OTWO_SPECIFICATION-SHEET_LETTER_PRINT_CPAP_REV1_MAR2019
OTWO_SPECIFICATION-SHEET_LETTER_PRINT_CPAP_REV1_MAR2019
OTWO_SPECIFICATION-SHEET_LETTER_PRINT_CPAP_REV1_MAR2019
CPAP has been proven to provide an effective A Luer port is located on the device to attach
method of treating respiratory distress a pressure gauge. However, the accuracy SMALL AND LIGHTWEIGHT
from CHF. The use of CPAP is now being of the CPAP level, at the fixed flow settings Complete system weighs only 4oz (0.1 Kg)
extended to other respiratory problems to noted on the device, makes the use of a
LOW OXYGEN CONSUMPTION
provide symptom relief and avoid the need gauge unnecessary. The ambient air intake Only 8 - 25L/min for 5 - 25 cm H2O of CPAP
for intubation and ventilation of the patient port and the location of the in-line oxygen
and ICU admission. The O-Two Single-Use hose are designed to eliminate the possibility SIMPLE TO USE
Flow control adjustment to set CPAP level
“Open CPAP” Delivery System provides of accidental occlusion, removing the risk
incredibly accurate CPAP delivery for such a of barotrauma due to the patient or rescuer WIDE CPAP RANGE
compact device. By minimizing the pressure inadvertently blocking the port. Ideal for 5 - 25 CM H2O
drop on inspiration and the peak pressure on the treatment of the respiratory impaired
expiration, the O-Two Single-Use “Open CPAP” patient suffering from a range of obstructive DECREASED WORK OF BREATHING
Open circuit imposes no work on the patient
Delivery System produces a more uniform pulmonary diseases, the O-Two Single-Use
CPAP pressure throughout the respiratory “Open CPAP” Delivery System is a simple, cost COMFORTABLE AND SECURE
cycle. This provides a lower work of breathing effective alternative to invasive ventilation and HEAD HARNESS
Soft, conforming Neoprene material does not slip.
for the patient when compared to other, possible intensive care admissions.
commonly used, pre-hospital devices. COST EFFECTIVE
Low purchase price and low oxygen
consumption compared to other devices.
Air Cushion Mask
Neoprene Harness
Head Harness Hook Ring
Oxygen Tubing
Vectored
Flow Valve
FLOW RATE
EASY TO USE (L/min) 8 10 12 15 20 25
The adjustment of the CPAP level is achieved by adjusting the output flow from
PRESSURE
your oxygen therapy regulator or wall outlet. The setting selections noted on (cmH2O) 5.0 8.0 10.0 15.0 20.0 25.0
the device provide an accurate constant airway pressure at each flow setting.
OXYGEN
(%)* 54 59 62 67 73 77
As this is an “Open” system, the device allows unrestricted inspiratory flows,
since the patient has access to ambient air. Nebulizer treatments can be provided CYLINDER
DURATION 52 42 35 28 21 17
“in line”, with the nebulizer positioned between the face mask and the CPAP unit. D Tank (415L) MIN MIN MIN MIN MIN MIN
ORDERING INFORMATION
CONFIGURATION 1 REPLACEMENT ITEMS
CPAP system only
01CV0211-cs - o_two CPAP System (Large Adult) 01CV0210-CS - O-Two Disposable Open Circuit
c/w face mask (size 5) and head harness (Case/10) CPAP Valve c/w oxygen supply tubing (Case/50)
01CV0212-cs - o_two CPAP System (Adult)
c/w face mask (size 4) and head harness (Case/10)
01CV0213-cs - o_two CPAP System (Child)
c/w face mask (size 3) and head harness (Case/10) 01CV0220-CS - O-Two Single-Use CPAP Nebulizer System c/w
6 l/min Flow Adapter, T-Piece, Updraft Nebulizer with Oxygen
Supply Tubing (Case/10)
CONFIGURATION 2 02RT1301-CS - O-Two Single-Use CPAP Nebulizer
CPAP system with Manometer T-Piece (Case/10)
01CV8009-CS - O-Two Replacement Neoprene Head Harness
01CV0217-cs - o_two CPAP System (Large Adult)
System (Case/5)
c/w Adult Cuffed Facemask (size 5), Head Harness System, Flow
Vector Valve with Manometer and Oxygen Supply Tubing (Case/10)
01CV0218-cs - o_two CPAP System (Adult)
c/w Adult Cuffed Facemask (size 4), Head Harness System, Flow
Vector Valve with Manometer and Oxygen Supply Tubing (Case/10)
01CV0219-cs - o_two CPAP System (Child)
SPECIFICATIONS
c/w Child Cuffed Facemask (size 3), Head Harness System, Flow
CPAP RANGE 5 - 25 cm H2O
Vector Valve with Manometer and Oxygen Supply Tubing (Case/10)
REQUIRED THERAPY FLOW RATE 8 - 25 L/min
DIMENSIONS (CPAP DEVICE ONLY) 1.6” dia x 2.3”
CONFIGURATION 3
(40.6mm dia x 58.3 mm)
WEIGHT WITH FACE MASK AND TUBING 4 Oz. (0.1 Kg.)
CPAP system with Manometer and nebulizer INPUT CONNECTION Oxygen Therapy Barb
01CV0224-cs - o_two CPAP System (Large Adult) with Nebulizer PATIENT FACE MASK CONNECTION 22ml
c/w Adult Cuffed Facemask (size 5), Head Harness System, OPERATING TEMPERATURE -18oC to +50oC
(0oF to 122oF)
pressure manometer, nebulizer with tubing and preset flow
restrictor and “T” piece(Case/10) RELATIVE HUMIDITY FOR STORAGE -40oC to +60oC
(-40oF to 140oF)
01CV0225-cs - o_two CPAP System (Adult) with Nebulizer AND OPERATING USE
c/w Adult Cuffed Facemask (size 4), Head Harness System,
pressure manometer, nebulizer with tubing and preset flow
restrictor and “T” piece(Case/10)
01CV0226-cs - o_two CPAP System (Child) with Nebulizer
c/w Adult Cuffed Facemask (size 3), Head Harness System,
pressure manometer, nebulizer with tubing and preset flow
restrictor and “T” piece(Case/10)
www.otwo.com
45A Armthorpe Road, Brampton, ON, Canada, L6T 5M4
Telephone: +1 905 792-OTWO (6896) N.A. Toll Free: +1 800 387 3405
Facsimile: +1 905 799 1339 Email: [email protected]