1. A single effect short tube vertical evaporator is to be constructed to concentrate CO4 L3 (15)
2. 9000 kg/hr of sodium hydroxide solution containing 40 percent (by weight) of CO4 L3 (15)
concentrated to 20% solids in a single effect evaporator. The feed enters at 25°C.
The steam chest is fed with saturated steam at 110°C. The absolute pressure
maintained in the evaporator is such that the water will boil at 55°C. The boiling
point elevation for the boiling solution (20% solids) is 15°C over that of water.
Specific heat of feed solution can be taken as that of water.
Latent heat of vaporization of water at 55°C is 2370 kJ/kg. Specific heat of water
vapor in the temperature range of 55 to 90°C can be assumed to be constant at 1.871
kJ/kg°C. Latent heat of steam at 110°C is 2230 kJ/kg. The overall heat transfer
coefficient, under normal operating conditions would be 2500 W/m2°C.
A vertical short-tube evaporator with the following specifications is available.
Page 1 of 3
Check whether it is suitable for the above duty.
Tube:
OD = 100 mm; thickness = 1.5 mm; pitch = triangular 125 mm; length = 1220
mm, number of tubes = 626.
Downtake: ID = 1500 mm.; OD = 1520 mm.
Tube sheet: Diameter = 3400 mm; Thickness = 36 mm.
Vapor drum: Height = 3000 mm; ID of shell = 3400 mm; Thickness = 12 mm.
4. A short tube vertical evaporator is to be designed for concentrating a salt solution CO4 L3 (15)
from 1% by weight of salt to 1.5% by weight of salt. The feed rate is 10,000 lb/hr
and the temperature of feed is 100 oF. The operating pressure is 1 atm in the vapour
space and steam is supplied at a pressure 5 psig (227 oF). If the overall heat transfer
coefficient of evaporation is 250 Btu/(hr.ft2 oF), design a evaporator. Assume that
the boiling point elevation is negligible and the properties of salt solution similar to
that of water.
5. An evaporator is used to concentrate 4536 kg/h of a 20% solution of NaOH in water CO4 L3 (15)
entering at 60oC to a product of 50% solids. The pressure of the saturated steam used
is 172.4 kPa and the pressure in the vapour space of the evaporator is 11.7 kPa. The
overall heat transfer coefficient is 1560 W/m2.K. Design the evaporator.
Name
KKE20CH046-RAJLA KP
KKE20CH061-VISHNUPRIYA M
KKE20CH052-SREELAKSHMI ASOKAN
KKE20CH030-INDU MOHAN S
KKE20CH028-GOKUL KRISHNA T S
1
KKE20CH057-THEJUS P V
KKE20CH066-Salvin M Varghese
KKE20CH011-ANSHA ABOOBACKER P K
KKE20CH036-MUHAMMED FARIS AMEEN K P
KKE20CH026-FATHIMATH SHAFNA P T
KKE20CH056-THEJA MOORTHY K
KKE20CH020-DEEPAJA SHABU
KKE20CH042-NIHARA HEMANTH
KKE20CH015-ARYAKRISHNA V R
KKE20CH014-ARJUN K
2
KKE20CH064-Jaick Thomas
KKE20CH009-ANASWARA UNNI
KKE20CH059-UNNIMAYA M
LKKE20CH073-GOPIKA N
KKE20CH048-SHAMILA P
Page 2 of 3