CSB Catalog
CSB Catalog
CSB Catalog
Model CSB
• Single Width Blowers
• Commercial & Industrial Applications
April
2024
Model CSB
Centrifugal Single Width Blowers
Greenheck’s single-width centrifugal fans are designed to provide efficient and reliable operation for
commercial and industrial applications. We manufacture our products with state-of-the-art equipment
and undergo quality control testing to ensure a trouble-free start-up.
•B
elt drive design allows for easy field • Tested and reliable product design
performance adjustments
Certifications
Greenheck India Pvt Ltd. certifies that the CSB models shown
herein are licensed to bear the AMCA Seal. The ratings shown
UL Listed Power ventilator
are based on tests and procedures performed in accordance with
UL File no. E529585
AMCA publication 211 and comply with the requirements of the
AMCA Certified Ratings Program. The AMCA Certified Ratings UL 762 Power Ventilator for Restaurant Exhaust Appliances
Seal applies to air performance and FEI ratings only. Performance UL File no. E529585
certified is for installation type B: Free inlet, Ducted outlet. UL Power Ventilator for Smoke Control Systems (400ºC for 2 hours)
Power rating (BHP/kW) does not include transmission losses. UL File no. E529585
Performance ratings do not include the effects of appurtenances
(accessories).
Certified data may be found in Greenheck’s Computer Aided Product Selection program CAPS®
The model number code is designed to completely identify the unit. The correct code letters must be
specified to designate configurations. The remainder of the model number is determined by the size and
performance selected from the model CSB Sound and Air performance supplement.
Wheel Diameter
Kw
315 710
355 800 Backward
Inclined
400 900
450 1000
500
560
630 Class I
2
Building Segments
and Applications
We are known worldwide as a leading manufacturer that provides high-quality air movement, control,
conditioning and distribution equipment. Our HVAC (heating, ventilation, air-conditioning) products
efficiently move air in a variety of commercial and industrial spaces.
Typical Applications
• General or fume exhaust
• Kitchen smoke and grease exhaust
• Stairwell pressurization
• Filtered exhaust
• Industrial process exhaust
3
Standard Construction
Accessories
Standard Construction and Configuration Wheels
• Volume up to 42,000 cmh Greenheck’s single width, single inlet, backward-inclined
• Static pressure up to 1,500 Pa wheels provide high efficiency with low sound levels.
Wheels are balanced statically and dynamically to AMCA
• Galvanized steel
G2.5 standard/AMCA Standard 204-05 for smooth
• Greenheck’s Permalock™ lock seam scroll vibration-free operation.
• Backward-inclined (BI) wheels:
Steel: (315-1000 mm) Backward-Inclined (BI)
OD
Aluminum: (315-710 mm)
INLET OD L
Aluminum Steel
• Slip-fit flange OD
PermalockTM Housing
Permalock™ housings use a
mechanically fastened seam
instead of welding. This
airtight and watertight housing
construction uses the same
structural support as the all-
welded housings. Permalock
construction is an excellent
value engineering option for
applications up to 8.5 in. wg
(2.1 kPa).
4
Configurations
Class of Construction
Fan class refers to a construction level designed to
handle a given fan outlet velocity and pressure. As
the fan performance requirements increase, the fan
construction (material gauge, shaft diameter, motor Typical Installation -
size) must also increase to handle the new workload. Commercial Kitchen (Grease)
CSB models target Class 0 & I performance ranges Installation must include a means for inspecting, cleaning
for backward inclined fans, as defined by AMCA and servicing the exhaust fan.
pressure class.
BISW-36 • Fans selected for grease removal must include a
25 mm (1 inch) drain connection.
25
60 60 75 100 125 150 200 RPM
BHP
• An outlet guard is strongly recommended when the
50% WOV % WOV
Density 0.075 lb/ft3
Density 1.2 kg/m3
fan discharge is accessible.
E
50 60% WOV
URV
20
70% WOV Fan • An upblast discharge is recommended.
C
Static Pressure (Pa x 100)
EM
40
Z W
• The fan must discharge a minimum of 1016 mm (46
Static Pressure (in. wg)
YST
20
40
82
80% WOV
inches) above the roofline and the exhaust duct must
SS
15 30 19 Y X
THI
00
25 be fully welded to a distance of 457 mm (18 inches)
OF
17
27
10
16
HE
15
00
15 00
• No dampers are to be used in the system.
Isolation Base
OT
20 13 90% WOV
71
TT
10
EC
12
7½ 00
5
EL
10
5 51 Upblast Discharge
TS
900
NO
3
750 Optional
DO
600 Companion
0 0 Flange
0 10 20 30 40 50 60 70
Volume (cfm x 1000)
Fan
Z W
0 20 40 60 80 100 **1016 mm Weatherhood
3
(40 inches) 3 Wheel
Volume (m /hr x 1000) Y X Diameters
5
CSB Dimensional Information
OD OD
A
INLET OD L L
Slip Fit Flange H (8 holes)
Foot PrintPCD
& Slot Dimensions
Punched Flange
Size X Y M N P QID Footprint
315 765 305 835 350 11 16
355 789 362 859 406 11 16 OD
400 893 405 943 453 11 16
450 936 497 986 548 13 18 L
500 960 545 1020 607 13 18 H (8 holes)
560 1038 620 1098 682 13 18
630 1136 700 1196 750 13 Punched
18 Flange
710 1301 760 1361 822 13 18
800 1465 915 1525 982 13 18
(Slot Reference)
900 1622 1005 1682 1072 13 18
1000 1638 1075 1708 1142 13 18
All dimensions are in millimeters.
Q
Slot
6
CSB Dimensional Information
7
Design and Selection Support
Our Commitment
As a result of our commitment to continuous improvement, Greenheck reserves the
right to change specifications without notice.
International
00.INT.2031 R7 4-2024
Copyright © 2024 Greenheck Fan Corp.
Greenheck India: 201-202, 2nd Floor, Landmark Cyber Park, Sector-67, Gurgaon, Haryana-122018 • www.greenheck.co.in
Greenheck U.S.A.: P.O. Box 410 • Schofield, WI 54476-0410 • Phone +1 (715) 359-6171 • www.greenheck.com
Greenheck India Private Ltd has been independently audited and confirmed as being in conformity with ISO 9001:2015 and ISO 14001:2015.