PowerEdge R470 - Supplementary
PowerEdge R470 - Supplementary
The PowerEdge R470 Supplementary document is intended as a supplementary document for the 17G PowerEdge
R470 Administration and Maintenance course.
Copyright © 2024 Dell Inc. or its subsidiaries. All Rights Reserved. Dell Technologies, Dell and other trademarks are trademarks of
Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
Feature Comparison
Risers
Thermal Components
Block Diagram
Lesson 1 of 6
Feature Comparison
Jason Lee
16x DDR5 DIMMs @4800 MT/s, RDIMM, 128 16x DDR5 16 DIMM @ 6400 MT/s (1 DPC), 5200 MT/s (2
Memory
GB DPC)
Security
15G-class Security (SPI interface) 17G-class Security TPM 2.0 (NPCT760JABYX)
(TPM)
8 DIMMs
Ranks per DIMM and Data Width Capacity 1 DPC Speed 2 DPC Speed
1Rx8 16 GB - -
2Rx8 32 GB 6400 -
2Rx4 64 GB 6400 5200
2Rx4 96 GB - -
2Rx4 128 GB - -
The figure below illustrates the high level DDR5 implementation plan for the 1-socket platform with two slots per channel.
Intel’s convention is to have DIMM slot0 further away from the CPU than slot1 within the same channel. The population
rule should follow DDR5 Memory diagram as shown as below.
Risers
Jason Lee
Slot Mapping
Front Rear
Location Card Support RF1d R2q R4b
BOSS BOSS
PCIe Gen4
RC0 BOSS (optional) BOSS 3 BOSS x4 (1C 25.2 W BOSS J_BOSS
connector)
Rear:
x4 optional
BOSS PCIe Gen5
and 1 x16 Onboard OCP x16 (OCP OCP_NIC
onboard OCP OCP 5 OCP 75 W J_OCPNIC
(optional) 4C+ 3.0
connector)
PCIe Gen5
31 OCP x16 (OCP J_SL1,
Flop OCP 75 W SL1, SL2
4C+ J_SL2
connector)
RC3 RF1d
PCIe Gen5
Front: 2 x16
32 OCP x16 (OCP SL11,
FLOP OCP Flop OCP 75 W J_R5
4C+ SL12
(Gen5) and x4
connector)
optional BOSS
PCIe Gen4
BOSS (optional) BOSS 34 BOSS x4 (1C 25.2 W BOSS J_BOSS
connector)
Hybrid Full PCIe Gen5 SL11,
R2Q 1 75 W J_R5
Riser Height x16 SL12
3 PCIe Gen4
RC6 BOSS (optional) BOSS BOSS 25.2 W BOSS J_BOSS
x4
Rear: 2 x16 FH
(Gen5) with x4
optional boss Full
and x16 R4b Cabled 4 PCIe Gen5 SL13,
75 W J_R4
onboard OCP Riser Height x16 SL14
Riser Configuration
Riser Configuration for RC0, RC1, RC2 RC3 and RC4.
R1d
R1d is created for front OCP cards.
RF1c
R2K Riser
R2U
R2V
R2q
R2t
Riser 4 Types
R4a
R4b
Lesson 4 of 6
Thermal Components
Jason Lee
Fan Type
4056 VHP fan (HPR Silver) J7DTN ASSY,FAN,HPR,SLVR,40X56,1U,17G CPU TDP <=350 W
4056 STD fan (Brickfielder) 9P02K ASSY,FAN,STD,40X56,1U,17G CPU TDP <= 250 W
(Left) VHP fan and (Right) STD fan
EXT HSK front shroud 5PTF0 SHRD,FRONT,EXT,R470 Bundled with EXT HSK configuration
Remote HSK front shroud FFX7G SHRD,FRONT,REMOTE,R470 Bundled with Remote HSK configuration
(Left) EXT HSK air shroud and (Right) Remote HSK air shroud.
Thermal Restriction
Configuration
Legend:
Supported at 35 °C
Maximum 30 °C support
Maximum 25 °C support
Not supported
Extended HSK and VHP fan is required for a 350 W CPU TDP supporting at
35 °C ambient.
Supports CPU TDP up to 250 W with extended HSK and Brickfielder fan in
8x E3.S cold aisle config and 8x2.5” SAS/SATA (NVMe RAID/direct) config
at 35 °C ambient.
Supports CPU TDP up to 225 W with extended HSK and Brickfielder fan on
Ubuntu 22.04
Block Diagram
Jason Lee