16M55 Spec Sheet RevH
16M55 Spec Sheet RevH
16M55 Spec Sheet RevH
16M55
PowerKit ESP/PRP/DCP Diesel Engine
1
Baudouin.com
16M55
ESP/PRP/DCP Diesel Engine
Customer benefits
Warranty terms – 2 yrs unlimited PRP, 4 yrs/800h ESP
Low fuel consumption across the range
Extended mean time between overhauls (MTBO)
Standard Equipment
Engine and block Cast iron cylinder block with inspection door per cylinder
Cast iron cylinder liners, wet type and replaceable valves guides and seats
Hardened steel forged crankshaft with induction hardened journals,crank pins and radius
Lube oil cooled light alloy pistons with high performance piston rings
Air intake and exhaust system Top mounted turbocharger optimized for gen-set application
Special rear mounted air filter with restriction indicator
Exhaust manifold and turbocharger shield for heat isolating
Electrical System 24 V DC electric starter motor and battery charging alternator
Low oil pressure & high water temperature sensors
Baudouin.com
16M55
ESP/PRP/DCP Diesel Engine
Dimensions and dry weight (mm/kg)
H
L W
PK.S.308.EN.06.22 Moteurs Baudouin reserves the right to modify these specifications, without notice. Document not contractual.
16M55G2640/6 1800 4161 1953 2468 11500
16M55G2800/6 1800 4161 1953 2468 11500
16M55G3000/6 1800 4161 1953 2468 11500
16M55G3300/6^ 1800 4161 1953 2468 11500
Ratings definitions
Emergency Standby Power (ESP)
Emergency Standby Power is the maximum power available Continuous Power (COP)
for a varying load for the duration of a main power network Continuous Power is the maximum power available for
failure. The average load factor over 24 hours of operation an unlimited period of use at a constant load factor. No
should not exceed 70% of the engine’s ESP power rating. overload capability is allowed.
Typical operational hours of the engine is 200 hours per
year, with a maximum usage of 500 hours per year. This Prime Rated Power (PRP)
includes an annual maximum of 25 hours per year at the ESP Prime Power is the maximum power available for
power rating. No overload capability is allowed. The engine unlimited hours of usage in a variable load application.
is not to be used for sustained utility paralleling applications. The average load factor should not exceed 70% of the
engine’s PRP power rating during any 24 hour period.
Data Centre Power (DCP) An overload capability of 10% is available, however,
Data Centre Power is defined as being the maximum this is limited to 1 hour within every 12 hour period..
power which a generating set is capable of delivering while
supplying a variable or continuous electrical load and during 1) All ratings are based on operating conditions under ISO 8528-1,
unlimited run hours. Depending on the sites to supply and ISO 3046, DIN6271. Performance tolerance of ±5%.
2) Test conditions: 100 kPa, 25°C air inlet temperature,
the availability of reliable utility, the generating set relative humidity of 30%, with fuel density 0.84 kg/L.
manufacturer is responsible to define what power level he is Derating may be required for conditions outside these;
able to supply to fulfil that requirement including hardware please contact the factory for details.
or software or maintenance plan adaptation
Baudouin.com