S9i Server Manual
S9i Server Manual
S9i Server Manual
-1-
S9i Server Installation Guide
Resale of Bitmain products or services with statements different from or beyond the parameters stated by
Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain
product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any
such statements.
All company and brand products and service names are trademarks or registered trademarks of their respective
holders.
All text and figures included in this publication are the exclusive property of Bitmain, and may not be copied,
reproduced, or used in any way without the express written permission of Bitmain. Information in this
document is subject to change without notice and does not represent a commitment on the part of Bitmain.
Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be
free of errors or omissions. Bitmain reserves the right to make corrections, updates, revisions or changes to
the information in this document.
Bitmain
Tel:+86-400-890-8855
www.bitmain.com
-2-
S9i Server Installation Guide
Table of Contents
1. Overview...................................................................................................................................................... 4
1.1 S9i Server Components.......................................................................................................................5
1.2 Specifications...................................................................................................................................... 6
2. Connecting to the Power Supply................................................................................................................. 7
3. Setting Up the Server................................................................................................................................... 8
4. Configuring the Server............................................................................................................................... 10
5. Monitoring Your Server............................................................................................................................. 11
6. Administering Your Server.........................................................................................................................12
6.1 Checking Your Firmware Version......................................................................................................12
6.2 Upgrading Your System.................................................................................................................... 12
6.3 Modifying Your Password................................................................................................................. 13
6.4 Restoring Initial Settings................................................................................................................... 13
Environmental Requirements........................................................................................................................14
Regulations.....................................................................................................................................................16
-3-
S9i Server Installation Guide
1. Overview
1. Overview
The S9i server is one of the products in Bitmain’s S9 miner series. All S9i servers are tested and configured
prior to shipping to ensure easy set up.
-4-
S9i Server Installation Guide
1. Overview
The S9i server main components and controller front panel are shown in the following figure:
-5-
S9i Server Installation Guide
1. Overview
1.2 Specifications
Hash Rate
S9i-13 TH/s, 13.5 TH/s, 14 TH/s, 14.5 TH/s
Power Consumption
1290 W (13 TH/s)
1310 W (13.5 TH/s)
1320 W (14 TH/s)
1365 W(14.5 TH/s)
Power Efficiency
99 J/TH (13 TH/s)
97 J/TH (13.5 TH/s)
94 J/TH (14 TH/s)
94.14 J/TH (14.5 TH/s)
Rated Voltage
11.60 ~13.00 V
Frequency
Auto-frequency
Network connection mode Ethernet
Operating temperature
0 - 40 °C
Storage temperature -40 - 85°C
Operating humidity
5%RH-95%RH, No condensation
Product weight (without package)
4.2 kg
Product dimensions
350mm(L) x 135mm(W) x 158mm(H)
-6-
S9i Server Installation Guide
● Nine PCI-e connectors for the hash boards. Each hash board has three PCI-e connectors.
● One PCI-e connector located on the controller.
Each hashboard must be powered by the same PSU to prevent possible damage and instability.
1. Connect PSU power cable connectors to each of the nine PCI-e connectors on the top of the S9i server,
ensuring that each hash board is powered by the same PSU.
A. Front fan (intake fans); B. Rear fan (exhaust fans); C. Miner model; D. Serial number (SN) of miner, to review
warranty status; E. Estimated hash rate of miner model; F. Rear fan connector; G. Front fan connector; H. Chain
#8 connector; I. Chain #7 connector; J. Chain #6 connector; K. 6-pin power connector; L. Control board chain
connector; M. 6-pin power connector
2. Connect a PSU power cable connector to the S9i PCI-e connector on the controller.
3. Connect the network cable to the ETH port.
4. To power up your S9i server, connect the PSUs to the power wall outlet.
If you are using more than one PSU,power up the PSU connected to the controller AFTER you have
Powered up the other PSU(s).
-7-
S9i Server Installation Guide
-8-
S9i Server Installation Guide
7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
-9-
S9i Server Installation Guide
1. click General Settings. (Here takes S9i-14T running under the firmware with “Normal” mode as an example)
Option Description
The S9i server can be set up with three mining pools, with decreasing
priority from the first pool (pool 1) to the third pool (pool 3).
The pools with low priority will only be used if all higher priority pools are
offline.
- 10 -
S9i Server Installation Guide
1. Click the status marked below. (Here takes S9i-14T running under the firmware with “Normal” mode as an example)
Temp(PCB) Temperature of each hash board (°C).(Applied only to server with fixed frequency)
● O - indicates OK
● X - indicates error
● - - indicates dead
Note: The S9i server is with automatic frequency. Firmware will stop running when the Temp
(PCB) reaches to 90℃,there will be an error message “Fatal Error: Temperature is too high!”
shown in the bottom of kernel log page.
- 11 -
S9i Server Installation Guide
Make sure that the S9i server remains powered during the upgrade process. If power fails before
the upgrade is completed, you will need to return it to Bitmain for repair.
- 12 -
S9i Server Installation Guide
Resetting your server will reboot it and restore its default settings. The red LED will automatically
flash once every 15 seconds if the reset is operated successfully.
- 13 -
S9i Server Installation Guide
Environmental Requirements
- 14 -
S9i Server Installation Guide
Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of
part per billion.
- 15 -
S9i Server Installation Guide
Regulation:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed
of with your other household waste. Instead, it is your responsibility to dispose of your waste
equipment by handling it over to a designated collection point for the recycling of waste
electrical and electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and ensure that it is
recycled in a manner that protects human health and the environment. For more information
about where you can drop off your waste equipment for recycling, please contact your local city office, your
household waste disposal service or the shop where your purchased the product.
台湾 ROHS:
設備名稱: S9i 服务器
有害物质
外殼 ○ ○ ○ ○ ○ ○
電路板組件 — ○ ○ ○ ○ ○
其他線材 — ○ ○ ○ ○ ○
- 16 -