Himsen StationaryDG Catalog
Himsen StationaryDG Catalog
Himsen StationaryDG Catalog
Stationary GenSets
Power Range
H17/28 575~960 kW
H21/32 800~1,800 kW
H25/33 1,440~2,700 kW
H25/33V 3,840~6,400 kW
H32/40 2,850~4,275 kW
H32/40V 5,700~9,500 kW
H17/24G 455~880 kW
H35/40G 2,880~4,320 kW
H35/40GV 5,760~9,600 kW
49
Stationary GenSets
50
Stationary GenSets
HYUNDAI-HiMSEN Power Range
51
H17/28
Main Data
Speed 900 rpm 1000 rpm
Frequency 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
5H17/28 575 538 600 561
6H17/28 690 645 720 673
7H17/28 805 757 840 790
8H17/28 920 865 960 902
Based on alternator efficiency of 93.5~94%.
Heat Rate
Load Unit 900 rpm 1000 rpm
kJ/kWhm 8,070
100%
kJ/kWhe 8,631
Based on alternator efficiency 93.5%.
52
H17/28
HYUNDAI-HiMSEN Stationary GenSets
Bore: 170 mm, Stroke: 280 mm
Dimensions
900 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
5 2,791 2,200 4,991 2,314 7.7 13.6
6 3,071 2,200 5,271 2,314 8.5 14.5
7 3,351 2,200 5,551 2,314 9.4 15.6
8 3,631 2,320 5,951 2,314 10.4 16.7
1000 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
5 2,791 2,200 4,991 2,314 7.7 13.6
6 3,071 2,200 5,271 2,314 8.5 14.5
7 3,351 2,200 5,551 2,314 9.4 15.6
8 3,631 2,320 5,951 2,314 10.4 16.7
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
53
H21/32
Main Data
Speed 720 rpm 750 rpm 900 rpm 1000 rpm
Frequency 60 Hz 50 Hz 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW Eng. kW Gen. kW Eng. kW Gen. kW
5H21/32 800 752 800 752 960 910 - -
6H21/32 960 902 960 902 1,200 1,140 1,200 1,140
7H21/32 1,120 1,064 1,120 1,064 1,400 1,330 1,400 1,330
8H21/32 1,280 1,216 1,280 1,216 1,600 1,520 1,600 1,520
9H21/32 1,440 1,368 1,440 1,368 1,800 1,710 1,800 1,710
Based on alternator efficiency of 94~95%.
Heat Rate
Load Unit 720rpm 750 rpm 900rpm 1000 rpm
kJ/kWhm 7,771 7,771 7,814 7,899
100%
kJ/kWhe 8,267 8,267 8,313 8,404
Based on alternator efficiency 94%.
54
H21/32
HYUNDAI-HiMSEN Stationary GenSets
Bore: 210 mm, Stroke: 320 mm
Dimensions
720 / 750 Cyl. Dimension(mm) Dry Mass(ton)
rpm A B 1) C 1) H Engine 2) GenSet 1),3)
5 3,405 1,926 5,331 2,712 14.0 22.4
6 3,781 1,977 5,758 2,712 15.6 23.5
7 4,111 1,977 6,088 2,781 17.1 26.5
8 4,453 2,175 6,628 2,781 18.5 29.1
9 4,783 2,265 7,048 2,911 19.9 31.7
900 / 1000 Cyl. Dimension(mm) Dry Mass(ton)
rpm A B 1) C 1) H Engine 2) GenSet 1),3)
5 3,411 2,097 5,508 2,712 13.4 22.9
6 3,781 1,977 5,758 2,781 15.1 26.1
7 4,235 1,977 6,212 2,781 16.7 28.6
8 4,453 2,175 6,628 2,911 18.4 29.1
9 4,783 2,265 7,048 2,911 19.8 31.7
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
55
H25/33
Main Data
Speed 720 rpm 750 rpm 900 rpm 1000 rpm
Frequency 60 Hz 50 Hz 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW Eng. kW Gen. kW Eng. kW Gen. kW
6H25/33 1,440 1,368 1,500 1,425 1,740 1,653 1,800 1,710
7H25/33 1,680 1,596 1,750 1,663 2,030 1,929 2,100 1,995
8H25/33 1,920 1,824 2,000 1,900 2,320 2,204 2,400 2,280
9H25/33 2,160 2,052 2,250 2,138 2,610 2,480 2,700 2,565
Based on alternator efficiency of 95%.
Heat Rate
Load Unit 720 / 750 rpm 900 / 1000 rpm
kJ/kWhm 7,686 7,729
100%
kJ/kWhe 8,090 8,135
56
H25/33
HYUNDAI-HiMSEN Stationary GenSets
Bore: 250 mm, Stroke: 330 mm
Dimensions
720 / 750 Cyl. Dimension(mm) Dry Mass(ton)
rpm A B 1) C 1) H Engine 2) GenSet 1),3)
6 4,414 2,262 6,676 2,961 20.2 29.8
7 4,794 2,262 7,056 2,961 22.5 33.9
8 5,311 2,262 7,573 3,241 24.1 39.5
9 5,691 2,262 7,953 3,371 26.2 45.0
900 / 1000 Cyl. Dimension(mm) Dry Mass(ton)
rpm A B 1) C 1) H Engine 2) GenSet 1),3)
6 4,414 2,262 6,676 2,961 20.2 29.8
7 4,794 2,262 7,056 3,241 22.5 33.9
8 5,311 2,340 7,651 3,371 24.1 39.5
9 5,691 2,490 8,181 3,371 26.2 45.0
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
57
H25/33V
Main Data
Speed 900 rpm 1000 rpm
Frequency 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
12H25/33V 3,840 3,648 3,840 3,648
14H25/33V 4,480 4,256 4,480 4,256
16H25/33V 5,120 4,864 5,120 4,864
18H25/33V 5,760 5,472 5,760 5,472
20H25/33V 6,400 6,080 6,400 6,080
Based on alternator efficiency of 96%.
Heat Rate
Load Unit 900 rpm 1000 rpm
kJ/kWhm 7,729
100%
kJ/kWhe 8,135
58
H25/33V
HYUNDAI-HiMSEN Stationary GenSets
Bore: 250 mm, Stroke: 330 mm
Dimensions
900 / 1000 Cyl. Dimension(mm) Dry Mass(ton)
rpm A B 1) C 1) H Engine 2) GenSet 1),3)
12 5,524 3,334 8,858 3,750 33.5 58.2
14 5,944 3,504 9,448 3,750 36.5 63.4
16 6,364 3,682 10,046 3,750 39.5 69.6
18 6,784 3,772 10,556 3,750 42.5 77.5
20 7,204 3,727 10,931 3,750 45.5 79.5
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
59
H32/40
Main Data
Speed 720 rpm 750 rpm
Frequency 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
6H32/40 2,850 2,750 2,850 2,750
7H32/40 3,325 3,209 3,325 3,209
8H32/40 3,800 3,667 3,800 3,667
9H32/40 4,275 4,125 4,275 4,125
1) Based on alternator efficiency of 96.5%.
2) In case of diesel oil (Distillate Fuels ISO 8217 DM Grade) operation
continuously, 500 kW/cyl, is available.
Heat Rate
Load Unit 720 rpm 750 rpm
kJ/kWhm 7,600 7,686
100%
kJ/kWhe 7,876 7,965
60
H32/40
HYUNDAI-HiMSEN Stationary GenSets
Bore: 320 mm, Stroke: 400 mm
Dimensions
720 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
6 5,760 3,130 8,890 3,959 33.7 68.6
7 6,112 3,374 9,486 4,130 38.6 77.1
8 6,602 3,594 10,196 4,130 41.5 82.0
9 7,092 4,097 11,189 4,130 44.6 89.1
750 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
6 5,760 3,130 8,890 3,959 33.7 68.6
7 6,112 3,374 9,486 4,130 38.6 77.1
8 6,602 3,594 10,196 4,130 41.5 82.0
9 7,092 4,097 11,189 4,130 44.6 89.1
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
61
H32/40V
Main Data
Speed 720 rpm 750 rpm
Frequency 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
12H32/40V 5,700 5,529 5,700 5,529
14H32/40V 6,650 6,450 6,650 6,450
16H32/40V 7,600 7,372 7,600 7,372
18H32/40V 8,550 8,243 8,550 8,243
20H32/40V 9,500 9,215 9,500 9,215
1) Based on alternator efficiency of 97%.
2) In case of diesel oil (Distillate Fuels ISO 8217 DM Grade) operation
continuously, 500 kW/cyl, is available.
Heat Rate
Load Unit 720 rpm 750 rpm
kJ/kWhm 7,643 7,729
100%
kJ/kWhe 7,880 7,968
62
H32/40V
HYUNDAI-HiMSEN Stationary GenSets
Bore: 320 mm, Stroke: 400 mm
Dimensions
720 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
12 6,624 3,760 10,384 4,723 56.0 108.8
14 7,295 3,860 11,155 4,723 63.3 121.3
16 7,914 3,479 11,393 4,723 69.1 130.9
18 8,585 3,859 12,444 4,794 76.3 141.2
20 9,344 3,659 13,003 4,794 84.0 153.9
750 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
12 6,624 3,760 10,384 4,723 56.0 108.8
14 7,295 3,860 11,155 4,723 63.3 121.3
16 7,914 3,479 11,393 4,723 69.1 130.9
18 8,585 3,859 12,444 4,794 76.3 141.2
20 9,344 3,659 13,003 4,794 84.0 153.9
2254 2650
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
63
H17/24G
Main Data
Speed 1000 rpm 1200 rpm
Frequency 50 Hz 60 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
5H17/24G 455 428 550 517
6H17/24G 546 513 660 620
7H17/24G 637 599 770 724
8H17/24G 728 684 880 827
Based on alternator efficiency of 94%.
Heat Rate
Load Unit 1000 rpm 1200 rpm
kJ/kWhm 8,746
100%
kJ/kWhe 9,305
Fuel gas based on LNG, LCV 49,138 kJ/kg, Methane No. 73.
64
H17/24G
HYUNDAI-HiMSEN Stationary GenSets
Bore: 170 mm, Stroke: 240 mm
Dimensions
Cyl. Dimension(mm) Dry Mass(ton)
1000 rpm
A B 1) C 1) H Engine 2) GenSet 1),3)
5 2,772 2,045 4,817 2,891 6.4 11.6
6 3,052 2,045 5,097 2,891 7.2 13.4
7 3,332 2,045 5,377 2,891 8.0 14.5
8 3,612 2,045 5,657 2,958 8.8 15.6
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
65
H35/40G
Main Data
Speed 720 rpm 750 rpm
Frequency 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
6H35/40G 2,880 2,765 2,880 2,765
7H35/40G 3,360 3,226 3,360 3,226
8H35/40G 3,840 3,686 3,840 3,686
9H35/40G 4,320 4,147 4,320 4,147
Based on alternator efficiency of 96%.
Heat Rate
Load Unit 720 rpm 750 rpm
kJ/kWhm 7,370
100%
kJ/kWhe 7,676
Fuel gas based on LNG, LCV 49,138 kJ/kg, Methane No. 73.
66
H35/40G
HYUNDAI-HiMSEN Stationary GenSets
Bore: 350 mm, Stroke: 400 mm
Dimensions
720 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
6 5,760 3,130 9,900 3,759 33.7 68.6
7 6,112 3,374 10,390 3,882 38.6 77.1
8 6,602 3,594 11,175 4,132 41.5 82.0
9 7,092 4,097 11,765 4,132 44.6 89.1
750 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
6 5,760 3,130 9,900 3,759 33.7 68.6
7 6,112 3,374 10,390 3,882 38.6 77.1
8 6,602 3,594 11,175 4,132 41.5 82.0
9 7,092 4,097 11,765 4,132 44.6 89.1
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
67
H35/40GV
Main Data
Speed 720 rpm 750 rpm
Frequency 60 Hz 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
12H35/40GV 5,760 5,530 5,760 5,530
14H35/40GV 6,720 6,451 6,720 6,451
16H35/40GV 7,680 7,373 7,680 7,373
18H35/40GV 8,640 8,294 8,640 8,294
20H35/40GV 9,600 9,216 9,600 9,216
Based on alternator efficiency of 97%.
Heat Rate
Load Unit 720 rpm 750 rpm
kJ/kWhm 7,370
100%
kJ/kWhe 7,598
Fuel gas based on LNG, LCV 49,138 kJ/kg, Methane No. 73.
68
H35/40GV
HYUNDAI-HiMSEN Stationary GenSets
Bore: 350 mm, Stroke: 400 mm
Dimensions
720 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
12 6,624 3,760 10,384 4,723 56.0 108.8
14 7,295 3,860 11,155 4,723 63.3 121.3
16 7,914 3,479 11,393 4,723 69.1 130.9
18 8,585 3,859 12,444 4,794 76.3 141.2
20 9,344 3,659 13,003 4,794 84.0 153.9
750 rpm Cyl. Dimension(mm) Dry Mass(ton)
A B 1) C 1) H Engine 2) GenSet 1),3)
12 6,624 3,760 10,384 4,723 56.0 108.8
14 7,295 3,860 11,155 4,723 63.3 121.3
16 7,914 3,479 11,393 4,723 69.1 130.9
18 8,585 3,859 12,444 4,794 76.3 141.2
20 9,344 3,659 13,003 4,794 84.0 153.9
2254 2650
Remarks
1) Depending on alternator.
2) Without common base frame.
3) With common base frame & alternator (Maker: HHI-EES).
69
Packaged Power Station (PPS)
REGLA PPS
REGLA 47.6 MW Packaged Power Station in Cuba
(HYUNDAI-HiMSEN 9H21/32 × 28 Sets)
Features Application
- Base load operation - Captive power
- Diesel oil / Heavy fuel oil / - Construction site
Nature gas use - Isolated area
- Compact 40-feet container size - Rental business
- Mobile type (option) - Pumping station
- Environmentally comfortable - Independent power producer
- Low cost of operating and
maintenance
70
Packaged Power Station (PPS)
HYUNDAI-HiMSEN Packaged Power Station
General Specifications
Engine Model 6H17/28 8H17/28 6H21/32 8H21/32 9H21/32
Engine (kW) 690/720 920/960 1,200 1,600 1,800
Generator (kW) 645/673 865/902 1,140 1,520 1,710
Total Weight (ton) 24 30 42 48 50
Dimension (W × H × L) 2.4 m × 3.4 m × 12 m (Container Size)
Cooling Method Radiator / Cooling Tower
Speed 900 rpm / 1,000 rpm
Fuel Diesel oil / Heavy fuel oil
General Specifications
Engine Model 5H17/24G 6H17/24G 7H17/24G 8H17/24G 9H17/24G
Engine (kW) 455/550 546/660 637/770 728/880 819/990
Generator (kW) 428/817 513/620 599/723 684/827 770/930
Total Weight (ton) 22 24 25 26 28
Dimension (W × H × L) 2.4 m × 2.9 m × 12 m (Container Size)
Cooling Method Radiator / Cooling Tower
Speed 1,000 rpm / 1,200 rpm
Fuel Natural Gas
※ The MCR will be based on ISO condition.
3
2
1
4
1 Engine 5 Radiator
2 Generator 6 Exhaust gas silencer
3 Control panel 7 Ventilation air exhaust fan
4 Enclosure
71