Rapport de Test
Rapport de Test
EN 10204 requirements:
Item 1 Pipes
Material properties Test (AC name) Test standard Conditions Unit Results
Density: 2,7 g/cm³ Vacuum test logging IACS Req 2021 13 mbar(a) (mAWP) hr 48
Linear expansion coefficient Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
at 20°C: 23,4 µm/m°C
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
Melting temperature: 220 Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
°C (ISO11357-1/-3 dry
conditions)
Thermo test 1 hr at 150°C to Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
determine material quality
(ISO580)
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
www.airnet-system.com
Yield strength: 140 Mpa Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles N/A
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles
Yield strength: 140 Mpa Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) 114 - 200
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
www.airnet-system.com
Melting temperature: 220 Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
°C (ISO11357-1/-3 dry
conditions)
Thermo test 1 hr at 150°C to Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
determine material quality
(ISO580)
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) 89-194
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles N/A
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles
Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles N/A
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles
www.airnet-system.com
Yield strength: > 80 MPa Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles N/A
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles
Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
Yield strength: 140 Mpa Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) 123 - 153
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
www.airnet-system.com
Melting temperature: 220 Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
°C (ISO11357-1/-3 dry
conditions)
Thermo test 1 hr at 150°C to Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
determine material quality
(ISO580)
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles > 3x10^6
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles > 3x10^6
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles > 3x10^6
Leak tightness test logging ASME B31.3 17,6 bar(g) (1,1 x MAWP) hr 48
Burst test IACS Req 2021 64 bar(g) (4 x MAWP - max 200 bar(g)) bar(g) > 64
Vibration test IACS Req 2021 frequency 100 Hz - amplitude +/- 0,06 mm (MAWP) cycles N/A
frequency 45 Hz - amplitude +/- 0,5 mm (MAWP) cycles
frequency 10 Hz - amplitude +/- 1,5 mm (MAWP) cycles
www.airnet-system.com