WPG275*8

DIESEL GENERATING SET

GENERATING SET RATINGS


50Hz – 1500rpm @ 0.8p.f.

Voltage PRP ESP


V kVA kWe kVA kWe
415/240 250 200 275 220
400/230 250 200 275 220
380/220 250 200 275 220

PRODUCT FEATURES
Electrical system
Engine •24 Vdc electric starter motor and battery charging
•Cast iron frame style body structure alternator
•One-piece forged crankshaft • LOP + HWT sensors
•Separate cast iron cylinder heads and replaceable
dry cylinder liners Air intake and exhaust system
•Aluminum alloy pistons with oil cooling gallery • Mid-position and below inlet turbocharger optimized
or genset application
• Special rear mounted air filter with restriction indicator
Cooling system • Exhaust manifold shield for heat isolating
•Radiator and hoses supplied separately
•Thermostatically-controlled system with belt driven
Alternator
coolant pump and pusher fan
•Brushless, 4 Pole, IP23 drip-proof revolving field
design
•Class H insulation and Class H temperature rise
Fuel system
•Low reactance with 2/3 pitch windings on the stator
•P type fuel injection pump and injector for higher inject
•Direct-coupled by flexible disc
pressure
• Duplex fine filter and water separation filter assembly •Sustained overcurrent >300% in 10 sec
with transparent cup for better efficiency •Direct drive centrifugal blower fan cooling

Control module
Lubrication system •DSE control module is ideal for a wide control range to
•Flat bottom large capacity oil pan manage, monitor, and diagnose quickly and easily.
•Spin-on full-flow lube oil filter •Display status message Provide protection Auto
•High capacity gear driven lube oil pump shutdown at fault detection

Weichai Power Co., Ltd.


197 A, Fushou East Street, High-Tech Development Zone, Weifang, China 261061
GENERATING SET SPECIFICATIONS
Governor and regulation class In accordance to ISO 8528-5 Class G2 performance
Phase number and connection 3 phase, 4 wires, Y-type
Cooling method Closed looped water-cooled
Starting method DC 24V Electric starter
Steady-state voltage deviation ≤± 2.5%
Steady-state frequency band ≤1.5%

ENGINE
Brand / Model Weichai / WP10D264E200
Gross Power kWm ESP - 264 / PRP - 240
Cylinder / Type / Aspiration 6 / In-line / Turbocharged and Aftercooled
Bore x Stroke mm 126 x 130
Displacement L 9.726
Compression ratio 17:1
Brake Mean Effective Pressure kPa ESP – 2171

COOLING SYSTEM
Type of Coolant Liquid (water + 50% antifreeze)
Total Cooling System Capacity (with Radiator) L 35
Max coolant temperature – shutdown °C 105
Cooling Fan Airflow m3/min 415

LUBRICATION SYSTEM
Operating Temperature range before Engine °C 78 -105
Oil fuel consumption ratio based on engine fuel
g/kW.hr ≤ 0.2%
consumption data
Total system capacity (including filters) L 30
Type of oil filter Spin-on full flow filter

Weichai Power Co., Ltd.


197 A, Fushou East Street, High-Tech Development Zone, Weifang, China 261061
FUEL SYSTEM
Type of fuel filter Spin-on fuel filter
Min. internal diameter of the supply pipe mm 12
Min. internal diameter of the return pipe mm 12
Max. fuel return restriction Bar 0.5
Max. fuel inlet temperature °C 50
Fuel supply flow L/hr 169
Fuel Consumption (Tolerance +3%)
Rating gr/kWh L/hr
100%ESP 201.6 63.4
100%PRP 199.1 56.9
75% PRP 197 42.2
50% PRP 198.3 28.3
25% PRP 215.5 15.4

EXHAUST SYSTEM
Exhaust Gas temperature after the turbocharger °C 600
Exhaust Gas flow m3/min ESP – 50.6 / PRP – 46.8
Max. Exhaust back pressure mBar 60

ALTERNATOR
Brand / Model WEICHAI / WHA-250-4/0.4 LEROY-SOMER / TAL A46 D
Rated Current 361A 361A
Coupling / No. of Bearing Direct / Single Direct / Single
Winding Pitch 2/3 2/3
Type of Excitation Self-excitation Self-excitation
Cooling type Air Air
Voltage regulation method AVR AVR
Insurance Class H Class H
Temperature rise Class H Class H
Protection Grade IP23 IP23
Efficiency at 0.8p.f.@100% load 92.7% 91.3%

CONTROL MODULE
Back-lit LCD display
3 Phase generator and 3 Phase Mains monitoring
Monitoring speed, frequency, voltage, current, oil
pressure, coolant temperature and fuel level
Display warning, shutdown and engine status
information
Hours counter provides accurate information for
monitoring and maintenance.

Weichai Power Co., Ltd.


197 A, Fushou East Street, High-Tech Development Zone, Weifang, China 261061
STANDARD CONDITIONS

Standard operating environment: ambient temperature is 5℃~40℃,the altitude is less than 1000m,the
relative humidity is less than 90%(25℃),and there is no dust, sand dust, salt fog, mold, condensation
environment, etc.
If the operating environment exceeds the above requirements, please contact the factory and
consult.

Ambient adaptability protection measures for alternators


Ambient type Ambient description Measures of protection
The air is clean and dry, the humidity is
≤90%, and the distance from the
General Ambient coastline is ≥ 30km; Non-industrial standard configuration
ambient (chemical splash, acid-base
steam, corrosive environment, etc.)
The humidity above 90% or
Humid Ambient Anti-condensation heating
condensation occurs
Anti-condensation heating;
Salt fog crystals are produced in Spray three-proof paint on winding
Salt spray Ambient seaside (< 30km from the coastline) or surface;
island Ambient Spraying epoxy protection for parts and
structures.
The ambient where mining, building Improve the protection level of
Dust Ambient construction, desert Gobi or sandstorm the alternator to IP44;
occur Install filters.
If you need to use protective measures beyond the standard, please contact the factory and consult.

Special working condition

If the operating conditions of the generator meet the following conditions, please contact the factory
and consult.
 Multistage parallel operation
 Grid-connected operation
 As the main power supply, it runs continuously for a long time
 The load includes a high power motor type load
 Capacitive load
 Special ambient such as high temperature, cold and plateau

Weichai Power Co., Ltd.


197 A, Fushou East Street, High-Tech Development Zone, Weifang, China 261061
Ratings definitions
Emergency Standby Power (ESP):
Emergency Standby Power is the maximum power
available for a varying load for the duration of a main
power network failure. The average load factor over
24 hours of operation should not exceed 70% of the
engine’s ESP power rating.
Typical operational hours of the engine are 200 hours
per year, with a maximum usage of 500 hours per
year. This includes an annual maximum of 25 hours
per year at the ESP power rating. No overload
capability is allowed. The engine is not to be used for
sustained utility paralleling applications.

Prime power (PRP):


Prime Power is the maximum power available for
unlimited hours of usage in a variable load application.
The average load factor should not exceed 70% of the
engine’s PRP power rating during any 24 hour period. This outline drawing is to provide representative configuration
An overload capability of 10% is available; however, details for Model series only.
See respective model data sheet for specific model outline
this is limited to 1 hour within every 12 hour period. drawing number.
Do not use for installation design

Ddimension and Weight


Dim “A” Dim “B” Dim “C” Dry wt.*
Structure Model
mm mm mm kg
Open WPG275F8 2999 1170 1920 2440
Silence(Elite) WPG275L8 3900 1350 2050 3160
Silence(Premium) WPG275L8 4200 1350 2040 3360
* Note: Weights represent a set with standard features. See outline drawings for weights of other configurations.

Codes and standards

This generating set is designed and manufactured in


ISO 9001 facilities certified to ISO 9001. ISO 8528 This generating set has been designed
to comply with ISO 8528 regulation.

The CE marking is only valid when equipment is used in


a fixed installation application. Material compliance
declaration is available upon request.

For more information contact your local Weichai distributor or visit www.weichai.com