short circuit to ground of actuator relay 3
A short circuit fault has been detected with the actuator relay 3.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P2685-14 Short circuit to ground or open circuit

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2686

Engine > Fault Codes > P2686

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Short circuit to battery of actuator relay 3
A short circuit fault has been detected with the actuator relay 3.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 269 of 319

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Aftertreatment system ECU.

Related Fault FTB Codes


Fault Code Description

P2686-12 Short circuit to battery

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2A00

Engine > Fault Codes > P2A00

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Upstream NOx sensor
A fault with the upstream NOx sensor has been detected , it is not mounted.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 270 of 319

Possible Cause Sensor unplugged.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page upstream NOx sensor.

Related Fault FTB Codes


Fault Code Description

P2A00-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2A01

Engine > Fault Codes > P2A01

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Downstream NOx sensor
A fault with the downstream NOx sensor has been detected , it is not mounted.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Sensor unplugged.


Damaged harness or harness connector.

Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 271 of 319

Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page downstream NOx sensor.

Related Fault FTB Codes


Fault Code Description

P2A01-00 No sub type information

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2BA7

Engine > Fault Codes > P2BA7

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF tank level
An error has been detected with the DEF level.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Warning light.

Possible Cause Low fluid level or empty DEF tank.


Faulty level sensor (head unit).
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check DEF level, top up as required.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 272 of 319

2. Test DEF tank level sender unit by filling the DEF tank to confirm maximum gauge reading. Check the DEF
tank level using Servicemaster diagnostic tool and compare to the dash level indicator on the machine.
3. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
4. Check the harness is not damaged and is routed correctly.

Related Fault FTB Codes


Fault Code Description

P2BA7-7B DEF level warning requested

P2BA7-F0 DEF level, level 2 requested - Forced idle (no throttle response) requested

P2BA7-68 DEF level, level 2 enacted - Forced idle (no throttle response) enacted

P2BA7-92 DEF level, level 1 enacted (25% torque derate enacted)

P2BA7-94 DEF level, level 1 requested (25% torque derate requested)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2BA8

Engine > Fault Codes > P2BA8

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF dosing
An error has been detected with the dosing of the DEF.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Warning light.

Possible Cause Fault preventing DEF injection.


Empty DEF tank.
Faulty dosing module.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 273 of 319

Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes, correct as required.
2. Complete the testing procedure described in the Dosing Module help page.
3. Make sure the software is up to date and ECU is operating correctly.

Related Fault FTB Codes


Fault Code Description

P2BA8-00 Interruption warning requested

P2BA8-F0 Interruption level 2 requested - Forced Idle (no throttle response) requested

P2BA8-68 Interruption level 2 enacted - Forced Idle (no throttle response) enacted

P2BA8-92 Interruption level 1 enacted (25% torque derate enacted)

P2BA8-94 Interruption level 1 requested (25% torque derate requested)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2BA9

Engine > Fault Codes > P2BA9

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF quality
An error has been detected with the quality of the DEF.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Warning light.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 274 of 319

Possible Cause Contaminated or poor quality DEF.


Faulty quality sensor.
Frozen DEF.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
The quality sensor is active for 1 minute after the ignition is switched on and the DEF tank temperature is
above -2°C. Any contamination picked up during machine use will not be detected. The ignition
should always be switched off and the machine made safe before refilling the DEF tank.
1. Perform DEF quality testing.
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Make sure the software is up to date and the ECU is operating correctly.
5. Check for additional fault codes, repair as required.

Related Fault FTB Codes


Fault Code Description

P2BA9-00 Quality Warning Requested

P2BA9-F0 Quality Level2 Requested - Forced Idle (no throttle response) requested

P2BA9-68 Quality Level2 Enacted - Forced Idle (no throttle response) enacted

P2BA9-92 Quality Level1 Enacted 25% (Torque derate enacted)

P2BA9-94 Tamper Level1 Requested 25% (Torque derate requested)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2BAA

Engine > Fault Codes > P2BAA

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 275 of 319

Fault Code Description


DEF consumption
An error has been detected with the DEF consumption level.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Warning light.

Possible Cause Damaged harness or harness connector.


Faulty dosing module.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or
poor connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Make sure the software is up to date and the ECU is operating correctly.
4. Perform DEF fluid quality Testing.

Related Fault FTB Codes


Fault Code Description

P2BAA-00 Consumption Warning Requested

P2BAA-F0 Consumption Level2 Requested - Forced Idle (no throttle response) requested

P2BAA-68 Consumption Level2 Enacted - Forced Idle (no throttle response) enacted

P2BAA-92 Consumption Level1 Enacted (25% torque derate enacted)

P2BAA-94 Consumption Level1 Requested (25% torque derate requested)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2BAB

Engine > Fault Codes > P2BAB

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 276 of 319

Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas recirculation
An error has been detected with the exhaust gas recirculation control unit.

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate).


Warning light.

Possible Cause Engine related fault affecting EGR flow (intake throttle, EGR, VGT, coolant
temperature, blocked SCR catalyst).
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for additional fault codes, correct as required.
2. Make sure the software is up to date and ECU is operating correctly.

Related Fault FTB Codes


Fault Code Description

P2BAB-00 EGR warning requested

P2BAB-F0 EGR level 2 requested - Forced Idle (no throttle response) requested

P2BAB-68 EGR level 2 enacted - Forced Idle (no throttle response) enacted

P2BAB-92 EGR level 1 enacted (25% torque derate enacted)

P2BAB-94 EGR level 1 requested (25% torque derate requested)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P2BAE

Engine > Fault Codes > P2BAE

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 277 of 319

Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Aftertreatment system tampering
An error has been detected which suggests the aftertreatment system is working outside its design parameter.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).


Warning light.

Possible Cause Exhaust aftertreatment system has been modified or tampered with.
Repeat faults.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for signs of tampering, and additional fault codes. Correct as required.
2. Make sure the software is up to date and the ECU is operating correctly.

Related Fault FTB Codes


Fault Code Description

P2BAE-00 Tamper warning requested

P2BAE-F0 Tamper level 2 requested - Forced idle (no throttle response) requested

P2BAE-68 Tamper level 2 enacted - Forced idle (no throttle response) enacted

P2BAE-92 Tamper level 1 enacted (25% torque derate enacted)

P2BAE-94 Tamper level 1 requested (25% torque derate requested)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

P3401

Engine > Fault Codes > P3401

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 278 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF property
Excessive/ambient temperature for aftertreatment 1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty head unit.


Faulty coolant valve.
Excessive local ambient temperature.
Excessive temperature of DEF in return line.
Faulty temperature sensor.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Check the DEF quality is within tolerance. Refer to DEF Quality Test. If the DEF quality is within tolerance,
replace the head unit.

Related Fault FTB Codes


Fault Code Description

P3401-87 Missing CAN message from ECU

This topic last edited on 19/10/2015

JCB EcoMAX Help Files

P3402

Engine > Fault Codes > P3402

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 279 of 319

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF property
High concentration error has been detected for aftertreatment 1 SCR catalyst DEF properties.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty quality sensor.


Debris in DEF tank.
Coolant leak into DEF tank.
Contamination of DEF supplied to tank.
Addition of fluids other than DEF to tank.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3402-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3403

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 280 of 319

Engine > Fault Codes > P3403

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF property
Low concentration error has been detected for aftertreatment 1 SCR catalyst DEF properties.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty quality sensor.


Debris in DEF tank.
Coolant leak into DEF tank.
Contamination of DEF supplied to tank.
Addition of fluids other than DEF to tank.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3403-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3404

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 281 of 319

Engine > Fault Codes > P3404

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF property
An error has been detected for aftertreatment 1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty coolant valve.


Excessive local ambient temperature.
Excessive temperature of DEF in return line.
Faulty temperature sensor.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3404-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3405

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 282 of 319

Engine > Fault Codes > P3405

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF property
High temperature error for aftertreatment 1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty coolant valve.


Excessive local ambient temperature.
Excessive temperature of DEF in return line.
Faulty temperature sensor.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3405-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3406

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 283 of 319

Engine > Fault Codes > P3406

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF property
Low temperature error for aftertreatment 1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty coolant valve.


Very low local ambient temperature.
Excessive temperature of DEF in return line.
Faulty temperature sensor.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3406-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3407

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 284 of 319

Engine > Fault Codes > P3407

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF temperature
Open circuit sensor error has been detected for aftertreatment1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty sensor.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3407-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3408

Engine > Fault Codes > P3408

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 285 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF temperature
Sensor short circuit error has been detected for aftertreatment1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty sensor.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3408-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3409

Engine > Fault Codes > P3409

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF properties

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 286 of 319

Excessive ambient/operating level error has been detected for aftertreatment 1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Excessive ambient temperature.


Faulty temperature sensor.
Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3409-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3410

Engine > Fault Codes > P3410

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF properties
High DEF level error has been detected for aftertreatment 1 SCR DEF properties.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 287 of 319

ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty quality sensor.


Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3410-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3411

Engine > Fault Codes > P3411

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF properties
An error with the regent level too low for aftertreatment 1 SCR catalyst has been detected.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Faulty quality sensor.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 288 of 319

Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3411-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3412

Engine > Fault Codes > P3412

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF temperature
Tank level open circuit error has been detected for aftertreatment1 SCR catalyst

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 289 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

Related Fault FTB Codes


Fault Code Description

P3412-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3413

Engine > Fault Codes > P3413

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


DEF temperature
A short circuit error has been detected for aftertreatment 1 SCR catalyst.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page head unit.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 290 of 319

Related Fault FTB Codes


Fault Code Description

P3413-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3414

Engine > Fault Codes > P3414

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine ECU for boost pressure
Erroneous signal for engine boost pressure.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3414-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 291 of 319

JCB EcoMAX Help Files

P3415

Engine > Fault Codes > P3415

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


IC1 frame
Data length error for IC1 frame has been detected.

Information
ECU Aftertreatment system ECU

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3415-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3416

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 292 of 319

Engine > Fault Codes > P3416

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


IC1 frame
Time out error for IC1 frame has been detected.

Information
ECU Aftertreatment system ECU

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3416-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3417

Engine > Fault Codes > P3417

Fault Code Description


Information
Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 293 of 319

Related Fault FTB Codes

Fault Code Description


Intake temperature
Erroneous signal has been detected for Intake manifold temperature.

Information
ECU Engine ECU

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3417-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3418

Engine > Fault Codes > P3418

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Operation mode
Erroneous signal has been detected for operating mode request.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 294 of 319

Information
ECU Aftertreatment system ECU

Effect Error code.


Refresh function will not recognise the mode and wont start.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Engine ECU.

Related Fault FTB Codes


Fault Code Description

P3418-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3419

Engine > Fault Codes > P3419

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Particulate inlet pressure
An error has been detected with the particulate inlet pressure.

Information
ECU Aftertreatment system ECU.

Effect Error code.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 295 of 319

Possible Cause DPF sensor value wrongly transmitted.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page Engine ECU.

Related Fault FTB Codes


Fault Code Description

P3419-87 Missing CAN message from ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3420

Engine > Fault Codes > P3420

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Refresh error
Data length error for PROSCR3 frame received for refresh.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 296 of 319

1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3420-87 Missing CAN message from Engine ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3421

Engine > Fault Codes > P3421

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Refresh error
Time out error for PROSCR3 frame received for refresh.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 297 of 319

Related Fault FTB Codes


Fault Code Description

P3421-87 Missing CAN message from Engine ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3422

Engine > Fault Codes > P3422

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Soot load
Communication error, erroneous signal detcted from the CAN

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3422-87 Missing CAN message from engine ECU

This topic last edited on 08/09/2015

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 298 of 319

JCB EcoMAX Help Files

P3423

Engine > Fault Codes > P3423

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Exhaust gas
Erroneous signal has been detected for engine exhaust gas temperature.

Information
ECU Aftertreatment system ECU.

Effect Error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

P3423-87 Missing CAN message from engine ECU

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

P3424

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 299 of 319

Engine > Fault Codes > P3424

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


SCR catalyst status very high

Information
ECU Engine ECU.

Effect Fault code.

Possible Cause SCR running refresh not successful.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Perform the exhaust aftertreatment catalyst refresh procedure immediately. Refer to the machine operators
manual.

Related Fault FTB Codes


Fault Code Description

P3424-85 SCR catalyst partially blocked (overloaded). Signal above allowable range.

This topic last edited on 25/02/2016

JCB EcoMAX Help Files

P3425

Engine > Fault Codes > P3425

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


SCR catalyst status critical

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 300 of 319

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate), forced idle.

Possible Cause SCR running refresh not successful.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Perform the exhaust aftertreatment catalyst refresh procedure immediately. Refer to the machine operators
manual.

Related Fault FTB Codes


Fault Code Description

P3425-85 SCR catalyst fully blocked (plugged). Signal above allowable range.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U0001

Engine > Fault Codes > U0001

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


High speed CAN communication bus
CAN Communication Error.

Information
ECU Engine ECU.

Effect

Possible Cause Damaged harness or harness connector.

Service Procedure

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 301 of 319

Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U0001-00 No sub type information

This topic last edited on 08/09/2015

JCB EcoMAX Help Files

U0029

Engine > Fault Codes > U0029

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Error 250KbPs
An error with the CANBUS has been detected.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 302 of 319

3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U0029-87 CANBUS missing message (CANBBUS off error 250kbps)

U0029-88 CANBUS off (CANBBUS off error 250kbps)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U0073

Engine > Fault Codes > U0073

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Control module communication bus A off
An error with the CANBUS has been detected.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 303 of 319

U0073-81 Received network data in error.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U0100

Engine > Fault Codes > U0100

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lost Communication with ECM/PCM "A"
Fault on the CAN communication network.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U0100-81 Received network data in error.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 304 of 319

U0105

Engine > Fault Codes > U0105

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Fuel quantity from engine ECU
Error with the fuel quantity.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U0105-87 Missing CAN message from engine ECU

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U010A

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 305 of 319

Engine > Fault Codes > U010A

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lost communication with Exhaust Gas Recirculation (EGR) control module
Fault on the CAN communication network.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U010A-81 Received network data in error

U010A-88 Bus off

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U010C

Engine > Fault Codes > U010C

Fault Code Description

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 306 of 319

Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lost communication with turbocharger/supercharger module "A"
Fault on the CAN communication network.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U010C-81 Received network data in error

U010C-88 Bus off

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U010E

Engine > Fault Codes > U010E

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 307 of 319

Fault Code Description


Engine ECU/aftertreatment system ECU Communication
Communication error between the engine ECU and aftertreatment system ECU

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate) forced idle.

Possible Cause Repeat offence.


Faulty ECU.
Damaged harness or harness connector.

Service Procedure
Important: Use the multi-meter on the harness connector pins. DO NOT use the meter on the ECU pins. (SN0011)
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Description
Code

U010E- U010E FTB 0x87 Inducement BAM message time out. Missing message on CAN B, the 500k bus.
08 1. This fault is raised by the engine ECU when the Inducement BAM message sent from the DCU
has not been received by the engine ECU.
2. This message is on the 500k Dieselmax Engine CAN (that does the VGT, EGR, and now also
the Nox sensors and DEF tank header).
3. The DCU is not working, or not powered.
1. SM fault routines to test if the DCU is powered.
1. From the SM diag tool engine Aftertreatment System.
1. Check the "Aftertreatment ECU Connection" indicator on the Aftertreatment
System screen is green (not red)
1. A green indicator means the DCU is powered, with working software, and
communicating on the 250k CAN A machine CAN bus.
2. A red indicator means the DCU is either;
1. Not responding to Servicemaster requests. Restart SM, and
powercycle ECU.
2. Not powered. Ignition or power supply issue.
3. Does not have working software installed. Reflash.
3. There is a wiring fault with the 500k CAN bus.
4. SM fault routines to test the 500k CAN bus.
4. From SM engine ECU diag tool fault code screen, check for CAN
faults from: DCU, EGR, VGT.
2. Message time-outs from more than one module would indicate a fault with the 500k

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 308 of 319

CAN bus in to the engine ECU.


5. From SM DCU diag tool fault code screen, check for CAN faults from:
ECU, Nox sensors, DEF tank header,
3. Message time-outs from more than one module would indicate a fault with the 500k
CAN bus in to the DCU.

U010C- U010E FTB 0x08 Engine Rating message time out. Missing message on CANA, the 250k bus.
87 1. This fault is raised by the engine ECU when the power rating message sent from the DCU has
not been received by the engine ECU.
2. This message is on the 250k machine CAN bus.
3. The DCU is not working, or not powered.
1. SM fault routines to test if the DCU is powered.
1. From the SM diag tool engine Aftertreatment System (was aftertreatment System)
screen,
1. Check the "Aftertreatment ECU Connection" indicator on the Aftertreatment
System screen is green (not red)
1. A green indicator means the DCU is powered, with working software, and
communicating on the 250k CAN A machine CAN bus.
2. A red indicator means the DCU is either;
1. Not responding to Servicemaster requests. Restart SM, and
powercycle ECU.
2. Not powered. Ignition or power supply issue.
3. Does not have working software installed. Reflash.
3. There is a wiring fault with the 250k CAN bus.
4. SM fault routines to test the 250k CAN bus.
4. From the SM diag tool engine Aftertreatment System (was SCR
System) screen,
2. Check there are values displayed and the values change as the engine is run and/or
the ignition is cycled.
2. Frozen or blank values means SM ins not able to communicated with the DCU.
5. Not responding to Servicemaster requests. Restart SM, and powercycle
ECU.
6. Not powered. Ignition or power supply issue.
7. Does not have working software installed. Reflash.
8. Is not connected to the 250k CAN bus. Wiring issue.
3. Check the "Aftertreatment ECU Connection" indicator on the Aftertreatment
System screen is green (not red)
9. A green indicator means the DCU is powered, with working software, and
communicating on the 250k CAN A machine CAN bus.
10. A red indicator means the DCU is either;
11. Not responding to Servicemaster requests. Restart SM, and powercycle
ECU.
12. Not powered. Ignition or power supply issue.
13. Does not have working software installed. Reflash.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U0121

Engine > Fault Codes > U0121

Fault Code Description


Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 309 of 319

Service Procedure
Related Fault FTB Codes

Fault Code Description


Lost communication with Anti Lock Brake (ABS) control module
Fault on the CAN communication network.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U0121-81 Received network data in error

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U0140

Engine > Fault Codes > U0140

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lost communication with Machine ECU.
Aftertreatment refresh inhibit/force switch message missing.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 310 of 319

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate), forced idle.


Inducement code P2BAB-00 may be generated if SCR catylst refresh is unable
to be performed.

Possible Cause Damaged harness or harness connector.


Incorrect ECU software.
Faulty ECU.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Description
Code

U0140-87 1. This fault is raised by the engine ECU when the CM1 message sent from the Body Control
Module has not been received by the engine ECU.
2. This message is on the 250k machine CAN bus.
3. The Body Control Module is not working, or not powered.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U0401

Engine > Fault Codes > U0401

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Lost communication with Anti Lock Brake (ABS) control module
Fault on the CAN communication network.

Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 311 of 319

ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate).

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U0401-00 No sub type information

U0401-61 Signal calculation error (CAN BUS message error for modeled NOx from engine ECU)

U0401-81 Invalid signal data received (CAN BUS message error from engine ECU)

U0401-86 Signal invalid (CAN BUS message error from engine ECU)

U0401-87 Missing CAN message from ECU

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U040B

Engine > Fault Codes > U040B

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Invalid data received from Exhaust Gas Recirculation (EGR) control module
Fault on the CAN communication network.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 312 of 319

Information
ECU Engine ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U040B-00 EGR Power-up span out of range

U040B-96 EGR Actuator internal hardware error

U040B-97 EGR Valve or mechanism obstruction

U040B-98 EGR Actuator over temperature warning (> 120°C)

U040B-4B EGR Actuator over temperature alarm (> 130°C)

P0400-00 Fault on the exhaust gas recirculation (EGR) control system

This topic last edited on 04/10/2016

JCB EcoMAX Help Files

U040D

Engine > Fault Codes > U040D

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 313 of 319

Fault Code Description


Fault with Variable Geometry Turbochanger
Fault detected with the VGT electrical or mechanical system

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause VGT mechanism seized, damaged or obstructed.


Damaged harness or harness connector.
Actuator coolant flow blocked / restricted or low coolant level.
Actuator internal electrical fault.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Complete the testing procedure described on the component page Variable Geometry Turbocharger (VGT).
2. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
3. Check the harness is not damaged and is routed correctly.
4. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U040D-00 VGT Calibration span out of range

U040D-54 VGT Power-up span out of range

U040D-81 VGT CAN communication error

U040D-96 VGT Actuator internal error

U040D-97 VGT Mechanism obstruction

U040D-98 VGT Actuator over temperature

P0400-00 Fault on the exhaust gas recirculation (EGR) control system.

This topic last edited on 04/10/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 314 of 319

JCB EcoMAX Help Files

U040F

Engine > Fault Codes > U040F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


Engine rating mismatch
Error with a DCU message containing the engine power rating, it does not match that of the engine calibration.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate) torque reduction.

Possible Cause Repeat offence.


DCU or ECU had been swapped from another machine or re-flashed
incorrectly.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Using the SM tool, General tab, check the Engine System Number (ESN) values are the same for both the
ECU and DCU.
2. Flash the DCU and/or Engine ECU with the correct software for the machine.
3. Refer to the Re-flashing an ECU help page for more information

Related Fault FTB Codes


Fault Description
Code

U040F- U040F Engine power rating mismatch.


81 1. This fault code is raised by the engine ECU when a message from the DCU containing the
engine power rating is received by the engine ECU, but the power rating does not match that
contained in the engine calibration.
2. The CAN message has been received correctly by the engine ECU, there is not a problem with
the wiring.
3. The CAN message is on the 250k machine CAN bus.
4. The DCU is calibrated to contain the engine power, and the engine ECU is also calibrated to
match the engine power rating. (Note, this is not the SM Setup Tool engine power).

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 315 of 319

5. The fault is that the DCU calibration does not match the ECU calibration power rating.
1. A DCU or ECU has been swapped from another machine.
2. The machine has not been built correctly.
1. Using SM Setup Tool, General Tab. Check the ESN values are the same for both
engine ECU and DCU.
2. Flash the DCU and/or the engine ECU with the correct software for the machine.
3. The system has been tampered with.
3. Check for tampering such as after market ECUs on the 250k machine CAN bus.

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U059E

Engine > Fault Codes > U059E

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


CAN BUS communication error for messages from upstream NOx sensor to aftertreatment ECU.
An error has been detected with the upstream NOx sensor Can communication signal.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).

Possible Cause Sensor unplugged from harness.


Faulty sensor.
Damaged harness or harness connector.

NOx sensors, DEF tank, EGR and VGT all communicate on the same 500 BPS CAN BUS wires. The CAN BUS
consists of a CAN high and a CAN low wire.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 316 of 319

3. Complete the testing procedure described in the component page upstream NOx sensor.

Related Fault FTB Codes


Fault Descriptions
Code

U059E-00 No sub type information (CAN BUS message error for temp signal status from downstream NOx
sensor)

U059E-02 General signal failure (CAN BUS message error for NO2 level from upstream NOx sensor)

U059E-08 Bus signal/Message failure (CAN BUS message error for O2 signal status from upstream NOx
sensor)

U059E-9A Component or system operation conditions (CAN BUS message error for heater ratio from upstream
NOx sensor)

U059E-29 Signal invalid (CAN BUS message error from upstream NOx sensor)

U059E-62 Signal compare failure (CAN BUS message error for NH3 level from upstream NOx sensor)

U059E-81 Invalid serial data received (CAN BUS message error from upstream NOx sensor)

U059E-84 Signal below allowable range (CAN BUS message error for power signal status from upstream NOx
sensor)

U059E-86 Signal invalid (CAN BUS message error from upstream NOx sensor)

U059E-87 Missing CAN message from ECU (CAN BUS off error from upstream NOx sensor)

U059E-93 No operation (CAN BUS message error for NOx level from upstream NOx sensor)

U059E-94 Unexpected operation (CAN BUS message for error for O2 level from upstream NOx sensor)

U059E-97 Component or system operation obstructed or blocked (CAN BUS message error for NOx signal
status from upstream NOx sensor)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U059F

Engine > Fault Codes > U059F

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


CAN BUS communication error for messages from downstream NOx sensor to aftertreatment

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 317 of 319

ECU.
An error has been detected with the downstream NOx sensor CAN communication signal.

Information
ECU Aftertreatment system ECU.

Effect Reduced Power Mode (Engine Derate).

Possible Cause Faulty sensor.


Sensor unplugged from harness.
Damaged harness or harness connector.

NOx sensors, DEF tank, EGR and VGT all communicate on the same 500 BPS CAN BUS wires. The CAN BUS
consists of a CAN high and a CAN low wire.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page downstream NOx sensor.

Related Fault FTB Codes


Fault Descriptions
Code

U059F-00 No sub type information (CAN BUS message error for temp signal status from upstream NOx
sensor)

U059F-02 General signal failure (CAN BUS message error for no2 level from downstream NOx sensor)

U059F-08 Bus signal/Message failure (CAN BUS message error for o2 signal status from downstream NOx
sensor)

U059F-9A Component or system operating conditions (CAN BUS message error for heater ratio from
downstream NOx sensor)

U059F-29 Signal invalid (CAN BUS message error from downstream NOx sensor)

U059F-62 Signal compare failure (CAN BUS message error for nh3level from downstream NOx sensor)

U059F-81 Invalid serial data received (CAN BUS message error from downstream NOx sensor)

U059F-84 Signal below allowable range (CAN BUS message error for power signal status from downstream
NOx sensor)

U059F-86 Signal invalid (CAN BUS message error from downstream NOx sensor)

U059F-87 Missing CAN message from engine ECU (CAN BUS off error from downstream NOx sensor)

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 318 of 319

U059F-93 No operation (CAN BUS message error for NOx level from downstream NOx sensor)

U059F-94 Unexpected operation (CAN BUS message error for o2 level from downstream NOx sensor)

U059F-97 Component or system operation obstructed or blocked (CAN BUS message error for NOx signal
status from downstream NOx sensor)

This topic last edited on 27/05/2016

JCB EcoMAX Help Files

U3FFF

Engine > Fault Codes > U3FFF

Fault Code Description


Information
Service Procedure
Related Fault FTB Codes

Fault Code Description


SAE DTC does not exist - will require manufacturer's specific information
Fault on the CAN communication network.

Information
ECU Engine ECU/ aftertreatment ECU.

Effect Reduced Power Mode (Engine Derate), error code.

Possible Cause Damaged harness or harness connector.

Service Procedure
Important: Stop the engine and let it cool before you start work. Do not start the engine during the service
procedures. (SN0001)
1. Check for any damaged or loose machine earths and connector pins as well as debris or water inside the
connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor
connector sealing.
2. Check the harness is not damaged and is routed correctly.
3. Complete the testing procedure described in the component page CAN communication error.

Related Fault FTB Codes


Fault Code Description

U3FFF-00 No sub type Information

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019
Fault Codes Page 319 of 319

This topic last edited on 27/05/2016

file:///C:/Users/M%20L%20Engine/AppData/Local/Temp/~hh7A53.htm 10/8/2019