BAT Electrical Test Answers
BAT Electrical Test Answers
BAT Electrical Test Answers
2
`
22. Circuit breaker and relay are both 28. The longer the length of conductor
for short circuit protection _________
______________ (YES/NO) a. The lesser the resistance
b. The better the conductor
23. Resistance in parallel will produce c. The higher the resistance
__________ d. The higher the inductance
a. High resistance e. All of the above
b. Low resistance 29. Fuses are normally rated
c. Equal resistance in______________
d. All of the above a. Voltage
e. None of the above b. Ohms
24. Socket outlet can be connected in c. Farads
__________ d. Amperes
a. Radial and ring e. Resistivity
b. Ring and parallel 30. The best method of connecting a
c. Parallel and radial wire is:_____
d. Adjacent and alternate a. Using cellotape
e. Series and Parallel b. Using terminal block
25. . Transformer work on the principle of c. Using cable tie
a. Self-induction d. Using masking tape
b. Mutual induction e. None of the above
c. Conduction 31. An electric heater draws 3.5A from
d. None of the above a 110V source. The resistance of
26. Connecting live and neutral wire the heating element is
together will result to approximately ______________
______________ a. 385 ohms
a. Reduce voltage b. 38.5 ohms
b. Reduce current c. 385 ohms
c. Low resistance d. 3.1 ohms
d. Full current e. 31 ohms
e. Short circuit 32. …………….is used to monitor a 3-
27. On start up, induction motor draws phase line
current that is usually _______ its a. Phase failure relay
rated current b. Timer relay
a. equal c. Contactor
b. lesser d. Overload relay
c. 6 to 7 times e. All mentioned
d. 10 times 33. In a certain three wire Y-connected
e. 100 times generator, the phase voltages are
3
`
2kV. The magnitudes of the line 38. In a three-phase system, when the
voltages are______________ loads are perfectly balanced, the
a. 2000V neutral current is_____
b. 6000V a. zero
c. 666V b. one-third of maximum
d. 3464V c. two-third of maximum
e. 2001V d. at maximum
34. A certain appliance uses 350W. If it e. Infinity
is allowed to run continuously for
24 days, how many kilowatt-hours
of energy does it consume? 39. __________ is use to determine
a. 20.16kWh the speed of an electric motor
b. 201.6kWh a. tachometer
c. 2.01kWh b. megger
d. 8.4kWh c. thermocouple
e. 84kWh d. Voltmeter
35. Cable insulation damage in an e. Ammeter
electrical installation can result to 40. The best tool used to determine
__________ current draw by each phase of an
a. open circuit electric motor is _____
b. earth leakage fault a. ammeter
c. increase ability to conduct b. clamp meter
d. transformer fault c. oscilloscope
e. increase in earth resistance d. multimeter
36. One major advantage of star-delta e. megger meter
connection for industrial motor 41. the difference between induction
operation is ________ motor and synchronous motor is
a. low starting torque that induction motor is
b. low voltage starting a. not self-starting
c. reduced starting current b. self-starting
d. Increase the starting current c. costlier than synchronous
e. insulation damage d. can be used to correct power
37. When short circuit occurs factor
________ effect happen e. None mentioned
a. current become becomes zero 42. In a single phase motor system, the
b. voltage become minimal safety and control devise is
c. minimum current flows connected to the…………..
d. current flows in reserve direction a. common
e. maximum current flows b. start
c. run
4
`
d. common and start a. Direct on line
e. Start and common b. Star delta
43. Which is a standard connection for
three phase electric
motor______________
c. Direct connection to a 3-phase
d. Option (a) and (b)
e. Non mentioned
44. The act of converting ac to dc is called---RECTIFIER--------
46. ________RELAY________________
47. __________CONTACTOR________________________
48. ______________VOLTAGE MONITORING DEVICES____________________