Procedure
1. Log in as an administrator to the machine on which you want to install the Historian server.
2. Run the InstallLauncher.exe file.
3. Select Install Historian.
The welcome page appears.
4. Select Next.
The license agreement appears.
5. Select the Accept check box, and then select Next.
The Where do you want to install Historian? page appears.
Give Feedback
6. If needed, change the default installation drive of the Historian server, and then select Next.
https://www.ge.com/digital/documentation/historian/version2022/t_hgs_installing_single_server_historian.html 1/4
24/11/2023, 15:56 Install the Historian Server Using the Installer | Historian 2022 Documentation | GE Digital
7. If needed, change the default folder of the log files, and then select Next. If you want to include the Historian server in a cluster, enter the path to the shared
folder of the cluster.
The Proficy Authentication Service page appears.
Only if you want to use Web-based Clients (such as Configuration Hub, Trend Client, the Web Admin console, and REST APIs), you need Proficy Authentication.
Otherwise, you can skip this step. If you use Web-based Clients, Proficy Authentication is required for user authentication. It provides identity-based security
for applications and APIs. It supports open standards for authentication and authorization, including Oauth2.
8. If you want to use Web-based Clients, select the Yes, I want to use Web-based Clients check box, and provide values as described in the following table.
Field Description
Give Feedback
Proficy Authentication server name Enter the name of the machine on which the Proficy Authentication server is
installed. If the machine uses a fully qualified domain name (FQDN), provide
the FQDN. By default, the local hostname is considered.
Public https port Enter the port number used by the Proficy Authentication service. The
default value is 443. Ensure that this port number matches the one on the
TCP Port Assignments page during Web-based Clients installation.
Note:
You can install a Proficy Authentication service using Operations Hub or Historian Web-based Clients. You can provide the URL of an existing
Proficy Authentication instance. Or, if a Proficy Authentication service is not available, you can install it during Web-based Clients installation.
https://www.ge.com/digital/documentation/historian/version2022/t_hgs_installing_single_server_historian.html 2/4
24/11/2023, 15:56 Install the Historian Server Using the Installer | Historian 2022 Documentation | GE Digital
If you change the Proficy Authentication server for Web-based Clients later, you must change the Proficy Authentication server for the Historian
server as well. You can do so using the Proficy Authentication Configuration tool without the need to install the Historian server again.
9. Select Next.
The Historian Security Groups page appears.
Using Historian security groups provides an added layer of control over access to your Historian system.
10. If you want the installer to create Historian security groups, select the corresponding check box, and then select Next.
The Choose the type of install you want to perform page appears.
11. Select the type of the Historian server that you want to install, and then select Next.
Historian Single Server: This is for a stand-alone Historian system, which contains only one Historian server. This type of system is suitable for a small-
Give Feedback
https://www.ge.com/digital/documentation/historian/version2022/t_hgs_installing_single_server_historian.html 3/4
24/11/2023, 15:56 Install the Historian Server Using the Installer | Historian 2022 Documentation | GE Digital
The RemoteCollectorConfigurator utility: A command-line tool, which allows you to manage collectors remotely. By default, it is located in the
C:\Program Files\GE Digital\NonWebCollectorInstantiationTool folder. For instructions on using this utility, refer to About Installing and
Managing Collectors Remotely.
The Proficy Authentication Configuration tool: A utility that allows you to specify the Proficy Authentication server details to match with the Proficy
Authentication server used by Web-based Clients. By default, it is located in the C:\Program Files\Proficy\Proficy Historian\x64\Server
folder. For instructions on using this tool, refer to Change the Proficy Authentication Server.
Give Feedback
https://www.ge.com/digital/documentation/historian/version2022/t_hgs_installing_single_server_historian.html 4/4