PTS-1 controller
over fuel dispensers and ATG systems
for petrol stations

TECHNICAL GUIDE
(PCB board modification: PTS-1, revision: PTS-U5-v7)

Review date: 12 June, 2024


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONTENT
REVISION HISTORY ................................................................................................................................................ 6
PURPOSE OF THE DOCUMENT .............................................................................................................................. 7
TECHNICAL FEATURES ........................................................................................................................................... 8
Appointment ................................................................................................................................................. 8
General specification ..................................................................................................................................... 8
SUPPORTED BRANDS OF FUEL DISPENSERS AND REGISTER METERS ................................................................... 9
SUPPORTED BRANDS OF ATG SYSTEMS AND PROBES ........................................................................................10
BOARD CONNECTORS AND INTERFACES.............................................................................................................11
COMMUNICATION PORTS ...................................................................................................................................12
COMPLETE SET ....................................................................................................................................................13
CONNECTION TO POWER SUPPLY .......................................................................................................................14
CONNECTION TO CONTROL SYSTEM...................................................................................................................15
INSTALLATION REQUIREMENTS FOR PETROL STATION ......................................................................................16
CONNECTION TO FUEL DISPENSERS ...................................................................................................................18
CONNECTION TO ATG SYSTEMS AND PROBES ....................................................................................................19
SENDING OF PUMPS SALES DATA TO CONSOLES ...............................................................................................20
CONVERSION BETWEEN PUMPS PROTOCOLS ....................................................................................................21
CONVERSION BETWEEN ATG CONSOLES PROTOCOLS .......................................................................................22
MONITORING OVER FUEL DISPENSERS AND TANKS ...........................................................................................23
FUEL DISPENSERS SALES DATA FOR ATG CONSOLES FOR RECONCILIATION ......................................................24
PTS-1 CONTROLLER MULTI POS SYSTEMS OPERATION ......................................................................................25
PTS-1 CONTROLLER CONFIGURATION AND TESTING UTILITY ............................................................................26
General information .................................................................................................................................... 26
Scheme of connections ............................................................................................................................... 27
Starting PTS configuration utility ............................................................................................................. 27
Tab “General” .............................................................................................................................................. 28
Tab “Pumps configuration” ......................................................................................................................... 29
Tab “Probes configuration” ......................................................................................................................... 30
Tab “Parameters” ........................................................................................................................................ 31
Tab “Control” ............................................................................................................................................... 33
Tab “Logging” .............................................................................................................................................. 35
Tab “Firmware update” ............................................................................................................................... 40
Tab “Diagnostics ”........................................................................................................................................ 44
BUILT-IN PUMPs SIMULATOR .............................................................................................................................46
BUILT-IN ATG PROBEs SIMULATOR .....................................................................................................................48
PTS-1 controller API (APPLICATION PROGRAMMING INTERFACES) ...................................................................50
C and C++ API............................................................................................................................................... 51
C# PTS-1 controller configuration and testing utility .................................................................................. 53
C# application .............................................................................................................................................. 55
C# API........................................................................................................................................................... 57
Delphi API .................................................................................................................................................... 59
Java API ........................................................................................................................................................ 61
Python API ................................................................................................................................................... 63
Visual Basic .NET PTS-1 controller configuration and testing utility ........................................................... 65
Visual Basic .NET application ....................................................................................................................... 67
Visual Basic .NET API.................................................................................................................................... 69
PTS-1 controller COM-object for MS Windows OS ..................................................................................... 71
www.technotrade.ua page 2 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Visual Basic 6.0 application ......................................................................................................................... 72


PTS-1 controller UniPump communication protocol .................................................................................. 75
PTS-1 CONTROLLER SOFTWARE DEVELOPMENT KIT (SDK).................................................................................76
PTS-1 controller SDK appointment .............................................................................................................. 76
PTS-1 controller SDK structure .................................................................................................................... 77
PTS-1 controller SDK technical features ...................................................................................................... 77
Specification ............................................................................................................................................ 77
PTS-1 controller SDK connections scheme .................................................................................................. 78
UniPump pumps software simulator........................................................................................................... 79
Purpose .................................................................................................................................................... 79
Main view ................................................................................................................................................ 79
Configuration ........................................................................................................................................... 80
UniProbe ATG probes software simulator .................................................................................................. 82
Purpose .................................................................................................................................................... 82
Main view ................................................................................................................................................ 82
Configuration ........................................................................................................................................... 83
Open source PTS-1 controller .NET application (C# and VB.NET) ............................................................... 85
Purpose .................................................................................................................................................... 85
Start ......................................................................................................................................................... 86
Configuration of PTS-1 controller ............................................................................................................ 86
Main view ................................................................................................................................................ 88
Settings of fuel point icons ...................................................................................................................... 89
Reading of fuel point total counters........................................................................................................ 90
Settings .................................................................................................................................................... 91
Displaying ATG systems probes states .................................................................................................... 92
Settings of ATG probe icons .................................................................................................................... 93
TiT.PTS classes help file ........................................................................................................................... 94
PTS-1 controller test utilities ....................................................................................................................... 95
Purpose .................................................................................................................................................... 95
PTS terminal utility ...................................................................................................................................... 96
Purpose .................................................................................................................................................... 96
Step-by-step configuration of the PTS-1 controller SDK ............................................................................. 97
Purpose .................................................................................................................................................... 97
Step 1. Downloading of PTS-1 controller SDK software .......................................................................... 97
Step 2. Assembling PTS-1 controller SDK cabling and connection to computer ..................................... 97
Step 3. Starting of the PTS-1 controller configuration utility Pts_config.exe .......................................... 99
Step 4. Configuration of pump ports ..................................................................................................... 100
Step 5. Configuration of probes ports ................................................................................................... 101
Step 6. Configuration of PTS-1 controller parameters .......................................................................... 102
Step 7. Configuration of pumps parameters ......................................................................................... 103
Step 8. Configuration of pumps software simulator ............................................................................. 104
Step 9. Configuration of ATG probes software simulator ..................................................................... 106
Step 10. Control over pumps and ATG probes in PTS-1 controller configuration and testing utility ... 107
Step 11. Configuration of PTS-1 controller .NET application for control over pumps and ATG probes 109
EXAMPLES OF FUEL DISPENSERS CONNECTION SCHEMES ...............................................................................115
Gilbarco dispenser connection scheme..................................................................................................... 116
Wayne Dresser dispenser connection scheme (RS-485 interface) ........................................................... 119
Wayne Dresser dispenser connection scheme (current loop interface) ................................................... 120
Tatsuno (Japan) dispenser connection scheme ........................................................................................ 121
www.technotrade.ua page 3 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tatsuno Europe (former Benc) dispenser connection scheme ................................................................. 122


Tokheim dispenser connection scheme .................................................................................................... 123
Tokheim dispenser connection scheme (RS-485 interface) ...................................................................... 126
Tokheim India dispenser connection scheme ........................................................................................... 128
Nuovo Pignone dispenser connection scheme (RS-485 interface) ........................................................... 129
Nuovo Pignone dispenser connection scheme (4-wire current loop interface) ....................................... 130
Logitron dispenser connection scheme (3-wire current loop interface) .................................................. 131
Bennett dispenser connection scheme (RS-485 interface) ....................................................................... 132
Bennett dispenser connection scheme (2-wire current loop interface) ................................................... 133
Batchen Email dispenser connection scheme ........................................................................................... 134
Scheidt & Bachmann T20 dispenser connection scheme.......................................................................... 135
Coptron dispenser connection scheme ..................................................................................................... 136
Midco dispenser connection scheme ........................................................................................................ 137
Petrotec dispenser connection scheme .................................................................................................... 138
Galileo dispenser connection scheme ....................................................................................................... 139
Prowalco dispenser connection scheme ................................................................................................... 140
Emgaz Dragon / Fornovo LPG dispenser with EsiWelma pumphead connection scheme........................ 141
Maser dispenser connection scheme ........................................................................................................ 142
Petposan-S4 / Meksan-S4 / Europump-S4 / Yenen dispensers connection scheme ................................ 143
Yenen dispensers connection scheme ...................................................................................................... 144
Petposan-Beta / Europump-Beta dispensers connection scheme ............................................................ 145
EuroPump dispenser connection scheme ................................................................................................. 146
Mekser dispenser connection scheme ...................................................................................................... 147
Fuelsis dispenser connection scheme ....................................................................................................... 148
Mepsan Unimep dispenser connection scheme ....................................................................................... 149
Meksan / Wayne SU86 dispenser connection scheme ............................................................................. 150
Baransay dispenser connection scheme ................................................................................................... 151
2A LPG dispenser connection scheme....................................................................................................... 152
Falcon dispenser connection scheme........................................................................................................ 153
Tiger dispenser connection scheme .......................................................................................................... 154
Korea EnE (LG EnE) dispenser connection scheme ................................................................................... 155
Dong Hwa Prime dispenser connection scheme ....................................................................................... 156
Gallagher (PEC) dispenser connection scheme ......................................................................................... 157
Compac dispenser connection scheme ..................................................................................................... 158
Safe dispenser connection scheme ........................................................................................................... 159
MS Gas dispenser connection scheme ...................................................................................................... 160
Shibata dispenser connection scheme ...................................................................................................... 161
Aspro Develco dispenser connection scheme ........................................................................................... 162
HongYang dispenser connection scheme.................................................................................................. 163
Lanfeng dispenser connection scheme ..................................................................................................... 165
Sanki dispenser connection scheme ......................................................................................................... 166
Datian Machines dispenser connection scheme ....................................................................................... 168
Eaglestar dispenser connection scheme ................................................................................................... 169
Blue Sky dispenser connection scheme..................................................................................................... 170
Censtar dispenser connection scheme...................................................................................................... 171
Knipflow dispenser connection scheme .................................................................................................... 172
Changlong dispenser connection scheme ................................................................................................. 173
Zcheng Genuine Machines dispenser connection scheme ....................................................................... 174
Bailong dispenser connection scheme ...................................................................................................... 175
www.technotrade.ua page 4 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Topaz dispenser connection scheme ........................................................................................................ 176


Shelf dispenser connection scheme .......................................................................................................... 177
UniCon dispenser connection scheme ...................................................................................................... 178
Mechanical dispensers connection scheme .............................................................................................. 179
EXAMPLES OF ATG SYSTEMS CONNECTION SCHEMES .....................................................................................180
Gilbarco Veeder Root TLS consoles connection scheme ........................................................................... 181
Start Italiana console connection scheme................................................................................................. 181
Start Italiana wired probes connection scheme........................................................................................ 182
Start Italiana wireless probes connection scheme .................................................................................... 182
Alisonic wired probes connection scheme ................................................................................................ 183
Alisonic wireless probes connection scheme ............................................................................................ 183
Struna ATG system connection scheme .................................................................................................... 184
OPW Site Sentinel ATG system connection scheme ................................................................................. 184
Colibri ATG system connection scheme .................................................................................................... 185
Fafnir ATG system connection scheme ..................................................................................................... 185
Hectronic ATG probes connection scheme ............................................................................................... 186
Vega radar level meters............................................................................................................................. 186
Windbell magnetostrictive probes connection scheme ............................................................................ 187
North Falcon wired probes connection scheme ....................................................................................... 188
North Falcon wireless probes connection scheme.................................................................................... 188
PTS-1 CONTROLLER PCB BOARD .......................................................................................................................189
PCB board top view ................................................................................................................................... 189
PCB board bottom view ............................................................................................................................. 189
Board dimensions ...................................................................................................................................... 190
RS-232 PORT CABLE CONNECTOR .....................................................................................................................191
CERTIFICATES ....................................................................................................................................................192
ORDER INFORMATION ......................................................................................................................................193

www.technotrade.ua page 5 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

REVISION HISTORY

REV DATE BY SECTIONS DESCRIPTION


R01 2017.11.21 Evgeniy All First release of PTS-1 board revision
Vasyliev

R02 2018.06.09 Evgeniy All Minor fixes


Vasyliev

R03 2018.08.15 Evgeniy All Modification of PTS PCB board


Vasyliev

R04 2018.11.17 Evgeniy Supported communication protocols, Updated list of supported communication
Vasyliev examples of connection schemes protocols of fuel dispensers and ATG systems,
added examples of connection to fuel dispensers
and ATG systems

R05 2019.03.01 Evgeniy Supported input communication protocols Communication with PTS-1 controller using pump
Vasyliev and ATG consoles protocols

R06 2020.03.21 Evgeniy General information update Regular document review


Vasyliev

R07 2020.07.18 Evgeniy General information update Regular document review


Vasyliev

R08 2023.02.24 Evgeniy PTS-1 controller SDK PTS-1 controller SDK structure updated
Vasyliev

www.technotrade.ua page 6 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PURPOSE OF THE DOCUMENT


This Technical Guide is intended for studying of PTS-1 controller over fuel dispensers and ATG systems for
petrol stations. It contains basic information regarding its
− technical characteristics
− supported communication protocols of fuel dispensers and ATG systems
− board interfaces and connectors
− configuration
− supplied application programming interfaces (API)
− description, configuration and connection of PTS-1 controller software development kit (SDK)
− schemes of connection to fuel dispensers and ATG systems
− board schematics
− cabling
Information regarding connection to specific fuel dispensers and correspondent configuration of PTS-1
controller can be received upon request to Technotrade LLC company.
Given technical manual describes the latest hardware version of the PTS-1 controller board (PTS-1
controller PCB board modification PTS-1). Technical manuals of older versions of the PTS-1 controller board
(PTS-U5, PTS-U3, PTS-U2 and PTS-U) with their corresponding connection schemes can be downloaded
from PTS-1 controller web-page: https://www.technotrade.ua/fuel-pump-controller.html.
Due to a reason that PTS-1 controller firmware is constantly being developed in direction of improvement
of its possibilities, changes are possible in final version, which are not described in given Technical Guide.
During the system development process given Technical Guide is also expanded and updated and new
chapters are added. Latest version of this Technical Guide can be downloaded from the PTS-1 controller
web-page: https://www.technotrade.ua/fuel-pump-controller.html.
Technotrade LLC hereby permits reproduction of this document as may be required by any of the
customers or OEMs wishing to use it.
This document has been carefully prepared and is believed to be accurate. However, Technotrade LLC, its
employees and its agents do not assume responsibility for its use either directly or indirectly. Technotrade
LLC shall not be liable for technical or editorial errors or omissions which may appear in this document.
Technotrade LLC reserves a right to make changes to this document at any time without notice. Prospective
users of this document should contact Technotrade LLC at the time they wish to use PTS-1 controller
together with their products to become aware of any updates that may apply.
In case if you find any mistakes, omissions in this document or have any suggestions on improvements to
this document, please feel free to e-mail them to our support mailbox: [email protected]. We
will be grateful to you for this valuable information.
All technical questions regarding the PTS-1 controller are welcome to be asked on support mailbox:
[email protected]. Our support team will be glad to help you.

Also, you can call to us or visit us on:

Technotrade LLC
Ukraine, 04114 Kiev, Priorska str. 10, office 1
Tel: +38-044-502-46-55, +38-044-502-46-77
Web: www.technotrade.ua
Mail: [email protected]

www.technotrade.ua page 7 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

TECHNICAL FEATURES
Appointment
PTS-1 controller over fuel dispensers and ATG (automatic tank gauge) systems for petrol stations serves
as a protocols converter. It knows communication protocols of a great variety of fuel dispensers and ATG
probes and allows control over any of them in exactly the same way using its own input communication
protocol or popular pumps and ATG systems communication protocols. POS system (cash register, payment
terminal) should not matter what is the brand of fuel dispenser or ATG system connected – it simply
communicates to the PTS-1 controller the same way regardless the brand of fuel dispensers and ATG
systems used, PTS-1 controller undertakes all work on communication with fuel dispensers and ATG
systems using their native communication protocol and takes into account all their peculiarities.

This completely simplifies work for a POS system developer: by having implemented input common
communication protocol of PTS-1 controller the POS becomes able to provide control over any of fuel
dispensers and ATG systems supported by PTS-1 controller. PTS-1 controller itself converts input
communication protocol into proprietary communication protocols of fuel dispensers and ATG systems.
Thus, the time required for development of POS system for petrol stations is significantly reduced.
PTS-1 controller can be called a forecourt controller and can be used together with POS systems, cash
registers, OPTs (outdoor payment terminals) and other control systems for petrol stations in order to
provide control over fuel dispensers, LPG (liquified petroleum gas) dispensers, CNG (compressed natural
gas) dispensers and various brands of ATG systems at petrol stations and storage depots.
PTS-1 controller is supplied with a rich set of APIs (application programming interfaces) developed under
most popular programming languages and environments in order to provide comfortable and quick
implementation of the PTS-1 controller into control systems for petrol stations (POS system, cash register,
OPT terminal, etc).

General specification
## PARAMETER VALUE
1 Power supply voltage 12 V DC
2 Current consumption 400 mA max
3 Temperature range -40°C ÷ +80°C
4 Weight 120 g
5 Overall dimensions 85 x 58 x 30 mm

www.technotrade.ua page 8 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

SUPPORTED BRANDS OF FUEL DISPENSERS AND REGISTER METERS


1. 2A 51. HAKO 101. PETROMECCANICA
2. ACTRONIC 52. HITACHI 102. PETROTEC
3. ADAST (ADAMOV SYSTEMS) 53. HONG YANG 103. PROWALCO
4. AG WALKER 54. IFSF (dispensers) 104. PUMP CONTROL
5. AGIRA 55. IMW 105. PUMPTRONICS
6. ANGI International 56. INTERMECH 106. REAL-TECH
7. ARIEL 57. IPT 107. RIX
8. ASPRO 58. JANASI 108. S.A.M.P.I.
9. ASSYTECH 59. JAPAN ENERJUMP 109. SAFE
10. ASTRON 60. JAPAN TECH 110. SALZKOTTEN
11. AZT 61. KAISAI 111. SANKI
12. BAILONG 62. KALVACHA 112. SATAM EQUALIS S
13. BARANSAY 63. KIEVNIIGAZ 113. SAVEL
14. BATCHEN 64. KOREA ENE 114. SEA BIRD
15. BENNETT 65. KPG-2 115. SHELF
16. BLUE SKY 66. KRAUS 116. SCHEIDT&BACHMANN
17. CENSTAR 67. KRIPFLOW 117. SHIBATA
18. CETIL 68. KWANGSHIN 118. SLAVUTICH
19. CFT Clean Fuel 69. LAFON 119. SOMO PETRO
20. CHANGLONG 70. LANFENG 120. STABILIZING
21. COMPAC 71. LAOXU 121. STAR
22. COPTRON 72. LEARED 122. STAR-HIGH
23. CORITEC 73. LIQUID CONTROLS 123. TATSUNO (JAPAN)
24. DATIAN MACHINES 74. LG ENE 124. TATSUNO EUROPE
25. DEM G. SPYRIDES 75. LOGITRON (FORMER BENC)
26. DEVELCO 76. MAIDE 125. TATTAN
27. DIGITAL FLOW 77. MASER 126. TAURUS
28. DINT 78. MEKSAN / WAYNE SU86 127. TEKSER
29. DONG HWA PRIME 79. MEKSER 128. TERABAYT TEXNO SERVIS
30. DURULSAN 80. MEPSAN 129. TIGER
31. EAGLESTAR 81. MIDCO 130. TOKHEIM
32. ECOTEC 82. MIDCOM 131. TOKHEIM INDIA
33. EHAD 83. MITHRA FUELING 132. TOKICO
34. EKOSIS 84. MM PETRO (ZAP) 133. TOMINAGA
35. EMGAZ DRAGON 85. MOTOGAZ 134. TOPAZ
36. EPCO 86. MOUNTAIN CHINA 135. TOTAL CONTROL SYSTEMS
37. ESIWELMA 87. MRT 136. TRANSPONDER
38. EUROPUMP 88. MS GAS 137. TRUE TECH
39. FALCON LPG 89. NARA 138. UCAR ELEKTRIC
40. FLOW 90. NET FUN LEADER 139. UNICON-TIT
41. FORNOVO GAS 91. NUOVA MIGAS 140. VANZETTI
42. FUELQUIP 92. NUOVO PIGNONE 141. WAYNE DRESSER
43. FUELSIS 93. ONSUN 142. WAYNE PIGNONE
44. FUREN HIGHTECH 94. ORCA 143. WELLDONE MACHINES
45. GALILEO 95. PEC (GALLAGHER FUEL 144. WERTCO COMPANY TEC
46. GASLIN SYSTEMS) 145. WINTEC ENERGY
47. GERKON 96. PARKER 146. YENEN
48. GESPASA 97. PECO 147. ZCHENG GENUINE
49. GILBARCO 98. PEGASUS MACHINES
50. GREENFIELD 99. PETPOSAN 148. ZHONGSHENG
100. PETROEQUIP
* Some dispensers may demand using interface converter boards to RS-485 interface (depends on
electronics of used pumphead in dispenser).
www.technotrade.ua page 9 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

SUPPORTED BRANDS OF ATG SYSTEMS AND PROBES

1. ACCU 20. HUMANENTEC 39. PHOENIX


2. ALISONIC 21. IFSF (ATG systems) 40. QINGDAO GUIHE
3. ANHUI QIDIAN 22. INCON 41. RCS EPSILON
4. ASSYTECH 23. KACISE 42. RIKA
5. BLUESKY 24. KANGYU 43. SBEM
6. CENSTAR 25. KUNLUN 44. SENSOR
7. DUT-E 26. LABKO 45. SINOTECH
8. EAGLESTAR 27. LIGO 46. SKE LEVEL GAUGE
9. EBW 28. MECHATRONICS 47. START ITALIANA
10. EMERSON ROSEMOUNT 29. MEPSAN UNIMEP 48. STRUNA
11. ENRAF 30. METRIKEMP 49. TECHNOTON
12. ESCORT FD 31. MTS ATG SENSORS 50. TENET
13. FAFNIR 32. ND 51. UNIPROBE
14. FRANKLIN FUELING 33. NORTH FALCON 52. VEGA
15. GAMICOS 34. O.L.E. 53. VEPAMON
16. GILBARCO VEEDER ROOT 35. OKET 54. WINDBELL
17. HECTRONIC 36. OMNICOMM 55. XT SENSORS
18. HOLYKELL 37. OMNTEC 56. ZCHENG GENUINE
19. HONG YANG 38. OPW MACHINES
* Communication parameters (baud rate, parity control, data and stop bits) are configured for probe ports
in PTS-1 controller independently from used communication protocol

www.technotrade.ua page 10 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

BOARD CONNECTORS AND INTERFACES

PTS-1 controller is supplied together with terminal blocks for each of the connectors for screwing of
connection wires.

www.technotrade.ua page 11 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

COMMUNICATION PORTS

PORT NAME INTERFACE APPOINTMENT


Connection with control system (POS system, cash
RS-232
PC PORT (3 wires: TxD, RxD, Gnd)
register, OPT terminal, etc).
It is recommended to use shielded cable.
Connection with fuel dispensers using configurable
proprietary communication protocol (up to 16 fuel
Pump RS-485
dispensers). It is required to use shielded cable, which
port 1 (2 wires: line A, line B)
shield is connected to ground on the side of connected
pump.
Connection with fuel dispensers using configurable
proprietary communication protocol (up to 16 fuel
Pump RS-485
dispensers).
port 2 (2 wires: line A, line B)
It is required to use shielded cable, which shield is
connected to ground on the side of connected pump.
Connection with fuel dispensers using configurable
proprietary communication protocol (up to 16 fuel
PUMP PORTS

Pump RS-485
dispensers).
port 3 (2 wires: line A, line B)
It is required to use shielded cable, which shield is
connected to ground on the side of connected pump.
Connection with fuel dispensers using configurable
proprietary communication protocol (up to 16 fuel
Pump port RS-485
dispensers).
4 (2 wires: line A, line B)
It is required to use shielded cable, which shield is
connected to ground on the side of connected pump.
1. PTS-1 controllers interconnection (up to 16 PTS-1
controllers) for simultaneous control over the same
fuel dispensers and ATG systems
2. Connection with ATG systems (probes) using
DISP port RS-485
configurable proprietary com. protocol (up to 16 ATG
(RS-485) (2 wires: line A, line B)
probes)
It is required to use shielded cable, which shield is
connected to ground on the side of connected ATG
system (probe).
Connection with ATG system (console) using configurable
DISP port RS-232
proprietary communication protocol (up to 16 ATG
(RS-232) (3 wires: TxD, RxD, Gnd)
probes).
PROBE PORTS

1. Connection with ATG system (console) using


configurable proprietary communication protocol (up
RS-232
LOG port to 16 ATG probes)
(3 wires: TxD, RxD, Gnd)
2. Writing of operation log of PTS-1 controller interaction
with fuel dispensers, ATG systems, PTS interconnection
Connection with ATG system (console) using configurable
RS-232
USER port proprietary communication protocol (up to 16 ATG
(3 wires: TxD, RxD, Gnd)
probes).
NOTE!
It is strictly prohibited to connect any of the cables’ shields to ports of PTS-1 controller.

Manufacturer reserves a right to bring in modifications in construction of controller for improving of its
technical and functional characteristics, so supplied version of controller may differ from described in given
technical guide.

Warning! This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.

www.technotrade.ua page 12 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

COMPLETE SET

Depending on the order code (see section “Order information”) PTS-1 controller can be supplied either in a
view of electrical board (variant of controller supply PTS1-PCB-z), or installed in a mounting box with cables
inputs and a power switching button (variant of controller supply PTS1-BOX-z).

Variant of controller supply in a view of electrical board (PTS1-PCB-z)

Variant of controller supply installed in a metal box with cables inputs and a power switching button
(variant of controller supply PTS1-BOX-z)

www.technotrade.ua page 13 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONNECTION TO POWER SUPPLY

It is recommended to use non-shielded cable at connection to power supply. It is recommended to install a


ferrite ring core TDK ZCAT 2235-1030 on the power supply cable with 1 coil inside (as shown on image
below).

Ferrite ring coil should be located on the power supply cable nearby (up to 3 cm) the power supply
connector of controller board (in case if controller is supplied in a view of electrical board, variant of supply
PTS1-PCB-z) or nearby the power supply cable input of box (in case if controller is supplied in metal box,
variant of supply PTS1-BOX-z). After placing a ferrite ring on the power supply cable, it is required to check
correctness of its installation, it is possible to check it by moving ferrite ring along the power supply cable
by pushing power supply cable into it from one side and pulling the cable from another side of the ferrite
ring.

www.technotrade.ua page 14 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONNECTION TO CONTROL SYSTEM

Connection to the control system (POS system, cash register, OPT terminal, etc) is made through a PC port,
which has RS-232 interface (3 wires: TxD, RxD, Gnd).

Scheme of connections:

In case if the control system does not have a COM-port – it is possible to use any type of converter to COM-
port (like USB-to-COM, Ethernet-to-COM, Bluetooth-to-COM, other converters).

Communication with PTS-1 controller is made using commands and responses described in UniPump
communication protocol (own proprietary protocol of Technotrade LLC) – see document “UniPump
communication protocol specification for PTS-1 controller over fuel dispensers and ATG systems” for more
information. Thus, PTS-1 controller provides conversion of the common communication protocol UniPump
into various proprietary communication protocols of fuel dispensers and ATG systems.

www.technotrade.ua page 15 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

INSTALLATION REQUIREMENTS FOR PETROL STATION

WARNING! Manufacturer guarantees reliable and stable operation of products only at compliance with
below requirements. In case of absence of uninterruptible power supply or incorrect wiring of products
to it any claims to malfunction of software are not accepted.

1. Requirements to power supply

The described products come into structure of control system (POS) for petrol station. Power supply of the
products should be done from a separate power supply with built-in filter of radio frequency interferences
and limiter of high voltage pulse interferences. Power supply should have a safety factor of 1.5.

At emergency switching off the power supply or in case of power voltage exceeding its permitted ranges
the products can switch off with loss or corruption of data and possible damage of hardware and software.
Power supply of all electronic blocks of POS and electronic pumpheads of dispensers, which are connected
through information lines, should be made from single common uninterruptible power supply source (UPS).
Connection of other devices to given UPS is strictly prohibited. UPS should be of continuous action (online)
and work with double conversion with output voltage regulation. UPS should have a safety factor of 1.5.
Filter of radio frequency interferences and limiter of high voltage pulse interferences should be used for
feeding equipment from UPS.

Supply of electronic pumpheads of dispensers should be made from the UPS unit using 3-wires scheme
with isolated neutral through dedicated two-pole breaker for each dispenser. Connection of other parts of
dispenser to UPS unit (expect electronic pumpheads) is strictly prohibited.

UPS unit should be connected to a separate three-pole socket fed through the three-wire feeder (phase,
neutral, ground wires) with insulated neutral from a dedicated circuit breaker of switchboard. Feeder
coming from the switchboard to the socket should located not closer than 0.3 meters to other feeders. The
socket should be located at a distance of not more than 1 meter away from the POS. Phase wire of the
feeder should not have any other consumer, which are sources of interferences (for example motors).

For protection of POS and UPS from secondary effects of atmospheric electricity it is required to install
high-voltage arresters (dischargers) at the transformer substation or on poles of power lines.

2. Requirements to grounding

In the switchboard the ground wire of feeder socket should be connected to the grounding screw, which
should be connected by means of welding with a protection grounding circuit of petrol station by steel wire
with a diameter of not less than 5 mm.

Protection grounding circuit of petrol station should correspond to safety requirements and be separated
from the station lightning protection circuit. Distance from the nearest electrode of protection grounding
circuit to electrode of lightning protection circuit must be at least 10 meters. Resistance of the protection
grounding circuit should be not more than 4 Ohms and must be confirmed by the test report. Length of
wires from the switchboard to the nearest electrode of protection grounding circuit should not exceed 15
meters.

3. Requirements to laying of cable communications

Laying of power and information wires to dispensers should be done in separate pipes with distance of not
less than 0.3 meters between each other. For informational wires (current loops, RS-485, other interfaces)

www.technotrade.ua page 16 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

it is recommended to use shielded twisted-pair cables (recommended type – FTP CAT 5E). The cable shield
must be connected to the ground connector on one side only – on the side of the dispenser.

www.technotrade.ua page 17 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONNECTION TO FUEL DISPENSERS

PTS-1 controller can simultaneously control up to 16 fueling places (16 sides of 1-sided dispensers or 8 sides
of 2-sided fuel dispensers or mixture of 1-sided and 2-sided dispensers) that use up to 4 various
communication protocols (each of the pump ports can be adjusted to a separate communication protocol
and baud rate and can connect up to 16 fueling places) (see section “Examples of connection to fuel
dispensers”).

So, you can connect in total 16 pumps to the same pump port or you can distribute all the 16 pumps
between the any of the pump ports.

NOTE: if there are less than 4 various types of fuel dispensers at petrol station (which use various
communication protocols) then it is recommended to distribute fuel dispensers between 4 PTS-1 controller
ports in approximately equal quantities in order to minimize delays between fuel dispensers querying in the
same pump port.

www.technotrade.ua page 18 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONNECTION TO ATG SYSTEMS AND PROBES

PTS-1 controller can simultaneously control up to 16 ATG probes (gauges) (separate probes or probes
connected to ATG systems / consoles) that use up to 3 various communication protocols (each of the probe
ports can be adjusted to a separate communication protocol and baud rate and connect up to 16 ATG
probes) (see section “Examples of connection to ATG systems”).

NOTE: DISP port provides a possibility to connect ATG system (probes) over either RS-485 or RS-232
interfaces – interface is selected using a configuration parameter in PTS-1 controller.

www.technotrade.ua page 19 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

SENDING OF PUMPS SALES DATA TO CONSOLES

At communication to ATG consoles PTS-1 controller can be used for sending fuel dispensers sales data to
consoles in order to make console provide tanks reconciliation reports and automatic tanks calibration:

www.technotrade.ua page 20 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONVERSION BETWEEN PUMPS PROTOCOLS

In case if POS system already knows some open communication protocol of dispensers then it can use PTS-
1 controller for its conversion to any other pump protocols without any additional integration.

Communication of PTS-1 controller with control system (POS system, cash register, OPT terminal, etc) for
provision of control over dispensers can be done using popular open pump protocols. At this connection is
made through one of the pump ports, which has RS-485 interface (2 wires: A, B). Any of the pump ports can
be configured to work as input port for communication with control system.

Scheme of connections:

In this case the control system should know pump communication protocol. PTS-1 controller in this case
serves as a protocols converter: converts input pump protocol into any other supported pump protocols.

At this control over pumps can be done in parallel from control systems connected through pump port and
PC port, PTS-1 controller internally tracks which control system locks control over dispensers:

www.technotrade.ua page 21 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CONVERSION BETWEEN ATG CONSOLES PROTOCOLS

In case if POS system already knows some open communication protocols of ATG consoles then it can use
PTS-1 controller for its conversion to any other ATG console or probe protocols without any additional
integration.

Communication of PTS-1 controller with control system (POS system, cash register, OPT terminal, etc) for
getting measurement data from probes can be done using popular open ATG console protocols. At this
connection is made through one of the probe ports, which has RS-232 interface (3 wires: TxD, RxD, Gnd) or
RS-485 interface (2 wires: A, B). Any of the probe ports can be configured to work as input port for
communication with control system.

Scheme of connections:

In this case the control system should know communication protocol of ATG console. PTS-1 controller in
this case serves as a protocol’s converter: converts input ATG console protocol into any other supported
ATG consoles and probe protocols.

www.technotrade.ua page 22 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

MONITORING OVER FUEL DISPENSERS AND TANKS

In case if there is an existing POS system already installed on the station PTS-1 controller allows to monitor
operation of the fuel dispensers and tanks (and optionally to make sales when required). At this PTS-1
controller is connected between existing POS system and fuel dispensers and ATG console (tank probes),
PTS-1 controller communicates with fuel dispensers and ATG console (probes) using their proprietary
communication protocols and with POS system – using open communication protocols for pumps and ATG
console. Monitoring system can connect to PC port of PTS-1 controller and get all data of fuel dispensers
sales and tanks real time, at this it can also provide control over the dispensers when required.

Scheme of connections:

www.technotrade.ua page 23 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

FUEL DISPENSERS SALES DATA FOR ATG CONSOLES FOR RECONCILIATION

PTS-1 controller can be applied for listening of communication exchange between POS system and
dispensers and sending of dispensers’ transactions to the ATG console for provision of tanks’ reconciliation
and automatic calibration. Installation of the PTS-1 controller between POS system and dispensers solves
this problem without any additional integration from the side of POS system.

Additionally, it is possible to apply PTS-1 controller inside the casing of the ATG console. At this a scheme of
connection specified on the above image is saved, but at some extra development of the console GUI it is
possible to make a completely new function of the console – provision of monitoring and control over
dispensers from the console in parallel with POS system. As a result, the console becomes a common
system of control, monitoring and account providing:

- connection of console to any POS system, OPT terminal for provision of control over dispensers
- possibility to connect various brands of probes, which communication protocols are not supported by
the console
- transmission from PTS-1 controller to console data on sales transaction of dispensers for formation of
reconciliation reports and automatic tanks calibration
- additional possibility to monitor and control fuel dispenser operation from the console display in
parallel to POS system already installed at petrol station (needs update of console software)

Scheme of connections:

www.technotrade.ua page 24 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 CONTROLLER MULTI POS SYSTEMS OPERATION


PTS-1 controller allows a possibility to lead management over the same fuel dispensers from several POS
systems and share ATG probes measurement values between several interconnected PTS-1 controllers.
Thus every interconnected PTS-1 controller is able to provide control over any of the connected fuel
dispensers and know ATG system measurement data of every other interconnected PTS-1 controller.

NOTE! In order to enable PTS-1 controller interconnection interface of DISP port should be configured to
RS-485 in configuration parameters of PTS-1 controller and DISP port should not be configured for any ATG
system (see section “PTS-1 controller configuration”).

Configuration:
At necessity to organize several working places at petrol station (several POS systems) each of the POS
systems should have its own PTS-1 controller connected. PTS-1 controllers should be interconnected with
each other through a dispatcher PTS port (DISP port on RS-485 interface) and also connected with fuel
dispensers. Thus control over each fuel dispenser at petrol station can be made from every POS system and
each PTS-1 controller will know measurement data of every ATG probe connected to any of the
interconnected PTS-1 controllers. At authorization of a fuel dispenser from one POS system the fuel
dispenser becomes locked by PTS-1 controller of this POS system and while it is locked all other POS
systems can not control over given fuel dispenser, they can only monitor current state of the fuel dispenser.
When operation of given POS system is finished with given fuel dispenser, PTS-1 controller of this POS
system unlocks the fuel dispenser and it becomes commonly available for all other PTS-1 controllers, which
makes it possible to be controlled (locked) by any of the PTS-1 controllers connected to other POS systems.

NOTE! In order to provide control over same fuel dispensers from several PTS-1 controllers locking and
unlocking of dispensers is required. For this reason in configuration of PTS-1 controller in parameters for
PTS-1 controller “Lock” and “Unlock” commands should be set to be used (see section “Configuration of
parameters for PTS-1 controller”).

NOTE! In order to provide correct exchange of ATG systems measurement data between interconnected
PTS-1 controllers logical addresses of connected ATG probes in configuration of interconnected PTS-1
controllers should not intersect (have various values in different PTS-1 controllers).

www.technotrade.ua page 25 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 CONTROLLER CONFIGURATION AND TESTING UTILITY


General information
PTS-1 controller configuration and testing utility Pts_config.exe serves for configuration and testing of the
PTS-1 controller. This utility is open source, which allows developers to use its source code in their
development. Currently utility is developed under Visual Studio using C# and Visual Basic .NET languages
under Windows OS. Development of the utility is also done in other programming languages under other
operating systems. For direct communication with PTS-1 controller the utility uses UniPump communication
protocol (own proprietary protocol of Technotrade LLC) – see document “UniPump communication protocol
specification for PTS-1 controller over fuel dispensers and ATG systems” for more information.

PTS-1 controller configuration and testing utility Pts_config.exe is a multipurpose utility for PTS-1 controller.
It provides the following possibilities:
- provision of control over the connected pumps and probes
- configuration of pumps (fuel dispensers) ports and probes (ATG systems) ports
- configuration of PTS-1 controller parameters
- update of the PTS-1 controller firmware
- logging of PTS-1 controller communication exchange with connected equipment
- self-diagnostics of PTS-1 controller communication ports and switches

www.technotrade.ua page 26 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Scheme of connections

NOTE! On some computers for correct operation COM-port FIFO settings should be adjusted to Tx: 1, Rx: 1.
This may also apply to situations when a computer does not have a native COM-port and external COM-
port converter are applied (like USB-to-COM, PCI-to-COM, Ethernet-to-COM, Bluetooth-to-COM etc).

Starting PTS configuration utility


Run Pts_config.exe utility. Make sure that in main menu in tab “Connection” type of PTS-1 controller
connection “Direct connection to COM-port” is selected (other types of connection serve for connection of
PTS-1 controller through fiscal modules). Set up a correct COM-port number and press “Connect” button.

www.technotrade.ua page 27 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “General”

Tab “General” serves for 3 main purposes:


- reading of PTS-1 controller firmware version information: firmware date and a list of supported
communication protocols of pumps and ATG systems (probes)
- saving of all PTS-1 controller configuration to a file on computer and restoring of all PTS-1 controller
configuration from a file on computer
- resetting of PTS-1 controller configuration

NOTE! Pay attention that the PTS-1 controller is using latest version of the firmware. Latest version of
firmware can be received upon request from Technotrade LLC company or downloaded from Technotrade
LLC company website. Normally new firmware for PTS-1 controller is issued together with PTS configuration
utility update having latest features of PTS-1 controller, so updated version of the PTS-1 controller
configuration utility Pts_config.exe should be also requested and downloaded. Information on how to
update PTS-1 controller firmware please find below in section “Tab ‘Firmware update’”.
In case if firmware version used in PTS-1 controller is older than required for Pts_config.exe utility – then a
warning message about it will appear in Events review field.
A list of all supported communication protocols and baud rates by PTS-1 controller as well as description
and settings of all parameters are described in file pts_config_en.xml (file may have other name depending
on the used language).
www.technotrade.ua page 28 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Pumps configuration”

Tab “Pumps configuration” is used for reading and writing of configuration of pump ports in PTS-1
controller.

Configuration of pump ports includes setting of communication protocol and baud rate for each of the
pump ports and also assigning of pumps to each of the pump ports. Each of the pumps can be assigned to
any of the pump ports and requires specification of the pump physical address.

Logical address of the pump means the address on which the control system (POS system, cash register,
OPT, etc) will see given fueling place. Physical address of the pump means address of the real fueling place,
which is programmed or set in configuration of the fuel dispenser fueling place.

For some pump protocols it is also necessary to configure parameters, which is to be done on tab
“Parameters” of the utility. Button “Param.” is used to transfer to “Parameters” tab to configure
parameters for the selected pump. Button “Configure pump parameters now” is used to transfer to
“Parameters” tab to configure parameters for all pumps.
After configuration is finished it is necessary to click a button “Set pumps configuration”, which will write
current pump ports configuration to controller. Information about result of operation of writing of
configuration to controller (whether it is made successfully or there was some problem) will be written in
the events review field on the form.
www.technotrade.ua page 29 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Probes configuration”

Tab “Probes configuration” is used for reading and writing of configuration of probe ports in PTS-1
controller.

Configuration of probe ports includes setting of communication protocol and baud rate for each of the
probe ports and also assigning of probes to each of the probe ports. Each of the probes can be assigned to
any of the probe ports and requires specification of the probe physical address.

Logical address of the probe means the address on which the control system (POS system, cash register,
OPT, etc) will see given probe. Physical address of the probe means address of the ATG system probe,
which is programmed or set in configuration of the ATG system console or probe.

For some probe protocols it is also necessary to configure parameters, which is to be done on tab
“Parameters” of the utility. Button “Param.” is used to transfer to “Parameters” tab to configure
parameters for the selected probe. Button “Configure pump parameters now” is used to transfer to
“Parameters” tab to configure parameters for all probes.
After configuration is finished it is necessary to click a button “Set probes configuration”, which will write
current probe ports configuration to controller. Information about result of operation of writing of
configuration to controller (whether it is made successfully or there was some problem) will be written in
the events review field on the form.
www.technotrade.ua page 30 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Parameters”

Tab “Parameters” serves for:


- configuration of parameters for PTS-1 controller
- configuration of parameters for pumps protocols
- configuration of parameters for probes protocols

All parameters are listed in a table with detailed description. Default parameters values are specified in a
separate column. To get a current value of the parameter it is necessary to read them from PTS-1
controller.

Configuration of PTS-1 controller parameters includes various adjustments for PTS-1 controller operation.

Some of the pumps and probes communication protocols also require setting of parameters. These
parameters are set for the specified logical address of the pump (or probe) and do not refer to other pumps
(or probes) in the PTS-1 controller.

Description and settings of all parameters as well as a list of all supported communication protocols and
baud rates by PTS-1 controller are described in file pts_config_en.xml (file may have other name depending
on the used language).

www.technotrade.ua page 31 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Examples of the device protocol parameters:

Parameters for pump - Dart communication protocol parameters for pump 1

Parameters for probe – Gilbarco Veeder Root communication protocol parameters for probe 1
www.technotrade.ua page 32 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Control”

Tab “Control” serves for provision of control over connected pumps and probes.

Section “Pumps” is used for displaying state of all 16 pumps of PTS-1 controller, current taken up nozzle,
state whether the pump is locked by PTS-1 controller, currently executed command and also volume,
money amount and price of dispensed fuel. Selection of the pump is made by selecting a pumps row in a
table.

Section “Pump order” is made for provision of control over the pumps:
- selection of pump
- field for setting a dose to be dispensed by selected pump
- selection of operation mode: volume preset, money amount preset, full tank
- commands to be given to selected pump: authorize, stop, suspend, resume, get total counters, get and
set price, get tag ID, turn lights on or off.
- fields for getting/setting prices of each nozzle of the selected pump

Section “Probes” is used for displaying measurement data of each of 16 probes of PTS-1 controller.

www.technotrade.ua page 33 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Section “Settings” includes the following settings:


- “Use extended commands” sets if communication with PTS-1 controller should be done using general
commands of extended (extended commands are to be used instead of general commands when there
is necessity to get/set values to PTS-1 controller, which size is bigger than provided by general
UniPump protocol format)
- “Use Lock/Unlock commands” – if this option is selected then PTS-1 controller will try to lock the pump
before giving command to it and unlock it after the command is performed, it this option is not set
then PTS-1 controller will not send LockRequest and UnlockRequest commands. This option should be
equal to PTS parameter “Use command LockRequest and UnlockRequest”.
- “Automatically authorize pump in full tank mode at nozzle up” – if this option is set then PTS-1
controller will automatically authorize the pump with volume on 999999 liters automatically at once
when the nozzle is up. This is made to set dispensing in completely automatic mode without any
actions to be performed on computer to start dispensing.
- “Automatically request total counters in end of dispensing” – this option is set then PTS-1 controller
will automatically request total counters from the pump at the end of dispensing (after a transaction is
closed).
- “Quantity of decimal digits”: these options set number of decimal places used in pump in fields of
volume, money amount, price, volume and money amount total counters. The quantity of decimal
digits in these fields should correspond to their quantity in the pump in order to make numbers
displays in pump same as in this PTS configuration utility.

Events review fields displays results of all performed operations.

www.technotrade.ua page 34 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Logging”

Tab “Logging” serves for logging of communication exchange between the PTS-1 controller and connected
pumps or probes.

With a reason to quickly locate and remove possible bugs in PTS-1 controller communication with
connected equipment (fuel dispensers and ATG systems) PTS-1 controller has a possibility of logging of its
exchange with connected equipment. Use Pts_config.exe utility to save in a control system exchange logs of
PTS-1 controller with connected equipment.

Configuration of PTS-1 controller to get a log


In order to get the log it is necessary first to set a port to be logged. For this connect PTS-1 controller to
computer and run Pts_config utility.

In Pts_config utility go to tab “Parameters” and there set a parameter for PTS-1 controller named “Port to
log” for the PTS-1 controller port, from which a log should be taken (see below screenshot). Save this
configuration.

www.technotrade.ua page 35 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

www.technotrade.ua page 36 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Procedure to get a log


For taking a log it is necessary to connect the computer to PTS-1 controller port LOG as shown on the
scheme below. At this PTS-1 controller should be working with connected equipment and control system.
Log is taken online – all current actions on the selected port are written to the log-file (no log is stored
inside PTS).

On the tab “Logging” it is necessary to select a folder, where the log-file is to be stored and press “Start
log” button. Log process will be displayed in the “Log verification” section and size of the log-file capture
will be displayed on the form.

“Log verification” section displays log process by indicating the direction of currently taken log:
1. Control system transfers data to PTS
2. PTS transfers data to Control system
3. PTS transfers data to Slave device
4. Slave device transfers data to PTS

www.technotrade.ua page 37 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

In case if there is no data transferred – the “Log verification” section displays a message “Log is not taken,
please recheck log parameters in PTS-1 controller and connections!”. If you see this message – you need to
recheck all the configuration and connections to get a log.

Each of the boxes in “Log verification” section display a direction of messages sent in PTS-1 controller
communication.

NOTE! At taking a log make sure that the red boxes on the right side blink indicating exchange between the
PTS and Slave device. If they do not blink – it means that the log of exchange on selected port is not
written, at this you should recheck your logging port parameter in PTS-1 controller parameter or check
communication between the PTS-1 controller and connected device on the specified port.

Log is accumulated to a file, size of file should be growing during the logging process, if it does not grow –
then the log is not taken, you will probably see a message “Log is not taken, please recheck log parameters
in PTS-1 controller and connections!” in “Log verification” section as described above.

Log-file has a name with indication of the time of log taken, for example: log_2014_07_04_12_14_58.bin,
which means that the log was taken on 4th of July, 2014 at 12:14:58.

www.technotrade.ua page 38 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

In case if log process is switched on – a new log-file with a new name is created each 30 minutes (old log-
file is saved). This allows to avoid log-file overfilling when its size comes to critical to the operating system.
Thus, you can switch on logging and wait until any problem happens. When it happens and you
approximately know time of this problem – you can take appropriate (by name) log-file and send to
Technotrade LLC for analysis.

Log in accumulated in the encrypted form. After a log of exchange is taken it is required to pass a
received bin file to Technotrade LLC company for examining and elimination of possible problems, for
reasons of which it was taken.

www.technotrade.ua page 39 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Firmware update”

Tab “Firmware update” servers for updating of firmware of PTS-1 controller and other interface converters.

PTS-1 controller firmware is constantly being improved and new versions of firmware with new added
communication protocols and fixed bugs of the previous firmware versions are proposed to be applied.
New versions of PTS-1 controller's firmware are always available for downloading for customers.

For update of firmware update it is necessary to make one of 2 possible actions:

1. Set 4th DIP-switch SA1 in position ON:

4th DIP-switch SA1


set to position ON

www.technotrade.ua page 40 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

2. Set a PTS-1 controller parameter “ALLOW FIRMWARE UPDATE” to enable firmware update of PTS-1
controller:

Connection of the PTS-1 controller is done directly to COM-port of computer.

www.technotrade.ua page 41 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

On tab “Firmware update” it is necessary select the COM-port number of the computer, check that
connection is not opened (COM-port is closed) and select the firmware file before starting the firmware
update process.

Firmware update process will start upon clicking on button “Start update”. In case if the firmware is not
being updated – power off the PTS-1 controller, click to start firmware update and power on the PTS-1
controller. At this the firmware update process should start.

NOTE! In order to prevent PTS-1 controller firmware from accidental update it is strictly recommended to
keep 4th DIP-switch SA1 in OFF position and disable PTS-1 controller parameter “ALLOW FIRMWARE
UPDATE” in any moment of time except for firmware update needs.

NOTE! Pay attention that your PTS-1 controller is using latest version of the firmware. Latest version of
firmware can be received upon request from Technotrade LLC company or downloaded from Technotrade
LLC company website. Normally new firmware for PTS-1 controller is issued together with PTS configuration
utility update having latest features of PTS-1 controller, so updated version of the PTS-1 controller
configuration utility Pts_config.exe should be also requested and downloaded. Information on the present
firmware version of PTS-1 controller can be checked on tab “General” (mentioned above).

Due to a reason that some firmware versions may erase all configuration of the PTS-1 controller it
recommended to save all configuration of PTS-1 controller to file before making an update (see on tab
“General” section “Save current configuration to file”) and in case if after the update the PTS-1 controller

www.technotrade.ua page 42 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

configuration turns out to be erased – restore all the configuration from the previously saved file (see on
tab “General” section “Restore configuration from file”).
NOTE! In case if an error happened during the firmware update process and PTS-1 controller became
unresponsive please make the following procedure:
1. Power off the PTS-1 controller and wait until all the LEDs on the PTS-1 controller board stop blinking or
shining.
2. In PTS-1 controller board set DIP-4 switch to ON position.
3. Connect PTS-1 controller to computer with PTS configuration utility.
4. In PTS configuration utility select the firmware update file, COM-port number and click on “Start
update” button.
5. Power on the PTS-1 controller – at this firmware update process should start automatically.
6. After the firmware update process is completed set DIP-4 switch back to OFF position.

www.technotrade.ua page 43 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Diagnostics ”

Tab “Diagnostics” servers for self-diagnostics of PTS-1 controller ports and DIP-switches.

Scheme of connections of the PTS-1 controller should be the following:

Lines “RS-485 A” in of each pump port and DISP port (RS-485) should be interconnected with each other,
also lines “RS-485 B” in of each pump port and DISP port (RS-485) should be interconnected with each
other as shown on the picture.

In LOG, USER and DISP (RS-232) ports pin TxD should be shortened with pin RxD as shown on the picture.

www.technotrade.ua page 44 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Diagnostics of port with RS-485 interfaces

In section “Diagnostics of RS-485 interface channels” results of diagnostics will be shown by color of labels.
Green color means that correspondent channel is working correctly (OK), red color – correspondent
channel is working incorrectly (BAD). In case if the error counter increases its value – then the errors are
taking place.

For PTS-1 controller of version PTS-U5 area RTS channel 1 – 4 should not be taken into account cause is
used with previous versions of PTS-1 controller (PTS-U, PTS-U2, PTS-U3).

Diagnostics of port with RS-232 interfaces


In section “Diagnostics of RS-232 interface channels” results of diagnostics will be shown by color of labels.
Green color means that correspondent channel is working correctly (OK), red color – correspondent
channel is working incorrectly (BAD). In case if the error counter increases its value – then the errors are
taking place.

Diagnostics of DIP-switch SA1


In section “Diagnostics of DIP-switches” current position of switches in SA1 DIP-switch on PTS board is
displayed. If displayed position of switches correspond to real position of switches in DIP-switch SA1 on PTS
board after checking them in various positions – then DIP-switch SA1 is working correctly.

www.technotrade.ua page 45 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

BUILT-IN PUMPS SIMULATOR

PTS-1 controller firmware between its pump protocols has a protocol “37. PUMP SIMULATOR”, which
allows to simulate presence of connected pumps. Baud rate at this can be set to any possible.

It allows to make easy debugging of control over dispensers through PTS-1 controller without real fuel
dispensers connected.

Purpose of the pump simulator protocols is to help developers in debugging of the control system software
over PTS-1 controller at absence of real dispenser pumphead for connection or software simulators of fuel
dispenser.

When protocol “37. PUMP SIMULATOR” is selected – then it is possible to debug dispensing of the pumps
without any pumphead or simulator connected to PTS-1 controller. Using parameters for this pump
protocol it is possible to set the number of taken up nozzle for every pump and also set whether the
dispensing should be done immediately or in full process.

www.technotrade.ua page 46 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Pump simulators allow to:


− authorize a dispenser with preset volume or amount values
− simulate dispensing of fuel through this dispenser and stop it at necessity
− set prices to dispenser and get prices from dispenser
− read total counters values (both amount and volume) (total counters are lead on each of the
nozzles separately and are dropped to zero at restart of the PTS-1 controller)
− set pause during dispensing and release (continue) dispensing after pause

www.technotrade.ua page 47 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

BUILT-IN ATG PROBES SIMULATOR

PTS-1 controller firmware between its ATG probes protocols has a protocol “7. ATG SIMULATOR”, which
allows to simulate presence of connected ATG probe. Baud rate at this can be set to any possible.

At this depending on the selected address of the ATG probe output measurement values will be the
following.

www.technotrade.ua page 48 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

For ATG probes with logical address 1 – dynamically changing all measurement parameters looping in the
following sequence (measurement numbers coming from 1 to 9 and back from 9 to 1):

Measurement number
1 2 3 4 5 6 7 8
Product level, mm 100 120 150 160 200 222.5 250 300
Measurement parameter

Water level, mm 1 1.2 1.5 1.6 2 2.2 2.5 3


Product volume, l 8000 9600 12000 12800 16000 17800 20000 24000
Water volume, l 80 96 120 128 160 176 200 240
Temperature, deg. C +11.0 +11.1 +11.3 +11.6 +12.0 +12.5 +13.1 +14.0
Product temperature
6400 7680 9600 10240 12800 14240 16000 19200
compensated volume, l
Product ullage, l 17000 15400 13000 12200 9000 7200 5000 1000
Product density, kg/m3 759 758.8 758.5 758.4 758 757.8 757.5 757
Product mass, kg 6072 6829.2 9102 9100.8 12128 12882.6 15150 18168

For ATG probes with logical addresses 2-16 there are statically fixed measurement values:
− product level – logical address + 123.4 mm (example - for address 6: 6123.4 mm)
− water level – logical address + 56.7 mm (example - for address 9: 956.7 mm)
− temperature – logical address + 0.8 deg. C (example - for address 12: 12.8 deg. C)

There are parameters for “7. ATG SIMULATOR” probes protocol allowing to simulate reception of automatic
in-tank deliveries reports from ATG systems.

www.technotrade.ua page 49 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 CONTROLLER API (APPLICATION PROGRAMMING INTERFACES)

PTS-1 controller for developers is supplied together with rich set of API (application programming
interfaces) for mostly used programming languages and operation platforms:
− C and C++: API for communication with a PTS-1 controller through a COM-port, documentation and
examples of application in source codes under Windows OS and Linux operation systems
− C#:
o open source library, which includes classes, methods and properties for communication
with PTS-1 controller for provision of control over dispensers and ATG systems and
configuration of PTS-1 controller
o open-source utility for testing and indication of all operations provided by the PTS-1
controller, allows to perform all operations with the PTS-1 controller
o open source fully-functional application for provision of control over up to 8 pumps and 4
ATG systems by the PTS-1 controller, allows to perform all operations with the PTS-1
controller
o open source PTS-1 controller configuration and testing utility
− Delphi: API for communication with a PTS-1 controller through a COM-port, documentation and
examples of application in source codes
− Java:
o open source library, which includes classes, methods and properties for communication
with PTS-1 controller for provision of control over dispensers and ATG systems and
configuration of PTS-1 controller
o open-source utility for testing and indication of all operations provided by the PTS-1
controller, allows to perform all operations with the PTS-1 controller
− Python: API for communication with a PTS-1 controller through a COM-port, documentation and
examples of application in source codes
− Visual Basic .NET:
o open source library, which includes classes, methods and properties for communication
with PTS-1 controller for provision of control over dispensers and ATG systems and
configuration of PTS-1 controller
o open-source utility for testing and indication of all operations provided by the PTS-1
controller, allows to perform all operations with the PTS-1 controller
o open source fully-functional application for provision of control over up to 8 pumps and 4
ATG systems by the PTS-1 controller, allows to perform all operations with the PTS-1
controller
o open source PTS-1 controller configuration and testing utility
− COM-object for PTS-1 controller:
o open-source COM-object (written in Microsoft Visual C++ 6.0 IDE in C++ programming
language) with methods and properties for communication with PTS-1 controller for
provision of control over dispensers and ATG systems and configuration of PTS-1 controller
o open-source application in Microsoft Visual Basic 6.0 for testing and indication of all
operations provided by the PTS-1 controller, allows to perform all operations with the PTS-
1 controller
− Description of communication protocol of PTS-1 controller: describes communication parameters,
messages structure, commands and responses of communication between POS management
system and PTS-1 controller, typical flowchart and diagram of interoperation

www.technotrade.ua page 50 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

C and C++ API


API represents a set of for communication with a PTS-1 controller through a COM-port, documentation and
examples of application in source codes under Windows OS and Linux operation systems

API can be compiled as a static or dynamic library. The library can be compiled by different compilers for
different operating systems: POSIX compatible (tested with GNU Linux only) and Microsoft Windows.

Source code of library are located in ./src directory.


Headers of library located in ./include directory.
Directory ./examples contains several examples of using library functions.
Directory ./doc contains html documentation generated by ccdoc programm.

Conditionally, API functions can be divided into groups:


− Manage API: Open/close, receiving error, set/get API options
o pts_open
o pts_open_dev
o pts_close
o pts_last_error
o pts_option_get
o pts_option_set
− Handle of a controller configuration
o pts_pump_config_get
o pts_atg_config_get
o pts_pump_config_set
o pts_atg_config_set
o pts_version_get
− Functions of a read and write parameters of the controller or filling places
o pts_param_get
o pts_param_set
− Functions of management by filling places
o pts_authorize
o pts_pts_authorize_by_amount
o pts_halt
o pts_lock
o pts_unlock
o pts_preset_prices
o pts_prices_request
o pts_status_request
o pts_total_request
o pts_trans_close
− Functions of reading measurements of Automatic Tank Gauge (ATG)
o pts_atg_measure_request

Library functions (except for : pts_open, pts_open_dev, pts_close) have common features:
− return value: functions return 0 (FM_OK) if no error and error code if error (see
include/pts_errors.h for
− determine the type of error)

www.technotrade.ua page 51 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

− first of parameter - pts_api_descriptor - integer obtained by the open function: pts_open or


pts_open_dev
− last parameter - pointer to PTS response structure - see include/pts_data.h for determine the data
type.

All commands in protocol involve getting a response.

PS: If you want use *.bat files for call make, please edit it for set true path to your favorite language
installation.

www.technotrade.ua page 52 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

C# PTS-1 controller configuration and testing utility


PTS-1 controller configuration and testing utility is written in C# programming language in Visual Studio
2010 Express and requires .NET Framework 2.0.

Given application includes 2 projects:

− PtsLib - project of PtsLib.dll library for operation with a PTS-1 controller. Includes classes, methods
and properties for communication with PTS-1 controller using requests and responses described in
UniPump communication protocol for communication with PTS-1 controller for provision of control
over dispensers and ATG systems and configuration of PTS-1 controller.
− Open source utility for configuration of PTS-1 controller, provision of control over pumps and
probes, logging of operation, firmware update, self-diagnostics, others (uses classes and methods
of PtsLib.dll library).

PTS-1 controller configuration and testing utility: tab “Control”

www.technotrade.ua page 53 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller configuration and testing utility: tab “Parameters”

PTS-1 controller configuration and testing utility: tab “Pumps configuration”


www.technotrade.ua page 54 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

C# application
The application for PTS-1 controller is written in C# programming language in Visual Studio 2010 Express
and requires .NET Framework 2.0.

Given application includes 2 projects:

− PtsLib - project of PtsLib.dll library for operation with a PTS-1 controller. Includes classes, methods
and properties for communication with PTS-1 controller using requests and responses described in
UniPump communication protocol for communication with PTS-1 controller for provision of control
over dispensers and ATG systems and configuration of PTS-1 controller.
− Fully-functional open source application for provision of control over up to 8 pumps and 4 ATG
systems by the PTS-1 controller, allows to perform all operations with the PTS-1 controller (uses
classes and methods of PtsLib.dll library).

General view of the application: allows to provide control over up to 8 pumps

www.technotrade.ua page 55 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form of ATG systems monitoring: allows to monitor up to 4 ATG systems

Form of PTS-1 controller configuration: allows to set configuration for pumps and ATG systems ports
and also set parameters

www.technotrade.ua page 56 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

C# API
The API for PTS-1 controller is written in C# programming language in Visual Studio 2010 Express and
requires .NET Framework 2.0.

Given API includes 2 projects:

− PtsLib - project of PtsLib_CSharp.dll library for operation with a PTS-1 controller. Includes classes,
methods and properties for communication with PTS-1 controller using requests and responses
described in UniPump communication protocol for communication with PTS-1 controller for
provision of control over dispensers and ATG systems and configuration of PTS-1 controller.
− Open-source utility for testing and indication of all operations provided by the PTS-1 controller,
allows to perform all operations with the PTS-1 controller (uses classes and methods of
PtsLib_CSharp.dll library).

Form for testing and indication of all operations provided by the PTS-1 controller

www.technotrade.ua page 57 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form for configuration of pumps ports of PTS-1 controller

Form for configuration of ATG systems ports of PTS-1 controller

www.technotrade.ua page 58 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Delphi API
Delphi API implements shared library libpts.dll calls.
Library libpts.dll was build with Borland compiler C PTS API (source C files you can find in libpts.zip).

Source code of library are located in ./src directory. Directory ./examples contains several examples of
using library functions.

Graphical form for testing API for PTS-1 controller written in Delphi

Conditionally, API functions can be divided into groups:


− Manage API: Open/close, receiving error, set/get API options
o pts_open
o pts_open_dev
o pts_close
o pts_last_error
o pts_option_get
o pts_option_set
− Handle of a controller configuration
o pts_pump_config_get
o pts_atg_config_get
o pts_pump_config_set
o pts_atg_config_set
o pts_version_get
− Functions of a read and write parameters of the controller or filling places
o pts_param_get
o pts_param_set
− Functions of management by filling places

www.technotrade.ua page 59 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

o pts_authorize
o pts_pts_authorize_by_amount
o pts_halt
o pts_lock
o pts_unlock
o pts_preset_prices
o pts_prices_request
o pts_status_request
o pts_total_request
o pts_trans_close
− Functions of reading measurements of Automatic Tank Gauge (ATG)
o pts_atg_measure_request

Library functions (except for : pts_open, pts_open_dev, pts_close) have common features:
− return value: functions return 0 (FM_OK) if no error and error code if error (see
include/pts_errors.h for
− determine the type of error)
− first of parameter - pts_api_descriptor - integer obtained by the open function: pts_open or
pts_open_dev
− last parameter - pointer to PTS response structure - see include/pts_data.h for determine the data
type.

All commands in protocol involve getting a response.

www.technotrade.ua page 60 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Java API

Java API for PTS-1 controller is written in Java programming language in NetBeans IDE 7.2.1.

Given API includes:


− JavaPtsLib: library for operation with a PTS-1 controller. Includes classes, methods and properties
for communication with PTS-1 controller using requests and responses described in UniPump
communication protocol for communication with PTS-1 controller for provision of control over
dispensers and ATG systems and configuration of PTS-1 controller.
− JavaPtsApp: open-source utility for testing and indication of all operations provided by the PTS-1
controller, allows to perform all operation with the PTS-1 controller (uses classes and methods of
JavaPtsLib).

Communication over the COM-port (RS-232 interface) is done using RXTX Java library (visit
www.rxtx.qbang.org for downloads and information): RXTX is a Java library, using a native implementation
(via JNI), providing serial and parallel communication for the Java Development Toolkit (JDK). It is based on
the specification for Sun's Java Communications API, though while many of the class descriptions are the
same the package used it not, since gnu.io is used instead. For more information please visit the rxtx wiki at
http://rxtx.qbang.org/wiki (latest releases of the library can be downloaded there).

Form for testing and indication of all operations provided by the PTS-1 controller

www.technotrade.ua page 61 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form for configuration of pumps ports of PTS-1 controller

Form for configuration of ATG systems ports of PTS-1 controller


www.technotrade.ua page 62 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Python API
Before installation of this package it is necessary to install PySerial (http://pyserial.sourceforge.net/).
To install PTS module, run python setip.py install, Where python = your desired python version executable.

Graphical form for testing API for PTS-1 controller written in Python

The protocol of exchange is realized in the pts.protocol module.


The exchange through a serial port is realized with use PySerial module (http://pyserial.sourceforge.net/)
(therefore, before installation of this package it is necessary to install PySerial).

The package was tested with python of versions 2.7 and 3.0

The pts.constants module contains values of various constants


The pts.config module - structures of data, for a controller configuration
The pts.response module - structures of the data returned by the controller
The pts.protocol module - protocol commands

Conditionally, API functions can be divided into groups:


− Manage API: Open/close, receiving error, set/get API options
o pts_open
o pts_open_dev

www.technotrade.ua page 63 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

o pts_close
o pts_last_error
o pts_option_get
o pts_option_set
− Handle of a controller configuration
o pts_pump_config_get
o pts_atg_config_get
o pts_pump_config_set
o pts_atg_config_set
o pts_version_get
− Functions of a read and write parameters of the controller or filling places
o pts_param_get
o pts_param_set
− Functions of management by filling places
o pts_authorize
o pts_pts_authorize_by_amount
o pts_halt
o pts_lock
o pts_unlock
o pts_preset_prices
o pts_prices_request
o pts_status_request
o pts_total_request
o pts_trans_close
− Functions of reading measurements of Automatic Tank Gauge (ATG)
o pts_atg_measure_request

Work with the protocol can be set for work without exceptions (when error occurred), and with generation
of exceptions (PtsException). Parameter of initialization of use_exceptions is responsible for it.

www.technotrade.ua page 64 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Visual Basic .NET PTS-1 controller configuration and testing utility


PTS-1 controller configuration and testing utility is written in VB.NET programming language in Visual
Studio 2010 Express and requires .NET Framework 2.0.

Given application includes 2 projects:

− PtsLib - project of PtsLib.dll library for operation with a PTS-1 controller. Includes classes, methods
and properties for communication with PTS-1 controller using requests and responses described in
UniPump communication protocol for communication with PTS-1 controller for provision of control
over dispensers and ATG systems and configuration of PTS-1 controller.
− Open source utility for configuration of PTS-1 controller, provision of control over pumps and
probes, logging of operation, firmware update, self-diagnostics, others (uses classes and methods
of PtsLib.dll library).

PTS-1 controller configuration and testing utility: tab “Control”

www.technotrade.ua page 65 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller configuration and testing utility: tab “Parameters”

PTS-1 controller configuration and testing utility: tab “Pumps configuration”


www.technotrade.ua page 66 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Visual Basic .NET application

The Visual Basic .NET application for PTS-1 controller is written in VB.NET programming language in Visual
Studio 2010 Express and requires .NET Framework 2.0.

Given application includes 2 projects:


− PtsLib: project of PtsLib.dll library for operation with a PTS-1 controller. Includes classes, methods
and properties for communication with PTS-1 controller using requests and responses described in
UniPump communication protocol for communication with PTS-1 controller for provision of control
over dispensers and ATG systems and configuration of PTS-1 controller.
− PTS: fully-functional open source application for provision of control over up to 8 pumps and 4 ATG
systems by the PTS-1 controller, allows to perform all operations with the PTS-1 controller (uses
classes and methods of PtsLib.dll library).

General view of the application: allows to provide control over up to 8 pumps

www.technotrade.ua page 67 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form of ATG systems monitoring: allows to monitor up to 4 ATG systems

Form of PTS-1 controller configuration: allows to set configuration for pumps and ATG systems ports
and also set parameters
www.technotrade.ua page 68 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Visual Basic .NET API


Visual Basic .NET API for PTS-1 controller is written in VB.NET programming language in Visual Studio 2010
Express and requires .NET Framework 2.0.

Given API includes 2 projects:


− PtsLib - project of PtsLib_VBNET.dll library for operation with a PTS-1 controller. Includes classes,
methods and properties for communication with PTS-1 controller using requests and responses
described in UniPump communication protocol for communication with PTS-1 controller for
provision of control over dispensers and ATG systems and configuration of PTS-1 controller.
− PTS - open-source utility for testing and indication of all operations provided by the PTS-1
controller, allows to perform all operations with the PTS-1 controller (uses classes and methods of
PtsLib_VBNET.dll library).

Form for testing and indication of all operations provided by the PTS-1 controller

www.technotrade.ua page 69 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form for configuration of pumps ports of PTS-1 controller

Form for configuration of ATG systems ports of PTS-1 controller

www.technotrade.ua page 70 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller COM-object for MS Windows OS


COM-object for PTS-1 controller is written in Microsoft Visual C++ 6.0 IDE in C++ programming language.
Project is located in PTSDriver folder. It builds PTSDriver.dll on output.
For communication with a PTS-1 controller it uses API (application programming interface), written in C
language (located in C_API folder).
In order to provide control over PTS-1 controller and simplify work of developers, who are working in
Windows OS in implementation of UniPump communication protocol of PTS-1 controller, a COM-object
with methods and properties for operation with PTS-1 controller is provided.

COM-object is compiled on Visual C++ 6.0 and is supplied together with a test application, written on Visual
Basic 6.0.
Documentation of COM-object describes all methods and properties of the COM-object and its application.

To register PTSDriver.dll library in Windows OS perform command

REGSVR32 PTSDriver.dll

from folder
PTS_SDK\API TOOLS\COM_object_API_plus_VB6.0_appilcation.rar\PTSDriver\ReleaseMinDependency\

www.technotrade.ua page 71 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Visual Basic 6.0 application


For testing of the COM-object an open-source application in Microsoft Visual Basic 6.0 is written (located in
VB_6.0_app folder). It provides GUI form for testing and indication of all operations provided by the PTS-1
controller, allows to perform all operation with the PTS-1 controller (uses classes and methods of
PTSDriver).

Form for testing and indication of all operations provided by the PTS-1 controller

www.technotrade.ua page 72 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form for configuration of pumps ports of PTS-1 controller

www.technotrade.ua page 73 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Form for configuration of ATG systems ports of PTS-1 controller

www.technotrade.ua page 74 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller UniPump communication protocol

PTS-1 controller is intended to be used in connection with control systems for petrol stations (POS systems,
cash registers, OPT terminals, etc) to provide simultaneous control over various types of electronic fuel
delivery dispensers and ATG systems of various manufactures using the single common communication
protocol UniPump. PTS-1 controller provides conversion of the common communication protocol UniPump
into various proprietary communication protocols of manufacturers.

UniPump communication protocol covers a list of commands and responses for communication with PTS-1
controller for provision of control over dispensers and ATG systems and configuration of PTS-1 controller.

www.technotrade.ua page 75 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 CONTROLLER SOFTWARE DEVELOPMENT KIT (SDK)


PTS-1 controller SDK appointment

PTS-1 controller SDK (Software Development Kit) is intended for developers of POS management software
for petrol stations that needs to provide control fuel dispensers and ATG systems.

PTS-1 controller SDK includes a PTS-1 controller and USB/RS-232 and USB/RS485 interface converters,
which allow to run software simulators of fuel dispensers and ATG systems on personal computer and
debug operation of control systems software with PTS-1 controller on it without a necessity to connect to
real fuel dispensers and ATG systems. Thus, it is convenient to work in office or at home rather than on a
working petrol station being connected to real equipment.

PTS-1 controller SDK allows developers to:


1. Study operation with the PTS-1 controller.
2. Implement the PTS-1 controller into own developed POS system or software application for control
over fuel dispensers and ATG level measurement systems for petrol stations.
3. Debug own software application to correctly provide control over fuel dispensers locally using
software simulators on the workplace without a necessity to go to the petrol station and connect to
real fuel dispensers.

www.technotrade.ua page 76 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller SDK structure


HARDWARE:
1. PTS-1 controller over fuel dispensers and ATG systems for petrol stations: 1 pcs
2. Interface converter RS-232/USB with cable: 2 pcs
3. Interface converter RS-485/USB with cable: 1 pcs
4. Cabling

SOFTWARE:
1. Software simulator of fuel dispensers
2. Software simulator of ATG systems (probes
3. API for developers in various programming languages
4. Useful utilities and applications for debugging of communication with PTS-1 controller

Note: the RS-232/USB and RS-485/USB interface converters are based on FTDI chips, it is possible to
download their drivers from the following page: https://ftdichip.com/drivers/vcp-drivers/.

PTS-1 controller SDK technical features


Specification
## PARAMETER VALUE
1 Voltage 12 V DC
2 Current consumption 550 mA max
3 Temperature range -40°C ÷ +80°C
4 Weight 600 g
5 Overall dimensions 160 x 160 x 85 mm

www.technotrade.ua page 77 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller SDK connections scheme

PTS-1 controller SDK box includes the PTS-1 controller board mounted inside of the metal case, USB/RS-232
and USB/RS-485 interface converters and cablings with for communication.

Control systems software, which uses UniPump communication protocol, connects to the PTS-1 controller
PC port.

USB/RS-232 and USB/RS-485 interface converters are used in order to convert signals coming from PTS-1
controller pumps and probes ports to USB ports in computer in order to run the pumps and probes
software simulators.

Thus, it is possible to debug a correct operation of software, being developed, with the PTS-1 controller
without a necessity to connect to real fuel dispensers and ATG systems, but using fuel dispenser’s software
simulators and ATG system’s software simulators.

www.technotrade.ua page 78 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

UniPump pumps software simulator


Purpose
PTS-1 controller SDK includes a pumps software simulator with a purpose to enable debugging of PTS-1
controller implementation in third party software. Purpose of software simulators is to debug operation of
control system software (cash register, POS system, OPT, etc) over fuel dispensers through PTS-1 controller
without a necessity to connect to real fuel dispensers.

Dispensed volume,
Main view money amount and price
total counters
Selection and Simulation of Pump mode of Volume and money Selection of nozzle to State of
opening/closing presence operation total counters take up/down and its pump
of a COM-port trigger state

Pump physical
address

Log of simulator operation with specification Pump mode of operation


of all transmitted commands and their data
operation Pumps software simulator main view

www.technotrade.ua page 79 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

In pumps simulator it is possible to add up to 99 pumps giving each a unique physical address. Each of the
pumps leads separately its total counters (volume and money amount) and prices for each of its 6 nozzles.
Total counter values as well as prices are stored in Windows system register. Each of the nozzles has a
trigger.

Each of the pumps can be transferred to automatic mode of operation (controlled from the control system)
or manual mode of operation (controlled manually and does not response to control system).

Pump control in pumps software simulator


In right-click mouse menu it is possible to preset the pump with money amount or volume value, stop the
pump, reset, pause and change volume:

Volume preset menu for pump


Pump right-button mouse menu

Configuration
Configuration of the pumps simulator includes configuration of:
− communication settings, which include setting of baud rate, number of data bits and stop bits,
parity control
− quantity of pumps (physical address is set on each pump control independently)
− technical characteristics of the pumps in simulator (flow rate, slow flow rate (when flowdown valve
is on), quantity of pulses before the flowdown valve is switched on
− protocol type: selection between standard UniPump communication protocol and extended
UniPump communication protocol for PTS-1 controller
− setting quantity of digits in values of volume, money amount, price and total counters
− selection of graphical skin
Pumps simulator can simulate presence at the pumps – take up nozzles and make dispensing in random
way thus making it possible to debug control system software as if it was operating on real petrol station.
Log window of the pumps simulator enables to see all the requests and responses in communication and
their respective data.
www.technotrade.ua page 80 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Settings of pumps simulator

For communication of PTS-1 controller with the UniPump pumps software simulator it is necessary to select
in PTS-1 controller configuration of the pump port communication protocol “2. UNIPUMP” and select
appropriate baud rate (equal to set in simulator (9600 baud rate by defaults) and set pumps physical
addresses equal to those, which are set for pumps in simulator. Also it is necessary to set parameters to
UniPump protocol for each of the pumps in PTS-1 controller configuration (see image below):
1. Parameter “Multiplier of dose” set equal to 1.
2. Parameter “Protocol type” set equal to “UniPump standard protocol” in case if protocol type is set to
“Standard UniPump” in pumps simulator or “Extended protocol for PTS-1 controller” in case if protocol
type is set to “Extended UniPump for PTS-1 controller” in pumps simulator.

Parameters for UniPump protocol in PTS-1 controller

www.technotrade.ua page 81 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

UniProbe ATG probes software simulator

Purpose
PTS-1 controller SDK includes a ATG probes software simulator with a purpose to enable debugging of PTS-
1 controller implementation in third party software. Purpose of software simulators is to debug operation
of control system software (cash register, POS system, OPT, etc) over ATG systems through PTS-1 controller
without a necessity to connect to real ATG systems or probes.

Main view
Selection and Simulation of ATG probe measurements
opening/closing presence (allows enable/disable any of the
Connection state
of a COM-port measured parameters)

Probe physical Tank height


address

Log of simulator operation with specification of


all transmitted commands and their data
operation ATG probes software simulator main view

In ATG probes simulator it is possible to set measurements of the following parameters:


− Products height
− Water height
− Temperature
− Product volume

www.technotrade.ua page 82 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

− Water volume
− Product ullage
− Product temperature compensated volume
− Product density
− Product mass

Any of the specified parameters can be switched on or off.


Also it is possible to set height of tank in the system.

Each of the ATG probes can be transferred to connected (responses to PTS-1 controller) or disconnected
(does not response to PTS-1 controller) state.

Probe control in ATG probes software simulator

Configuration
Configuration of the pumps simulator includes configuration of:
− communication settings, which include setting of baud rate, number of data bits and stop bits,
parity control
− quantity of ATG probes (physical address is set on each probe control independently)
− selection of graphical skin

Settings of probes simulator

www.technotrade.ua page 83 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Probes simulator can simulate presence of liquids in tanks – change height and volume of fuel, temperature
mass in random way thus making it possible to debug control system software as if it was operating on real
petrol station.
Log window of the probes simulator enables to see all the requests and responses in communication and
their respective data.
For communication of the PTS-1 controller with UniProbe ATG probes software simulator it is necessary to
select in PTS-1 controller configuration of the probe port communication protocol “9. UNIPROBE” and
select appropriate baud rate (equal to set in simulator (9600 baud rate by defaults) and set probes physical
addresses equal to those, which are set for probes in simulator.

www.technotrade.ua page 84 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Open source PTS-1 controller .NET application (C# and VB.NET)


Purpose
In order to provide control over PTS-1 controller and simplify work of developers, writing on Microsoft .NET
Framework in implementation of UniPump communication protocol of PTS-1 controller and give an open
source example of application for control over fuel dispensers and ATG systems at petrol station a .NET
library (with open source in C# and VB.NET languages and documentation on methods and properties) and
PTS-1 controller .NET application (with open source in C# and VB.NET languages) are provides.

Given application includes 2 projects:


− PtsLib - project of PtsLib.dll library for operation with a PTS-1 controller. Includes classes, methods
and properties for communication with PTS-1 controller using requests and responses described in
UniPump communication protocol for communication with PTS-1 controller for provision of control
over dispensers and ATG systems and configuration of PTS-1 controller.
− Fully-functional open source application for provision of control over up to 8 pumps and 4 ATG
systems by the PTS-1 controller, allows to perform all operations with the PTS-1 controller (uses
classes and methods of PtsLib.dll library).

PTS-1 controller .NET application is provided on both C# and VB.NET languages and requires .NET
Framework 2.0 for operation.

www.technotrade.ua page 85 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Start
To launch PTS-1 controller .NET application run PtsApplication.exe, select from a dropdown list a COM port
name, to which PTS-1 controller is connected, and press a button to open a selected COM port.

Note: connection with PTS-1 controller is made through a 3-wire realization of RS-232 interface, an
asynchronous half-duplex port, baud rate 57600 baud without a parity check. This configuration is hardly
coded inside a program.

Configuration of PTS-1 controller


To open configuration form go on the main form to menu item “Configuration” → “Fuel point configuration
settings”.

Configuration allows to set pump ports, probe ports, parameters in PTS-1 controller. It is quite convenient
to use and open source code helps to understand better how the PTS-1 controller works.

Pumps configuration tab allows to configure pumps ports of PTS-1 controller (like Pts_config.exe utility):

www.technotrade.ua page 86 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

ATGs configuration tab allows to configure probe ports of PTS-1 controller (like Pts_config.exe utility):

Parameters tab allows to read/write parameters in PTS-1 controller (like Pts_config.exe utility):

www.technotrade.ua page 87 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tab “Version information” allows to receive information about date and version of PTS-1 controller
firmware release and also a list of supported communication protocols of pumps and ATG systems (like
Pts_config.exe utility):

Main view

www.technotrade.ua page 88 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

In main view 8 fuel point icons are shown on the screen, which are to be linked to physical fuel points and
show its state.

Each of the displayed fuel point icons contains information about:


− Fuel point ID - a logical number of a fuel point in PTS-1 controller (number displayed in top left
corner, displaying with a symbol “-” means a fuel point not set)
− Status – status of a fuel point (displayed in a top line)
− Mode – selection between Preset mode (required to specify money amount or volume of fuel to be
dispensed) and Manual mode (does not require to specify money amount or volume of fuel to be
dispensed)
− Amount – money amount for which a fuel dispensing should be made (in a range 0,00 – 9999,99)
− Volume – fuel volume for which a fuel dispensing should be made (in a range 0,00 – 9999,99)
− Price – price per 1 liter/gallon of fuel
− Nozzle – number of an active nozzle that is taken up (displaying with a symbol “-” means no nozzle
is taken up)
Possible statuses of fuel points:
− OFFLINE – fuel point is not active, is not set or is controlled in a manual mode
− IDLE – fuel point is in idle state (all nozzles are hang down)
− NOZZLE – nozzle is taken up, waiting for allowance on fuel dispensing
− READY – fuel dispensing is allowed, test of indicator is running
− WORK – fuel dispensing is in process
− TransactionCompleted – transaction is finished normally, waiting for a nozzle to be hang down
− TransactionStopped b
− ERROR – Status of an error
Each of the fuel point icons contains the following buttons:
1. Start – start of fuel dispensing (fuel point authorization)
2. Stop – stop of fuel dispensing
3. Settings – opens a window for setting of fuel point icon configurations
4. Update prices – clicking leads to setting of prices per 1 liter/gallon of fuel for all nozzles of a fuel
point with which current fuel point icon is linked
5. Totals – opens a window for reading of fuel point totalizers

Settings of fuel point icons

www.technotrade.ua page 89 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Given window contains a dropdown list with all 4 pump ports of the PTS-1 controller, selecting each of
which leads to displaying of all fuel points’ IDs and corresponding fuel points’ addresses configured to given
pump port for a PTS-1 controller in a field below. Selecting one of the fuel point IDs and pressing OK button
leads to linking given fuel point icon to selected fuel point ID and displaying its status. Selecting of a PTS
pump port with value 0 will lead to switching off a fuel point icon.

Given window for each of the fuel points also contains a list of 6 nozzles for setting of prices per 1
liter/gallon of fuel, dispensed through these nozzles, in a range 0,00 – 999,99. If a fuel point has less than 6
nozzles – prices will be set only for first number of nozzles, which a fuel point has.

Clicking “Set prices” button leads to updating prices on selected fuel point. Clicking “Get prices” leads to
receiving of prices from selected fuel point.

Clicking OK button leads to updating a fuel point icon and updating (creating) a file “Config.xml” in root
folder with configuration of fuel point icons. At launching of a PTS-1 controller .NET application next time
configuration of fuel point icons will be read from this file “Config.xml” in root folder.

Reading of fuel point total counters

In the end of every dispensing application itself reads total counters from the pump on the nozzle, which
was dispensing. At this a sign of totals reading appears in the left top corner of the pump icon (and under
the header of the “T” command is displayed, which means that currently PTS-1 controller processes
TotalInfoRequest command).

Total counters can be updated at any moment from any of the pumps. Selecting of a button “Totals” on a
fuel point icon and clicking a button Update in it leads to reading of total counters:

www.technotrade.ua page 90 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Settings
Selection from top menu “Configuration” an item “Settings” leads to opening a new window, which allows
adjustment of

Settings include the following:


1. Authorization type of fuel dispensers:
− Authorization by fuel volume – dispensers are to be authorized with volume
− Authorization by money amount – dispensers are to be authorized with money amount
2. Authorization polling:
− Keep polling when pump is in READY state – after the Start button is clicked to authorize a
dispenser, but nozzle is not taken up on the dispenser, the fuel point displays READY state; this
option enables to keep constantly sending authorization command in READY state (until nozzle is
taken up of fuel point and it is authorized)
− Do not poll when pump is in READY state – after the Start button is clicked to authorize a
dispenser, but nozzle is not taken up on the dispenser, the fuel point displays READY state; this
option enables to send authorization command only once at clicking on a “Start” button of fuel
point icon
3. Extended commands:
− Use general commands – PTS-1 controller can work with general commands (for prices containing
up to 4 digits) and also with extended commands (for more quantity of digits in price values); this
option sets to use general commands in communication with PTS-1 controller (prices containing
with up to 4 digits)
− Use extended commands – PTS-1 controller can work with general commands (for prices
containing up to 4 digits) and also with extended commands (for prices containing with up to 9
digits); this option sets to use extended commands in communication with PTS-1 controller (prices
containing with up to 9 digits)
4. Request total counters:
− Request total counters – this option sets that application should automatically request total
counters after each dispensing on dispenser is performed
− Do not request total counters – this option sets that application should not automatically request
total counters after each dispensing on dispenser is performed

www.technotrade.ua page 91 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

5. Manual mode settings:


− Authorize automatically at nozzle up – this option sets that once a nozzle is taken up on the
dispenser – application should at once authorize it with a value set in field “Dose to authorize”; this
options enables the application to set in a way, when order is preset from dispenser keyboard and
application simply monitors the dispensers operation; in order this feature to work a fuel point
should be switched to Manual mode of operation (see above), in Preset mode this feature does not
work (preset is supposed to be given from application)
− Authorize manually at nozzle up – this option sets that dispensers are to be controlled fully from
the application by clicking on Start and Stop buttons both in preset and Manual modes of operation
6. Quantity of digits:
Setting of quantity of digits in money, volume, price and total counters (volume and money
amount) - this option is required in cases when dispensers may have non-standard quantity of
digits (for example 3 digits in volume and 0 digits in money amount)

Displaying ATG systems probes states

In ATG view 4 ATG icons are shown on the screen, which are to be linked to physical ATG systems (probes)
and show its state.
Each of the displayed ATG icons contains information about measured by ATG system (probe) parameters
of petroleum product inside tanks. Depending on the type (communication protocol) of ATG system (probe)
the following data may be displayed:
- Product level (accuracy 0.1 mm)
- Product volume (accuracy 1 liter)
- Product temperature compensated volume (accuracy 1 liter)
- Product ullage (volume) (accuracy 1 liter)
- Water level (accuracy 0.1 mm)
- Water volume (accuracy 1 liter)
- Temperature (accuracy 0.1 degree Celsius)
- Product density (accuracy 0.1 kg/m3)
- Product mass (accuracy 0.1 kg)

www.technotrade.ua page 92 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

If ATG system does not support any the parameters – a correspondent value label on ATG icon stays
disabled. Picture of a tank on the ATG icon shows visually level of product in tank compared to tank height
(which should be equal to ATG probe height). If ATG icon is linked with an ATG system – its state is
“ACTIVE”, else – “NOT ACTIVE”.

Settings of ATG probe icons

Given window contains a dropdown list with all 3


probe ports of the PTS-1 controller, selecting each
of which leads to displaying of all ATG probes’ IDs
and corresponding ATG probes’ addresses
configured to given probe port for a PTS-1 controller
in a field below. Selecting one of the ATG probe IDs
and pressing OK button leads to linking given ATG
probe icon to selected ATG probe ID and displaying
its state. Selecting of a PTS probe port with value 0
will lead to switching off a ATG probe icon.

Given window for each of the ATG probes also


contains a field for entering height of a tank with
installed probe (which is considered to be a
maximum level of product allowed for given tank).

www.technotrade.ua page 93 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

TiT.PTS classes help file


PTS-1 controller .NET application is based on a number of classes which documentation describing methods
and properties is supplied together with it. Documentation is generated in a form of html-files.

www.technotrade.ua page 94 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 controller test utilities


Purpose
PTS-1 controller test utilities are written in the following languages:
− C#
− VB 6.0
− VB.NET
− Java

It is written for developers in order to give open source test application, which shows how to communicate
with PTS-1 controller using commands from UniPump communication protocol without a necessity to
implement this protocol from zero.

Utility provides all operations with a PTS-1 controller. Thus developers using one of the above languages
can view how control over PTS-1 controller is provided in the utility and implement the same functions in
own developed applications for petrol stations.

Visual Basic 6.0 (uses COM-object) Java (developed in NetBeans IDE)

C# (developed in Visual Studio Express 2010) VB.NET (developed in Visual Studio Express 2010)

www.technotrade.ua page 95 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS terminal utility


Purpose
PTS terminal is used in order to provide debugging of PTS-1 controller operation. It allows to send to PTS-1
controller requests formed with bytes in accordance with UniPump communication protocol commands
without a necessity to add framing bytes and CRC.

This utility can be useful during development of own control software, when developers can test sending of
commands to PTS-1 controller and receive its responses using this utility and in such a way compare then
with responses processed in own developed control software.

Commands to be sent to the Selection of COM-port Selection of the logical address,


specified logical address and a button for open/close to which request is addressed

Log of communication (shows


commands and responses)

www.technotrade.ua page 96 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step-by-step configuration of the PTS-1 controller SDK

Purpose
This step-by-step instruction is provided in order to simplify understanding of PTS-1 controller SDK
operation and assembling. It describes basic steps to be made with PTS-1 controller SDK to assemble it
correctly and also to install and configure software coming in its structure.

Step 1. Downloading of PTS-1 controller SDK software


Using a link for download of PTS-1 controller SDK software it is necessary to get all files from it. The files
should include:
- API tools:
- Open source application programming interfaces, libraries, test utilities, applications and
documentation for development the third party software for communication with PTS-1
controller using various programming languages and environments
- UniPump communication protocol description for PTS-1 controller
- Software tools
- PTS-1 controller configuration tool Pts_config.exe
- latest stable PTS-1 controller firmware
- Software simulators
- SimUniPump - pumps software simulator
- SimUniProbe - probes software simulator
- Documentation
- User manuals
- Technical guides

Step 2. Assembling PTS-1 controller SDK cabling and connection to computer


For connection of PTS-1 controller SDK cabling it is necessary to have at least 2 USB-ports available in
computer (one USB-port – for control system, other USB-port – for fuel dispenser software simulator or
ATG probe software simulator). In case of absence of free USB-port it is possible to extend their number
using a USB hub.

PTS-1 controller SDK is generally supplied in a mounting box, in which the PTS-2 controller in located and
cables are connected with USB/RS-485 and USB/RS-232 interface converters. In order to start operation, it
is necessary to plug the USB output of the cables to USB ports of computer, after that power on the PTS-1
controller SDK.

www.technotrade.ua page 97 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Scheme of connections should be the following:

1. Connection of computer with PTS-1 controller: connect cable coming from PC port of PTS-1 controller to
USB-port of computer through USB/RS-232 interface converter (it will be seen as COM-port in the
computer).
2. Connection of pumps software simulator: connect cable coming from PUMP PORT 1 of PTS-1 controller
to USB port of computer through USB/RS-485 interface converter (it will be seen as COM-port in the
computer).
3. Connection of pumps software simulator: connect cable coming from USER PORT of PTS-1 controller to
USB port of computer through USB/RS-232 interface converter (it will be seen as COM-port in the
computer).
4. Switch on (power on) the PTS-1 controller SDK (requires 12 V DC power supply source).

It is worth to mention that only 1 application can work with a specific COM-port at the time, 2 applications
can not share the same COM-port.

Note: the RS-232/USB and RS-485/USB interface converters are based on FTDI chips, it is possible to
download their drivers from the following page: https://ftdichip.com/drivers/vcp-drivers/.

www.technotrade.ua page 98 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 3. Starting of the PTS-1 controller configuration utility Pts_config.exe


Run Pts_config.exe and from the main menu select connection type to be “Direct connection to PC COM-
port”, select COM-port with connected PTS-1 controller and click on the “Connect” button. Make sure that
the port is opened (red inscription “COM-port opened” should appear).

Click on button “Request firmware version” to get firmware information from PTS-1 controller.

www.technotrade.ua page 99 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 4. Configuration of pump ports


Go to tab “Pumps configuration” and set pumps ports configuration as shown on below screenshot. Set
protocol “2. UniPump” for pump port 1 and baud rate “4. 9600”. Assign this pump port to pumps 1 - 4, set
the physical addresses of these pumps also 1 – 4.

Click the button “Set pumps configuration” to save configuration in PTS-1 controller.

www.technotrade.ua page 100 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 5. Configuration of probes ports


Go to tab “Probes configuration” and set probes ports configuration as shown on below screenshot. Set
protocol “9. UniProbe” for probe port USER and baud rate “4. 9600”. Assign this probe port to probes 1 - 3,
set the physical addresses of these probes also 1 – 3.

Click the button “Set pumps configuration” to save configuration in PTS-1 controller.

www.technotrade.ua page 101 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 6. Configuration of PTS-1 controller parameters


Go to tab “Parameters” and select from a device list item “PTS”, click on a button “Write default
parameters”.

www.technotrade.ua page 102 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 7. Configuration of pumps parameters


On tab “Parameters” select from a device list item “Pump”, in a field “Number” select pump 1, in a protocol
list – “2. UniPump” (which means configuration of UniPump protocol parameters for pump 1).

Click on a button “Write default parameters” to write default values. Change the parameter with index 2
“Protocol type” to value “1. UniPump protocol for PTS” as it is shown on below screenshot.

Save current configuration for each of 4 pumps (select pumps one by one using field “Number”).

At this step configuration of the PTS-1 controller is finished.

www.technotrade.ua page 103 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 8. Configuration of pumps software simulator


Run SimUniPump.exe and go to configuration of its properties. Set properties as shown on screenshot:

After properties are set click OK and on the main form select a COM-port, to which pump port of is
connected, and click “Open” button:

After COM-port is opened in case if there is communication between the PTS-1 controller and pump
simulator – you should see blinking of red squares located in left top corner of pump icons in pump
simulator, and communication will be logged in log window of the simulator.

www.technotrade.ua page 104 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

At this in PTS-1 controller on pump port 1 green and red LEDs will begin to blink. Blinking of the green LED
means that PTS-1 controller is sending requests to the pump, blinking of the red LED means that the PTS-1
controller receives responses from the pump.
In case if only green LED is blinking on pump port 1 – there is a mistake in wiring connection or
configuration of the equipment (PTS-1 controller or pump).

www.technotrade.ua page 105 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 9. Configuration of ATG probes software simulator


Run SimUniProbe.exe and go to configuration of its properties. Set properties as shown on screenshot:

After properties are set click OK and on the main form select a COM-port, to which USER port of PTS-1
controller is connected, and click “Open” button.

After COM-port is opened in case if there is communication between the PTS-1 controller and ATG probes
simulator – you should see blinking of red squares located in left top corner of ATG probes icons in ATG
probes simulator, and communication will be logged in log window of the simulator.
At this in PTS-1 controller on USER port green and red LEDs will begin to blink once per second. Blinking of
the green LED means that PTS-1 controller is sending requests to the ATG, blinking of the red LED means
that the PTS-1 controller receives responses from the ATG.
In case if only green LED is blinking on USER port – there is a mistake in wiring connection or configuration
of the equipment (PTS-1 controller or ATG).

www.technotrade.ua page 106 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 10. Control over pumps and ATG probes in PTS-1 controller configuration and
testing utility
Go to tab “Control” in Pts_config.exe and click on the button “TURN ON”.

Now it is necessary to set initial values in the pump simulator and ATG probes simulator to display them in
the utility. Take up nozzles on the pumps and also set values for the ATGs (there is a possibility to emulate
presence in the simulators to make them work if there was really process going on). In the Pts_config.exe
utility you will see these changes.

www.technotrade.ua page 107 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Now you are able to provide full control over the pumps and read receive data from the ATG probes:

Pumps software simulator

Try to make different operations with pumps: set/get prices, take up/down nozzles, get total counters,
authorize a dispenser, others. Plays with decimal digits number to make them equal to used at your petrol
stations (Note! Number of decimal digits should be also changed in pumps software simulator).

ATG probes software simulator

Try to change the measured values of fuel in tanks and see how soon they are updated in Pts_config.exe
utility.

www.technotrade.ua page 108 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Step 11. Configuration of PTS-1 controller .NET application for control over pumps
and ATG probes
The open-source application written in C# and VB.NET is a good place to start development of new control
software for petrol stations. In this section we will see how it is easy to configure and run it.
Compile “PTS application” project or simply run PtsApplication.exe (application is located in PTS SDK
software kit and is located in API TOOLS folder for C# and VB.NET languages):

Go to main menu item “Configuration” → “Settings” and set configuration as shown below:

www.technotrade.ua page 109 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

In main form of the application for each of the fuel point icons go to setting (“Settings” button) and set a
correspondent fuel point number (from fuel point port 1) and prices for each of the nozzles:
− Fuel point icon #1 → FuelPoint ID = 1, Address = 1
− Fuel point icon #2 → FuelPoint ID = 2, Address = 2
− Fuel point icon #3 → FuelPoint ID = 3, Address = 3
− Fuel point icon #4 → FuelPoint ID = 4, Address = 4

Also here set prices for each of the nozzles:

Now the main form of the application allows to provide control over pumps in pump software simulator
(see configuration of the pumps simulator in step 7 above):

www.technotrade.ua page 110 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

To view the measurement by the ATGs in PTS application go to main menu item “ATG” → “ATG
measurement data”, where for each of the ATG icons in settings set configuration of ATG to get
measurement values and also set tank’s height:
www.technotrade.ua page 111 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Now PTS application is able to indicate current level measurement data from ATG system:

www.technotrade.ua page 112 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

www.technotrade.ua page 113 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Now the PTS application correctly works with pumps and ATGs software simulators.

www.technotrade.ua page 114 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

EXAMPLES OF FUEL DISPENSERS CONNECTION SCHEMES

Below sections show examples of connection to various brands of fuel dispensers. This information is
provided as an example. For reception of detailed information on connection to various brands of fuel
dispensers, configuration of the fuel dispensers and configuration of PTS-1 controller please refer to our
support mailbox [email protected].

As it is seen from below connection examples some brands of fuel dispensers have RS-485 interface on
board and thus are directly connected to PTS-1 controller, others do not have RS-485 interface and thus
require additional interface converter for connection to PTS-1 controller. In some cases, various models of
same brand of fuel dispensers have RS-485 interface, others – no. In such a way the best way to check how
your fuel dispenser is connected is to take its mainboard photos and send to us on our support mailbox
[email protected]. Mainboard is normally located inside the fuel dispenser pumphead behind
the displays.

www.technotrade.ua page 115 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Gilbarco dispenser connection scheme


Connection to Gilbarco dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “5. GILBARCO Two-Wire”, baud rate “3. 5787”.

Gilbarco dispenser ASSY


Gilbarco Encore 500 dispenser board M06104A001 rev. B board

- +

- +

www.technotrade.ua Gilbarco dispenser board Gilbarco Euroline dispenser


page 116 board
from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

+ -

+ -

Gilbarco Highline / Dimension Assy dispenser board Gilbarco Endeavor dispenser board

+ -

Gilbarco 3202 series dispenser board

+ -

- +

- +

Gilbarco Endeavor dispenser board

+ -
www.technotrade.ua page 117 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Gilbarco Frontier dispenser board - +

- + Gilbarco Encore dispenser board


Gilbarco Advantage China motherboard - +

www.technotrade.ua page 118 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Wayne Dresser dispenser connection scheme (RS-485 interface)


Connection to Wayne Dresser dispenser is made directly without any interface converter.

Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Wayne Dresser iGEM dispenser board

Line B
Line A

Wayne Dresser iGEM2 dispenser board

Line B
Line A

Line A
Line B

Wayne Dresser STMTAX Duplex dispenser


board

Wayne Dresser x2000/x2003 dispenser interface board

Line A

Line A Line B
Line B

Line A
Line B Line A

Line B

Wayne Dresser Global Vista CNG dispenser


interface board
Wayne Dresser V387 dispenser board
www.technotrade.ua page 119 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Wayne Dresser dispenser connection scheme (current loop interface)


Connection to Wayne Dresser dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “55. WAYNE USCL”, baud rate “4. 9600”.

- +
Wayne Dresser dispenser iGEM board Wayne Dresser V387 dispenser board

Wayne Dresser STMTAX Duplex dispenser


Wayne Dresser iGEM2 dispenser board
board
-
+

www.technotrade.ua page 120 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tatsuno (Japan) dispenser connection scheme


Connection to TATSUNO (Japan) dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “15. TATSUNO SS-LAN”, baud rate “5. 19200”.

Line A
Line B

TATSUNO POS joint box

www.technotrade.ua page 121 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tatsuno Europe (former Benc) dispenser connection scheme


Connection to TATSUNO Benc (Europe) dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “7. TATSUNO Benc PDE”, baud rate “5. 19200”.

Line A

Line B

TATSUNO Benc pumphead

www.technotrade.ua page 122 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tokheim dispenser connection scheme


Connection to Tokheim dispenser is made through 3-wire TH interface converter
(https://www.technotrade.ua/tokheim-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 3-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “6. TOKHEIM”, baud rate “4. 9600”.
DCC
TTC

TTD

DCC
TTC

TTD

Tokheim dispenser board

Tokheim dispenser board

www.technotrade.ua page 123 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

DCC

TTC
TTD
DCC

TTC
TTD

Tokheim dispenser interface board Tokheim dispenser interface board


DCC

TTC
TTD

Tokheim dispenser calculator with interface board


TTC

DCC
TTD

Tokheim dispenser interface board

www.technotrade.ua page 124 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tokheim Q320T dispenser calculator

www.technotrade.ua page 125 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tokheim dispenser connection scheme (RS-485 interface)


Connection to Tokheim dispenser through RS-485 interface is made directly without any interface
converter.

Configuration of PTS-1 controller pump port: protocol “6. TOKHEIM”, baud rate “4. 9600”.

Tokheim dispenser motherboard


Line A
Line B

www.technotrade.ua page 126 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Line B

Line A

Tokheim dispenser motherboard

www.technotrade.ua page 127 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tokheim India dispenser connection scheme


Connection to Tokheim India dispenser is made directly without any interface converter. Configuration of
PTS-1 controller pump port: protocol “59. Tokheim TQCL”, baud rate “4. 9600”.

Line A
Line B

www.technotrade.ua page 128 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Nuovo Pignone dispenser connection scheme (RS-485 interface)


Connection to Nuovo Pignone dispensers with RS-485 interface is made directly without any interface
converter. At this Nuovo Pignone dispenser should have an interface board for RS-485 interface and should
be adjusted to have Wayne Dart protocol.

Configuration of PTS-1 controller pump port: protocol “3. WAYNE Dart”, baud rate “4. 9600”.

Nuovo Pignone interface boards for RS-485 interface


for monoproduct and multiproducts dispensers
More info can be found on:
https://www.technotrade.ua/nuovo_pignone_interface_converter.html
Line A
Line B

Nuovo Pignone monoproduct dispenser board


Line A
Line B

Nuovo Pignone multiproduct dispenser board

www.technotrade.ua page 129 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Nuovo Pignone dispenser connection scheme (4-wire current loop interface)


Connection to Nuovo Pignone dispensers with 4-wire current loop interface is made through 4-wire NP
interface converter (https://www.technotrade.ua/nuovo_pignone_interface_converter.html), which
provides connection of RS-232/RS-485 interfaces to 4-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “24. NUOVO PIGNONE CL”, baud rate “1. 2400”.

Rx+
Tx+
Rx-
Tx-
Rx+
Tx+
Rx-
Tx-

Nuovo Pignone dispenser board

Nuovo Pignone dispenser board

www.technotrade.ua page 130 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Logitron dispenser connection scheme (3-wire current loop interface)


Connection to Logitron dispensers with 3-wire current loop interface is made through 3-wire LP interface
converter (https://www.technotrade.ua/logitron-interface-converter.html), which provides connection of
RS-232/RS-485 interfaces to 3-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “19. PUMALAN Marconi”, baud rate “1. 4800”.

TxD
Gnd
RxD

PUMA Logitron computer

www.technotrade.ua page 131 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Bennett dispenser connection scheme (RS-485 interface)


Connection to Bennett dispensers with RS-485 interface is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “22. BENNETT 485”, baud rate “2.4800”.

Line B
Line A

Bennett dispenser board

www.technotrade.ua page 132 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Bennett dispenser connection scheme (2-wire current loop interface)


Connection to Bennett dispensers with 2-wire current loop interface is made through 2-wire GB interface
converter (https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of
RS-232/RS-485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “21. BENNETT”, baud rate “2.4800”.

+
-

Bennett dispenser board

www.technotrade.ua page 133 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Batchen Email dispenser connection scheme


Connection to Batchen dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “18. BATCHEN Electroline” (for single-product
dispensers) or “39. BATCHEN MPP” (for multi-product dispensers), baud rate “2. 4800”.

+ -
-
+

Batchen dispenser board

Batchen dispenser board

www.technotrade.ua page 134 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Scheidt & Bachmann T20 dispenser connection scheme


Connection to Scheidt&Bachmann T20 dispenser is made through S&B T20 interface converter board.

Configuration of PTS-1 controller pump port: protocol “2. UniPump”, baud rate “4. 9600”.

DIP-switch for
address setting

Line A

Line B

Address setting on S&B T20 interface converter board using a DIP-switch


Address 1&2 3&4 5&6 7&8 9 & 10 11 & 12 13 & 14 15 & 16
DIP 1 OFF OFF OFF OFF ON ON ON ON
DIP 2 OFF OFF ON ON OFF OFF ON ON
DIP 3 OFF ON OFF ON OFF ON OFF ON
DIP 4 OFF OFF OFF OFF OFF OFF OFF OFF

www.technotrade.ua page 135 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Coptron dispenser connection scheme


Connection to Coptron pumphead is made directly without any interface converter. Configuration of PTS-1
controller pump port: “33. DART Simplex”, baud rate “4. 9600”.

Line A

Line A
Line B

Line B

Coptron pumphead

www.technotrade.ua page 136 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Midco dispenser connection scheme


Connection to Midco pumphead is made directly without any interface converter. Configuration of PTS-1
controller pump port: protocol “49. Midco”, baud rate “4. 9600”.

Midco pumphead

www.technotrade.ua page 137 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Petrotec dispenser connection scheme


Connection to Petrotec dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “5. Gilbarco Two-Wire”, baud rate “3. 5787”.

- +

Petrotec dispenser board

www.technotrade.ua page 138 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Galileo dispenser connection scheme


Connection to Galileo dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “10. GALILEO PumpControl”, baud rate “2. 4800”.

- +

+ -

Galileo dispenser board

www.technotrade.ua page 139 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Prowalco dispenser connection scheme


Connection to Prowalco dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “27. PROWALCO”, baud rate “2. 4800”.

Prowalco dispenser board

www.technotrade.ua page 140 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Emgaz Dragon / Fornovo LPG dispenser with EsiWelma pumphead


connection scheme
Connection to EsiWelma pumphead is made through 3-wire LP interface converter
(https://www.technotrade.ua/logitron-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 3-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “19. PUMALAN Marconi”, baud rate “2. 4800”.

RxD
TxD
Gnd

EsiWelma pumphead

www.technotrade.ua page 141 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Maser dispenser connection scheme


Connection to Maser dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “45. MASER GMS”, baud rate “4. 9600”.

Maser dispenser computer connections label


Line A
Line B

www.technotrade.ua page 142 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Petposan-S4 / Meksan-S4 / Europump-S4 / Yenen dispensers connection


scheme
Connection to S4 computer is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

- +

S4 computer

www.technotrade.ua page 143 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Yenen dispensers connection scheme


Connection to S4s computer is made either directly from the PTS-1 controller using RS-485 interface (no
additional interface converter is required) or through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

- +
Line A
Line B

S4s computer
www.technotrade.ua page 144 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Petposan-Beta / Europump-Beta dispensers connection scheme


Connection to Beta computer is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

IntBox

Petposan-Beta CPU

www.technotrade.ua page 145 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

EuroPump dispenser connection scheme


Connection to EuroPump dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

EuroPump EUROSTAR E2-SL dispenser computer EuroPump dispenser computer

+ -
www.technotrade.ua page 146 from 193
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Mekser dispenser connection scheme


Connection to Mekser dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

- +

Mekser dispenser board

www.technotrade.ua page 147 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Fuelsis dispenser connection scheme


Connection to Fuelsis dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Fuelsis dispenser pumphead computer


Line A
Line B

www.technotrade.ua page 148 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Mepsan Unimep dispenser connection scheme


Connection to Mepsan dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Line A

Line B
Mepsan Unimep dispenser calculator

Mepsan Unimep dispenser calculator


Line A

Line B

Line B
Line A

Line B

Line A

Mepsan dispenser board

www.technotrade.ua page 149 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Meksan / Wayne SU86 dispenser connection scheme


Connection to Meksan / Wayne SU86 dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Line A

Line B

MEKSAN / WAYNE SU86 dispenser board

www.technotrade.ua page 150 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Baransay dispenser connection scheme


Connection to Baransay dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Line A
Line B

Baransay dispenser board

www.technotrade.ua page 151 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

2A LPG dispenser connection scheme


Connection to 2A dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Line A
Line B

2A dispenser computer

www.technotrade.ua page 152 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Falcon dispenser connection scheme


Connection to Falcon dispenser is made through 2-wire GB interface converter
(https://www.technotrade.ua/gilbarco-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “43. FALCON LPG”, baud rate “3. 5787”.

+
-

+
-

Falcon dispenser computer E11

Falcon dispenser computer E22

www.technotrade.ua page 153 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Tiger dispenser connection scheme


Connection to Tiger dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “33. Dart Simplex”, baud rate “4. 9600”.

Line B

Line A

Tiger dispenser mainboard

www.technotrade.ua page 154 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Korea EnE (LG EnE) dispenser connection scheme


Connection to Korea EnE (LG EnE) dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “20. EnE Korea”, baud rate “4. 9600”.

Korea EnE / LG EnE dispenser board


Line A
Line B

www.technotrade.ua page 155 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Dong Hwa Prime dispenser connection scheme


Connection to Dong Hwa dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “31. DONG HWA Prime”, baud rate “4. 9600”.

Line A
Line B

Dong Hwa dispenser board

Line A
Line B

Dong Hwa dispenser board

www.technotrade.ua page 156 from 193


Dong Hwa dispenser board
PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Gallagher (PEC) dispenser connection scheme


Connection to PEC dispenser is made through 2-wire NZ interface converter
(https://technotrade.kiev.ua/compac-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “25. GALLAGHER (PEC)”, baud rate “6. 1200”.

+
-

Retron 80 dispenser board connection

www.technotrade.ua page 157 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Compac dispenser connection scheme


Connection to Compac dispenser is made through 2-wire NZ interface converter
(https://technotrade.kiev.ua/compac-interface-converter.html), which provides connection of RS-232/RS-
485 interfaces to 2-wire current loop interface.

Configuration of PTS-1 controller pump port: protocol “25. GALLAGHER (PEC)”, baud rate “6. 1200”.

Compac dispenser junction box

www.technotrade.ua page 158 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Safe dispenser connection scheme


Connection to SAFE dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “9. SAFE Graf”, baud rate “4. 9600”.

Line A
Line B

SAFE Graf electronic head PMII

www.technotrade.ua page 159 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

MS Gas dispenser connection scheme


Connection to MS GAS dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “53. KOREA CNG”, baud rate “4. 9600”.

Line B
Line A

MS GAS dispenser WLD-4 motherboard

www.technotrade.ua page 160 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Shibata dispenser connection scheme


Connection to SHIBATA dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “15. SS-LAN”, baud rate “5. 19200”.

Line B
Line A

SHIBATA dispenser motherboard

www.technotrade.ua page 161 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Aspro Develco dispenser connection scheme


Connection to Aspro Develco dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “8. DEVELCO”, baud rate “2. 4800”.

Line A
Line B

Develco dispenser motherboard

www.technotrade.ua page 162 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

HongYang dispenser connection scheme


Connection to HongYang dispenser is made through 4-wire HY interface converter
(https://www.technotrade.ua/hongyang-interface-converter.html), which provides connection of RS-
232/RS-485 interfaces to 4-wire current loop interface.
Configuration of PTS-1 controller pump port: protocol “42. HongYang” (in case of single-product dispenser)
or “42. HongYang MPD 886” (in case of multi-product dispenser), baud rate “1. 2400”.

Rx+
Tx+
Rx-

Rx+
Tx-

Tx+
Rx-
Tx-
Rx+
Tx+
Rx-
Tx-

HongYang
dispenser boards

Tx-
Rx-
Tx+
Rx+

www.technotrade.ua page 163 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

HongYang dispenser calculator

HongYang dispenser calculator

HongYang dispenser calculator

Rx- Tx+ Rx+ Tx-

www.technotrade.ua page 164 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Lanfeng dispenser connection scheme


Connection to Lanfeng dispenser can be made either directly using RS-485 interface.

Configuration of PTS-1 controller pump port: protocol “15. TATSUNO SS-LAN”, baud rate “5. 19200”.

Gnd
TxD
RxD
+5V

Line A

Line B

Lanfeng RS-232 dispenser board

Line A
Lanfeng RS-485 dispenser board

Line B

Lanfeng RS-485 dispenser board

www.technotrade.ua page 165 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Sanki dispenser connection scheme


Connection to Sanki dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “52. SANKI NG”, baud rate “4. 9600”.

Line A

Line B

Sanki dispenser board


Line A

Sanki dispenser board


Line B

www.technotrade.ua page 166 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Sanki dispenser board

Line A
Line B
Line A

Line B

Sanki dispenser board

www.technotrade.ua page 167 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Datian Machines dispenser connection scheme


Connection to Datian Machines dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “52. SANKI NG”, baud rate “4. 9600”.

Line A
Line B

Datian Machines dispenser interface board

www.technotrade.ua page 168 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Eaglestar dispenser connection scheme


Connection to Eaglestar dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “52. SANKI NG”, baud rate “4. 9600”.

Eaglestar dispenser mainboard


Line A

Line B

www.technotrade.ua page 169 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Blue Sky dispenser connection scheme


Connection to Blue Sky dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “26. Blue Sky”, baud rate “2. 4800”.

Line A
Line B

Line A

Blue Sky LT-B dispenser board Line B


Blue Sky LT-L/LT-LG dispenser board

Line A
Line B
Line A

Line B

Blue Sky LT-C/LT-H dispenser board

Blue Sky LT-B Pro dispenser board

www.technotrade.ua page 170 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Censtar dispenser connection scheme


Connection to Censtar dispenser can be made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “52. SANKI NG”, baud rate “4. 9600”.

Line A
Line B

Censtar 3100 model interface board

Line A
Line B

Censtar 6200 model interface board

www.technotrade.ua page 171 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Knipflow dispenser connection scheme


Connection to Knipflow dispenser can be made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “52. SANKI NG”, baud rate “4. 9600”.

Knipflow dispenser mainboard


Line A

Line B

www.technotrade.ua page 172 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Changlong dispenser connection scheme


Connection to Changlong dispenser can be made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “64. Changlong”, baud rate “4. 9600”.

Changlong dispenser
interface boardboard
Line A
Line B

www.technotrade.ua page 173 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Zcheng Genuine Machines dispenser connection scheme


Connection to Zcheng Genuine Machines dispenser can be made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “57. Zcheng Genuine Machines”, baud rate “4. 9600”
or “2. 4800”.

Line A

Line B

Zcheng Genuine dispenser interface boardboard

www.technotrade.ua page 174 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Bailong dispenser connection scheme


Connection to Bailong dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “52. SANKI NG”, baud rate “4. 9600”.

Line A
Line B

Bailong dispenser board

www.technotrade.ua page 175 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Topaz dispenser connection scheme


Connection to TOPAZ dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “41. TOPAZ”, baud rate “2. 4800”.

Line A
Line B

Topaz dispenser system board

www.technotrade.ua page 176 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Shelf dispenser connection scheme


Connection to SHELF dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “16. SHELF”, baud rate “4. 9600”.

Shelf dispenser system board


Line A

Line B

www.technotrade.ua page 177 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

UniCon dispenser connection scheme


Connection to UniCon dispenser is made directly without any interface converter.
Configuration of PTS-1 controller pump port: protocol “16. UniPump”, baud rate “4. 9600”.

Line A

Line B

UniCon dispenser system board

www.technotrade.ua page 178 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Mechanical dispensers connection scheme


Connection to mechanical dispensers or to dispensers, which communication protocol is not supported, can
be done through MC-4 controller over mechanical dispensers (https://www.technotrade.ua/mechanical-
controller.html), which provides direct control over operation of electronic and mechanical fuel dispensers
by controlling dispenser’s internal resources: motor, pulse sensor, nozzle, slowdown valve..

Configuration of PTS-1 controller pump port: protocol “2. UniPump”, baud rate “4. 9600”.

www.technotrade.ua page 179 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

EXAMPLES OF ATG SYSTEMS CONNECTION SCHEMES

Below sections show examples of connection to various brands of probes and ATG systems. This
information is provided as an example. For reception of detailed information on connection to various
brands of probes and ATG systems, configuration of the probes and ATG systems and configuration of PTS-
1 controller please refer to our support mailbox [email protected].

www.technotrade.ua page 180 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Gilbarco Veeder Root TLS consoles connection scheme


Connection to Gilbarco Veeder Root TLS system is made directly to one of probe ports of PTS-1 controller
(RS-232 interface).
Configuration of PTS-1 controller probe port: protocol “1. GILBARCO Veeder Root”, baud rate is selected to
be equal to set in TLS ATG system.

Gnd
TxD
RxD

RS-232 port

Gilbarco Veeder Root TLS ATG console

Start Italiana console connection scheme


Connection to Start Italiana console is made directly to one of probe ports of PTS-1 controller (RS-232
interface).
Configuration of PTS-1 controller probe port: protocol “1. GILBARCO Veeder Root”, baud rate is selected to
be equal to set in Start Italiana console.

Gnd
TxD
RxD

RS-232 port

Start Italiana ATG console

www.technotrade.ua page 181 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Start Italiana wired probes connection scheme


Connection to Start Italiana wired probes is made directly to DISP (RS-485) port of PTS-1 controller (RS-485
interface).
Configuration of PTS-1 controller probe port: protocol “2. START ITALIANA SMT-XMT”, baud rate “4. 9600”.

Line A
Line B

Start Italiana probe (RS-485)

Start Italiana wireless probes connection scheme


Connection to Start Italiana wireless probes is made through wireless receiver to one of probe ports of PTS-
1 controller (RS-232 interface or RS-485 interface).
Configuration of PTS-1 controller probe port: protocol “2. START ITALIANA SMT-XMT”, baud rate “4. 9600”.

Gnd
TxD
RxD

RS-232 port

Start Italiana wireless repeater

www.technotrade.ua page 182 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Alisonic wired probes connection scheme


Connection to Alisonic wired probes is made directly to DISP (RS-485) port of PTS-1 controller (RS-485
interface).
Configuration of PTS-1 controller probe port: protocol “22. Alisonic Delphi”, baud rate “4. 9600”.

Line A
Line B

Alisonic probe (RS-485)

Alisonic wireless probes connection scheme


Connection to Alisonic wireless probes is made through Alisonic wireless receiver to DISP (RS-485) port of
PTS-1 controller (RS-485 interface).
Configuration of PTS-1 controller probe port: protocol “22. Alisonic Delphi”, baud rate “4. 9600”.

Line A
Line B
Alisonic wireless receiver

www.technotrade.ua page 183 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Struna ATG system connection scheme


Connection to Struna system is made directly to one of probe ports of PTS-1 controller (RS-232 interface).
Configuration of PTS-1 controller probe port: protocol “4. STRUNA Kedr spec. 1.4”, baud rate is selected to
be equal to set in Struna ATG system.

Gnd
TxD
RxD

RS-232 port

Struna ATG calculation unit

OPW Site Sentinel ATG system connection scheme


Connection to OPW system is made directly to one of probe ports of PTS-1 controller (RS-232 interface).
Configuration of PTS-1 controller probe port: protocol “3. Petrovend4”, baud rate is selected to be equal to
set in OPW ATG system.

Gnd
TxD
RxD

RS-232 port

OPW ATG console

STRUNA ATG calculation unit

www.technotrade.ua page 184 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Colibri ATG system connection scheme


Connection to Colibri system is made directly to one of probe ports of PTS-1 controller (RS-232 interface).
Configuration of PTS-1 controller probe port: protocol “1. Gilbarco Veeder Root”, baud rate is selected to be
equal to set in Colibri ATG system.

Gnd
TxD
RxD

RS-232 port

Colibri ATG console

STRUNA ATG
calculation unit

Fafnir ATG system connection scheme


Connection to FAFNIR system is made directly to one of probe ports of PTS-1 controller (RS-232 interface).
Configuration of PTS-1 controller probe port: protocol “5. Fafnir Visy-Quick”, baud rate is selected to be
equal to set in FAFNIR ATG system.

Gnd
TxD
RxD

RS-232 port

FAFNIR-Command ATG console

STRUNA ATG calculation unit

www.technotrade.ua page 185 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Hectronic ATG probes connection scheme


Connection to Hectronic probes is made directly to one of probe ports of PTS-1 controller (RS-232
interface) to Hectronic OptiLevel Supply box.
Configuration of PTS-1 controller probe port: protocol “8. Hectronic HLS”, baud rate “4. 9600”.

Gnd
TxD
RxD

RS-232 port

Hectronic OptiLevel Supply box

STRUNA ATG calculation unit

Vega radar level meters


Connection to VEGA meters is made through a VEGAMET probes is made directly to one of probe ports of
PTS-1 controller (RS-232 interface) to Hectronic OptiLevel Supply box.
Configuration of PTS-1 controller probe port: protocol “10. Vega”, baud rate “4. 9600”.

Gnd
TxD
RxD

RS-232 port

VEGAMET signal
VEGAPULS
conditioning instrument
radar meter

www.technotrade.ua page 186 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Windbell magnetostrictive probes connection scheme


Connection to Windbell probes is made directly to DISP (RS-485) port of PTS-1 controller (RS-485 interface).
Configuration of PTS-1 controller probe port: protocol “11. Windbell”, baud rate “4. 9600”.

Line A
Line B

www.technotrade.ua page 187 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

North Falcon wired probes connection scheme


Connection to North Falcon wired probes is made directly to DISP (RS-485) port of PTS-1 controller (RS-485
interface).
Configuration of PTS-1 controller probe port: protocol “22. Alisonic Delphi”, baud rate “4. 9600”.

Line A
Line B

North Falcon probe (RS-485)

North Falcon wireless probes connection scheme


Connection to North Falcon wireless probes is made through North Falcon wireless receiver to DISP (RS-
485) port of PTS-1 controller (RS-485 interface).
Configuration of PTS-1 controller probe port: protocol “22. Alisonic Delphi”, baud rate “4. 9600”.

Line A
Line B
North Falcon wireless receiver

www.technotrade.ua page 188 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

PTS-1 CONTROLLER PCB BOARD


PCB board top view

PCB board bottom view

www.technotrade.ua page 189 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

Board dimensions

www.technotrade.ua page 190 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

RS-232 PORT CABLE CONNECTOR

Pinout of cable used for connection RS-232 ports of PTS-1 controller to computer:
DB-9F connector

STRUNA ATG
calculation unit
To PTS RS-232 port To COM-port of computer

STRUNA ATG STRUNA ATG calculation unit


calculation
To pin TxD unit Pin 2

To pin RxD Pin 3

To pin GND Pin 5

www.technotrade.ua page 191 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

CERTIFICATES

PTS-1 controller over fuel dispensers and ATG systems for petrol stations complies with the essential
requirements of the European Directive:
- Electromagnetic Compatibility (EMC) Directive 2004/108/EC

Conformity is assessed in accordance to the following standards:


1. Radio disturbance characteristics – EN 55022:2010 (IEC CISPR 22:2008), Class A
2. Immunity characteristics – EN 55024:2010 (IEC CISPR 24:2010)

We hereby declare that the apparatus named above has been designed to comply with the relevant
sections of the above referenced specifications. The unit complies with all applicable Essential
Requirements of the Directive.

The conducted tests are documented in the test reports No. 1047/1-5-2014 and 1047/2-5-2014 and are
maintained at the corporate headquarters of Technotrade LLC as an evidence of conformity.

www.technotrade.ua page 192 from 193


PTS-1 CONTROLLER OVER FUEL DISPENSERS AND ATG SYSTEMS FOR PETROL STATIONS (PTS-1, rev. PTS-U5-v7)
Revision: R08 Review date: 12 June, 2024

ORDER INFORMATION

Variant of PTS-1 controller supply is marked with PTS1-y-z, where


- y – type of supply:
o “PCB” in case if PTS-1 controller is supplied in a view of electric board;
o “BOX” in case if PTS-1 controller is supplied installed in metal box with hermetic inputs for
connection of wires and a button for power supply switching;
o “SDK” in case if PTS-1 controller SDK is supplied installed in metal box with hermetic inputs for
connection of wires and a button for power supply switching;
- z – variant of supply:
o 001 – variant of supply with installed terminal blocks for controller ports
o 002 – variant of supply without terminal blocks for controller ports (connection is made using
connectors for stubs)

Examples of order:
- order of PTS-1 controller in a view of electric board: PTS1-PCB-001;
- order of PTS-1 controller installed in a metal box: PTS1-BOX-001;
- order of PTS-1 controller SDK: PTS1-SDK-001