C264 OrderForm - (v.3 - 14)
C264 OrderForm - (v.3 - 14)
MiCOM C264C/264
Disclaimer / Décharge / Descarga
Disclaimer
Our policy is one of continuous development. Accordingly the design of our products may change at any time.
Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide
and is intended for information purposes only.
Its contents do not constitute an offer for sale or advice on the application of any product referred to in it.
We cannot be held responsible for any reliance on any decisions taken on its contents without specific advice.
Décharge
Nous avons une politique de développement permanent.
Par conséquent, la conception de nos produits risque de subir des modifications à tout moment.
Bien que nous nous efforcions de tenir notre documentation à jour, ce brochure ne devra être considérée
que comme guide à des fins d’information seulement.
Son contenu n’a pas titre d’offre de vente ou d’assistance technique sur l’application d’un produit mentionné.
Descarga
Nuestra política se basa en un desarrollo continuo.
Por este motivo, el diseño de nuestros productos puede experimentar cambios en cualquier momento.
Realizamos el máximo esfuerzo para producir documentación actualizada. Estas páginas sólo tienen valor informativo.
Su contenido no constituye en modo alguno una proposición de venta o asesoramiento en relación con ninguno de los productos
mencionados.
Declinamos toda responsabilidad por las decisiones que se adopten basándose en su contenido sin notificación al respecto.
MiCOM C264 CORTEC FOR C264-V3/V4, fully assembled device Version: V3_14
Variants Notes /
Order N° Ext. N°
MiCOM C264C/C264 - Modular Computer for Bay Controller, RTU, PLC application
MiCOM C 2 6 4 0 1 1 1
CORTEC CODE Synthesis (for export to Word Docs) :
MiCOM C2640111
Basic Model and Components
Package rack 4U (CAS2xx) + FBP2xx
1) 1)
Case 40 T for use wo. CT/VT (Compact size), IP52, pin-terminal connection, 6 slots C
1) 1)
Case 40 T for use with CT/VT (Compact size), IP52, pin-terminal connection, 4 slots S
1) 1)
Case 80 T for use without CT/VT (Medium size), IP20, pin-terminal connection, 15 slots L
1) 1)
Case 80 T for use with CT/VT (Medium size), IP20, pin-terminal connection, 14 slots M
Front panel (GHU2xx)
Front Panel Leds and L/R switch - IP52 protection -GHU210 (40TE) or GHU211(80TE) 0
Front Panel with Leds + Graphic Display LCD +L/R switch -GHU200(40TE)or GHU201(80TE) - IP52 prot. 1
Simple Blind front panel : GHU220 (40TE ) or GHU 221(80TE) 12)
2
Detachable Front Panel with Graphic Display 40TE (GHU200) + Simple Blind Front panel (GHU22x) 12)
3 Select the cable lenght
Detachable Front Panel with Graphic Display 80TE (GHU201) + Simple Blind Front panel (GHU22x) 12)
4 Select cable
Detachable Front Panel with Leds 40TE (GHU210) + Simple Blind Front panel (GHU22x) 12)
5 Select cable
Detachable Front Panel with Leds 80TE (GHU211) + Simple Blind Front panel (GHU22x) 12)
6 Select cable
8)
Language (including: Front panel labels, HMI)
French ( English) 0
English (English) 1
Spanish (English) 2
German (English) 3
Power supply and legacy ports (BIUxxx)
about BIU241 :Nominal auxiliary voltage (+/- 20%) for PS - Wetting voltage for 2 digital inputs
BIU241-A01 : VA,nom: 24 VDC / Nominal wetting voltage for 2DI: 24 V DC A
BIU241-A02 : VA,nom: 48 to 60 VDC / Nominal wetting voltage for 2DI: 48/60 V DC E
BIU241-A03 :VA,nom: 110 to 125 VDC / Nominal wetting voltage for 2 DI: 110/125 V DC I
BIU241 A04 : VA,nom: 220 VDC and 115 to 230VAC / Nominal wetting voltage for 2 DI: 220 V DC M
about the BIU100 : only to be interfaced to the Redunded Power supply rack : RPS280
15)
BIU100 : 12V auxiliary voltage, 2 non isolated serial links R Consult us for details
8)
Factory setted legacy ports N°1/2 on BIU board
Definition : Port N°2:RS232or RS422 or RS485 ; Port N°1: RS232or RS485
Port N°2: RS232 ; Port N°1: RS232 1
Port N°2: RS232 ; Port N°1: RS485 2
Port N°2: RS485 ; Port N°1: RS485 6
CPU and Base Communications (CPU260)
14)
Power PC processor board with Ethernet port(s) , 2 serial links, IRIGB input- CPU260-based
CPU260(Type2) , with 1 Ethernet RJ45, IRIG-B input, 2 Serial links (Ref CPU2 = 45196300A5) 5
CPU260(Type2)-based with Pack 2 = IRIG-B input +2 serial links+ 100BaseFL MultiMode Ethernet 6 Consult us
CPU270(Type3) , with 2*Ethernet RJ45, 64Mb FlashMemory, 1 ppm Oscillator accuracy (Ref CPU270 = 2071590A02 ) 8 Consult us
CPU270(Type3) , with 2*Ethernet RJ45, 64Mb FlashMemory, 50ppm Oscillator accuracy (Ref CPU270 = 2071590A01 ) 9 Consult us
8)
For CPU with 2 serial links: Factory setted legacy ports N°3/4
Configuration of the legacy Ports N°3/4 :RS232 (non isolated), RS485, Optical settable no serial link
Port N°3:RS232 (non isolated) ; Port N°4: RS232 (non isolated) 1
Port N°3: RS485(ECU201) ; Port N°4: RS485(ECU201) 5
Port N°3: Optical(ECU200) ; Port N°4: Optical(ECU200) 9
Inputs / outputs boards and Ethernet-based switch boards
0)
Manufacturing process
Automatic affectation (as standard) of the I/O modules in the basic rack 0
Preferred affectation (customized with extra cost) of the I/O modules in the basic rack 1 consult us
With TMU220 (measurement 4*I / 5*U) : Inom: 1 A / 5A, Vnom: 50 to 250 VAC - 9) S -M F Consult us
Nominal wetting voltage for digital inputs (DIU200(-) or DIU220 (+) or CCU200 (-) or DSP210(-) 18)
) U S=12)
VA,nom: 24 V DC (- to earth) DIU200-A01 board or CCU200-A01 board or DSP210-A01 0
VA,nom: 48/60 V DC (- to earth) - DIU200-A02 board or CCU200-A02 board or DSP210-A02 1
VA,nom: 110/125 V DC (- to earth) - DIU200-A03 board or CCU200-A03 board or DSP210-A03 2
VA,nom: 220 V DC (- to earth) : DIU200-A04 board or CCU200-A04 board or DSP210-A04 3
VA,nom: 110-125 VDC (-to earth) - DIU200-A03 board or CCU200-A07 board (input setted if > 68% Vn) 6 consult us
VA,nom: 48 V DC (+ to earth) -DIU220-A02 (+ to earth) or CCU200-A02 (- to earth) board or DSP210-A02 (- to earth) 9 consult us
VA,nom: 110-125V DC (+ to earth) -DIU220-A03 (+ to earth) or CCU200-A03 (- to earth) board or DSP210-A03 (- to earth) A consult us
Digital inputs (16 DI) module, each with 16 digital inputs (DIU200A0x or DIU220A0x) 3) 21)
S=12)
16 optically insulated inputs in 8 isolated groups
DIU200(or DIU220) quantity = 0 to 4 or 6 for 40TE racks, 0 to 9,A,B,C,D,E or F for 14 or 15 slots in 80TE racks X
Multi tension-peak-current Digital inputs (16 DI) module, each with 16 digital inputs DIU210 3) 13)
S=12)
16 optically insulated inputs in 8 isolated groups
check 13) for quantities
DIU210 quantity = 0 to 4 or 6 for 40TE racks, =0 to 9,A,B,C,D,E or F for 14 or 15 slots in 80TE racks X
Digital outputs (10 DO) module, each with 10 digital outputs (DOU200) 3)
S=12)
8 outputs NO contacts and 2 outputs NO/NC contacts
DOU quantity = 0 to 4 or 6 for 40TE racks, =0 to 9,A,B,C,D,E or F for 14 or 15 slots in 80TE racks X
Mixed (8 DI + 4 DO) module each with 8 digital inputs and, 4 digital outputs4) (CCU20x) 3)
S=12)
8 optically insulated inputs (in 4 isolated groups) and 4 direct command relays (2 NO contacts)
CCU quantity = 0 to 3 or 6 for 40TE racks, =0 to 9,A,B,C,D,E or F for 13 or 15 slots in 80TE racks 19)
X
3)
DC 4 Analog inputs module (C or V transducer connection) each with 4 analogue inputs (AIU201)
4 DC Analog Inputs in current or voltage (4 isolated groups) - Maximum of 6*AIU2xx in one case
AIU201 quantity = 0 to 4 or 6 for 40TE racks , =0 to 6 for 80TE racks X S=12)
3)
DC 8 Analog inputs module (Current),with 8 analogue inputs (AIU210)
8 DC Analog Inputs in current (4 isolated groups) - Maximum of 6*AIU2xx in one case
AIU210 quantity = 0 to 4 or 6 for 40TE racks , =0 to 6 for 80TE racks X S=12)
3), 16)
Analog output module (Currents) ,with 4 analogue ouputs (AOU200) Consult us
SWR204 or SWR 214 -With two 100BaseF MonoMode Ethernet ports (SC) + four 10/100BaseT Ethernet ports (RJ45) 7 refer note 21)
820425767.xls
C264 CORTEC Page 2
11/27/2024
MiCOM C264 CORTEC FOR C264-V3/V4, fully assembled device Version: V3_14
Variants Notes /
Order N° Ext. N°
MiCOM C264C/C264 - Modular Computer for Bay Controller, RTU, PLC application
MiCOM C 2 6 4 0 1 1 1
Ethernet-based Switch Dual Humming Unit (SWD20x) 3) S=12)
SWD202 or SWD212 - With two 100BaseF MultiMode Ethernet ports (ST) + four 10/100BaseT Ethernet ports (RJ45) A refer note 21)
SWD204 or SWD214 -With two 100BaseF MonoMode Ethernet ports (SC) + four 10/100BaseT Ethernet ports (RJ45) B refer note 21)
Communications
Ethernet-based SCADA communication protocol ( to upper levels SCADA, DCS, Master Station, ...)
Without 0
IEC 60870-5-104 1
10)
Legacy serial SCADA communication protocols (to upper levels: SCADA, DCS, Master station, etc)
Without 0
Up to two SCADA links in: IEC 60870-5-101, DNP3, Modbus 1
11)
Legacy IED communication protocols (To lower levels: Relays, PLC, RTU, etc)
Without 0
Up to 4 IEDs links in: DNP3, MODBUS, IEC 60870-5-103, IEC 60870-5-101 1
PLC Automation
6)
User applications
Disabled 0
Enabled ISaGRAF run-time for Programmable Logic, Automation, etc. 1
Softwares version
11)
Specific software version
No Software loaded N
Option CD3: No Software loaded, delivered with one CD-ROM including the C264 software (PACIS V3) C
Option CD4 : No Software loaded, delivered with one CD-ROM including the C264 software (PACIS V4) D
Option V4 : With the C264 current Software version loaded (for PACIS V4.xx) -No CD delivered R
Option V3 : With the C264 current Software version loaded (for PACIS V3.xx) -No CD delivered S
6)
Built in applications
Disabled 0
Synchrocheck/Voltage Regulation/ Autorecloser enabled 1
Cable Lenght for Detachable front Panel
No cable 0
Cable For Detachable Front Panel : 3 m 3
Wall Mounted Adaptater - for 40TE Racks (WMA 40TE) Ref = A00043409100031 Consult us
Wall Mounted Adaptater - for 80TE Racks - (under validation - Consult us) Consult us
Softwares :
6)
C264 Standalone Configuration tool - SCT Consult us
6)
PACIS SCE Configuration tool Consult us
6)
ISaGRAF software PLC Editor Consult us
6)
PACIS SMT System Management tool Consult us
Manuals :
Technical and Operation guides in English Consult us
CD-ROM documentation:
Technical and Operation guides - multilingual pdf documentations (English, French, Spanish and German) Consult us
The preferred affectation of the I/O modules will be defined separately with the "CUSTOMISATION" datasheet. This manufacturing
process induce extra costs. You are strongly advised to contact the marketing department to calculate the
associated extra cost.
1) Different racks exist depending of user-selected CT/VT(TMU) & basic case size :
For 40T case with TMU200 (Measurement CT/VT): CAS242 (Available slots: N=4) - For 40T case with TMU210 (Protection CT/VT): CAS242 (Available slots: N=3).
For 40T case without any TMUxxx (CT/VT) : CAS241 (Available slots: N=6).
For 80T case with TMU200 (Measurement CT/VT): CAS282 (Available slots: N=14) - For 80T case with TMU210 (Protection CT/VT): CAS282 (Available slots: N=13).
For 80T case without any TMUxxx (CT/VT): CAS281 (Available slots: N=15).
9) With TMU200 and TMU220, the option includes the DSP200 daughter board, plugged on the CPU260 module
With TMU210 the option includes the DSP210 daughter board plugged on the CPU260 module
- The DSP2x0 are using Floating-Point Digital Signal Processor (DSP)
10) The sum of communication links (legacy SCADA and IEDs) must not exceed the maximum communication ports available.
11) For Specific Software version complete the Software CORTEC (sheet C264 SOFT)
For C264-R multirack applications, Select " No software loaded"
12) For Detachable Front panel, define the lenght of the required cable ; the Blind panel size depend on the Rack size.
14) for CPU260:only one Ethernet Port available -> exclusion of use between RJ45 copper link and optical if required in option
15) BIU100 : only in association to RPS280 (consult marketing) ,
Do not exist for tropicalised /Varnished version
Warning : specific EMC levels for this power supply - consult Marketing before use
820425767.xls
C264 CORTEC Page 3
11/27/2024
MiCOM C264 CORTEC FOR C264-V3/V4 BASE racks Version: V3_14
Project : ### Notes /
Order N° Ext. N°
MiCOM C264C/C264 - Modular Computer for Bay Controller, RTU, PLC application ###
MiCOM C 2 6 B 5 1 0 U 0 0 0 0 0 0 0 0 1 1 1 N 1 0
CORTEC CODE Synthesis (for export to Word Docs) :
MiCOM C26B510U00000000111N10
Basic Model and Components
Package rack 4U (CAS2xx) + FBP2xx
Case 40 T for use wo. CT/VT (Compact size), IP52, pin-terminal connection, 6 slots 1) ###
###
C
Case 40 T for use with CT/VT (Compact size), IP52, pin-terminal connection, 4 slots 1) ###
S ###
Case 80 T for use without CT/VT (Medium size), IP20, pin-terminal connection, 15 slots 1) ###
###
L
Case 80 T for use with CT/VT (Medium size), IP20, pin-terminal connection, 14 slots 1) ###
###
M
Front panel (GHU2xx)
Front Panel Leds and L/R switch - IP52 protection -GHU210 (40TE) or GHU211(80TE) ### ###
0 ###
Front Panel with Leds + Graphic Display LCD +L/R switch -GHU200(40TE)or GHU201(80TE) - IP52 pro
######
###
1
Simple Blind front panel : GHU220 (40TE ) or GHU 221(80TE) 12) ###
###
###
2
Language (including: Front panel labels, HMI) 8) ###
###
###
French ( English) ### ###
0 ###
English (English) ###
###
###
###
1
Spanish (English) ### ###
2 ###
German (English) ###
###
###
###
3
Power supply and legacy ports (BIUxxx) ### ###
###
###
about BIU241 :Nominal auxiliary voltage (+/- 20%) for PS - Wetting voltage for 2 digital inputs ### ###
###
###
BIU241-A01 : VA,nom: 24 VDC / Nominal wetting voltage for 2DI: 24 VDC ### ###
###
###
A
BIU241-A02 : VA,nom: 48 to 60 VDC / Nominal wetting voltage for 2DI: 48/60 VDC ### ###
###
###
E
BIU241-A03 :VA,nom: 110 to 125 VDC / Nominal wetting voltage for 2 DI: 110/125 VDC ### ###
###
###
I
BIU241 A04 : VA,nom: 220 VDC and 115 to 230VAC / Nominal wetting voltage for 2 DI: 220 VDC ### ###
###
###
M
Factory setted legacy ports N°1/2 on BIU board 8) ### ###
###
###
Definition : Port N°2:RS232or RS422 or RS485 ; Port N°1: RS232or RS485 ### ###
###
###
Port N°2: RS232 ; Port N°1: RS232 ### ###
###
###
1
Port N°2: RS232 ; Port N°1: RS485 ### ###
###
###
2
Port N°2: RS485 ; Port N°1: RS485 ### ###
###
###
6
CPU and Base Communications (CPU260) ### ###
###
###
Power PC processor board with Ethernet port(s) , 2 serial links, IRIGB input- CPU260-based 14) ### ###
###
###
CPU270(Type3) , with 2*Ethernet RJ45, 64Mb FlashMemory, 1 ppm Oscillator accuracy (Ref CPU27### ###
######
###
8 ###
#REF! ### ###
######
###
######
For CPU with 2 serial links: Factory setted legacy ports N°3/4 8) ### ###
###
######
###
Configuration of the legacy Ports N°3/4 :RS232 (non isolated), RS485, Optical settable ### ###
### ###
### ###
Port N°3:RS232 (non isolated) ; Port N°4: RS232 (non isolated) ### ###
###
######
###
1 ###
Varnish I/O boards for installations demanding tropicalized conditions ### ###
### ######
No ### ###
### ######
###
0
Yes ### ###
### ######
###
1 Consult us
Transducerless Measurements Unit - Direct measuring value acquisition: AC inputs CT/VT 3)#########
### ### #########
Without ############ ### ######0###
with TMU200 ( measurement 4*I + 4*U) , Inom: 1 A / 5A, Vnom: 50 to 250 VAC - 9) ###S -M
###### ### ######1###
With TMU210 A01 (protection) : Vnom: 50 to 250 VAC, Iph=1A, In=1A, Io operating range= 0,1-40I
###S -M
###### ### ######2###
With TMU210 A01 (protection) : Vnom: 50 to 250 VAC, Iph=1A, In=5A, Io operating range= 0,1-40IoS -M 3 Consult us
With TMU210 A01 (protection) : Vnom: 50 to 250 VAC, Iph=5A, In=5A, Io operating range= 0,1-40IoS -M 4 Consult us
With TMU210 A01 (protection) : Vnom: 50 to 250 VAC, Iph=5A, In=1A, Io operating range= 0,1-40IoS -M 5 Consult us
With TMU210 A02 (protection) : Vnom: 50 to 250 VAC, Iph=1A, In=1A, Io operating range= 0,01-8IoS -M 6 Consult us
With TMU210 A02 (protection) : Vnom: 50 to 250 VAC, Iph=1A, In=5A, Io operating range= 0,01-8IoS -M 7 Consult us
With TMU210 A02 (protection) : Vnom: 50 to 250 VAC, Iph=5A, In=5A, Io operating range=0,01-8IoS -M 8 Consult us
With TMU210 A02 (protection) : Vnom: 50 to 250 VAC, Iph=5A, In=1A, Io operating range= 0,01-8IoS -M 9 Consult us
With TMU210 A03 (protection) : Vnom: 50 to 250 VAC, Iph=1A, In=1A, Io operating range=0,002-1IS -M A Consult us
With TMU210 A03 (protection) : Vnom: 50 to 250 VAC, Iph=1A, In=5A, Io operating range=0,002-1IS -M B Consult us
With TMU210 A03 (protection) : Vnom: 50 to 250 VAC, Iph=5A, In=5A, Io operating range=0,002-1IS -M C Consult us
With TMU220 (measurement 4*I / 5*U) : Inom: 1 A / 5A, Vnom: 50 to 250 VAC - 9) S -M F Consult us
820425767.xls Page 4
C264 BASE_CORTEC
11/27/2024
Basic Interface Unit BIU24x
board
PIN
Output relays
1 O2
2
3 O1
4 Watchdog
5
6
7 VIN VIN
+ +
- DI1 - DI2
8 - -
BACK
9
10
11 RS232/
12 RXD / T+ RS485 Serial
13 GND
link 1
14 TXD / T-
15 #
GND
16 RS232/
CTS
17 RS422
RXD / T+ Serial
18 TXD / T- RS485
RTS / R+ link 2
19
R- (RS422) #
20 DCD
21
22
Vaux Power
23 +
24 - supply
-
Central Processing Unit, CPU260
Ethernet-based and
optional communications
board
CONNECTO RS
1 2 3 4 5 6 7 8
10/100 Base-TX
Ethernet-based link
RJ -45 (female)
OPTIONAL LINKS:
100 Base-FX
Ethernet-based link
3 TXD / T+
6
Serial
2
8 7
5 GND
3
link 3
4
7 RTS
5
8 CTS #
1 DCD
RXD / T- RS232
2
1
TXD / T+
6
3 Serial
2
GND
3
5
8
link 4
4
RTS
7
5
8 CTS #
IRIG-B link
CPU270 Connector description :
BACK
Digital Output Unit DOU200
board
1
2 DO 1
3
4 DO 2
5
6 DO 3
7
8 DO 4
9
10 DO 5
11
BACK
12 DO 6
13
14 DO 7
15
16 DO 8
17
18
19
20
DO 9
21
22
23
DO 10
24
Circuit breaker CCU 20x
Control Unit
board
1 +
VIN
+
VIN
-
DI1 -
DI2
2 - -
3
4 +
VIN
+
VIN
-
DI3 -
DI4
5 - -
6
7 +
VIN
+
VIN
-
DI5 -
DI6
8 - -
9
10 +
VIN
+
VIN
-
DI7 -
DI8
11 - -
BACK
12
13 Digital Outputs
14 B
CO 1
15 A
16 A
17 B CO 2
18
19
20 B
CO 3
21 A
22 A
23 B CO 4
24
Digital Input Unit DIU20x
board
1 +
VIN
+
VIN
-
DI1 -
DI2
2 - -
3
4 +
VIN
+
VIN
-
DI3 -
DI4
5 - -
6
7 +
VIN
+
VIN
-
DI5 -
DI6
8 - -
9
10 +
VIN
+
VIN
-
DI7 -
DI8
11 - -
BACK
12
13 +
VIN
+
VIN
-
DI9 -
DI10
14 - -
15
16 +
VIN
+
VIN
-
DI11 -
DI12
17 - -
18
19 +
VIN
+
VIN
-
DI13 -
DI14
20 - -
21
22 +
VIN
+
VIN
DI15 DI16
- -
23 - -
24
Transducerless TMU 200 TMU210 : Protection Module :
Transducerless TMU 200
Measurement Unit Measurement Unit
1A connections Scheme under preparation
5A connections
Transducerless Transducerless
current inputs current inputs
PIN PIN N1
1 2 1 2 N2
N1
3 4 N2
3 4
C1
5 6 5 6 C2
C1
7 8 C2 7 8
B1
9 10 9 10 B2
B1
11 12 B2 11 12
A1
13 14 13 14 A2
A1
15 16 A2 15 16
17 18 Transducerless 17 18 Transducerless
voltage inputs voltage inputs
19 20 19 20
U1 U1
21 22 U2 21 22 U2
V1 V1
23 24 V2 23 24 V2
W1 W1
25 26 W2 25 26 W2
N1 N1
27 28 N2 27 28 N2
tection Module :
Definitions:
AC Alternative Current
AIU Analog Input Unit
Commonly Voltage or Current DC signals delivered by transducers
Bay Set of LV, MV or HV plants (switchs and transformer) and devices (Protective, Measurement…).
Usually around a Circuit Breaker and controlled by a bay computer.
BIU Basic Interface Unit
DC Direct Current
DCS Digital Control System
DI Digital Inputs
DIU Digital Inputs Unit
DO Digital Outputs
DOU Digital Output Unit
DSP Floating-Point Digital Signal Processor
I Current
IED Intelligent Electronic Device
IP52 IP52 environmental protection
Protected against dust and direct sprays of water up to 15 degrees from vertical - Indoor
The number 5 means that it is especially protected against the dust
The number 2 means that it is especially protected against projections of water
PC Personnal Computer
PLC Programmable Logic Controller
PQ Power Quality
VT Voltage Transformer