Rheodyne Manual Sample Injector Valves
Rheodyne Manual Sample Injector Valves
Rheodyne Manual Sample Injector Valves
Shaft End
Rotor Seal Rotor Seal Groove
Stator Face
Stator Face Seal
Stator
MBB Passage
Pump Column
MBB Passage
Position A
Rotor Seal Grooves Rotor Seal Grooves
Position B Position C
Waste Waste
6 6
1 Waste 1 Waste
5 5
Needle Port
2 2
4 Needle Port 4
7725 and 9725 Sample Injectors Pump 3 Pump 3
HPLC Accessories
Eleven interchangeable loops from 2µL to 5mL are available. A 20µL Sample Injector Ordering Information
loop is supplied. These loops are not interchangeable with those used Cat. No. Description
on the Model 7125 injector. 7725 Sample injector, SS
7725I Sample injector, SS, position sensing switch
Reliable design, simple maintenance
9725 Sample injector, PEEK
High-pressure switching takes place between a polymeric rotor seal
9725I Sample injector, PEEK, pos. sensing switch
and ceramic stator face. The ceramic surface allows these injectors to
make 30,000 injections (in a clean system) before the rotor seal
needs replacing, a task requiring only twenty minutes. You can
tighten the seal from the front of the injector by turning the easily 7125 Syringe Loading Sample Injector
accessible pressure screw.
The Model 7125 can use both partial and
“Make-Before-Break”
complete loop filling. Valve accessories
The flow is not interrupted when the injector is switched between
can be found on pages 180-183.
LOAD and INJECT, a benefit when using flow-sensitive detectors,
Syringes used with the 7125 must have
fragile columns, or pumps that are disturbed by flow or pressure
the 22 gauge blunt tip needle.
transients. A passage in the stator face makes new connections before
old ones break. This patented make-before-break or “MBB” design Model 7725 replaces model 7125.
is an improvement over injectors which use a bypass; it is easy to Cat. No. Description
troubleshoot and does not dilute sample. 7125 Sample injector, includes 20µL sample loop
HPLC Accessories
7410-073 5µL Loop disc
Cat. No. Description
7012 Loop filler port
8125 Micro-scale injector with 5µL loop
9013 Needle port
87942 2.5µL RN syringe
7770-01 Replacement needles, 6/pk
2 1 2 1
Model 7520 Internal Pump Sample Pump Sample
Sample Loop Sample Loop
Sample Chamber Micro-Scale Injector
The Model 7520 uses a small hole Waste Column Waste Column
drilled in a flat rotor as an internal 4 5 4 5
sample chamber for precise sample
injection. The rotor, which is Position
PositionAA(LOAD)
(LOAD) Position
PositionBB(INJECT)
(INJECT)
sandwiched between two stators, is Flow paths of the load and inject positions of model 7410.
available in 0.2, 0.5, and 1µL
volumes; 0.5µL is standard. The
7520 requires the complete-filling
method of loading the internal
sample chamber. Excess sample is
required to completely flush mobile
phase from the chamber.
The schematic diagram shows the rotor (drawn as if it were a slider) Sample Needle Port
Sample Needle Port
in the LOAD position. The sample chamber is loaded by inserting a
syringe needle into the built-in needle port. The space between the Inlet Stator Sample Chamber Sample Chamber
needle tip and rotor surface contains only 0.3µL so there is very little
sample wastage. Rotating the handle to the INJECT position places Pump Pump
The outlet stator passage is 0.13mm (.005 inch) diameter. A column Waste Waste
connecting tube of matching I.D. is supplied installed in the outlet Outlet Stator
port. The 1/16 inch O.D., 5cm long tube makes it easy to connect Column
Column
microbore columns of various designs.
Valve accessories can be found on pages 180-183.
Position
PositionAA(LOAD)
(LOAD) Position B B(INJECT)
Position (LOAD)
Cat. No. Description
7520 Internal sample chamber micro-scale injector Flow path of model 7520 internal sample chamber micro-scale injector.
7520-011 0.2µL Rotor
7520-012 0.5µL Rotor
7520-013 1.0µL Rotor
from a syringe into a needle port in the handle. Flow rates can be as
while in the LOAD position. At least two loop volumes should be
high as 800mL per minute because the 1/8 inch tubing has low
used. The model 7012 loop filler port or 9013 needle port is
resistance and because the flow continues uninterrupted when you
recommended for this.
switch to INJECT thereby protecting the pump from over-pressure.
Valve accessories can be found on pages 180-183.
High pressure ratings permit you to use columns with very small
particles. The rating of the non-metal model is 276 bar (4,000 psi) Two Position, Six Port Switching Valves
and that of the stainless steel model is 345 bar (5,000 psi). The Cat. No. Description
needle port and syringe are never exposed to high pressure. They are 7000 Switching valve, SS, 1/16"
automatically isolated when you turn to INJECT. 7000L Switching large bore valve, SS, 1/16"
Both models are available in an “i” version with a built-in position 3000-038 Switching valve, SS, 1/8"
sensing switch (reed switch). Both models are supplied with a 10mL 3000 Switching valve, PEEK, 1/8"
loop and 1/8 inch fittings for all ports. RheFlex PEEK fittings must Two Position, Ten Port Switching Valves
be used with the PEEK injector. A port adapter (optional accessory) 7610-400 Switching valve, SS, 1/16"
can be used to connect 1/16 inch tubing. 7610-600 Switching valve, PEEK, 1/16"
Valve accessories can be found on pages 180-183. Sample Injector Valves
Cat. No. Description 7010 SS injector (complete loop filling only)
3725 PEEK Preparative injector 9010 PEEK injector (complete loop filling only)
3725i PEEK Preparative injector w/sensing switch 7012 Loop filler port
3725-038 SS Preparative injector 9013 Needle port
3725i-038 SS Preparative injector w/sensing switch
1 Waste 1 Waste
5 5 Sample Injector Sample Injector
1 6 1 6
Needle Port
2 2
2 5 2 5
4 Needle Port 4
Pump 3 Pump 3
3 4 3 4
HPLC Accessories
3030-038 3-way SS switching valve, 1/8" However, it is useful to use the sixth port for a bypass/flush-out tube.
3030 3-way PEEK switching valve, 1/8" A second 7060 is placed at the column outlets to direct the effluent to
the detector. Note that two separate 7060 valves are required.
The internal passages of the 7060 are 0.41mm I.D., with a total
internal volume less than 2µL.
Cat. No. Description
7060 6 position selection valve, SS, 1/16"
7060L 6 position L-bore selection valve, SS, 1/16"
9060 6 position selection valve, PEEK, 1/16"
3060-038 6 position selection valve, SS, 1/8"
3060 6 position selection valve, PEEK, 1/8"
Electrically Actuated Valves
Four-line BCD code for random access to any position
6 6 EV700-105 6 position selection valve, SS, 1/16"
1 1
EV750-105 6 position selection valve, PEEK, 1/16"
5 5
1
2
Model 7040 4-way Valve 6
7 5
The Model 7040 is a six-port two-position valve. The internal flow 3
4
passages are identical to the Model 7000 but the external loop across
ports 1 and 5 converts it functionally to a 4-way valve. It exchanges
two streams: 2 -3 and 4-6 to 2-6 and 4-3. 1 2 3 4 5 6
5
3
4
Detector
Six column selection using two model 7060 switching valves
Vespel blend rotor seals have an operating range from 0 to 10. Tefzel
blend and PEEK blend rotor seals have a pH range from 0 to 14. 7125-008 Needle guide (for analytical front loading injectors)
Strong oxidizing acids such as concentrated nitric and sulfuric are not 7010-015 Isolation seal
compatible with PEEK.
Stators are available in 316 SS and PEEK. Our materials of
construction have been researched and selected for their physical and
mechanical strength.
HPLC Accessories
valve. PEEK loops do not require this precaution because the ferrule can slide and reposition
itself along the tube when the fitting is reinserted into a port. Upchurch SS Loops for 7725 and 7725i
1950 5µL sample loop
Size designations are nominal. Sizes vary from nominal values usually less than 15%. 1951 10µL sample loop
Accuracy and precision in partial filling require that no more than half the loop volume be 1952 20µL sample loop
loaded. Precision in complete filling requires that at least two loop volumes be loaded. 1955 50µL sample loop
1960 100µL sample loop
SS Loops for 7125 and 7010 Injectors PEEK Loops for 9725 and 9010 Injectors 1962 200µL sample loop
Cat. No. Sample Loop Volume Cat. No. Sample Loop Volume 1965 500µL sample loop
7020 5µL sample loop 7755-015 2µL (9725 only) 1971 1mL sample loop
7021 10µL sample loop 9055-020 5µL sample loop 1972 2mL sample loop
7022 20µL sample loop 9055-021 10µL sample loop 1875 5mL sample loop
7023 50µL sample loop 9055-022 20µL sample loop 1876 10mL sample loop
7024 100µL sample loop 9055-023 50µL sample loop 1877 20mL sample loop
7025 200µL sample loop 9055-024 100µL sample loop
7026 500µL sample loop 9055-025 200µL sample loop Upchurch PEEK Sample Loops
7027 1mL sample loop 9055-026 500µL sample loop 1800 2µL sample loop
7028 2mL sample loop 9055-027 1mL sample loop 1801 5µL sample loop
7029 5mL sample loop 9055-028 2mL sample loop 1802 10µL sample loop
9055-029 5mL sample loop 1803 20µL sample loop
SS Loops for 7725 and 7750 Injectors 1805 50µL sample loop
7755-020 5µL sample loop 9055-033 10mL sample loop
1810 100µL sample loop
7755-021 10µL sample loop PEEK Loops for 3725 Injectors: 1811 150µL sample loop
7755-022 20µL sample loop 3055-018 2mL sample loop 1812 200µL sample loop
7755-023 50µL sample loop 3055-019 5mL sample loop 1814 250µL sample loop
7755-024 100µL sample loop 3055-023 10mL sample loop 1815 500µL sample loop
7755-025 200µL sample loop 3055-025 20mL sample loop 1820 1mL sample loop
7755-026 500µL sample loop Titanium Loops 1821 2mL sample loop
7755-027 1mL sample loop 7055-021 10µL sample loop 1822 5mL sample loop
7755-028 2mL sample loop 7055-022 20µL sample loop 1825 10mL sample loop
7755-029 5mL sample loop 7055-023 50µL sample loop 1826 20mL sample loop
SS Loops for 8125 Injector 7055-024 l00µL sample loop
8020 5µL sample loop 7055-025 200µL sample loop
8021 10µL sample loop 7055-026 500µL sample loop
8022 20µL sample loop 7055-017 lmL sample loop
8023 50µL sample loop 7055-028 2mL sample loop
SS Loops for 3725-038 Injectors 7055-029 5mL sample loop
3065-018 2mL sample loop
3065-019 5mL sample loop
3065-023 10mL sample loop
3065-025 20mL sample loop