0184860SBY
0184860SBY
9L | 350 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
*EPA Certified Prime ratings are not available in the US or its Territories Image used for illustration purposes only
ANSI C62.41
STANDARD FEATURES
Battery Voltage
Amps 0 0 0 Wr*BATTERY VOLTS Hi
Hz = 0.0 kW = 0 ACK More (1–3) COMMON ALARM
®
AUTO OFF MAN.
•
HOME
16 Channel Remote Trending Alarms and Warnings Spelled Out (No Alarm Codes)
• 0.2 msec High Speed Remote Trending
• Alarm Information Automatically Annunciated
Digital H Control Panel- Dual 4x20 Display on the Display
RS-232/485 Communications
• All Phase Sensing Digital Voltage Regulator
• All Phase AC Voltage
• 2-Wire Start Capability
• All Phase Currents
• Date/Time Fault History (Event Log)
• Oil Pressure
• Isochronous Governor Control
• Coolant Temperature
• Waterproof/Sealed Connectors
• Coolant Level
• Audible Alarms and Shutdowns
• Engine Speed
• Not in Auto (Flashing Light)
• Battery Voltage 2 of 6
• Frequency
SD350 | 12.9L | 350 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
CONFIGURABLE OPTIONS
ENGINEERED OPTIONS
CONTROL SYSTEM
○ Dealer Supplied AHJ Requirements
3 of 6
SD350 | 12.9L | 350 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
ENGINE SPECIFICATIONS
ALTERNATOR SPECIFICATIONS
4 of 6
SD350 | 12.9L | 350 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
OPERATING DATA
POWER RATINGS
Standby
Three-Phase 120/208 VAC @0.8pf 350 kW Amps: 1,214
Three-Phase 120/240 VAC @0.8pf 350 kW Amps: 1,053
Three-Phase 277/480 VAC @0.8pf 350 kW Amps: 526
Three-Phase 346/600 VAC @0.8pf 350 kW Amps: 421
COOLING
Standby
Coolant Flow gpm (Lpm) 145 (552)
Heat Rejection to Coolant BTU/hr (kW) 792,960 (232)
Inlet Air cfm (m3/min) 19,070 (539.7)
Maximum Operating Radiator Air Temperature °F (°C) 122 (50)
Maximum Ambient Temperature (Before Derate) See Bulletin No. 0199280SSD
Coolant System Capacity gal (L) 13 (49.2)
Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12)
ENGINE EXHAUST
Standby Standby
Rated Engine Speed RPM 1,800 Exhaust Flow (Rated Output) cfm (m3/min) 2,988 (84.6)
SPEC SHEET
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards. 5 of 6
Standby - See Bulletin 10000018933
Prime - See Bulletin 10000018926
SD350 | 12.9L | 350 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
OPEN SET
Usable
Run Time
Capacity L x W x H - in (mm) Weight - lbs (kg)
H Hours
- Gal (L)
No Tank - 137.5 (3,493) x 57.6 (1,463) x 67.8 (1,722) 5,377 - 7,330 (2,439 - 3,325)
7 183 (693) 137.5 (3,493) x 57.6 (1,463) x 80.8 (2,052) 6,325 - 8,278 (2,869 - 3,755)
L W 17 438 (1,658) 137.5 (3,493) x 57.6 (1,463) x 92.8 (2,357) 6,637 - 8,590 (3,011 - 3,897)
27 693 (2,623) 137.5 (3,493) x 57.6 (1,463) x 104.8 (2,662) 6,973 - 8,926 (3,163 - 4,049)
37 946 (3,581) 208.3 (5,292) x 57.6 (1,463) x 108.8 (2,762) 8,402 - 10,335 (3,811 - 4,697)
52 1,325 (5,016) 277.8 (7,055) x 57.6 (1,463) x 107.2 (2,722) 9,417 - 11,370 (4,272 - 5,158)
SPEC SHEET
* All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed
installation drawings.
6 of 6
Generac Power Systems, Inc. | P.O.Box 8 | Waukesha, WI 53189 Part No. 0184860SBY
P: (262) 544-4811 ©2020 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Rev. M 09/22/2020