V6 series V8 series
- V6 series models
The V6 series models are listed below.
Check the following recommended models for replacement according to the current V6 series model.
V612□□□□□ V610□□□□□
None: 100 to 240 VAC None: 100 to 240 VAC
D: 24 VDC D: 24 VDC
None: Analog None: Analog
M: Matrix M: Matrix * There are no matrix switch types to
the V810S.
0: None 0: None
1: Video input 1: Video input
2: RGB input (V610T: analog type only)
1: Standard
2: Card interface 1: Standard
2: Card interface
T: TFT color LCD, SVGA T: TFT color LCD, VGA
C: STN color LCD, SVGA C: STN color LCD, VGA
S: TFT color LCD, SVGA
V609E30M□ V608C10
Standard
None: 100 to 240 VAC
D: 24 VDC
STN color LCD, VGA
Matrix type (touch switches)
2
- Recommended models for replacement of V612 series (1)
V612T/V612C series Recommended models for replacement
MONITOUCH
+0.5 +0.5
313 -0 313 -0
Panel cut-out
dimensions
246
246
(mm)
-0
+0.5
-0
+0.5
Display device TFT color STN color TFT color
D-Sub25pin: RS-232C/422
D-sub 25-pin: RS-232C/422/485 D-sub 9-pin: RS-232C/422/485
Communication I/F
Modular jack 8-pin (2D-Sub15pin: RS-422
ports): RS-232C/485 Modular jack 8-pin (2 ports): RS-232C/485
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 When Hakko Electronics’ optional unit “TC485” is used, use an optional terminal converter “TC-D9”.
*3 When replaced with an analog switch model, two points on the screen cannot be pressed simultaneously. For two-point pressing, use a switch on the screen and a function switch.
*4 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V812SN or V812SMN. Use “CUN-xx” instead.
MONITOUCH
+0.5 +0.5
313 -0 313 -0
Panel cut-out
dimensions
246
246
(mm)
-0
+0.5
-0
+0.5
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 When Hakko Electronics’ optional unit “TC485” is used, use an optional terminal converter “TC-D9”.
*3 When replaced with an analog switch model, two points on the screen cannot be pressed simultaneously. For two-point pressing, use a switch on the screen and a function switch.
*4 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V812SDN or V812SMDN. Use “CUN-xx” instead.
3
V612T/V612C series Recommended models for replacement
MONITOUCH
+0.5 +0.5
313 -0 313 -0
Panel cut-out
dimensions
246
246
(mm)
-0
+0.5
-0
+0.5
Display device TFT color STN color TFT color
MONITOUCH
+0.5 +0.5
313 -0 313 -0
Panel cut-out
dimensions
246
246
(mm)
-0
+0.5
-0
+0.5
4
- Recommended models for replacement of V610 series (1)
V612T/V612C
V610S seriesseries Recommended
Recommendedmodels
models forfor replacement
replacement
MONITOUCH
+0.5 +0.5
289 -0 289 -0
Panel cut-out
216.2
216.2
dimensions
(mm)
-0
+0.5
-0
+0.5
Display device TFT color TFT color
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 When Hakko Electronics’ optional unit “TC485” is used, use an optional terminal converter “TC-D9”.
*3 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V810SN or V810SDN. Use “CUN-xx” instead.
MONITOUCH
+0.5 +0.5
289 -0 289 -0
Panel cut-out
216.2
216.2
dimensions
(mm)
-0
+0.5
-0
+0.5
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 When Hakko Electronics’ optional unit “TC485” is used, use an optional terminal converter “TC-D9”.
*3 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V810iSN or V810iSDN. Use “CUN-xx” instead.
5
V610T/V610C series Recommended models for replacement
V810T/ V810TM/ V810C/ V810CM/
V610Tx0 V610Tx0M V610Cx0 V610Cx0M
V810TN V810TMN V810CN *4 V810CMN *4
MONITOUCH
+0.5 +0.5
289 -0 289 -0
Panel cut-out
216.2
216.2
dimensions
(mm)
-0
+0.5
-0
+0.5
Display device TFT color STN color TFT color
Touch switch Analog Matrix Analog Matrix Analog Matrix Analog Matrix
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 When Hakko Electronic’ optional unit “TC485” is used, use an optional terminal converter “TC-D9”.
*3 When replaced with an analog switch model, two points on the screen cannot be pressed simultaneously. For two-point pressing, use a switch on the screen and a function switch.
*4 When a V6-specific optional FROM cassette “V6EM/4” or SRAM cassette “V6EM/RS” is in use, replace with V810iC/V810iCN or V810iCM/V810iCMN.
*5 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V810TN, V810TMN, V810(i)CN, or V810(i)CMN. Use “CUN-xx” instead.
MONITOUCH
+0.5 +0.5
289 -0 289 -0
Panel cut-out
216.2
216.2
dimensions
(mm)
-0
+0.5
-0
+0.5
Touch switch Analog Matrix Analog Matrix Analog Matrix Analog Matrix
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 When Hakko Electronics’ optional unit “TC485” is used, use an optional terminal converter “TC-D9”.
*3 When replaced with an analog switch model, two points on the screen cannot be pressed simultaneously. For two-point pressing, use a switch on the screen and a function switch.
*4 When a V6-specific optional FROM cassette “V6EM/4” or SRAM cassette “V6EM/RS” is in use, replace with V810iCD/V810iCDN or V810iCMD/V810iCMDN.
*5 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V810TDN, V810TMDN, V810(i)CDN, or V810(i)CMDN. Use “CUN-xx” instead.
6
V610T series Recommended models for replacement
MONITOUCH
+0.5 +0.5
289 -0 289 -0
Panel cut-out
216.2
216.2
dimensions
(mm)
-0
+0.5
-0
+0.5
Display device TFT color TFT color
MONITOUCH
+0.5 +0.5
289 -0 289 -0
Panel cut-out
216.2
216.2
dimensions
(mm)
-0
+0.5
-0
+0.5
7
- Recommended models for replacement of V609E series
V609E series Recommended models for replacement
MONITOUCH
+1 +0.5
277 -0 220.5 -0
Panel cut-out
165.5 -0
dimensions
192
(mm)
+0.5
-0
+1
Use Hakko Electronics’ mounting panel adaptor “PAD-V608-01”.
Resolution 640 400 dots 640 480 dots The resolution of 640 400 is also available.
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 To use a terminal block for connection, use Hakko Electronics’ optional terminal converter “TC-D9”.
*3 Two points on the screen cannot be pressed simultaneously. For two-point pressing, use a switch on the screen and a function switch.
*4 When there is no DC power supply available in the existing system, use Hakko Electronics’ optional unit “V808C-PW”.
V608C10 V808CD/V808CDN *3
MONITOUCH
+0.5 +0.5
-0 -0
220.5 220.5
Panel cut-out
165.5
165.5
dimensions
(mm)
-0
+0.5
-0
+0.5
*1 Use a V8-specific cable as a PLC connection cable. When using the existing cable, use Hakko Electronics’ conversion cable “D9-D25”.
*2 To use a terminal block for connection, use Hakko Electronics’ optional terminal converter “TC-D9”.
*3 When a V6-specific optional FROM cassette “V6EM/4” or SRAM cassette “V6EM/RS” is in use, replace with V808iCD or V808iCDN.
*4 When Hakko Electronics’ communication I/F unit “CU-xx” is currently used, it cannot be attached to V808(i)CDN. Use “CUN-xx” instead.
8
- Recommended models for replacement of V608CH series
V608CH series Recommended models for replacement
MONITOUCH
Communication I/F Terminal block (TB1) Terminal block: RS-232C (TB2) / RS-422/485 (TB3)
MONITOUCH
+0.5 +0.5
174 -0 174 -0
Panel cut-out
dimensions
131
131
(mm)
-0
+0.5
-0
+0.5
9
- Recommended models for replacement of V606i series (2)
V606iC series Recommended models for replacement
MONITOUCH
+0.5 +0.5
-0 -0
174 174
Panel cut-out
dimensions
131
131
(mm)
-0
+0.5
-0
+0.5
Display device STN color STN color
MONITOUCH
+0.5 +0.5
-0 -0
174 174
Panel cut-out
dimensions
131
131
(mm)
-0
+0.5
-0
+0.5
10
- Recommended models for replacement of V606 series (1)
V606C series Recommended models for replacement
MONITOUCH
+0.5 +0.5
174 -0 174 -0
Panel cut-out
dimensions
131
131
(mm)
-0
+0.5
-0
+0.5
Display device STN color STN color
MONITOUCH
+0.5 +0.5
174 -0 174 -0
Panel cut-out
dimensions
131
131
(mm)
-0
+0.5
-0
+0.5
11
- Screen program transfer
- V6 series [Screen configuration software]
V-SFT-5 (Ver. 5)
Windows 98SE / NT4.0 / Me / 2000 /
Modular jack
V-CP (RS-232C)
D-sub XP / XP 64 Edition /
8-pin 9-pin Vista (32bit, 64bit) / 7 (32bit, 64bit) /
8 (32bit, 64bit) / 8.1 (32bit, 64bit) /
10 (32bit, 64bit)
* The indicated recommended model for replacement can be used with minimal restrictions. Please note that other models not described here can also be used; make a selection