Type L6D Load Cell

Short Description

• Aluminium-alloy IP65 single point load cell Test certificate no. TC7868 Revision 1
• Colorless anodized C of C no R60/2000-NL1-12.52
• Suitable for pricing scales, bench scales, etc.
• Recommended maximum platform size: 250 x 350 mm Certificate no. 11-012

Available Models

Capacity Accuracy Full Article Description


3kg C3/C4/C5 L6D-C3/C4/C5-3kg-0.40B
5kg C3/C4/C5 L6D-C3/C4/C5-5kg-0.40B
6kg C3/C4/C5 L6D-C3/C4/C5-6kg-0.40B
8kg C3/C4/C5 L6D-C3/C4/C5-8kg-0.40B
10kg C3/C4/C5 L6D-C3/C4/C5-10kg-0.40B
15kg C3/C4/C5 L6D-C3/C4/C5-15kg-0.40B
20kg C3/C4/C5 L6D-C3/C4/C5-20kg-0.40B
30kg C3/C4/C5 L6D-C3/C4/C5-30kg-0.40B
35kg C3/C4/C5 L6D-C3/C4/C5-35kg-0.40B
40kg C3/C4/C5 L6D-C3/C4/C5-40kg-0.40B
50kg C3/C4/C5 L6D-C3/C4/C5-50kg-0.40B

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2022.12 L6D Rev12 [email protected]
Page 1/3 www.zemiceurope.com
Type L6D Load Cell

Technical Specifications L6D

Accuracy Class OIML R60 C3 OIML R60 C4 OIML R60 C5


Output Sensitivity ( = FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) kg 3, 5, 6, 8, 10, 15, 20, 30, 35, 40, 50
Max. Number of Load Cell Intervals nLC 3000 4000 5000
Ratio of min. LC Verification Interval Y = Emax / vmin 10000 15000 20000
Combined Error %FS ≤± 0.020 ≤± 0.015 ≤± 0.010
Creep Error (30 minutes) %FS ≤± 0.0245 ≤± 0.0184 ≤± 0.0147
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.014 ≤± 0.012 ≤± 0.009
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.0175 ≤± 0.0131 ≤± 0.0105
Zero Balance %FS ≤± 2.0
Safe Overload %FS 120
Ultimate Overload %FS 150
Maximum Deflection mm 3kg: 0.5~0.6 5 – 15kg: 0.6~0.7 20 – 50kg: 0.6~0.8
Eccentric Loading Error %Ld/cm ± 0.002
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 406 ± 6
Output Resistance Ω 350 ± 3
Insulation Resistance (50VDC) MΩ ≥5000
Compensated Temperature °C -10 ~ + 40
Operating Temperature °C -35 ~ + 65
Storage Temperature °C -40 ~ + 70
Load Cell Weight kg ~0.25
Element Material Aluminium
Ingress Protection (acc. to EN 60529) IP65
Recommended Torque on Fixation Bolts Nm < 30kg: 6 >30kg: 10

Wiring

Features:
Cable type: Shielded, 4 conductor cable , conductor AWG 26
Cable diameter: Ø 3.8mm
Cable length: L = 0.40m ± 0.035m, L1 =0.05 ± 0.005m
Cable jacket: PVC
Shield not connected to element

4-Wire Connection Diagram


Excitation (+) Red

Signal (-) White

Excitation (-) Black


Signal (+) Green

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2022.12 L6D Rev12 [email protected]
Page 2/3 www.zemiceurope.com
Type L6D Load Cell

Dimensions in mm

Top View

Note: Screws M6 class 8.8, screw rinsed with oil. Torque as in specifications table.

Front View

Side View Isometric View

* Disclaimer: Newer versions of the L6D may feature a different cable location, positioned halfway the height of the load cell.
This has no effect on the functionality of the load cell, nor on the specifications as described above.

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2022.12 L6D Rev12 [email protected]
Page 3/3 www.zemiceurope.com

You might also like