GSA Report Aparecida Do Taboado

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 10

Preliminary assessment of site solar irradiance

Project Aparecida do Taboado


Geographical coordinates -20.116953°, -51.103367° (-20°07'01", -051°06'12")
Report generated 20 Jul 2023
Generated by Global Solar Atlas
Map link https://globalsolaratlas.info/map?s=-20.116953,-51.103367,10
Project Aparecida do Taboado
Location unnamed road, Aparecida do Taboado, Aparecida do Taboado - MS, Brasil
Geographical coordinates -20.116953°, -51.103367° (-20°07'01", -051°06'12")
Time zone UTC-04, America/Campo_Grande [AMT]
Elevation 391 m
boado - MS, Brasil
Map data

Specific photovoltaic power output PVOUT_specific 1701.5 kWh/kWp


Direct normal irradiation DNI 2007.3 kWh/m²
Global horizontal irradiation GHI 2018.4 kWh/m²
Diffuse horizontal irradiation DIF 687.7 kWh/m²
Global tilted irradiation at optimum angle GTI_opta 2161.3 kWh/m²
Air temperature TEMP 25 °C
Optimum tilt of PV modules OPTA 23 °
Terrain elevation ELE 391 m
Monthly averages

DNI
kWh/m²
Jan 144.9
Feb 149.9
Mar 170.7
Apr 180.1
May 173.4
Jun 174.9
Jul 191
Aug 197.5
Sep 157.3
Oct 151.4
Nov 158.7
Dec 157.9
Yearly 2007.6
Average hourly profiles

Direct normal irradiation [Wh/m²]

Jan Feb Mar Apr May Jun


0-1 0 0 0 0 0 0
1-2 0 0 0 0 0 0
2-3 0 0 0 0 0 0
3-4 0 0 0 0 0 0
4-5 0 0 0 0 0 0
5-6 0 0 0 0 0 0
6-7 109 84 48 18 12 0
7-8 242 275 294 330 295 231
8-9 331 372 420 492 471 478
9 - 10 424 455 515 591 559 579
10 - 11 496 534 582 659 620 650
11 - 12 513 567 597 682 650 684
12 - 13 492 559 581 676 656 693
13 - 14 486 571 579 652 632 675
14 - 15 463 555 545 600 587 635
15 - 16 403 500 497 548 521 582
16 - 17 346 423 431 465 427 464
17 - 18 267 327 332 278 162 161
18 - 19 103 132 85 12 0 0
19 - 20 3 0 0 0 0 0
20 - 21 0 0 0 0 0 0
21 - 22 0 0 0 0 0 0
22 - 23 0 0 0 0 0 0
23 - 24 0 0 0 0 0 0
Sum 4678 5354 5506 6003 5592 5832
Jul Aug Sep Oct Nov Dec
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 8 6
0 13 58 120 193 159
232 305 275 283 342 293
507 513 410 397 437 396
612 615 504 482 511 484
673 680 577 544 557 535
707 721 618 565 554 546
719 737 612 553 542 523
702 718 587 530 532 513
669 671 540 475 498 481
610 603 469 400 426 419
510 500 372 321 355 351
223 284 210 197 264 275
0 11 8 15 71 112
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
6164 6371 5240 4882 5290 5093
Acronyms and glossary

Acronym Full name Unit Type of use


DIF Diffuse horizontal irradiation kWh/m², MJ/m² Average yearly, monthly or
DNI Direct normal irradiation kWh/m², MJ/m² Average yearly, monthly or
ELE Terrain elevation m, ft Elevation of terrain surface
GHI Global horizontal irradiation kWh/m², MJ/m² Average annual, monthly or
GTI Global tilted irradiation kWh/m², MJ/m² Average annual, monthly or
GTI opta Global tilted irradiation at optimum angle kWh/m², MJ/m² Average annual, monthly or
OPTA Optimum tilt of PV modules ° Optimum tilt of fix-mounted
PVOUT_specific Specific photovoltaic power output kWh/kWp Yearly and monthly average
PVOUT_total Total photovoltaic power output kWh, MWh, GWh Yearly and monthly average
TEMP Air temperature °C, °F Average yearly, monthly and
erage yearly, monthly or daily sum of diffuse horizontal irradiation (© 2021 Solargis)
erage yearly, monthly or daily sum of direct normal irradiation (© 2021 Solargis)
evation of terrain surface above/below sea level, processed and integrated from SRTM-3 data and related data products (SRTM
erage annual, monthly or daily sum of global horizontal irradiation (© 2021 Solargis)
erage annual, monthly or daily sum of global tilted irradiation (© 2021 Solargis)
erage annual, monthly or daily sum of global tilted irradiation for PV modules fix-mounted at optimum angle (© 2021 Solargis)
ptimum tilt of fix-mounted PV modules facing towards Equator set for maximizing GTI input (© 2021 Solargis)
arly and monthly average values of photovoltaic electricity (AC) delivered by a PV system and normalized to 1 kWp of installed
arly and monthly average values of photovoltaic electricity (AC) delivered by the total installed capacity of a PV system (© 2021
erage yearly, monthly and daily air temperature at 2 m above ground. Calculated from outputs of ERA5 model (© 2021 ECMW
and related data products (SRTM v4.1 © 2004 - 2021, CGIAR-CSI)

optimum angle (© 2021 Solargis)


© 2021 Solargis)
normalized to 1 kWp of installed capacity (© 2021 Solargis)
d capacity of a PV system (© 2021 Solargis)
ts of ERA5 model (© 2021 ECMWF, post-processed by Solargis)

You might also like