INSTRUMENTATION AND PROCESS REGULATION Test Questions
INSTRUMENTATION AND PROCESS REGULATION Test Questions
11. The diagram below is referred to as …………. (a) self-regulating process (b)
integrating process (c) controller tuning process (d) none of the above
ANSWER: A
12. The volumetric flow rate measurement is achieved by measuring the …………. of a
fluid as it travels through a pipe of known cross-sectional area (a) viscosity (b)
volume (c) velocity (d) mass
ANSWER: C
13. The following are factors affecting flowrate except (a) viscosity (b) density (c)
specific gravity (d) volume
ANSWER: D
14. In the pitot tube, the difference between the differential pressure and static pressure
gives a value for dynamic pressure. TRUE or FALSE
ANSWER: TRUE
15. Variable area flowmeters work with ………. viscous at ………….. velocities (a) low,
high (b) high, low (c) low, low (d) high, high
ANSWER: A
16. Level measurement instrument can be (a) indicator (b) transmitter (c) switch (d) all of
the above
ANSWER: D
17. We have two methods of carrying out level measurement, they are (a) direct and
indirect (b) formal and informal (c) continuous and discontinuous (d) none of the
above
ANSWER: A
18. In displacer level measurement device, as the liquid level ………. in the vessel, the
displacer is buoyed and sheds off its weight. If the liquid level ………….. , the
displacer exerts weight on the torque arm which again creates a motion. (a) increases,
decreases (b) increases, increases (c) decreases, increases (d) decreases, decreases
ANSWER: A
19. In product quality control, the temperature of the steam can be varied by varying the
……… of the gas (a) level (b) flow (c) pressure (d) none of the above
ANSWER: C
20. The bourdon tube works on a simple principle that a bent tube will change its shape
when exposed to variation of ………………. Pressure (a) internal (b) external (c)
internal or external (d) internal and external
ANSWER: D
21. A ………… is use to oppose the applied force and a …………. connects the end of
the bellows to a pointer for indication. (a) bellow, pressure connection (b) bellow,
linkage (c) spring, pressure connection (d) spring, linkage
ANSWER: D
22. In optical pressure sensor, an opaque vane is mounted to the diaphragm and moves in
front of an infrared light beam. As the light is distributed, the received light on the
…………. indicates the position of the diaphragm (a) reference diode (b) measuring
diode (c) reference and measuring diode (d) reference or measuring diode
ANSWER: B
23. In optical pressure sensor, ……………. is used to compensate for the ageing of the
light source (a) opaque vane (b) measuring diode (c) reference diode (d) LED
ANSWER: C
24. ………………… is a collection of Instruments and their application for the purpose
of Observation, Measurement and Control. (a) control (b) calibration (c) instrument
(d) instrumentation
ANSWER: D
25. ………………….. of an instrument refers to the consistency of the result from the
measurement. (a) accuracy (b) precision (c) sensitivity (d) range
ANSWER: B
26. The following are types of temperature instrument except (a) Thermocouples (b)
Thermistors (c) Biometrics (d) polymers
ANSWER: C
27. Resistance Temperature Detector work with the principle that metals resistance
changes as their temperature changes. TRUE OR FALSE ?
ANSWER: FALSE
28. A …………………. is a flowchart that depicts the relationships between major
components in a process. It consist of a series of symbols and notations to illustrate a
process. (a) block flow diagrams (b) process flow diagrams (c) electrical schematics
(d) electrical circuits
ANSWER: B
29. The following should be included in a process flow diagram except (a) critical
equipment and instrumentation (b) flow rate or quantity of a stream (c) operational
data (d) instrumental details
ANSWER: D
30. The figure below is a ………….. diagram (a) process flow (b) piping and
instrumentation (c) isometric flow chart (d) electrical schematics
ANSWER: A