| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2032* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 397.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.2 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.92 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 134.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 9.6 |
| DFF = 0.0 314.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 29.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.8 154.2 12.9 3.9 397.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 208 208 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.876 201 |
| 3.31 T -3.2 397.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2032 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2033* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 364.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.93 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 123.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 2.2 |
| DFF = 0.0 301.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.3 117.7 8.0 2.3 364.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.763 201 |
| 2.11 C -0.7 364.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2033 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2034* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 393.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.4 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.94 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 133.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 4.8 |
| DFF = 0.0 326.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 99.1 126.0 6.3 2.1 393.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 209 206 5 5 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.840 201 |
| 6.97 C 1.6 393.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2034 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2035* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 293.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 6.8 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.70 | L201 FCY = 165.0 |
| CMZ = 0.94 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 99.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 12.1 |
| DFF = 0.0 247.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 108.9 86.2 5.9 4.0 293.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 201 201 201 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.731 201 |
| 108.86 C -4.0 293.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2035 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2036* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 397.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.2 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.92 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 134.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 9.6 |
| DFF = 0.0 314.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 29.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.8 154.2 10.6 3.2 397.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 201 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.876 201 |
| 3.30 T 3.2 397.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2036 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2037* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 364.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.93 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 123.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 2.2 |
| DFF = 0.0 301.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.4 117.7 4.8 1.4 364.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.763 201 |
| 2.11 C 0.7 364.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2037 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2038* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 393.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.4 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.94 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 133.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 4.8 |
| DFF = 0.0 326.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -90.3 124.1 13.1 4.3 393.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.840 201 |
| 6.95 C -1.6 393.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2038 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2039* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 293.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 6.8 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.70 | L201 FCY = 165.0 |
| CMZ = 0.94 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 99.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 12.1 |
| DFF = 0.0 247.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 108.9 86.2 5.9 4.0 293.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 201 201 201 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.731 201 |
| 108.86 C 4.0 293.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2039 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2120* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 144.5( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207 IN NEWT MM|
|--------------- + L207L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 1.9 |
| UNL = 516.7 | L207L207 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.57 | L207 FCY = 165.0 |
| CMZ = 0.85 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 48.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 2.8 |
| DFF = 0.0 86.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 29.7 125.0 4.1 1.2 144.5 |
| LOCATION 0.0 0.5 0.5 0.0 0.5 |
| LOADING 207 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.328 207 |
| 29.68 C -0.9 144.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2120 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2122* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 74.8( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207 IN NEWT MM|
|--------------- + L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + L207 fa = 1.0 |
| UNL = 516.6 | FCZ = 164.9 |
| C = 180.0 + L207 FTZ = 165.0 |
| CMY = 0.43 | L207 FCY = 165.0 |
| CMZ = 0.40 + FTY = 165.0 |
| FYLD = 250.0 |L2 L2 L2 L207 fbz = 13.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.3 |
| DFF = 0.0 30.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 25.4 123.3 1.5 0.3 74.8 |
| LOCATION 0.0 0.5 0.0 0.4 0.5 |
| LOADING 209 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.234 201 |
| 15.49 C -0.1 40.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2122 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2124* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 92.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.8 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.68 | L201L201 FCY = 165.0 |
| CMZ = 0.75 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 12.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 32.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 25.6 111.3 1.2 0.1 92.3 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.212 201 |
| 13.22 C -0.0 -35.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2124 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2126* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 152.4( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.57 | L201L201 FCY = 165.0 |
| CMZ = 0.87 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 51.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 99.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 18.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 27.0 98.3 1.1 0.1 152.4 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.319 201 |
| 11.86 C -0.0 -152.4 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2126 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2128* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 204.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.48 | L201L201 FCY = 165.0 |
| CMZ = 0.92 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 69.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 158.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 15.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 29.5 85.0 1.1 0.1 204.2 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.425 201 |
| 11.05 C -0.0 -204.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2128 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2130* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 247.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.49 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 83.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 209.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 32.3 71.6 1.0 0.1 247.6 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.514 201 |
| 10.61 C -0.0 -247.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2130 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2132* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 282.7( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.51 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 95.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 251.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 10.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 35.0 58.2 1.0 0.1 282.7 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.586 201 |
| 10.40 C -0.0 -282.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2132 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2134* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 309.7( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.53 | L201L201 FCY = 165.0 |
| CMZ = 0.97 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 104.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 286.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 37.5 44.7 1.0 0.1 309.7 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.641 201 |
| 10.30 C -0.0 -309.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2134 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2136* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 328.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.54 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 111.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 312.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 5.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 39.7 31.3 1.0 0.1 328.5 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.680 201 |
| 10.26 C -0.0 -328.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2136 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2138* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 339.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.55 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 114.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 330.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 2.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 41.5 20.2 1.0 0.1 339.1 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 207 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.702 201 |
| 10.24 C -0.0 -339.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2138 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2140* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 341.5( KN-METR) |
|PARAMETER |L20L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | FA = 125.1 |
| KL/R-Z= 57.1 + L201L201 fa = 0.6 |
| UNL = 516.6 | FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.60 | L201 FCY = 165.0 |
| CMZ = 1.00 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 115.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 339.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 0.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 42.9 9.4 1.0 0.1 341.5 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 207 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.707 201 |
| 10.22 C -0.0 -341.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2140 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2142* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 341.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.80 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 115.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 335.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 43.9 11.7 1.0 0.1 341.1 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.706 201 |
| 10.20 C -0.0 -341.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2142 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2144* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 334.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.84 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 113.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 321.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 4.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 44.5 25.1 1.0 0.1 334.2 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.691 201 |
| 10.18 C -0.0 -334.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2144 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2146* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 319.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.71 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 108.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 298.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 44.7 38.4 1.0 0.1 319.0 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.660 201 |
| 10.15 C -0.0 -319.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2146 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2148* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 295.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.65 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 100.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 268.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 9.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 44.5 51.7 1.0 0.1 295.7 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.612 201 |
| 10.14 C -0.0 -295.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2148 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2150* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 264.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.62 | L201L201 FCY = 165.0 |
| CMZ = 0.95 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 89.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 229.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 43.9 64.9 1.0 0.1 264.1 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.548 201 |
| 10.20 C -0.0 -264.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2150 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2152* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 224.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.93 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 76.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 182.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 14.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 43.1 78.0 1.0 0.1 224.4 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.466 201 |
| 10.46 C -0.0 -224.4 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2152 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2154* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 176.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.59 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 59.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 127.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 42.2 90.8 1.1 0.1 176.6 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.369 201 |
| 11.15 C -0.0 -176.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2154 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2156* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 120.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.8 |
| UNL = 516.7 | L207 FCZ = 164.9 |
| C = 180.0 + L207 FTZ = 165.0 |
| CMY = 0.62 | L207 FCY = 165.0 |
| CMZ = 0.83 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 40.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 74.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 41.4 103.1 1.1 0.1 120.7 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.255 201 |
| 12.75 C -0.0 -120.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2156 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2158* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 68.6( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207L207 IN NEWT MM|
|--------------- + L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + L207 fa = 1.0 |
| UNL = 516.6 | L207 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.76 | L207L207 FCY = 165.0 |
| CMZ = 0.59 + L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 0.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 22.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 41.5 114.6 1.1 0.1 68.6 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.218 201 |
| 16.08 C -0.0 1.4 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2158 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2160* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 77.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 1.4 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.68 | FCY = 165.0 |
| CMZ = 0.67 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201L2 L2 fbz = 26.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 19.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 43.3 124.6 1.0 0.1 77.5 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.237 201 |
| 22.56 C -0.1 77.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2160 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2162* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 157.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 2.2 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.42 | L201 FCY = 165.0 |
| CMZ = 0.83 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 53.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.7 |
| DFF = 0.0 86.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 48.4 131.7 1.3 0.2 157.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 209 201 209 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.346 201 |
| 34.69 C -0.2 157.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2162 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2164* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 238.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 3.7 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.89 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 80.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 1.7 |
| DFF = 0.0 168.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 24.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 64.5 129.7 2.2 0.5 238.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 208 201 208 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.530 201 |
| 58.68 C -0.5 238.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2164 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2263* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 144.5( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207 IN NEWT MM|
|--------------- + L207L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 1.9 |
| UNL = 516.7 | L207L207 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.57 | L207 FCY = 165.0 |
| CMZ = 0.85 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 48.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 2.8 |
| DFF = 0.0 86.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 29.7 125.0 2.3 1.1 144.5 |
| LOCATION 0.0 0.5 0.5 0.0 0.5 |
| LOADING 207 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.328 207 |
| 29.69 C 0.9 144.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2263 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2265* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 74.8( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207 IN NEWT MM|
|--------------- + L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + L207 fa = 1.0 |
| UNL = 516.6 | FCZ = 164.9 |
| C = 400.0 + L207 FTZ = 165.0 |
| CMY = 0.43 | L207 FCY = 165.0 |
| CMZ = 0.40 + FTY = 165.0 |
| FYLD = 250.0 |L2 L2 L2 L207 fbz = 13.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.3 |
| DFF = 0.0 30.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 24.6 123.3 1.7 0.3 74.8 |
| LOCATION 0.0 0.5 0.0 0.5 0.5 |
| LOADING 207 201 209 206 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.234 201 |
| 15.49 C 0.1 40.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2265 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2267* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 92.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.8 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.68 | L201L201 FCY = 165.0 |
| CMZ = 0.75 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 12.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 32.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 20.2 111.3 1.2 0.1 92.3 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.212 201 |
| 13.22 C 0.0 -35.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2267 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2269* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 152.4( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.57 | L201L201 FCY = 165.0 |
| CMZ = 0.87 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 51.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 99.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 18.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 17.2 98.3 1.1 0.1 152.4 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.319 201 |
| 11.86 C 0.0 -152.4 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2269 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2271* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 204.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.48 | L201L201 FCY = 165.0 |
| CMZ = 0.92 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 69.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 158.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 15.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 15.1 85.0 1.0 0.1 204.2 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.425 201 |
| 11.05 C 0.0 -204.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2271 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2273* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 247.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.49 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 83.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 209.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -17.8 71.6 1.1 0.1 247.6 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.514 201 |
| 10.61 C 0.0 -247.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2273 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2275* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 282.7( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.51 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 95.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 251.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 10.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -21.1 58.2 1.1 0.1 282.7 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.586 201 |
| 10.40 C 0.0 -282.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2275 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2277* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 309.7( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.53 | L201L201 FCY = 165.0 |
| CMZ = 0.97 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 104.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 286.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -23.8 44.7 1.1 0.1 309.7 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.641 201 |
| 10.30 C 0.0 -309.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2277 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2279* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 328.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.54 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 111.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 312.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 5.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -26.1 31.3 1.0 0.1 328.5 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.680 201 |
| 10.26 C 0.0 -328.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2279 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2281* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 339.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.55 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 114.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 330.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 2.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -28.0 20.2 1.0 0.1 339.1 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 207 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.702 201 |
| 10.24 C 0.0 -339.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2281 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2283* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 341.5( KN-METR) |
|PARAMETER |L20L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | FA = 125.1 |
| KL/R-Z= 57.1 + L201L201 fa = 0.6 |
| UNL = 516.6 | FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.60 | L201 FCY = 165.0 |
| CMZ = 1.00 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 115.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 339.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 0.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -29.5 9.4 1.0 0.1 341.5 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 207 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.707 201 |
| 10.23 C 0.0 -341.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2283 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2285* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 341.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.80 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 115.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 335.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -30.5 11.7 1.0 0.1 341.1 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.706 201 |
| 10.21 C 0.0 -341.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2285 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2287* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 334.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.84 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 113.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 321.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 4.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -31.1 25.1 1.0 0.1 334.2 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.691 201 |
| 10.18 C 0.0 -334.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2287 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2289* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 319.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.71 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 108.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 298.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -31.3 38.4 1.0 0.1 319.0 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.660 201 |
| 10.15 C 0.0 -319.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2289 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2291* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 295.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.65 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 100.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 268.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 9.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -31.1 51.7 1.0 0.1 295.7 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.612 201 |
| 10.14 C 0.0 -295.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2291 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2293* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 264.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.61 | L201L201 FCY = 165.0 |
| CMZ = 0.95 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 89.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 229.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -30.5 64.9 1.0 0.1 264.1 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.548 201 |
| 10.20 C 0.0 -264.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2293 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2295* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 224.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.93 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 76.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 182.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 14.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -29.3 78.0 1.1 0.1 224.4 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.467 201 |
| 10.46 C 0.0 -224.4 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2295 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2297* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 176.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.7 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.59 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 59.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 127.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -27.3 90.8 1.1 0.1 176.6 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.369 201 |
| 11.15 C 0.0 -176.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2297 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2299* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 120.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.8 |
| UNL = 516.7 | L207 FCZ = 164.9 |
| C = 400.0 + L207 FTZ = 165.0 |
| CMY = 0.62 | L207 FCY = 165.0 |
| CMZ = 0.83 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 40.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 74.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -24.4 103.1 1.1 0.1 120.7 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.255 201 |
| 12.75 C 0.0 -120.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2299 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2301* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 68.6( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207L207 IN NEWT MM|
|--------------- + L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + L207 fa = 1.0 |
| UNL = 516.6 | L207 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.76 | L207L207 FCY = 165.0 |
| CMZ = 0.59 + L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 0.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 22.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -20.5 114.6 1.0 0.1 68.6 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 5 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.218 201 |
| 16.08 C 0.0 1.4 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2301 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2303* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 77.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 1.4 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.68 | FCY = 165.0 |
| CMZ = 0.67 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201L2 L2 fbz = 26.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 19.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 22.6 124.6 1.2 0.1 77.5 |
| LOCATION 0.0 0.0 0.5 0.2 0.0 |
| LOADING 201 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.237 201 |
| 22.57 C 0.1 77.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2303 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2305* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 157.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 2.2 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.42 | L201 FCY = 165.0 |
| CMZ = 0.83 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 53.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.7 |
| DFF = 0.0 86.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 34.7 131.7 1.5 0.2 157.9 |
| LOCATION 0.0 0.0 0.5 0.0 0.0 |
| LOADING 201 201 209 206 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.346 201 |
| 34.69 C 0.2 157.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2305 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2307* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 238.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 3.7 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.89 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 80.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 1.7 |
| DFF = 0.0 168.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 24.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 58.7 129.7 2.7 0.5 238.6 |
| LOCATION 0.0 0.0 0.5 0.0 0.0 |
| LOADING 201 201 208 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.530 201 |
| 58.68 C 0.5 238.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2307 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2310* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 249.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 6.5 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.69 | L201 FCY = 165.0 |
| CMZ = 0.95 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 84.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 12.9 |
| DFF = 0.0 217.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 103.9 59.9 6.5 4.3 249.2 |
| LOCATION 0.0 0.5 0.0 0.5 0.5 |
| LOADING 201 201 201 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.642 201 |
| 103.91 C 4.3 249.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2310 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2312* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 209.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 3.4 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.90 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 71.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 1.6 |
| DFF = 0.0 153.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 56.9 105.5 2.3 0.5 209.9 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 208 201 208 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.468 201 |
| 54.67 C -0.5 209.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2312 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2314* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 143.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L207L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 2.0 |
| UNL = 516.7 | L207L207 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.42 | L207 FCY = 165.0 |
| CMZ = 0.85 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 48.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.7 |
| DFF = 0.0 92.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 38.0 108.0 1.3 0.2 143.9 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 208 201 209 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.315 201 |
| 31.37 C -0.2 143.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2314 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2316* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 86.0( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207 IN NEWT MM|
|--------------- + L207L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 1.2 |
| UNL = 516.7 | L207L207 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.67 | L207 FCY = 165.0 |
| CMZ = 0.73 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 26.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 40.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 28.5 101.2 1.0 0.1 86.0 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 209 201 209 208 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.192 201 |
| 19.63 C -0.1 77.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2316 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2318* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 34.5( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | IN NEWT MM|
|--------------- +L201 L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.8 |
| UNL = 516.6 | L207 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.77 | L207 FCY = 165.0 |
| CMZ = 0.40 + L201 FTY = 165.0 |
| FYLD = 250.0 | L2 L2 fbz = 5.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 16.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 17.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 23.1 91.3 1.1 0.1 34.5 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.174 201 |
| 13.38 C -0.0 15.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2318 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2320* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 80.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.63 | L201L201 FCY = 165.0 |
| CMZ = 0.80 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 27.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 37.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 14.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 19.4 79.9 1.1 0.1 80.3 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.171 201 |
| 10.17 C -0.0 -80.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2320 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2322* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 122.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.89 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 41.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 86.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 12.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 16.4 67.7 1.1 0.1 122.3 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.256 201 |
| 8.64 C -0.0 -122.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2322 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2324* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.93 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 52.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 127.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 9.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.6 54.9 1.1 0.1 156.2 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.325 201 |
| 7.97 C -0.0 -156.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2324 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2326* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 182.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.62 | L201L201 FCY = 165.0 |
| CMZ = 0.95 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 61.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 7.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 10.7 41.9 1.1 0.1 182.0 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.378 201 |
| 7.73 C -0.0 -182.0 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2326 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2328* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 199.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.66 | L201L201 FCY = 165.0 |
| CMZ = 0.97 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 67.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 184.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 4.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.0 28.7 1.1 0.1 199.5 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 208 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.414 201 |
| 7.67 C -0.0 -199.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2328 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2330* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 208.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.76 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 70.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 201.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 2.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 7.7 15.4 1.1 0.1 208.9 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 201 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.433 201 |
| 7.68 C -0.0 -208.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2330 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2332* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 210.2( KN-METR) |
|PARAMETER | L201L201L201L201 STRESSES |
|IN NEWT MM |L201 L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 1.00 + FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 71.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 209.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 0.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 7.7 5.0 1.1 0.1 210.2 |
| LOCATION 0.0 0.5 0.0 0.0 0.1 |
| LOADING 201 209 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.436 201 |
| 7.72 C -0.0 -210.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2332 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2334* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 209.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 71.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 202.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 2.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -8.2 14.0 1.1 0.1 209.7 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 1 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.435 201 |
| 7.76 C -0.0 -209.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2334 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2336* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 201.5( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.47 | L201L201 FCY = 165.0 |
| CMZ = 0.97 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 68.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 187.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 4.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -10.7 27.4 1.1 0.1 201.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 1 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.418 201 |
| 7.81 C -0.0 -201.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2336 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2338* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 185.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.41 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 62.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 163.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 7.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -14.0 40.8 1.1 0.1 185.0 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.384 201 |
| 7.89 C -0.0 -185.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2338 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2340* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 160.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.93 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 54.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 131.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 9.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -19.5 54.1 1.0 0.1 160.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.334 201 |
| 8.01 C -0.0 -160.4 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2340 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2342* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.89 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 43.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 91.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 12.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -25.4 67.5 1.0 0.1 127.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.266 201 |
| 8.22 C -0.0 -127.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2342 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2344* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 86.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.81 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 29.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 43.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 14.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -31.5 80.7 1.0 0.1 86.6 |
| LOCATION 0.0 0.0 0.5 0.5 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.182 201 |
| 8.56 C -0.0 -86.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2344 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2346* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 37.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L208 FA = 125.1 |
| KL/R-Z= 57.1 + L208 fa = 0.6 |
| UNL = 516.7 | FCZ = 164.9 |
| C = 400.0 + L209 FTZ = 165.0 |
| CMY = 0.61 | L209 FCY = 165.0 |
| CMZ = 0.49 +L201 L209 FTY = 165.0 |
| FYLD = 250.0 | L201L209 fbz = 3.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 4.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 17.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -37.9 93.8 1.1 0.2 37.4 |
| LOCATION 0.0 0.0 0.5 0.5 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.178 201 |
| 9.09 C 0.0 10.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2346 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2348* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 74.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.6 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.84 | L201 FCY = 165.0 |
| CMZ = 0.71 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 25.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 16.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -44.5 106.6 1.1 0.2 74.3 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.203 201 |
| 9.83 C 0.0 74.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2348 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2350* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 146.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.7 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.96 | L201 FCY = 165.0 |
| CMZ = 0.83 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 49.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 82.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -51.3 119.0 1.1 0.2 146.2 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.306 201 |
| 10.72 C 0.0 146.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2350 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2352* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 225.4( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.7 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.99 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 76.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 155.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 24.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -58.7 130.3 1.2 0.2 225.4 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.470 201 |
| 11.55 C 0.1 225.4 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2352 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2354* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 311.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.7 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.96 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 105.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.4 |
| DFF = 0.0 236.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 26.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -68.9 138.2 1.1 0.1 311.3 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.647 201 |
| 11.39 C 0.1 311.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2354 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2453* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 249.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 6.5 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.69 | L201 FCY = 165.0 |
| CMZ = 0.95 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 84.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 12.9 |
| DFF = 0.0 217.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 103.9 59.9 7.1 4.3 249.2 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 201 201 208 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.642 201 |
| 103.92 C -4.3 249.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2453 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2455* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 209.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 3.4 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.90 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 71.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 1.6 |
| DFF = 0.0 153.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 54.7 105.5 2.5 0.5 209.9 |
| LOCATION 0.0 0.5 0.0 0.5 0.5 |
| LOADING 201 201 208 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.468 201 |
| 54.68 C 0.5 209.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2455 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2457* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 143.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L207L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 2.0 |
| UNL = 516.7 | L207L207 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.42 | L207 FCY = 165.0 |
| CMZ = 0.85 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 48.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.7 |
| DFF = 0.0 92.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 31.4 108.0 1.5 0.2 143.9 |
| LOCATION 0.0 0.5 0.0 0.5 0.5 |
| LOADING 201 201 209 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.315 201 |
| 31.38 C 0.2 143.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2457 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2459* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 86.0( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | L207 IN NEWT MM|
|--------------- + L207L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 1.2 |
| UNL = 516.7 | L207L207 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.67 | L207 FCY = 165.0 |
| CMZ = 0.73 + L207L207 FTY = 165.0 |
| FYLD = 250.0 |L207 fbz = 26.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 40.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 19.6 101.1 1.2 0.1 86.0 |
| LOCATION 0.0 0.5 0.0 0.3 0.5 |
| LOADING 201 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.192 201 |
| 19.64 C 0.1 77.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2459 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2461* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 34.5( KN-METR) |
|PARAMETER | L207STRESSES |
|IN NEWT MM | IN NEWT MM|
|--------------- +L201 L207 -------------|
| KL/R-Y= 9.2 | L207 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.8 |
| UNL = 516.6 | L207 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.77 | L207 FCY = 165.0 |
| CMZ = 0.40 + L206 FTY = 165.0 |
| FYLD = 250.0 | L2 L2 fbz = 5.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 16.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 17.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.6 91.3 1.0 0.1 34.5 |
| LOCATION 0.0 0.5 0.0 0.3 0.5 |
| LOADING 207 201 209 209 207 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.174 201 |
| 13.39 C 0.0 15.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2461 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2463* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 80.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.63 | L201L201 FCY = 165.0 |
| CMZ = 0.80 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 27.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 37.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 14.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 10.4 79.9 1.0 0.1 80.3 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.171 201 |
| 10.18 C 0.0 -80.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2463 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2465* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 122.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.89 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 41.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 86.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 12.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.7 67.7 1.0 0.1 122.3 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.256 201 |
| 8.64 C 0.0 -122.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2465 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2467* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.60 | L201L201 FCY = 165.0 |
| CMZ = 0.93 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 52.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 127.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 9.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.0 54.9 1.0 0.1 156.2 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 201 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.325 201 |
| 7.98 C 0.0 -156.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2467 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2469* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 182.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.62 | L201L201 FCY = 165.0 |
| CMZ = 0.95 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 61.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 7.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 7.7 41.9 1.0 0.1 182.0 |
| LOCATION 0.0 0.5 0.0 0.3 0.0 |
| LOADING 201 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.378 201 |
| 7.73 C 0.0 -182.0 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2469 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2471* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 199.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.66 | L201L201 FCY = 165.0 |
| CMZ = 0.97 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 67.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 184.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 4.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.5 28.7 1.0 0.1 199.5 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 206 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.414 201 |
| 7.68 C 0.0 -199.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2471 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2473* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 208.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.76 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 70.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 201.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 2.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 10.7 15.4 1.1 0.1 208.9 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 206 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.433 201 |
| 7.69 C 0.0 -208.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2473 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2475* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 210.2( KN-METR) |
|PARAMETER | L201L201L201L201 STRESSES |
|IN NEWT MM |L201 L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.91 | L201 FCY = 165.0 |
| CMZ = 1.00 + FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 71.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 209.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 0.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.3 4.7 1.1 0.1 210.2 |
| LOCATION 0.0 0.5 0.0 0.0 0.1 |
| LOADING 206 207 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.436 201 |
| 7.73 C 0.0 -210.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2475 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2477* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 209.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.59 | L201L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 71.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 202.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 2.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 16.1 14.0 1.1 0.1 209.7 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 206 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.435 201 |
| 7.77 C 0.0 -209.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2477 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2479* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 201.5( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.46 | L201L201 FCY = 165.0 |
| CMZ = 0.97 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 68.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 187.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 4.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 19.5 27.4 1.1 0.1 201.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.418 201 |
| 7.82 C 0.0 -201.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2479 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2481* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 185.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 62.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 163.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 7.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 24.7 40.8 1.1 0.1 185.0 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.384 201 |
| 7.90 C 0.0 -185.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2481 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2483* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 160.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.93 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 54.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 131.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 9.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 30.4 54.1 1.1 0.1 160.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.334 201 |
| 8.02 C 0.0 -160.4 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2483 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2485* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.89 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 43.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 91.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 12.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 36.5 67.5 1.1 0.1 127.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.266 201 |
| 8.23 C 0.0 -127.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2485 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2487* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 86.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.5 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.81 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 29.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 43.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 14.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 43.1 80.7 1.0 0.1 86.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.182 201 |
| 8.57 C 0.0 -86.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2487 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2489* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 37.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.6 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L207 FTZ = 165.0 |
| CMY = 0.61 |L208 L207 FCY = 165.0 |
| CMZ = 0.49 + L208L209 FTY = 165.0 |
| FYLD = 250.0 | L207 fbz = 3.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 4.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 17.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 50.3 93.8 1.0 0.2 37.4 |
| LOCATION 0.0 0.0 0.5 0.5 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.178 201 |
| 9.10 C -0.0 10.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2489 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2491* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 74.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.6 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.84 | L201 FCY = 165.0 |
| CMZ = 0.71 + L208L208 FTY = 165.0 |
| FYLD = 250.0 | L208fbz = 25.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 18.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 20.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 58.0 106.6 1.1 0.2 74.3 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.203 201 |
| 9.84 C -0.0 74.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2491 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2493* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 146.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.7 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.96 | L201 FCY = 165.0 |
| CMZ = 0.83 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 49.5 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 82.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 66.0 119.0 1.1 0.2 146.2 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.306 201 |
| 10.73 C -0.0 146.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2493 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2495* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 225.4( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.7 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.99 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 76.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 155.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 24.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 74.6 130.3 1.2 0.2 225.4 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.470 201 |
| 11.57 C -0.1 225.4 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2495 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2497* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 311.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.7 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.96 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 105.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.4 |
| DFF = 0.0 236.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 26.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 84.4 138.2 1.1 0.2 311.3 |
| LOCATION 0.0 0.0 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.647 201 |
| 11.40 C -0.1 311.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2497 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2500* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 364.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.5 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.93 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 123.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 3.8 |
| DFF = 0.0 301.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -42.3 116.9 8.9 2.4 364.0 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.773 201 |
| 8.04 T -1.2 364.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2500 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2502* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 286.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.0 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.98 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 97.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.3 |
| DFF = 0.0 215.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -29.9 131.6 1.2 0.2 286.7 |
| LOCATION 0.0 0.5 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS 7.1.2 BEND C 0.591 201 |
| 0.58 T 0.1 286.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2502 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2504* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 204.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.91 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 69.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 137.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -24.0 124.0 1.1 0.1 204.8 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 5 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.422 201 |
| 1.52 C 0.0 204.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2504 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2506* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 129.3( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.87 | L201 FCY = 165.0 |
| CMZ = 0.82 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 43.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 68.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -19.4 112.9 1.1 0.1 129.3 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.267 201 |
| 1.85 C 0.0 129.3 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2506 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2508* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 61.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.86 | L201 FCY = 165.0 |
| CMZ = 0.66 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 20.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 7.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -14.9 100.6 1.0 0.1 61.2 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.191 201 |
| 1.64 C 0.0 61.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2508 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2510* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 43.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.98 | L201 FCY = 165.0 |
| CMZ = 0.59 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201L206fbz = 0.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 -1.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -10.6 87.8 1.0 0.1 43.9 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.167 201 |
| 1.29 C 0.0 0.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2510 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2512* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 89.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.69 | L201L201 FCY = 165.0 |
| CMZ = 0.83 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 30.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 49.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -6.6 74.8 1.0 0.1 89.5 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.184 201 |
| 0.96 C 0.0 -89.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2512 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2514* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.44 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 43.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 94.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -2.9 61.6 1.0 0.1 127.0 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.261 201 |
| 0.72 C -0.0 -127.0 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2514 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2516* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 52.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 130.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.0 48.2 1.0 0.1 156.3 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.321 201 |
| 0.56 C -0.0 -156.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2516 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2518* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 177.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 60.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 3.4 34.9 1.0 0.1 177.3 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.364 201 |
| 0.46 C -0.0 -177.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2518 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2520* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 190.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 64.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 179.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 6.1 21.5 1.0 0.1 190.2 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.391 201 |
| 0.41 C -0.0 -190.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2520 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2522* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 194.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 66.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 191.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.3 8.1 1.0 0.1 194.9 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.401 201 |
| 0.37 C -0.0 -194.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2522 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2524* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 194.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 66.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 191.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 10.1 8.0 1.0 0.1 194.9 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.401 201 |
| 0.35 C 0.0 -194.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2524 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2526* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 190.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 64.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 179.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 11.6 21.4 1.0 0.1 190.2 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.391 201 |
| 0.33 C 0.0 -190.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2526 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2528* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 177.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 60.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 12.6 34.8 1.0 0.1 177.4 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.365 201 |
| 0.29 C 0.0 -177.4 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2528 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2530* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.3( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 52.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 130.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.2 48.2 1.0 0.1 156.3 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.321 201 |
| 0.22 C 0.0 -156.3 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2530 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2532* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 43.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 94.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.3 61.5 1.0 0.1 127.1 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.261 201 |
| 0.11 C 0.0 -127.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2532 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2534* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 89.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.45 | L201L201 FCY = 165.0 |
| CMZ = 0.83 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 30.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 49.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.1 74.8 1.0 0.1 89.7 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS 7.1.2 BEND C 0.184 201 |
| 0.07 T 0.0 -89.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2534 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2536* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 44.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.0 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.69 | L201 FCY = 165.0 |
| CMZ = 0.59 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 0.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 -1.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 12.3 87.8 1.1 0.1 44.1 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.167 201 |
| 0.34 T -0.0 0.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2536 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2538* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 61.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.0 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 0.66 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 20.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 6.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 11.3 100.7 1.1 0.1 61.0 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.191 201 |
| 0.71 T -0.0 61.0 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2538 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2540* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 129.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.99 | L201 FCY = 165.0 |
| CMZ = 0.82 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 43.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 68.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 10.0 113.0 1.1 0.1 129.2 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.266 201 |
| 1.11 T -0.0 129.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2540 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2542* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 204.7( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 1.00 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 69.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 137.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.9 124.2 1.1 0.1 204.7 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.421 201 |
| 1.39 T -0.0 204.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2542 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2544* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 286.8( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.96 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 97.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 215.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.0 132.0 1.1 0.1 286.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 209 208 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS 7.1.2 BEND C 0.590 201 |
| 0.96 T -0.1 286.8 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2544 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2643* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 364.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.5 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.93 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 123.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 3.8 |
| DFF = 0.0 301.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 30.8 116.8 4.2 1.2 364.0 |
| LOCATION 0.0 0.5 0.0 0.5 0.5 |
| LOADING 209 201 201 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.773 201 |
| 8.04 T 1.2 364.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2643 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2645* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 286.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.0 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.98 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 97.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.3 |
| DFF = 0.0 215.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 29.3 131.6 1.2 0.2 286.7 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS 7.1.2 BEND C 0.591 201 |
| 0.57 T -0.1 286.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2645 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2647* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 204.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.91 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 69.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 137.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 26.4 124.0 1.1 0.2 204.8 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.422 201 |
| 1.53 C -0.0 204.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2647 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2649* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 129.3( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.87 | L201 FCY = 165.0 |
| CMZ = 0.82 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 43.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 68.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 22.1 112.9 1.1 0.1 129.3 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.267 201 |
| 1.85 C -0.0 129.3 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2649 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2651* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 61.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.86 | L201 FCY = 165.0 |
| CMZ = 0.66 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 20.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 7.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 17.3 100.6 1.0 0.1 61.2 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.191 201 |
| 1.65 C -0.0 61.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2651 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2653* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 43.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.98 | L201 FCY = 165.0 |
| CMZ = 0.59 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201L201fbz = 0.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 -1.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 12.5 87.8 1.0 0.1 43.9 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.167 201 |
| 1.29 C -0.0 0.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2653 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2655* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 89.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.69 | L201L201 FCY = 165.0 |
| CMZ = 0.83 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 30.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 49.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.0 74.8 1.1 0.1 89.5 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.184 201 |
| 0.97 C -0.0 -89.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2655 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2657* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.44 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 43.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 94.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 3.9 61.6 1.1 0.1 127.0 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.261 201 |
| 0.72 C 0.0 -127.0 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2657 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2659* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 52.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 130.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.0 48.2 1.1 0.1 156.3 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.321 201 |
| 0.56 C 0.0 -156.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2659 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2661* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 177.3( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 60.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -2.8 34.9 1.0 0.1 177.3 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.364 201 |
| 0.46 C 0.0 -177.3 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2661 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2663* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 190.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 64.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 179.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -5.5 21.5 1.0 0.1 190.2 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.391 201 |
| 0.41 C 0.0 -190.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2663 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2665* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 194.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 66.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 191.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -7.8 8.1 1.0 0.1 194.9 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.401 201 |
| 0.37 C 0.0 -194.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2665 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2667* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 194.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 66.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 191.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.7 8.0 1.0 0.1 194.9 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.401 201 |
| 0.35 C -0.0 -194.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2667 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2669* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 190.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 64.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 179.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -11.2 21.4 1.0 0.1 190.2 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.391 201 |
| 0.33 C -0.0 -190.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2669 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2671* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 177.4( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 60.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -12.2 34.8 1.0 0.1 177.4 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.365 201 |
| 0.29 C -0.0 -177.4 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2671 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2673* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.3( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 52.9 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 130.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -12.9 48.2 1.0 0.1 156.3 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.321 201 |
| 0.22 C -0.0 -156.3 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2673 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2675* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.6 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 43.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 94.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.2 61.5 1.0 0.1 127.1 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.261 201 |
| 0.11 C -0.0 -127.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2675 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2677* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 89.7( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.45 | L201L201 FCY = 165.0 |
| CMZ = 0.83 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 30.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 49.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.2 74.8 1.0 0.1 89.7 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS 7.1.2 BEND C 0.184 201 |
| 0.07 T -0.0 -89.7 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2677 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2679* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 44.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.0 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.69 | L201 FCY = 165.0 |
| CMZ = 0.59 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 0.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 -1.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -12.8 87.8 1.0 0.1 44.1 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.167 201 |
| 0.35 T 0.0 0.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2679 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2681* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 61.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.0 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 0.66 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 20.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 6.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -12.2 100.7 1.1 0.1 61.0 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.191 201 |
| 0.71 T 0.0 61.0 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2681 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2683* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 129.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.99 | L201 FCY = 165.0 |
| CMZ = 0.82 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 43.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 68.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -11.5 113.0 1.1 0.1 129.2 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.266 201 |
| 1.11 T 0.0 129.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2683 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2685* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 204.7( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 1.00 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 69.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 137.7 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -10.7 124.2 1.1 0.1 204.7 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.421 201 |
| 1.40 T 0.0 204.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2685 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2687* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 286.8( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.96 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 97.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 215.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.7 132.0 1.1 0.2 286.8 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS 7.1.2 BEND C 0.590 201 |
| 0.96 T 0.1 286.8 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2687 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2690* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 369.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.4 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.93 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 125.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 2.9 |
| DFF = 0.0 305.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -40.5 118.8 3.1 1.0 369.1 |
| LOCATION 0.0 0.5 0.0 0.5 0.5 |
| LOADING 209 201 201 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.779 201 |
| 6.04 C 1.0 369.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2690 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2692* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 290.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 98.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 218.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -31.3 133.0 1.3 0.2 290.6 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.599 201 |
| 1.85 C -0.1 290.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2692 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2694* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 207.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 70.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 140.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -24.9 125.1 1.2 0.2 207.9 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.428 201 |
| 0.87 C -0.0 207.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2694 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2696* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 131.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.91 | L201 FCY = 165.0 |
| CMZ = 0.82 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 44.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 70.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -19.3 113.9 1.1 0.1 131.8 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.271 201 |
| 0.87 C -0.0 131.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2696 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2698* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 63.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.93 | L201 FCY = 165.0 |
| CMZ = 0.67 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 21.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 8.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -14.1 101.6 1.1 0.1 63.1 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.193 201 |
| 1.12 C -0.0 63.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2698 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2700* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 43.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.86 | L201 FCY = 165.0 |
| CMZ = 0.58 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201L201fbz = 0.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 -0.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.3 88.7 1.1 0.1 43.0 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.169 201 |
| 1.40 C -0.0 2.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2700 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2702* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 89.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.58 | L201L201 FCY = 165.0 |
| CMZ = 0.83 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 30.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 48.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -4.9 75.7 1.0 0.1 89.2 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.184 201 |
| 1.64 C 0.0 -89.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2702 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2704* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 43.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 93.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 3.6 62.4 1.0 0.1 127.1 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.262 201 |
| 1.80 C 0.0 -127.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2704 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2706* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 53.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 130.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 3.2 49.1 1.0 0.1 156.9 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.323 201 |
| 1.91 C 0.0 -156.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2706 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2708* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 178.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.47 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 60.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 5.5 35.7 1.0 0.1 178.5 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.368 201 |
| 1.98 C 0.0 -178.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2708 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2710* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 191.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.76 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 65.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 180.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 8.1 22.3 1.0 0.1 191.9 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.395 201 |
| 2.01 C 0.0 -191.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2710 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2712* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 197.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.71 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 66.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 193.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 10.3 8.9 1.0 0.1 197.2 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.406 201 |
| 2.02 C 0.0 -197.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2712 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2714* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 197.3( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.56 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 66.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 194.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 0.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 12.1 7.3 1.0 0.1 197.3 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.406 201 |
| 2.00 C 0.0 -197.3 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2714 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2716* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 193.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.49 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 65.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 182.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.4 20.7 1.0 0.1 193.2 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.398 201 |
| 1.94 C 0.0 -193.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2716 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2718* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 180.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.44 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 61.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 163.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 14.3 34.2 1.0 0.1 180.9 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.373 201 |
| 1.80 C 0.0 -180.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2718 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2720* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 160.5( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 54.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 135.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 14.7 47.7 1.0 0.1 160.5 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.330 201 |
| 1.53 C 0.0 -160.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2720 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2722* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 131.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.91 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 44.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 99.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 14.5 61.3 1.1 0.1 131.8 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.271 201 |
| 1.04 C 0.0 -131.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2722 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2724* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 95.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.84 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 32.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 54.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 13.6 74.9 1.1 0.1 95.0 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.195 201 |
| 0.19 C 0.0 -95.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2724 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2726* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 49.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.51 | L201L201 FCY = 165.0 |
| CMZ = 0.64 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 1.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 2.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 12.1 88.6 1.1 0.1 49.8 |
| LOCATION 0.0 0.0 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.168 201 |
| 1.17 T -0.0 -4.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2726 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2728* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 56.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.2 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.74 | L201 FCY = 165.0 |
| CMZ = 0.63 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 19.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 0.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 9.7 102.5 1.1 0.1 56.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.195 201 |
| 3.15 T -0.0 56.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2728 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2730* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 125.8( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.4 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.88 | L201 FCY = 165.0 |
| CMZ = 0.81 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 42.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 62.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.8 116.7 1.1 0.1 125.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.262 201 |
| 5.73 T -0.1 125.8 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2730 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2732* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 205.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.5 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.95 | L201 FCY = 165.0 |
| CMZ = 0.87 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 69.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.4 |
| DFF = 0.0 134.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 24.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.6 131.2 1.1 0.2 205.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 209 208 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.427 201 |
| 8.61 T -0.1 205.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2732 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2734* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 295.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.6 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.97 | L201 FCY = 165.0 |
| CMZ = 0.90 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 100.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.9 |
| DFF = 0.0 216.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 27.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -16.7 146.3 1.2 0.3 295.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 207 201 209 201 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.616 201 |
| 10.03 T -0.3 295.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2734 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2833* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 369.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.4 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201 FCY = 165.0 |
| CMZ = 0.93 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 125.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 2.9 |
| DFF = 0.0 305.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 48.6 118.8 5.8 1.6 369.1 |
| LOCATION 0.0 0.5 0.5 0.5 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.779 201 |
| 6.04 C -1.0 369.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2833 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2835* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 290.6( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 0.91 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 98.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 218.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 25.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 33.9 133.0 1.2 0.1 290.6 |
| LOCATION 0.0 0.5 0.0 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.599 201 |
| 1.86 C 0.1 290.6 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2835 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2837* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 207.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.92 | L201 FCY = 165.0 |
| CMZ = 0.88 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 70.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 140.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 23.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 26.2 125.1 1.2 0.1 207.9 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.428 201 |
| 0.88 C 0.0 207.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2837 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2839* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 131.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.91 | L201 FCY = 165.0 |
| CMZ = 0.82 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 44.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 70.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 21.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 20.6 113.9 1.1 0.1 131.8 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.271 201 |
| 0.87 C 0.0 131.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2839 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2841* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 63.1( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.6 | L201L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.93 | L201 FCY = 165.0 |
| CMZ = 0.67 + L201L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 21.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 8.4 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 15.7 101.6 1.1 0.1 63.1 |
| LOCATION 0.0 0.5 0.0 0.0 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.193 201 |
| 1.12 C 0.0 63.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2841 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2843* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 43.0( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + L201 FTZ = 165.0 |
| CMY = 0.86 | L201 FCY = 165.0 |
| CMZ = 0.58 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201L201fbz = 0.7 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 -0.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 11.3 88.7 1.1 0.1 43.0 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.169 201 |
| 1.40 C 0.0 2.1 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2843 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2845* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 89.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.58 | L201L201 FCY = 165.0 |
| CMZ = 0.83 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 30.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 48.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 7.2 75.7 1.0 0.1 89.2 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.184 201 |
| 1.64 C -0.0 -89.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2845 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2847* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 127.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.90 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 43.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 93.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 3.6 62.4 1.0 0.1 127.1 |
| LOCATION 0.0 0.5 0.0 0.0 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.262 201 |
| 1.80 C -0.0 -127.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2847 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2849* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 156.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 180.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 53.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 130.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 3.2 49.1 1.0 0.1 156.9 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.323 201 |
| 1.91 C -0.0 -156.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2849 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2851* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 178.5( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.47 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 60.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 159.8 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.3 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.8 35.7 1.0 0.1 178.5 |
| LOCATION 0.0 0.5 0.5 0.5 0.0 |
| LOADING 207 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.368 201 |
| 1.98 C -0.0 -178.5 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2851 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2853* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 191.9( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.76 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 65.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 180.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -5.4 22.3 1.0 0.1 191.9 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.395 201 |
| 2.01 C -0.0 -191.9 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2853 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2855* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 197.2( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.71 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 66.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 193.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 1.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -7.5 8.9 1.0 0.1 197.2 |
| LOCATION 0.0 0.5 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.406 201 |
| 2.02 C -0.0 -197.2 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2855 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2857* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 197.3( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + L201 FTZ = 165.0 |
| CMY = 0.56 | L201 FCY = 165.0 |
| CMZ = 0.99 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 66.8 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 194.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 0.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -9.3 7.3 1.0 0.1 197.3 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.406 201 |
| 2.00 C -0.0 -197.3 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2857 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2859* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 193.2( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.49 | L201L201 FCY = 165.0 |
| CMZ = 0.98 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 65.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 182.6 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 3.4 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -10.7 20.7 1.0 0.1 193.2 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.398 201 |
| 1.94 C -0.0 -193.2 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2859 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2861* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 180.9( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.44 | L201L201 FCY = 165.0 |
| CMZ = 0.96 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 61.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 163.0 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 6.0 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -11.8 34.2 1.0 0.1 180.9 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.373 201 |
| 1.80 C -0.0 -180.9 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2861 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2863* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 160.5( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.94 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 54.3 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 135.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 8.6 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -12.5 47.7 1.0 0.1 160.5 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.330 201 |
| 1.53 C -0.0 -160.5 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2863 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2865* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 131.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.91 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 44.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 99.1 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 11.1 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.0 61.3 1.0 0.1 131.8 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.271 201 |
| 1.03 C -0.0 -131.8 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2865 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2867* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 95.0( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 125.1 |
| KL/R-Z= 57.1 + L201 fa = 0.0 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.40 | L201L201 FCY = 165.0 |
| CMZ = 0.84 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 32.2 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 |
| DFF = 0.0 54.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 13.7 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.4 74.9 1.0 0.1 95.0 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.1(A) 0.195 201 |
| 0.19 C -0.0 -95.0 0.52 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2867 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2869* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 49.8( KN-METR) |
|PARAMETER | L201STRESSES |
|IN NEWT MM | L201L201 IN NEWT MM|
|--------------- + L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + L201 fa = 0.1 |
| UNL = 516.7 | L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.51 | L201L201 FCY = 165.0 |
| CMZ = 0.64 + L201 FTY = 165.0 |
| FYLD = 250.0 |L201 fbz = 1.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 2.2 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 16.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -13.7 88.6 1.0 0.1 49.8 |
| LOCATION 0.0 0.0 0.5 0.3 0.5 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.168 201 |
| 1.17 T 0.0 -4.7 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2869 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2871* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 56.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.2 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.74 | L201 FCY = 165.0 |
| CMZ = 0.63 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 19.0 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.1 |
| DFF = 0.0 0.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 19.5 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -14.1 102.5 1.0 0.1 56.1 |
| LOCATION 0.0 0.0 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS SHEAR-Y 0.195 201 |
| 3.15 T 0.0 56.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2871 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2873* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 125.8( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.4 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.88 | L201 FCY = 165.0 |
| CMZ = 0.81 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 42.6 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.2 |
| DFF = 0.0 62.9 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 22.2 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -14.7 116.7 1.0 0.1 125.8 |
| LOCATION 0.0 0.0 0.5 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.262 201 |
| 5.74 T 0.1 125.8 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2873 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2875* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 205.1( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.5 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.95 | L201 FCY = 165.0 |
| CMZ = 0.87 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 69.4 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.4 |
| DFF = 0.0 134.3 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 24.9 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -15.5 131.2 1.0 0.2 205.1 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 209 201 209 209 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.427 201 |
| 8.62 T 0.1 205.1 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2875 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CM UNIT |
| * |=============================| ===|=== ------------ |
|MEMBER 2877* | INDIAN SECTIONS | | AX = 159.0 |
| * | TB ISMB500 | | --Z AY = 52.6 |
|DESIGN CODE * | | | AZ = 73.3 |
| IS-800 * =============================== ===|=== SY = 331.3 |
| * SZ = 2953.1 |
| * |<---LENGTH (ME= 0.52 --->| RY = 5.6 |
|************* RZ = 21.9 |
| |
| 295.6( KN-METR) |
|PARAMETER |L201 STRESSES |
|IN NEWT MM | L201 IN NEWT MM|
|--------------- + L201L201 -------------|
| KL/R-Y= 9.2 | L201 FA = 150.0 |
| KL/R-Z= 57.1 + fa = 0.6 |
| UNL = 516.7 | L201L201 FCZ = 164.9 |
| C = 400.0 + FTZ = 165.0 |
| CMY = 0.97 | L201 FCY = 165.0 |
| CMZ = 0.90 + L201L201 FTY = 165.0 |
| FYLD = 250.0 | L201fbz = 100.1 |
| NSF = 1.0 +---+---+---+---+---+---+---+---+---+---| fby = 0.9 |
| DFF = 0.0 216.5 FV = 100.0 |
| dff = 0.0 ABSOLUTE MZ ENVELOPE fv = 27.8 |
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY ( KN-METR) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE -16.7 146.3 1.1 0.3 295.6 |
| LOCATION 0.0 0.0 0.0 0.3 0.0 |
| LOADING 207 201 209 208 201 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY ( KN-METR) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS IS-7.1.2 0.616 201 |
| 10.03 T 0.3 295.6 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------|
WARNING: THE SECTION OF MEMBER NO 2877 IS SLENDER ACCORDING TO CLAUSE 3.5.2.1
OF IS:800-1984 AS B/T RATIO OF COMPRESSION FLANGE EXCEEDS 20.00
2148. STEEL TAKE OFF LIST 2032 TO 2039 2120 2122 2124 2126 2128 2130 2132 2134 2136 -
STEEL TAKE-OFF
--------------
2149. 2138 2140 2142 2144 2146 2148 2150 2152 2154 2156 2158 2160 2162 2164 2263 -
2150. 2265 2267 2269 2271 2273 2275 2277 2279 2281 2283 2285 2287 2289 2291 2293 -
2151. 2295 2297 2299 2301 2303 2305 2307 2310 2312 2314 2316 2318 2320 2322 2324 -
2152. 2326 2328 2330 2332 2334 2336 2338 2340 2342 2344 2346 2348 2350 2352 2354 -
2153. 2453 2455 2457 2459 2461 2463 2465 2467 2469 2471 2473 2475 2477 2479 2481 -
2154. 2483 2485 2487 2489 2491 2493 2495 2497 2500 2502 2504 2506 2508 2510 2512 -
2155. 2514 2516 2518 2520 2522 2524 2526 2528 2530 2532 2534 2536 2538 2540 2542 -
2156. 2544 2643 2645 2647 2649 2651 2653 2655 2657 2659 2661 2663 2665 2667 2669 -
2157. 2671 2673 2675 2677 2679 2681 2683 2685 2687 2690 2692 2694 2696 2698 2700 -
2158. 2702 2704 2706 2708 2710 2712 2714 2716 2718 2720 2722 2724 2726 2728 2730 -
2159. 2732 2734 2833 2835 2837 2839 2841 2843 2845 2847 2849 2851 2853 2855 2857 -
2160. 2859 2861 2863 2865 2867 2869 2871 2873 2875 2877
TB ISMB500 99.20 121.166
----------------
TOTAL = 121.166
2161. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2016 Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************