Standard Steel Details

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NOTES
1. FOR STRUCTURAL GENERAL NOTES REFER TO
DRAWING AS-0000-C-00002.
A A

1 1
2. DISTANCE FROM TOP OF BEAM TO FIRST
90 90 22 DRILLED CORNER 300 Ø22 DRILLED CORNER 300
- - HOLE SHALL BE 90 WHEN MAIN BEAM FLANGE
CUT AND GROUND CUT AND GROUND
EXCEEDS 25 THICK BOLT GROUP TO MOVE TO SUIT.
'n' NUMBER OF BOLT 'n' NUMBER OF BOLT TO ACHIEVE SMOOTH TO ACHIEVE SMOOTH
'WS t' WEB SIDE PLATE 55 'WS t' WEB SIDE PLATE 55 20 20
ROWS REFER TABLE 1 ROWS REFER TABLE 1 TRANSITION, REFER TRANSITION, REFER
THICKNESS REFER THICKNESS REFER 3. DISTANCE FROM TOP OF BEAM TO COPE SHALL
DETAIL 9 35 REFER NOTE 3 DETAIL 9 35 REFER NOTE 3 3
TABLE TABLE 20 TYP BE 55 WHEN MAIN BEAM FLANGE EXCEEDS

20 TYP
25 THICK.

70 70 70 70 70

70 70 70 70 70
REFER NOTE 2 REFER NOTE 2
4. WHERE NO DESIGNATION IS INDICATED ON DESIGN
B
DRAWINGS, USE THE STANDARD OR PREFERRED B
WEB SIDE PLATE
DETAILS AS A DEFAULT.
NOT SHOWN
TOP OF COMPENSATING
FOR CLARITY
FLANGE FLUSH WITH 5. NON PREFERRED DETAILS SHALL ONLY BE USED
75 x 10 FLAT TOP OF COPE WHEN NOMINATED ON THE DESIGN DRAWINGS.
TOP OF COMPENSATING WEB SIDE
COMPENSATING FLANGE

35 TYP
FLANGE FLUSH WITH PLATE WEB SIDE PLATE
AT TOP COPE ONLY 6. WHERE TWO BEAMS ARE CONNECTED TO A
TOP OF COPE NOT SHOWN
OPPOSITE SIDE TO

TYP
COLUMN WEB USING A FHEP1 WITH THE SAME

20
FOR CLARITY
'W' 20 20 WEB SIDE PLATE 22 DRILLED CORNER NUMBER OF BOLT ROWS, ONE ADDITIONAL ROW
SUPPORTED
SUPPORTED SUPPORTED 'W' FOR ALL BEAMS CUT AND GROUND OF BOLTS IS TO BE PROVIDED BELOW ONE BEAM
TYP BEAM MEMBER
BEAM MEMBER BEAM MEMBER MAIN BEAM 20 300 PFC, 310UB/UC SUPPORTED 20 TO ACHIEVE SMOOTH TO FACILITATE CONSTRUCTION. THE OVERALL
MAIN BEAM MAIN BEAM MAIN BEAM
MEMBER AND ABOVE, ONLY BEAM MEMBER TRANSITION, REFER CONSTRUCTION SEQUENCE IS TO BE CONSIDERED
C C
MEMBER MEMBER MEMBER
TO BE USED WHERE DETAIL 9 WHEN SELECTING THE ADDITIONAL BOLT
SPECIFIED ON DESIGN LOCATIONS.
ELEVATION END VIEW ELEVATION PLAN
WEB SIDE PLATE WS1 FULL HEIGHT WEB SIDE PLATE FHWS1 DRAWINGS OR WHEN
SINGLE WEB COPE MORE THAN 30% OF DOUBLE WEB COPE FLANGE COPE 7. WHERE TWO BEAMS ARE CONNECTED TO THE
THE WEB DEPTH SAME MAIN BEAM MEMBER USING A FEP1 THE
HAS BEEN REMOVED GREATER BEAM GAUGE SHALL BE USED.
COPE AND COMPENSATING FLANGE DETAILS
8. ALL INTERNAL CORNERS SHALL BE DRILLED AND
DETAIL 2 DETAIL 1 GROUND SMOOTH, OR WITH WRITTEN APPROVAL
DETAIL 1
- FROM THE ENGINEER MAY BE FLAME CUT AND
-
D - GROUND SMOOTH. A SMOOTH TRANSITION IS TO D
BE ACHIEVED. REFER TO DETAIL 9.

SUPPORTED BEAM MEMBER SUPPORTED BEAM MEMBER SUPPORTED BEAM MEMBER


TO COLUMN FLANGE GAUGE TO COLUMN WEB GAUGE TO COLUMN WEB GAUGE
REFER TABLE REFER TABLE REFER TABLE

PLAN PLAN SIM 1 PLAN


STANDARD GAUGE -
1 TYPICAL TOP AND 'W'
'n'
BOTTOM FLANGE 'W' COLUMN WEB
E - E

NUMBER OF BOLT NUMBER OF BOLT


35 SUPPORTED SUPPORTED 35 TYP
ROWS REFER TABLE ROWS REFER TABLE
BEAM MEMBER BEAM MEMBER

70 70 70 70 70
70 70 70 70 70

COMPENSATING FLANGE
REFER NOTE 2 REFER NOTE 2
REFER DETAIL 1
35 TYP

THIS DRAWING

F 'EP t', END PLATE F


'EP t' END PLATE
THICKNESS
THICKNESS
35 TYP

REFER TABLE
REFER TABLE

70
'W'
'W' SIM 1 COPE BOTTOM FLANGE

35
'W'
SUPPORTED - WHEN BOLT ROW AND
MAIN BEAM
BEAM MEMBER COLUMN FLANGE FLANGE CLASH
MEMBER
EXTENDED FULL HEIGHT
END PLATE REFER NEARSIDE FLANGE NOT NEARSIDE FLANGE NOT
NOTE 7 SHOWN FOR CLARITY SHOWN FOR CLARITY
G ELEVATION END VIEW ELEVATION TYPE 1 TYPE 2 END VIEW G

BEAM TO COLUMN FLANGE ELEVATION ELEVATION TYPICAL LAYOUT


FLEXIBLE END PLATE FEP BEAM TO COLUMN WEB BEAM TO COLUMN WEB
FULL HEIGHT END PLATE FHEP
DETAIL 3
BEAM END PLATE WEB SIDE PLATE
- NUMBER OF FLAT OF WELD STANDARD NUMBER OF FLAT OF WELD
DETAIL 4 BEAM
1 1 1 MEMBER ROWS OF PLATE SIZE GAUGE ROWS OF PLATE SIZE COMMENTS
90 90 90 90 -
SIZE BOLTS THICKNESS 'W' BOLTS THICKNESS 'W'
- - -
'n' MIN 'EP t' UNO 'n' MIN 'EP t' UNO
55
H H
35 TYP SUPPORTED 55 SUPPORTED 35 TYP 200PFC 2 10 6 45 2 10 6 MAX FLG COPE LENGTH = 185
BEAM MEMBER BEAM MEMBER 20
230PFC 2 10 6 45 2 10 6 MAX FLG COPE LENGTH = 185
35

35
10 PLATE 10 PLATE
250PFC 2 10 6 55 2 10 6
70

60 70

60 70

70
300PFC 3 12 6 55 3 10 6

380PFC 4 12 6 55 4 12 6

6
6

150UC 1 10 6 70, 90 N/A - - 'STANDARD GAUGE' SHALL


35

35

BE DETERMINED BY THE
200UC 2 12 8 90, 140 2 10 6
10 PLATE 10 PLATE MAIN BEAM WEB OR FLANGE OF THE
SUPPORTED SUPPORTED 250UC 2 12 8 90, 140 2 10 6 SUPPORTING COLUMN. SMALLER
MEMBER
I BEAM MEMBER MAIN BEAM MAIN BEAM MAIN BEAM BEAM MEMBER VALUE IS DEFAULT I
310UC 3 16 8 90, 140 3 12 6
MEMBER MEMBER MEMBER
200UB 2 10 6 70 2 10 6 N/A TO 200UB18

250UB 2 10 6 70 2 10 6 N/A TO 250UB26


TYPICAL CONNECTION 150 PFC PREFERRED NON PREFERRED PREFERRED
310UB 3 12 6 90 3 12 6 N/A TO 310UB32
TYPICAL CONNECTION 180 PFC TYPICAL CONNECTION 180 PFC TYPICAL CONNECTION 150 UB 360UB 4 12 6 90 4 12 6

410UB 4 16 8 90 4 12 6

DETAIL 5 DETAIL 6 DETAIL 7 DETAIL 8 460UB 5 16 8 90 5 12 6


- - - - 530UB 6 16 8 140 6 12 6

J 610UB 7 16 8 140 7 12 6 J
R 11 MIN
NUT
NOTATION ON DESIGN DRAWINGS 700WB 8 20 8 140 8 16 6
BOLTED CONNECTIONS 150 PFC/UB & 180 PFC ONLY
LOCK NUT 800WB 8 20 8 140 8 16 8
FHWS1/t20/n9/CF-T AND B 900WB 10 20 8 140 10 16 8

1000WB 11 20 8 140 11 16 8

FHWS1/t20/n9/CF-T AND B 1200WB 13 20 8 140 12 16 8


800WB192
DENOTES COMPENSATING FLG REQD 350WC 3 20 10 140 4 20 8
AND NOTATED AS T.B OR T AND B DETAIL 9 400WC 4 20 10 140 4 20 8
200W B278

200W B278
5

LOCK NUT ARRANGEMENT


000W B21

DENOTES ROWS OF BOLTS


K - REFER NOTE 7.13 ON 500WC 6 20 10 140 6 20 8 K
DENOTES PLATE THICKNESS
ALL CORNERS SHALL BE DRG AS-0000-C-00002 TABLE 1, REFER NOTE 4
DENOTES CONNECTION TYPE
DRILLED AND GROUND SMOOTH
1

WHERE /-/ NOTATION IS MADE


OR FLAME CUT AND GROUND
THIS INDICATIVE A DEFAULT VALUE 3
SMOOTH WITH WRITTEN APPROVAL 0.2 0.1 0 0.2 0.4 0.6 Metres
FOR THE RELATIVE ITEM
OF THE ENGINEER. A SMOOTH
WHERE NO NOTATION IS MADE ON DESIGN TRANSITION IS TO BE ACHIEVED
PLAN - BEAMS DRAWINGS USE DEFAULT VALUES SCALE 1 : 10

INFORMATION AND REPRESENTATIONS THIRD ANGLE


AS-0000-C-00002 CIVIL MINE STANDARDS GENERAL NOTES DETAILS AA RG 15.05.2008 ISSUED FOR INTERNAL / CLIENT REVIEW FT BR DRAWN S.BIDDLE 01.09.2008
ON THIS DRAWING ARE THE
0 SB 05.09.2008 ISSUED FOR USE FOR PN 9353 MF LH TRACED INTELLECTUAL PROPERTY OF THE
ZE B1

RIO TINTO GROUP UNLESS SPECIFICALLY


REFERENCES

REFERENCES

ONS

ONS

1 SB 08.01.2009 200-380 PFC ADDED TO TABLE 1 PD BR CHECKED M.FISTONICH 05.09.2008 IDENTIFIED OTHERWISE. ALL RIGHTS
INCLUDING USE RESERVED PROJECTION
SHEET SI

L L
SI

SI

2 FPG COMPENSATING PLATES REVISED PD BR SUPT DRAFT L.HARRIS 05.09.2008


REVI

REVI

SCALE 1:10
3 SL 02.07.2021 ISSUED FOR USE FOR JN28514. MAJOR UPDATE. PG CL LEAD ENG. ALL SITES
DRAWING NUMBER REV
PROJECT ENG. B.RUGGIERO 06.03.2009 STRUCTURAL MINE SITE STANDARDS
APPROVED I.FINDLAY 06.03.2009 BOLTED CONNECTIONS AS-0000-S-00001 3
687

REV BY DATE DESCRIPTION CKD APP REV BY DATE DESCRIPTION CKD APP DETAILS PROJECT/JOB NUMBER
980 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

UNCONTROLLED WHEN PRINTED